48V Power Queen LiFePO4 Balancing with Victron MPPT150/35 A Weeks Worth of Data to Digest
Join this channel to get access to perks:
ua-cam.com/channels/ee2gYB7-CZNWJwVgexI3xw.htmljoin
Solar stuff:
Blue Sea 100amp breaker:amzn.to/4eOV4bK
Blue Sea 50 amp breaker:amzn.to/3VQuMNE
Renogy 60 amp fuse:amzn.to/3xEuOAk
WindyNation 60 amp fuse:amzn.to/4cLn7XO
Spartan Power 80 amp fuse:amzn.to/4eFE73L
Resistor:amzn.to/3xr2PnI
Victron MPPT 100/30:amzn.to/3RDPM9c
Victron MPPT 75/15:amzn.to/4cx3faV
Watt Meter:amzn.to/4egVSpE
Induction cooktop:amzn.to/3z7KyMD
Air Fryer:amzn.to/3VKb7QF
Blue wall:
IP22 blue smart charger 12/30:amzn.to/3Vu8XoN
MPPT 100/30 Charge controller:amzn.to/4cmIVtB
phoenix 12/800 Inverter:amzn.to/3vrUa36
Smart Shunt:amzn.to/3x4tplR
Smart Dongle:amzn.to/4aholcN
www.litime.com/products/litime-12v-100ah-tm-deep-cycle-lifepo4-battery-for-trolling-motors
LiTime 12v 100Ah LiFePO4 battery:Ampere Time is rebranding to LiTime. All former Ampere Time warranties will be covered through LiTime .
Discount code: Aloha (6%)
Official website: bit.ly/3YfF7mV
Solar panel cables 10awg 30ft:amzn.to/3PGtZgm
Solar panel cables 8awg 30ft:amzn.to/44Xio14
Chins 12V 100Ah smart LiFePO4:amzn.to/48akxcC
Chins 12.8v 300ah LiFePO4 battery:amzn.to/3M22V7g
Victron 100/50 MPPT smart solar charge controller:amzn.to/3GRcypg
Victron 12v 30amp smart charger:amzn.to/37u3BDd
Reliable 12v3000watt pure sine wave inverter:amzn.to/3wdgGta
Epever 40amp charge controller:amzn.to/38hDgsv
Newpowa 12v 100watt monocrystalline solar panels:amzn.to/3yqM2z5
Aili battery monitor:amzn.to/3sqwqYF
50 amp breakers:amzn.to/3kTCiFt
Bus bars:amzn.to/3ynZPXd
Solar panel isolator switch:amzn.to/3QoZN8i
Solar panel isolator switch breaker box:amzn.to/3ZkdTMn
Victron energy Phoenix 12/375 pure sine wave inverter:a.co/d/fhLT5fb
Victron energy smart solar charge controller MPPT 75/15:a.co/d/2ub3biw
Victron energy smart dongle:a.co/d/43R2coZ
Solar isolator switch:a.co/d/iftd9YU
50 amp breaker:a.co/d/cyoBzIZ
Bougue RV solar panels:a.co/d/3IA9qk1
Bougue RV solar panel cables:a.co/d/7R9YhQi
10 ga. wire:a.co/d/4kVdnVn
Crimps and heat shrink:a.co/d/awkehsW
double cable pass through wall gland:a.co/d/5T7o6Av
48V system:
Power Queen 51.2V LiFePO4 battery:ipowerqueen.com/?ref=pBJrCO3s
Discount code for Power Queen batteries:Bob3
Victron energy smart solar charge controller MPPT 150/35:amzn.to/3TDwxeD
Reliable 48V 3000watt pure sine wave inverter:amzn.to/3yUr7Ul
Newpowa 12v 100watt monocrystalline 9bb panels:amzn.to/3D8yWIK
Bus bars:amzn.to/3DcpYu8r
MRBF Terminal Fuse block:amzn.to/3DzcMjd
REDODO system:
REDODO 12v 200ah LiFePO4 battery:www.redodopower.com/?ref=P6pilyog
Site wide 5% discount code: Aloha5
Reliable 12v 2000watt pure sine wave inverter:amzn.to/3RTQCfS
Victron energy smart MPPT solar charge controller:amzn.to/3xdp8cX
Bus bars:amzn.to/3BvYTAY
Solar panels:amzn.to/3UqajNb
Solar panels:amzn.to/3Fogyga
Solar panel extension cables:amzn.to/3RQzY0C
Solar panel isolator switch:amzn.to/3eEOpGI
Battery cables one foot :amzn.to/3DehnHK
Battery cables two feet:amzn.to/3TTxeBv
Battery monitor:amzn.to/3L13Fd0
Breakers:amzn.to/3Bs4V5S
Fuse:amzn.to/3qpNZXi
Wall pass through for solar cables:amzn.to/3RyNE0t
Solar panels:amzn.to/3EO3IGu
Timeusb system:Victron energy 24/375 phoenix pure sine wave inverter: amzn.to/3ri6wbM
V.E. bluetooth smart dongle: amzn.to/3PU2jW9
Official website link:www.timeusbpower.com/?ref=MmqcZfny
Discount code for Timeusb 25.6V 100ah LiFePO4 battery: 808
Amazon link:amzn.to/3LrBCnn
Reliable 24V 800watt pure sine wave inverter:amzn.to/3UU2yzq
Victron energy smart MPPT 75/15 solar charge controller:amzn.to/3xdp8cX
Bus bars:amzn.to/3BvYTAY
Solar panel extension cables:amzn.to/3RQzY0C
Solar panel isolator switch:amzn.to/3eEOpGI
Solar panels:amzn.to/3fius8S
Battery cables one foot :amzn.to/3DehnHK
Battery cables two feet:amzn.to/3TTxeBv
Battery monitor:amzn.to/3L13Fd0
Breakers:amzn.to/3Bs4V5S
Fuse:amzn.to/3qpNZXi
Small inline fuse:amzn.to/3B3mWWE
Wall pass through for solar cables:amzn.to/3RyNE0t
As an affiliate of REDODO Power I earn from qualifying purchase
As a Timeusb affiliate I earn from qualifying purchases
As an Amazon Associate I earn from qualifying purchases
As a Power Queen affiliate I earn from qualifying purchases
As an affiliate of LiTime batteries I earn from qualifying purchases
Переглядів: 887

