How to Install a Chimney Pipe Roof Flashing

Поділитися
Вставка
  • Опубліковано 16 сер 2024

КОМЕНТАРІ • 183

  • @GGFlytyer
    @GGFlytyer 11 років тому +4

    Oh BTW that is a really great video,, thank you so much, I've got all the pipes and fittings ready,,My concern was cutting the hole in the roof and you are a GREAT help , thanks again for taking the time to make the video

  • @fisherman695
    @fisherman695 4 роки тому +4

    Great vid...,, looks identical to my situation on garage roof so very helpful.., thank you for taking time.

  • @Deltaconcepts
    @Deltaconcepts 11 місяців тому

    I love hearing the kids terrorizing the neighborhood in the background. LOL I am going to do this soon. I have watched this vid like 10x. I should be able to do it thanks to you.

    • @mrEnergy511
      @mrEnergy511  9 місяців тому

      Awesome! I love hearing this! I hope it goes smoothly. We live in Utah....there are kids everywhere.

    • @Deltaconcepts
      @Deltaconcepts 9 місяців тому

      @@mrEnergy511 I did it thanks to your help. No leaks yet. X fingers

  • @Gstonesheat
    @Gstonesheat 10 місяців тому

    What a perfect how to video. Thank you for posting this.

  • @GGFlytyer
    @GGFlytyer 11 років тому +1

    I live in CT when I put a pellet stove in my garage/workshop the code here was that the bottom of the firebox had to be a minimum of 18" off the floor in case of fumes. that was with the "exhaust pipe" through the side wall. Pellets were way to expensive, so now putting a wood stove in and just to make sure I will build it up on cinder blocks,, oh and my floor is concrete and that's what the building inspector told me to do to pass code

  • @8311XHT
    @8311XHT 7 років тому

    Thanks mrEnergy for putting up your vids. I installed the ceiling support box, now I need to go up in the attic and plumb bob for the center where I will put the screw through and out the roof. I made a cardboard template for the hole in the roof to trace out. My roof is pretty steep so I made it elliptical so the clearances will be right on top and bottom.*One thing though is that the strapping you did won't work because the wind will still blow it down. I'm gonna use a metal strap and rods all bolted everywhere so it won't ever go anywhere.

  • @mrEnergy511
    @mrEnergy511  11 років тому

    Thank you! Thats how you do it with class 'A' chimney pipe, run it straight through your roof and flashing, seal it up and put a chimney cap on it. You will be ready to go! On your single wall black stove pipe there are connector parts that are crimped on both ends. Use one of these and push it into the Chimney pipe.

  • @TheRealMonnie
    @TheRealMonnie Рік тому +1

    My dad told me to not put the roof caulk underneath of the flashing towards the bottom end so if any water does get in it could drain out.

    • @mrEnergy511
      @mrEnergy511  9 місяців тому

      Always honor your father and mother but the hope is to not get any water in at all.

  • @mrEnergy511
    @mrEnergy511  11 років тому +4

    Yes I do! Nail or screw down both sides and the bottom. Don't nail the top of the flashing, and you can't use to much roof tar! Rember to use High Temp silicone for the pipe collar. Thanks for your comment!

    • @peterbarlow8912
      @peterbarlow8912 8 місяців тому

      Thick roof cement will dry up and crack like a mud flat. Seen many cases of a cracked thick cove of tar burying the siding/step flashing interface. It has to be removed to roof over. We used to joke that you should need a license to apply roof cement.

  • @jasonriek9075
    @jasonriek9075 Рік тому +1

    Thank you so much! This is so helpful!

  • @ccervantes
    @ccervantes 9 років тому +11

    The flashing is facing the wrong side of the slope. That's why you ended up with a big gap under the storm collar, and ended up with not enough pipe clearance on the lower side of the roof. Also, you forgot to seal your nails and the bracing you installed only supports the pipe in one direction. To all those watching this video: this is not a professional installation.

    • @bobbarnes5774
      @bobbarnes5774 9 років тому +3

      Cesar Cervantes why don't you make a video. This wont leak

    • @pierreverdoni
      @pierreverdoni 4 роки тому

      LOOK at the videotop slope is soft lower slope has a 90% angle ....water will not flow nicely with the bottom side on top!! ...get it NOW??