Відео

48V LiFePO4 Battery Balancing Issue? Let's Find out!
Переглядів 1,3 тис.9 годин тому
Join this channel to get access to perks: ua-cam.com/channels/ee2gYB7-CZNWJwVgexI3xw.htmljoin Solar stuff: Blue Sea 100amp breaker:amzn.to/4eOV4bK Blue Sea 50 amp breaker:amzn.to/3VQuMNE Renogy 60 amp fuse:amzn.to/3xEuOAk WindyNation 60 amp fuse:amzn.to/4cLn7XO Spartan Power 80 amp fuse:amzn.to/4eFE73L Resistor:amzn.to/3xr2PnI Victron MPPT 100/30:amzn.to/3RDPM9c Victron MPPT 75/15:amzn.to/4cx3f...
Reliable Electric 48V 3000W PSW Inverter Acting Unreliable: Rated DC Input 40V-60V OVD @ 55V
Переглядів 2,1 тис.12 годин тому
Join this channel to get access to perks: ua-cam.com/channels/ee2gYB7-CZNWJwVgexI3xw.htmljoin Solar stuff: Blue Sea 100amp breaker:amzn.to/4eOV4bK Blue Sea 50 amp breaker:amzn.to/3VQuMNE Renogy 60 amp fuse:amzn.to/3xEuOAk WindyNation 60 amp fuse:amzn.to/4cLn7XO Spartan Power 80 amp fuse:amzn.to/4eFE73L Resistor:amzn.to/3xr2PnI Victron MPPT 100/30:amzn.to/3RDPM9c Victron MPPT 75/15:amzn.to/4cx3f...
Small Solar System Saves the Day: Home Business Keeps Running During a Grid Outage
Переглядів 2,2 тис.День тому
Join this channel to get access to perks: ua-cam.com/channels/ee2gYB7-CZNWJwVgexI3xw.htmljoin OutBack Flexmax 80:amzn.to/3LaqWtR Renogy 2000W PSW Inverter:amzn.to/3xOe3Tl Solar stuff: Blue Sea 100amp breaker:amzn.to/4eOV4bK Blue Sea 50 amp breaker:amzn.to/3VQuMNE Renogy 60 amp fuse:amzn.to/3xEuOAk WindyNation 60 amp fuse:amzn.to/4cLn7XO Spartan Power 80 amp fuse:amzn.to/4eFE73L Resistor:amzn.to...
Crucial Backup System Deployed : Battling Melanoma with Resilience and Technology?
Переглядів 1,6 тис.День тому
Join this channel to get access to perks: ua-cam.com/channels/ee2gYB7-CZNWJwVgexI3xw.htmljoin Solar Shower Bag:amzn.to/3VOWTNs Blue Sea 100amp breaker:amzn.to/4eOV4bK Blue Sea 50 amp breaker:amzn.to/3VQuMNE Renogy 60 amp fuse:amzn.to/3xEuOAk WindyNation 60 amp fuse:amzn.to/4cLn7XO Spartan Power 80 amp fuse:amzn.to/4eFE73L Resistor:amzn.to/3xr2PnI Victron MPPT 100/30:amzn.to/3RDPM9c Victron MPPT...
Melting Fuses and Breaking Breakers
Переглядів 1,9 тис.14 днів тому
Join this channel to get access to perks: ua-cam.com/channels/ee2gYB7-CZNWJwVgexI3xw.htmljoin Today's stuff: Blue Sea 100amp breaker:amzn.to/4eOV4bK Blue Sea 50 amp breaker:amzn.to/3VQuMNE Renogy 60 amp fuse:amzn.to/3xEuOAk WindyNation 60 amp fuse:amzn.to/4cLn7XO Spartan Power 80 amp fuse:amzn.to/4eFE73L Resistor:amzn.to/3xr2PnI Victron MPPT 100/30:amzn.to/3RDPM9c Victron MPPT 75/15:amzn.to/4cx...
Living on Solar Made Easy: Beginner Series Pt.4 Your 1st Build A.k.a. Independence Day!
Переглядів 2,3 тис.14 днів тому
Join this channel to get access to perks: ua-cam.com/channels/ee2gYB7-CZNWJwVgexI3xw.htmljoin Resistor:amzn.to/3xr2PnI Victron MPPT 100/30:amzn.to/3RDPM9c Victron MPPT 75/15:amzn.to/4cx3faV Watt Meter:amzn.to/4egVSpE Induction cooktop:amzn.to/3z7KyMD Air Fryer:amzn.to/3VKb7QF stuff I use everyday: Blue wall: IP22 blue smart charger 12/30:amzn.to/3Vu8XoN MPPT 100/30 Charge controller:amzn.to/4cm...
Living on Solar Made Easy: Beginner Series Pt.3 The Heart and Brains of Your System
Переглядів 2,4 тис.21 день тому
Join this channel to get access to perks: ua-cam.com/channels/ee2gYB7-CZNWJwVgexI3xw.htmljoin Victron MPPT 100/30:amzn.to/3RDPM9c Victron MPPT 75/15:amzn.to/4cx3faV Watt Meter:amzn.to/4egVSpE Induction cooktop:amzn.to/3z7KyMD Air Fryer:amzn.to/3VKb7QF stuff I use everyday: Blue wall: IP22 blue smart charger 12/30:amzn.to/3Vu8XoN MPPT 100/30 Charge controller:amzn.to/4cmIVtB phoenix 12/800 Inver...
Earliest Summer Solstice in Over 200 Years is Today: Take Stock on Your Solar System Now
Переглядів 1,2 тис.21 день тому
Join this channel to get access to perks: ua-cam.com/channels/ee2gYB7-CZNWJwVgexI3xw.htmljoin Watt Meter:amzn.to/4egVSpE Induction cooktop:amzn.to/3z7KyMD Air Fryer:amzn.to/3VKb7QF stuff I use everyday: Blue wall: IP22 blue smart charger 12/30:amzn.to/3Vu8XoN MPPT 100/30 Charge controller:amzn.to/4cmIVtB phoenix 12/800 Inverter:amzn.to/3vrUa36 Smart Shunt:amzn.to/3x4tplR Smart Dongle:amzn.to/4a...
Living on Solar Made Easy: Beginner Series Pt.2 Appliance Values Added? Get Ready For Components!
Переглядів 2,1 тис.28 днів тому
Join this channel to get access to perks: ua-cam.com/channels/ee2gYB7-CZNWJwVgexI3xw.htmljoin Watt Meter:amzn.to/4egVSpE Induction cooktop:amzn.to/3z7KyMD Air Fryer:amzn.to/3VKb7QF stuff I use everyday: Blue wall: IP22 blue smart charger 12/30:amzn.to/3Vu8XoN MPPT 100/30 Charge controller:amzn.to/4cmIVtB phoenix 12/800 Inverter:amzn.to/3vrUa36 Smart Shunt:amzn.to/3x4tplR Smart Dongle:amzn.to/4a...
Living on Solar Made Easy: Beginner Series Pt.1 Considerations for Sizing Your First system
Переглядів 1,5 тис.Місяць тому
Join this channel to get access to perks: ua-cam.com/channels/ee2gYB7-CZNWJwVgexI3xw.htmljoin Watt Meter:amzn.to/4egVSpE stuff I use everyday: Blue wall: IP22 blue smart charger 12/30:amzn.to/3Vu8XoN MPPT 100/30 Charge controller:amzn.to/4cmIVtB phoenix 12/800 Inverter:amzn.to/3vrUa36 Smart Shunt:amzn.to/3x4tplR Smart Dongle:amzn.to/4aholcN Other solar stuff I use everyday: www.litime.com/produ...
Living on Solar Made Easy: Beginning Concepts
Переглядів 3,1 тис.Місяць тому
Join this channel to get access to perks: ua-cam.com/channels/ee2gYB7-CZNWJwVgexI3xw.htmljoin stuff I use everyday: Blue wall: IP22 blue smart charger 12/30:amzn.to/3Vu8XoN MPPT 100/30 Charge controller:amzn.to/4cmIVtB phoenix 12/800 Inverter:amzn.to/3vrUa36 Smart Shunt:amzn.to/3x4tplR Smart Dongle:amzn.to/4aholcN Other solar stuff I use everyday: www.litime.com/products/litime-12v-100ah-tm-dee...
Spring Cleaning Giveaway results!
Переглядів 381Місяць тому
Join this channel to get access to perks: ua-cam.com/channels/ee2gYB7-CZNWJwVgexI3xw.htmljoin stuff I use everyday: Blue wall: IP22 blue smart charger 12/30:amzn.to/3Vu8XoN MPPT 100/30 Charge controller:amzn.to/4cmIVtB phoenix 12/800 Inverter:amzn.to/3vrUa36 Smart Shunt:amzn.to/3x4tplR Smart Dongle:amzn.to/4aholcN Other solar stuff I use everyday: www.litime.com/products/litime-12v-100ah-tm-dee...
Summer Solstice Only Days Away! Spring Cleaning Giveaway! Solar Life in the 808 All Day, Everyday🤙
Переглядів 2,5 тис.Місяць тому
Join this channel to get access to perks: ua-cam.com/channels/ee2gYB7-CZNWJwVgexI3xw.htmljoin stuff I use everyday: Blue wall: IP22 blue smart charger 12/30:amzn.to/3Vu8XoN MPPT 100/30 Charge controller:amzn.to/4cmIVtB phoenix 12/800 Inverter:amzn.to/3vrUa36 Smart Shunt:amzn.to/3x4tplR Smart Dongle:amzn.to/4aholcN Other solar stuff I use everyday: www.litime.com/products/litime-12v-100ah-tm-dee...
Solar Resilience: Powering Your Home Even Without Direct Sunlight?
Переглядів 1,8 тис.Місяць тому
Solar Resilience: Powering Your Home Even Without Direct Sunlight?
Taming the Jungle: Conquer Your Yard with 6Ah's of Lithium and Sunshine Power!
Переглядів 1,5 тис.Місяць тому
Taming the Jungle: Conquer Your Yard with 6Ah's of Lithium and Sunshine Power!
Solar Powered Dreams: Top Two Must Know Tips for Buying Raw Land Off Grid
Переглядів 1,6 тис.Місяць тому
Solar Powered Dreams: Top Two Must Know Tips for Buying Raw Land Off Grid
Air Frying on Solar: Weaning off the LP
Переглядів 1,9 тис.Місяць тому
Air Frying on Solar: Weaning off the LP
The Bull & The Puma vs. The Dinosaur: Living on Solar in the middle of Nowhere! R.I.P. Grey boy!
Переглядів 1,3 тис.Місяць тому
The Bull & The Puma vs. The Dinosaur: Living on Solar in the middle of Nowhere! R.I.P. Grey boy!
Solarage X 12.8V 100Ah Mini LiFePO4...How Low Will the $ continue to Drop!?
Переглядів 2,5 тис.2 місяці тому
Solarage X 12.8V 100Ah Mini LiFePO4...How Low Will the $ continue to Drop!?
Blazing Welds : Dual Calpha 3500W 48V Solar Charger Inverters Split Phase @240V Get Your Hood On!
Переглядів 1,3 тис.2 місяці тому
Blazing Welds : Dual Calpha 3500W 48V Solar Charger Inverters Split Phase @240V Get Your Hood On!
Steadfast Power: Unwavering Performance of Pure Sine Wave Inverters Through Time
Переглядів 2,1 тис.2 місяці тому
Steadfast Power: Unwavering Performance of Pure Sine Wave Inverters Through Time
Calpha 48V 3500W All in one Solar Charger Inverter : Learning curve on programming, but works great!
Переглядів 1,7 тис.2 місяці тому
Calpha 48V 3500W All in one Solar Charger Inverter : Learning curve on programming, but works great!
should be doing...or not
Переглядів 8342 місяці тому
should be doing...or not
Update on the TOPBULL 3000W PSW Inverter! Reporting Live results for You! Jeez that was quick!
Переглядів 1,6 тис.2 місяці тому
Update on the TOPBULL 3000W PSW Inverter! Reporting Live results for You! Jeez that was quick!
TOPBULL 3000W PSW Inverter ~ Portable Power Effortlessly hooked up ~ Get Ready for the Storm
Переглядів 1,2 тис.2 місяці тому
TOPBULL 3000W PSW Inverter ~ Portable Power Effortlessly hooked up ~ Get Ready for the Storm
Insurance for your LiFePO4 batteries
Переглядів 2,7 тис.2 місяці тому
Insurance for your LiFePO4 batteries
Lazy Daze in the jungle
Переглядів 8582 місяці тому
Lazy Daze in the jungle
balancing to perfection, or pretty darn close ~ DIY mixed bag LiFePO4's
Переглядів 2,9 тис.2 місяці тому
balancing to perfection, or pretty darn close ~ DIY mixed bag LiFePO4's
Notes on 1st 48V LiFePO battery from the Bungaloha : I'm Listening, keep it coming my friends! 🤙
Переглядів 8412 місяці тому
Notes on 1st 48V LiFePO battery from the Bungaloha : I'm Listening, keep it coming my friends! 🤙