    • @ccervantes
      @ccervantes 4 роки тому

      @@pierreverdoni The softer slope would make the water flow nicely indeed, but that softer slope also puts the collar closer to the roof, which will allow for some water (or snow melt) to flow unto the collar, thus increasing chances for leaks. If the higher side with a near 90 degree angle, as you pointed out, is on the top side of the slope, this puts the collar further away from the roof, and because the flashing is a single piece of welded metal it wont leak at the 90 degree angle. Water will just go around it. Look at large bridges and how they build the bases with sharp concrete blades that break up the flow of the water. You don't want an easy slope for the water to run through. You want a sharp yet waterproof angle to make your water go around your flashing and away from any joints that may be more susceptible to leaks.

  • @mrEnergy511
    @mrEnergy511  11 років тому +1

    Hey no problem! I love installing Fireplaces and wood stoves! I'm glad I can help people save money by DIY.

  • @bannerelkglassart433
    @bannerelkglassart433 5 років тому

    I need to make sure that I do this right. I can't pay anyone to do it. So I'm just gonna watch more viedos . For a little shop shed/tiny house wouldn't mind having it a little off if I did but I still aim for perfection. Just gonna keep watching vids. Some of the commenters who say they can do it better should post some vids

  • @charlenenorman3644
    @charlenenorman3644 4 роки тому

    I like how your being careful with the roofing. Excellent video

  • @dbwesner9229
    @dbwesner9229 5 років тому +8

    This is an example of what not to do.

  • @l07smitty
    @l07smitty 11 років тому +2

    Thanks for this video Mr. E! You are giving me the balls to possibly do this.

  • @jerryheilman
    @jerryheilman 11 років тому +2

    The positioning of the flashing was ideal in my opinion, 1/2 way up most any flashing.

  • @nickpanhead7209
    @nickpanhead7209 Місяць тому

    Nice job. You made it look so easy. Did you renail those shingles that you took out on the upper side of flashing, or did you just caulk the shingles back down. How many nails are you putting in flashing. And are they 1" roofing nails. I never did this type of job, but i know i can do it. I been looking at different videos. Some guys i seen dont put a beed of caulk on the bottom of the flashing. Im just not sure about that also. Im in a high wind, and i do get heavy rain from time to time. What type of caulking are you using, I installed a furnace in my garage, and this is the last thing i have to do. My stove pipe parts are coming this week. Do you have any other video of you doing more of these. Thank you. If you could just answer a few of my questions, i would appreciate it.

  • @mrEnergy511
    @mrEnergy511  11 років тому

    I always use a support box when installing chimney pipe for a wood stove! This install is actualy a built in pre-fab fireplace. The Chimney pipe connected directly to the Fireplace and went up from there. The Fireplace supported the Chimney pipe. Thanks for your kind words.

  • @spatialtherapy6364
    @spatialtherapy6364 7 років тому +1

    Very helpful, thanks

  • @landonlandon5533
    @landonlandon5533 Рік тому +3

    Flashing tape is recommended for the top. A little added security to keep the rain out. Caulk the exposed nail heads too.

    • @mrEnergy511
      @mrEnergy511  8 місяців тому

      Also a good way to make the roof flashing water proof.

  • @mrEnergy511
    @mrEnergy511  11 років тому +2

    DUDE! When you slide the flashing under the shingles lar the hell out of it and put extea roof tar under the shingles you pulled up. If you really want to nail the top lift the top layer of shingles and just go up under the shingle a 1/2 inch so when it lays down the nail will be covered by the top shingle then pot some tar under that and press it down. Hope that helps your balls drop! LOL

  • @grady9752
    @grady9752 5 років тому +7

    Could someone please explain what several commenters have stated regarding the placement of the roof flashing? "The flashing is facing the wrong side of the slope" and "omg....upside down?" Are they seeing something I'm not? His installation isn't "upside down." What am I missing here?

    • @PackardDog
      @PackardDog 3 роки тому

      looks installed correctly to me.

    • @74o9i27
      @74o9i27 3 роки тому

      I think the "'up-side' down" comment(s) is referencing that the flashing's seam is facing downhill vs facing upward. This particular chimney pipe flashing's seam, seems to have been manufactured to face uphill(?).