КОМЕНТАРІ

  • @matthewwakeham2206
    @matthewwakeham2206 Годину тому

    If the inverter has been gradually degrading then that would indicate it does have an issue. I was going to suggest switching off the solar charge controller when the battery is at full charge and then switching on the inverter and see if the problem occurs. I would suggest that if the inverter has been seeing voltage spikes and bms disconnects since it was installed then that could have damaged it. Even if you replace the inverter you would still need to ensure the bms disconnects do not continue which probably means setting the absorption voltage a bit lower say 56 volts or even down to 55.6.

  • @jimbor2279
    @jimbor2279 Годину тому

    Bob, my initial thought a few days ago was that the battery itself was probably not the problem. Usually it would be the inverter. Anyway, with my limited knowledge, I think your thought pattern about replacing the inverter with the all in one is an excellent idea. I would not try to fix or go into the inverter unless you want to do that just to learn, but the cost doesn’t make it worthwhile. Inverters like that are good, but only last limited time, it has met its stress limit. Aloha my friend.👍

  • @timlochner9147
    @timlochner9147 2 години тому

    Use a dvom to get the true voltage with a load

  • @budmartin3344
    @budmartin3344 4 години тому

    Does Power Queen has bluetooth that let you look at the Voltage of each cell?

  • @howardescoffery4950
    @howardescoffery4950 4 години тому

    My brother seriously it should have worked we literally have similar system and my Reliable cuts out at 57v. I would really love to see the measurement of each cell, that is why I went the DIY rote. If one cell isn't keeping up with the others you could have normal reading but when a load is put on it, it can't keep up. I would pop it open, why? Even a loose bolt can make a world of difference. Diy is the best it really allow you to monitor your system at the micro level plus the truth is I can't afford all them fancy equipments. Go ahead try the all in one and see what happens, it would allow you to see whether it is the battery or the inverter.

  • @kevinmills5293
    @kevinmills5293 5 годин тому

    Not sure but maybe the battery is 15S and not the usual 16S and the absorb voltage is too high and you are getting a BMS over voltage disconnect.

  • @garyenwards1608
    @garyenwards1608 5 годин тому

    I'm having a similar situation with a 12 Volt 1000 watt Xantrex ProSine Inverter. I think we are triggering the BMS overload shutdown and the voltage is spiking as the CC cant clamp down as fast as the BMS. This momentary spike is triggering higher than the Inverters can handle. Boosting at 14.4 Volts for 100 minutes ( It overloads the inverter about 30 mins- 1 hour in) I never see the voltage on my battery monitor go over 14.6 Volts but the Xantrex is rated for 16 Volts. The MT50 showed a spike to as high as 32 Volts!!!

  • @jadu79
    @jadu79 6 годин тому

    Could it be that there is an imbalance so that one cell exceeds the maximum and the BMS disconnects the entire battery? if you can remove the cover and measure the cells separately with a multimeter because you cannot read the volts on the cells via the BMS? it is enough that one or some cells are too high voltage so that the protection kicks in while others are still in the flat phase. Then you can set how fast it should charge to about 5-10 Amps so that it doesn't give full charge all day when it's enough that it's full when the sun goes down

  • @mjp0815
    @mjp0815 7 годин тому

    Inverter is almost certainly toast. if the battery charges to 58v it should be fully balanced unless the BMS is faulty, which is very unlikely.

  • @sparkletornado5890
    @sparkletornado5890 7 годин тому

    The battery is not absorbing any current during the absorption phase because it has opened the charge relay. It is effectively inactive if it uses a passive balancer that only operates during charging. It's unlikely that it has an active balancer. It would help if you operated the battery according to Power Queen’s specifications, which are 54V ± 0.75V. This is the optimal range for when the charger turns off. There’s no need to push the battery to a point where the cell overvoltage protection activates.

    • @kevinmills5293
      @kevinmills5293 5 годин тому

      Yes, that sudden jump looks like a BMS over voltage disconnect.

    • @chrisreynolds6331
      @chrisreynolds6331 57 хвилин тому

      I was thinking that last night. I've been scratching my head for a couple of days over this mystery. I concluded that the only likely explanation was the BMS was going into full charge disconnect. The victron controller would see the battery disappearing, hence the spike, then it stops charging and the BMS switches back on again.

    • @chrisreynolds6331
      @chrisreynolds6331 55 хвилин тому

      ​@@kevinmills5293must be. It would be impossible for a LiFeP04 battery to jump from 56 to 58 volts in a second if it was actively connected 😂

  • @jw3843
    @jw3843 8 годин тому

    I can say that no name breaker was disconnecting due to heat on the inside. They do not always trip the switch. I do not trust them. Blue sea is the way to go with those type. I think the fuses work as designed.

  • @kennethwilson8633
    @kennethwilson8633 8 годин тому

    You should send the inverter in to have it examined.

  • @johnussss
    @johnussss 9 годин тому

    Thanks for the video, have the older Epever 40a without the Lithium settings included, I have a 24v flooded setup with this same controller, the batteries are near the end of their life, will be buying 2x 12v lithium batteries that are suitable for series connection, can anyone tell me if you simply doubling the charge parameters for 24v, there is very little online about setting up the older controllers for 24v lithium. Can I ask why people setup these chargers for 12v when doing so halves the total Watts you can supply the charger from the panels, if this setup had 24v battery you would only need one controller as it would be able to use the wattage and voltage from all the panels you now have and 24v systems transfer the current from the charge controller far more efficiently.

  • @junkerzn7312
    @junkerzn7312 9 годин тому

    The 24V system is perfect. The "max battery voltage" summary 28.41, 28.41, 28.41, perfect. That's what we want to see for the 48V system too, but we aren't. Looking at 26:25 into the video, that graph seems to indicate that the BMS has disconnected the battery through that whole period pretty much. The Victron is holding the voltage and then attempting to power the loads but it can't track the loads (charge controllers aren't power supplies, they can't track loads closely). I think the BMS is disconnecting somewhere around 55.1V but its hard to tell from that graph. You have to catch it while its charging (before the battery becomes full)... just as it hits the charge target for the first time each day. You can then zoom in the graph and see what voltage the battery was at just before it disconnected and kicked straight up to 56.8V. I found the guide on Power Queen's site. Lets see if youtube lets me post the url. I'll do it without the prefix. "ipowerqueen.com/blogs/blog/how-to-charge-lifepo4-batteries". The chart on that page is very clear. For 51.2V battery series, the best charge voltage target is 57.6V and the charge voltage range is 56.8V to 58.4V. Now note, THEY ARE WRONG! The best charge voltage is 56.8V, not 57.6V. 57.6V is 3.60V/cell which is unnecessary and the BMS disconnect is at the top-end of that scale (when the cells are in balance). 58.4V is 3.65V/cell and that is where the BMS would normally disconnect if the battery is fully balanced. But it is best to use 56.8V as the charge target because you don't want the BMS to disconnect and create inverter problems. So I'm still at "why is the powerqueen not balancing?". -Matt

  • @brushbum7508
    @brushbum7508 9 годин тому

    Good Evening ! I'm catchin up on these older Vids whenever they come into the feed. TAKE CARE..

  • @rickharold7884
    @rickharold7884 9 годин тому

    I think the inverter is toast. I’ve had similar issues with inverters where they start operating oddly aloha.