    • @robshaver2634
      @robshaver2634 3 роки тому

      The flashing is installed backwards. Seriously

  • @VideoLife_FPV_Wild
    @VideoLife_FPV_Wild 3 роки тому

    Thank you. Tomorrow i will do the same.

  • @TauqirIlyas
    @TauqirIlyas 4 роки тому

    Thanks for sharing this video. It’s very informative.

  • @UltimateCarnage
    @UltimateCarnage 11 років тому +1

    that was funny when you pointed out there stupid dish at 9:44
    "hope there tv doesn't work" lmao

  • @countryprepper4719
    @countryprepper4719 5 років тому

    Nice work 👍👍

  • @tdgreenbay
    @tdgreenbay 3 роки тому +1

    They can watch TV... the sat signal comes in from the left of that dish anyway...

  • @North700
    @North700 11 років тому +1

    Great video !! very helpful

  • @rickbelfry7234
    @rickbelfry7234 2 роки тому

    good instruction thanks!

  • @webhead7204
    @webhead7204 2 роки тому

    Looks like Eagle Mountain, UT!

  • @kopronko
    @kopronko Рік тому

    Thank you .

  • @bendouglas7811
    @bendouglas7811 2 роки тому

    Thank you sir.

  • @abdellatifjaidane858
    @abdellatifjaidane858 8 років тому

    thank you very detailed video

  • @byron2521
    @byron2521 4 роки тому

    All these flashing videos I have watched show just silicon caulking the storm collar. Although you should caulk it as a backup, that is not the recommended way to do that. There should be a larger diameter pipe that slips over that chimney and rests on the storm collar. This way NO water ever comes in contact with the seam between the storm collar and the chimney.

  • @khurshidanwar9923
    @khurshidanwar9923 11 років тому

    nice picture quality, nice sound great job in less time. Thank you.

  • @tonymarony1
    @tonymarony1 11 років тому

    I am a professional fireplace installer and you could of put the roof flashing under 2 more rows of shingles. The strapping will not hold under high winds, use ridged pipe supports. You don't need the red RTV any 100% silicone will work. The hearth pad you built will crack as the base is on top of carpeting. Remove the carpeting lay cement board down then go ahead with the hearthstones. Make sure you have enough front protection, usually 16"-18".

  • @erickwardwell962
    @erickwardwell962 6 років тому

    Your putting it that close to the satellite dish.

  • @broncomke
    @broncomke 10 років тому +1

    Thank You!

  • @l07smitty
    @l07smitty 11 років тому +1

    Should we re-nail the shingles at all?

  • @neilshurmur3901
    @neilshurmur3901 6 років тому

    Nice Job

  • @desire4liberation
    @desire4liberation 4 роки тому

    stupid tv is right!! thanks... now get over here and help me do that LOL

  • @JDoe-hb7pc
    @JDoe-hb7pc 5 років тому +1

    What happened @7:07 like how do you get the pipe in there? Can you do it from the top of the roof or does it require going into the attic "cringe". I'm a woman and the inspector told me my furnace termination is wrong and it needs to be 12" it's currently 6 inches. I need to find a way to make this longer without having to go into the attic.

  • @Lawaviles
    @Lawaviles 11 років тому +1

    My question is, did installing the chimney pipe in front of your cable, Dish Network, sat dish interfere with your TV reception? I want to install one on my roof as well and I wanted to know if it'll cause problems with my sat dish.

  • @Livininalaska
    @Livininalaska 11 років тому +1

    When you nail the flashing down, do you nail the exposed bottom half and do you need to put roof tar over the nails? Thanks for the great vid!!!

  • @VikingPreparedness
    @VikingPreparedness 4 роки тому +1

    Helpful. Thnks.

  • @dwolf97
    @dwolf97 8 місяців тому

    step 1..... run screw though roof from attic....... step 2....... walk around roof until foot bleeds

    • @mrEnergy511
      @mrEnergy511  8 місяців тому

      I sense some sarcasm here.

  • @Spartan1234ish
    @Spartan1234ish 10 років тому +1

    Go under two more rows...all that water coming down the valley...gutter that close to the bottom of the flange. Hole might have been a bit big. Reason I say that is because your so close to the gutter. Heavy rain with back up in that gutter plus a ton of water coming down the valley and no-where to go. Could back up the roof from the gutter and get in under the bottom of that flange.