  • @johnkirby6547
    @johnkirby6547 9 годин тому

    I am curious to see what you find out with this problem. Sounds like inverter to me..

  • @ItsEverythingElse
    @ItsEverythingElse 10 годин тому

    Not to nit-pick, but is this really considered "balancing" or is it "calibrating"? Balancing is typically used as a term for balancing raw cells. Like I said, nit-pick.

    • @junkerzn7312
      @junkerzn7312 6 годин тому

      The BMS is balancing the raw cells, but it only does so for cells in the exponential part of the charge curve (roughly above 3.45V). If you don't have access to BMS settings the industry standard is to charge to 3.55V/cell (3.55 x 16 = 56.8V) to ensure that the BMS in the battery is able to balance the raw cells.

  • @neomatrix2722
    @neomatrix2722 10 годин тому

    This is super cool and thank you for sharing I'm just getting into the victron ecosystem and getting away from Schneider Electric

  • @anthonyrstrawbridge
    @anthonyrstrawbridge 10 годин тому

    1) VE smart Controller is functioning perfectly. The sudden voltage indication tells us this: The Power Inverter has an internal failure; likely in the Power Supply circuit. Can you fix it? No! The circuit board is heavily populated with electronic components which require experience to troubleshoot because of difficulties isolating circuits. Probably - most likely the original fault occurred in one single capacitor located in the DC Power supply voltage regulation circuit. Now, stray voltage is finding the path of least resistance amongst the heavily populated board. That said don't waste the time and energy trying to repair it because the easiest most effective path is to substitute a known good. However, these types of Power Inverters do not usually have multiple separate boards so the user needs to replace the entire Power Inverter. Disassembly of it is relatively simple using basic hand tools. You must remove all power and wait ten minutes. Once you remove the case: Locate the the DC in circuit. Follow it closely with the eye and nose; your looking for three easily identifiable observations 1) Smell for fresh oil and or burnt smell. Often, fish oil is used. 2.) Look and feel for the thin clear oil closely. 3) Look for Carbon Tracking between the circuits/traces on the board. 4) Remove oil by wiping the board down with alcohol and paper towels. Remove all carbon tracks using a rubber pencil eraser. Replace the leaking capacitor. Hopefully the stray voltage didn't damage any diodes. The diodes and capacitors are easy to test if you are capable of removing components and soldering. 😊

  • @kidcymucks
    @kidcymucks 10 годин тому

    Do you have a 48v charger that could provide a constant voltage to charge the battery for 24 hours to ensure it balances the cells? I'm guessing the battery doesn't have a communication port to connect a pc and view each cell voltage.

    • @junkerzn7312
      @junkerzn7312 8 годин тому

      Or put a second 51.2V LiFePO4 battery in parallel with the PowerQueen. If the problem goes away, its the BMS in the PowerQueen.

  • @stevenshircliff393
    @stevenshircliff393 11 годин тому

    Still betting on inverter problem. Cnswipower makes great inverters.

  • @junkerzn7312
    @junkerzn7312 11 годин тому

    Invaluable information. This is a tough one. The BMS is definitely disconnecting on the charge controller and the charger controller is over-volting for a second or two when that happens, then trying to follow the load while the BMS is disconnected and over-volting repeatedly while the BMS is disconnect while there is a load. So now the question is... at what point does the BMS disconnect? To determine that you have to look at the graph again but with a 30 minutes or 1 hour time frame rather than over a few days. i.e. so you can see the actual charge curve at the end, spread out in time. (and you have to do it within an hour or two of the event to get high resolution data). If you view the high resolution data each day with just 30 minutes or 1 hour resolution, and take a photo of it, we can determine if the battery is making progress or not on the balancing but more importantly we can determine exactly at what voltage the BMS is disconnecting during charging. The charge curve will look normal up until that point, going exponential near the end of the charge, but then going literally straight up when the BMS disconnects. Lets see where the BMS is disconnecting each day. In high resolution. My feeling is... I'm still not sure whether this battery is 15s or 16s but I think it must be 16s because it settles at roughly 53.0 - 53.3V or so after sundown when there's a load on it, which is precisely the voltage range where I'd expect it to be for a 16s pack. So perhaps one cell in the pack is just badly out of balance. -- When the BMS is connected and operating normally, and the battery is balanced, the last part of the charge curve just before the charge target is hit should see roughly 0.01V to 0.02V per second of rising voltage. 10 seconds to rise 0.1V to 0.2V, roughly. Assuming a 0.2C charge rate. This is why clouds going in and out or changes in the load just shouldn't be causing the voltage to rise all the way from 56.8V to 58.0V+. It should only be able to cause that to happen if the BMS disconnects prior to the charge target being reached. If the BMS is working properly, going from 56.8V to 58.0V would take about 2 minutes at a 0.2C charge rate. The charge controller should be able to react far more quickly than 2 minutes... the charge controller should be able to react within 10 seconds. -Matt

    • @offgridwanabe
      @offgridwanabe 10 годин тому

      I think it spikes when the charge controller sees a need for float voltage to turn up the amps from the solar (when load is turned on) and since there is no room between the charge target and the float voltage it spikes a shut down voltage.

  • @robertmeyer4744
    @robertmeyer4744 11 годин тому

    I do not see a HV spike that would trip inverter until you switch it on, Then it does some weird spikes when inverter acts up then shuts off. Starting to look more like a inverter problem , just swap inverters. if same problem than you know battery. without measuring each cell ,it is hard to say if it is a balance problem.

  • @1GREATDANE
    @1GREATDANE 11 годин тому

    Would a Ground Help the Inverter any ?

  • @scotth9984
    @scotth9984 11 годин тому

    I'm new so sorry if this is a dumb question. But doesn't power queens bms supposed to properly balance the cells? I know from reading if you run in series and the batteries don't have communications back and forth, but I thought one battery was a no issue with balancing.

    • @junkerzn7312
      @junkerzn7312 7 годин тому

      Yes, but it will only start balancing the cells above a certain voltage. If the charge target is set too low, the BMS never has a chance to balance the cells. And if the target voltage is not held long enough before dropping to float, the BMS might not have enough time to keep the cells in balance. The charge curve is too flat to be able to balance the cells at lower voltages. The BMS would wind up either not making any progress or making the wrong choice (unbalancing the cells instead of balancing them).

    • @scotth9984
      @scotth9984 13 хвилин тому

      @@junkerzn7312 Right, but he started having problems because he had the voltage where it needed to be, and as a result the converter was tripping. After, in order to lose the faults, he walked back the voltage and it started working.

  • @Techboxreview
    @Techboxreview 11 годин тому

    This may be a silly suggestion. Try turning the Victron controller off. Then power the inverter on with only the battery. It would be interesting to see what happens. May be the Victron causing the voltage spike that is shutting the inverter down. Process of elimination as you will 🤙🏻

    • @mjp0815
      @mjp0815 2 години тому

      The battery has very little capacity at the higher voltage and will drop instantly without the charge controller running... If you have a variable dc power supply, you could test the inverter shut off voltage with that properly.

  • @WattsinWattsout
    @WattsinWattsout 11 годин тому

    Maybe the victron is doing the over-volting? 61 v spike could trigger the inverter protection. Do you have another 48v charge controller to test with? Lower charge voltages and see if the inverter over volts. There are potentiometers in there for dc and ac voltage adjustments. They usually blob hot glue or silicone on them to keep them from moving.

  • @margarita8442
    @margarita8442 11 годин тому

    is that from victron smart shunt ?

  • @offgridwanabe
    @offgridwanabe 11 годин тому

  • @kathleenmaurici1158
    @kathleenmaurici1158 11 годин тому

    Great video

  • @garyenwards1608
    @garyenwards1608 11 годин тому

    I'm dealing with a very similar situation. I have two 40 amp Tracer EP Ever CC feeding a 200 amp Ampere Time 12 Volt battery. I was Boosting at 14.2V for 100 minutes and Floating at 13.8V no issues. Then I decided to do a monthly BMS balance by changing Boost to 14.4V for 120 minutes. I came back to the system and the Xantrex ProSine Inverter was flashing green Voltage Overload and not powering the fridge. I checked the MT50s daily Battery range and it was 32 Volts peak and 12 Volts Low. I figured the BMS had triggered, rebooted the Xantrex and carried on. Now I've had the same thing happen when in Boost 14.2V for 100 minutes. I was sitting and watching it when it did it and it was a momentary surge to around 28 Volts. MT50 shows similar 28 Volt peak 12 Volt Bottom. The next day I changed Boost to 14.1V and 90 minutes. Wasn't very sunny and haven't had it happen in the last few days. I suspect it happened the second time at 14.2 Volt Boost because the battery was already really charged up from the 14.4 Volt Boost day. Now I'm thinking adjust it to 14.2 Volts 100 minute Boost when not soo sunny and 14.1 Volts 90 or 100 minutes when lots of sun... Kind of a pain in the ass to be physically changing the Boost settings on both CC all the time. The battery and systems only been in play since April. The battery did sit unopened for 20 months before I started using it

    • @garyenwards1608
      @garyenwards1608 10 годин тому

      I've set both CC at 14.1 Volts 30 minutes Boost and 13.8 Float. Ill see how that does and maybe once a month change them to 14.2 Volts Boost or 14.4 Volts for what amount of time I'm not sure yet. Maybe 14.4 Volts once a month for 10-30 minutes with the inverter turned off shortly before peak sun. I'm not sure but I think the BMS might balance at 14.2 Boost Voltage and not require going all the way to 14.4 Volts. Many conflicting opinions on this. Addendum: Spent the last 4 hours reading on this. I might try setting the Boost to 14.2 Volts and Zero Absorption time after testing out 14.1 Volts 30 mins Boost/Absorption time for awhile. LIFEPO4 batts don't like to be held at 100% SOC like I've been doing and going to 14.2-14.4V with zero absorption time will allow for a 90-95% SOC. I'll try taking it to 14.4 Volts for 5-15 minutes once a month for BMS balance. If I try the 14.2-14.4V Boost with Zero Boost/Absorption time I might reduce the Float to 13.6V from the 13.8V I've been using. I'm in Northern Canada where we don't get a lot of sun much of the year so a higher Voltage can make sense. In a sunny climate a lower Voltage makes sense. There's a lot of good comments in this balancing video Andy The German made. Andy and commenters are using 13.8 Volts Boost and 13.4 Volts Float. Andy's testing out 14.2 Volts Boost in this video for balancing. The manual for my Ampere Time battery recommends a SCC Boost setting of 13.8 Volts with 120 mins Boost/Absorption time and a Float of 13.8 Volts. They also recommend an Equalize charge Voltage of 14 and a duration of 120 mins... Not too sure about that ua-cam.com/video/OpEQ4fV7-ZU/v-deo.html