    • @Spartan1234ish
      @Spartan1234ish 8 років тому

      ***** Your're confused. I'm not talking about the shingles going two more rows under the flange. I'm talking about the flange going two more rows under the shingles. In other words he has to many rows going under the flange and not enough rows going over top of the flange. In this case it's really important because the flange/pipe is real close to the gutter and the valley. Water can back up quickly in a non-functional gutter, non-functional gutter could be as simple as a leaf clogged gutter, therefor the water backing up the valley just enough for water coming down the valley hitting the pond/backed-up water then running around the pond water and in under the flange. Seriously though if you don't understand this your're not really shingle/roofer. If you are a roofer I bet you would be surprised how many leaks you have behind you.

  • @mrEnergy511
    @mrEnergy511  11 років тому +1

    A good amount to roof tar will hold it down!

  • @Livininalaska
    @Livininalaska 11 років тому

    Thanks a bunch for the quick reply!!!

  • @dg3831
    @dg3831 7 років тому

    hahaha, wow. I was really thinking this was Rocket science.

  • @scottchesterhall
    @scottchesterhall 7 років тому +1

    Super helpful. Getting ready to install a wood stove and chimney. Two questions: 1) think I can use a chainsaw instead of a reticulating saw to cut my roof hole? 2) how do you line up your roof hole to the stove pipe coming up to the chimney?

    • @TheExtrAFuN
      @TheExtrAFuN 7 років тому +1

      he used a screw threw the inside of the roof as his center

    • @koolbeans8292
      @koolbeans8292 Рік тому

      Howd that chainsaw work? 😉

    • @scottchesterhall
      @scottchesterhall Рік тому +1

      @@koolbeans8292 awesome actually. LOL. For real. Just had to air out the house real well! Been burning this stove hot for 5 years now!

  • @patrickpeterman8736
    @patrickpeterman8736 9 місяців тому

    "very well done when you added the extension flue pipe to the existing flue pipe -did you just slip the extension over the existing flue pipe =just a slip on and push down: thanks PJP

    • @mrEnergy511
      @mrEnergy511  9 місяців тому

      Not sure exactly what you asking. Each brand of pipe has a distinct connection.

  • @frankerling2175
    @frankerling2175 Рік тому

    Great video, however, it appears the flashing is on backwards, the chimney would center on the opening if you turned it 180

    • @mrEnergy511
      @mrEnergy511  9 місяців тому

      The roof flashing may appear backwards but it is installed correctly. If it wasn't the flashing would not lay flat and the pipe would not be level.

  • @cptnothingspecial6127
    @cptnothingspecial6127 5 років тому +1

    You forgot to put Henry on the nails on the flashing

  • @4leeandtracey
    @4leeandtracey 11 років тому

    Thanks for the great video it was a lot of help.

  • @shananacarrillo
    @shananacarrillo 9 років тому +1

    why didn't you show us how you connected the last piece of chimney piping to the existing coming from the bottom?

  • @l07smitty
    @l07smitty 11 років тому

    Lol, thnx dude. I did ALOT of measuring last night. Do you know what code is for how far the firebox must be from the ground in a detached garage and for just a workshop? Im concerned now due to my low ceiling and stove stating 55" clearance. ....ugh, lol. Thank you Mr. E!

  • @ryanfifield8239
    @ryanfifield8239 10 років тому +3

    What is your plan with the blown insulation you left with no insulation shield? Insulation also carries a 2 inch clearance and loose blown in tends to not stay put

  • @jakeb1778
    @jakeb1778 Місяць тому

    Do you cover nails with tar/sealant?

  • @gmmcl
    @gmmcl 11 років тому

    I am putting in a chimney support box. It is square and penetrates the roof. My flashing is round. Do I cut the hole in the roof round or square?

  • @mrEnergy511
    @mrEnergy511  11 років тому +1

    If your Wood Stove is set on concrete ZERO clearance! You will need to be 24" off the back to a combustable wall... Also you may want to build a heat sheild wall... Good luck!!!

  • @tonymarony1
    @tonymarony1 7 років тому +17

    You should of put the roof flashing under 2 more rows of shingles so you don't see the flashing so much. Throwing nails in the attic is sloppy. You need solid chimney support rods not plumbers straping. Who trained you?
    This is my field of expertise.