  • @TheSimpleLivingAussie
    @TheSimpleLivingAussie 12 годин тому

    you got me looking at my Victron app history 😂

  • @lifehunter6426
    @lifehunter6426 15 годин тому

    I have been on the fence about getting these batteries, but the reviews seem good, and Will Prowse says they are good. They are on sale. I can get 3 280ah chins for $1187.00 I don't think I can pass that up

  • @benoitbenoisbenoistchaine
    @benoitbenoisbenoistchaine День тому

    You funny cats ok 😅 changing my breakers 50 amps main breakers .only using 1200 watts 12 volts system .. keep my 100 amps breakers for back up in case. Crazy .. I don’t want van go up in flames

  • @1GREATDANE
    @1GREATDANE День тому

    🌴 Lemonade Aloha 🤙

  • @ryancaesar5547
    @ryancaesar5547 День тому

    Hi and how are you doing. I had a couple of those reliable inverters and they didn't last, overtime they just stop working and what alway happen is the voltage regulator malfunction are the power mosfets gives out so I just got rid of them. Well as you said it server you for couple of years.

  • @symonsaz8496
    @symonsaz8496 2 дні тому

    So who is the winner? Which brand to choose? Thanks.

  • @sparkletornado5890
    @sparkletornado5890 2 дні тому

    I’m still unclear why you’re not using the rated charge voltage of 54V for that battery. My 48V batteries reach 98% SOC at 54V, which should be sufficient. If you look at the specifications for large server rack batteries, such as the Pylontech US5000B, they have charge voltages between 52.5V and 53.5V. When the BMS stops charging, it indicates that one or more cells have exceeded 3.65V. An immediate charge disconnect could cause a voltage spike in the inverter.

  • @HolWol24
    @HolWol24 2 дні тому

    Why don't you charge the battery until it switches off? And then unscrew the battery case cover and measure the individual cell voltages with a multimeter?

  • @1kzrider
    @1kzrider 2 дні тому

    Man I like you found victron to be amazing. Between going to victron and away from lead acid to lithium my same panel setup is more than double it's previous power. I will keep my other controllers around if ever need as back up though.

  • @dons5105
    @dons5105 3 дні тому

    Also can you hook up one of your regular batteries to your solar generator to expand your gas tank?

  • @dons5105
    @dons5105 3 дні тому

    Why is your 800 wtt inverter larger than your 1600 wtt all in one solar generator?

  • @JohnWick-xz9tc
    @JohnWick-xz9tc 3 дні тому

    check with @GoingOffGrid101 . He does alot of work with that brand.

  • @1GREATDANE
    @1GREATDANE 3 дні тому

    I Like that You Refer back to Your Trusty 24 Volt System to Stay Running - I am Running 4 24 Volt Systems here @ Indian Creek Ranch of Southern California High Desert 🌴 💦 🌵 Aloha ⛩

  • @junkerzn7312
    @junkerzn7312 3 дні тому

    With a few days of cycling under your belt you can look at the Victron "Trends" graph and see the voltage where there BMS disconnects up (because it won't look like a normal charging curve, the voltage will more or less shoot straight up and then oscillate around the charge target). Unfortunately Victron only keeps a few hours of high-resolution data, but you can still get an idea about its balancing progress. The voltage it gets to before it suddenly shoots up should (theoretically) get better and better each day when it is making progress balancing, until eventually it stops shooting up vertically at the end and just looks like the normal exponential ramp. An oscilloscope is really needed to see the BMS disconnect because the whole thing happens in about half a second... the voltage overshooting and then returning to the charge target. That process is less than a second. But will keep happening if there is an inverter load. Volt meters and the Victron monitoring display average the voltage over a second or two and can't catch it completely. Another way is to look at the "History" tab of the Victron charge controller. It shows the "max" battery voltage each day. In a properly working system that fills up to 100% that voltage will be precisely the charge target. In a system where the BMS disconnects, that voltage will be significantly higher and also vary a lot each day because of the averaging it does. In your video at 7:59 we can (barely) see the Battery "max" and it does seem to be bouncing around a lot. Though that might also be due to you changing settings. -Matt

    • @offgridwanabe
      @offgridwanabe 22 години тому

      I agree the bms is only doing what it is programmed to do.

  • @foreignerescapestothephi-lj3ls

    Your batteries are full. Why are you still messing with them? If it ain’t broke don’t fix them!

  • @robert4027
    @robert4027 4 дні тому

    I love victron

  • @houseofancients
    @houseofancients 4 дні тому

    Bob , i can almost guarantee this is an internal cell balancing issue, and has nothing to do with your inverter. Best way to solve this ( and this will take a while, since the BMS only has a 200mv passive balancer that only works when charging). 1. Disable tail current 2 set charge voltage to 56 and set absorb to minimum of 5 hours If the BMS doesn't shutdown, change charge voltage to 56.8 and again absorb for 5 hours, if BMS does shutdown, discharge about 30 amps and repeat step 2 untill it doesn't shutdown anymore

  • @Sharefoon
    @Sharefoon 4 дні тому

    If it doesn't work, why not build another 48v bank with the previous 4 batteries you had with the balancer on and try and isolate the problem to the battery, charge controller or inverter?