    • @aztekwarrior518
      @aztekwarrior518 6 років тому

      tonymarony1 it bothered me that the pipe wasn't centered in the flashing.. I've been watching these vids for a few weeks planning my personal installation...seems like less risk of leaking from the storm collar if it was all centered up evem..is that wrong ?

    • @BGnLA1
      @BGnLA1 6 років тому

      May I ask a question tonymarony1.. Is having a Chimney :Stucco & frame covered 3 wall pipe good material. I'm in process of purchasing a home. This came on report and Inspector says it was a good thing..?

    • @fathertime5680
      @fathertime5680 5 років тому +5

      This guy still knows everything about everything yet doesn't put his own video out, but comes home from installing stove pipes all day and then sits in front of the computer to analyze everyone else. Look all I'm saying is, if your so much better then shut up and show us. Trust me I want the best video but not a know it all who is too scared to make a great video for us like he claims he's the best pipe installer in the states

    • @fathertime5680
      @fathertime5680 5 років тому +2

      Let me explain from another angle. I know that I'm great at my profession so there's no need for me to watch people trying to do my job better. I don't need to that reassurance because I just know. So Why are you? maybe you're not as confident as you want people to believe. Maybe your secretively lacking on your side and want to be Mr. Know it all on the computer on your wife's couch

    • @parkerparker7833
      @parkerparker7833 5 років тому

      How does the top come off a metal chimney

  • @omrishooshan9784
    @omrishooshan9784 5 років тому

    hey, i have a question. my roof is made only with a panel of two aluminum boards and polyoritan beween them, without shingles. im planning on installing my chimnney ,if i'll use the roof flashing can i glue it stright to the aluminum ? i figured it has to be strong but screwing it will create a possible leak problem... my apologies for any spelling mistakes, english is a second language to me

  • @zedac0sta
    @zedac0sta 11 років тому

    Awesome video man, thanks.

  • @mrEnergy511
    @mrEnergy511  11 років тому +1

    I know what you mean! It's a hard thing to cut a large hole in your roof not knowing if it will leak or be damaged! Just keep in mind you can allways hire a guy if you mess it up too bad!!!

  • @davecollier8054
    @davecollier8054 6 років тому

    Nice!

  • @chuckhammond8266
    @chuckhammond8266 5 років тому +7

    It would have been helpful for the DIY person to see the job through to completion; nails, caulking. etc. until completely done...

  • @vmvmisty
    @vmvmisty Рік тому

    Thank you for the very informative video.I have a roof window 2 feet at 2 o’clock direction from my stack. How high does the stack need to be?

    • @mrEnergy511
      @mrEnergy511  9 місяців тому

      Sorry for the late reply...playing catch up! The rule is 2' above anything 10' away.

  • @NCIcaucus
    @NCIcaucus 5 років тому

    I am doing this up on a cabin that doesn't have an attic space. What can I use on the inside to stabilize it? I'm thinking something to attach to the 2 x 4's. Thanks

  • @markgechter4965
    @markgechter4965 Рік тому

    Is their a code#or code reference #for this installation procedure

  • @justtruth8310
    @justtruth8310 Рік тому

    How did you seal the roof straps? Also how did you seal the nails on the flashing? thanks

  • @elizabethvillalobos8927
    @elizabethvillalobos8927 2 роки тому

    Great job. What did you strap the straps onto?

  • @mrEnergy511
    @mrEnergy511  11 років тому

    Welcome! Keep warm with your Wood Stove.

  • @Cheesefungus632
    @Cheesefungus632 Рік тому

    Do you put the flashing underneath the underlayment aswell? Or just the shingles?

  • @coldspring624
    @coldspring624 5 років тому +6

    omg....upside down

  • @l07smitty
    @l07smitty 11 років тому

    How come the top flashing doesnt get nailed down by through the shingles and then through the flashing? Do you ever put an extra layer of flashing down like the flashing sheet for your "though the wall" support box install video? Sorry for all the questions posted here, i may just hafta send you a donation if I do this myself, lol. Thx

  • @elizabethvillalobos8927
    @elizabethvillalobos8927 2 роки тому

    So there is no need to screw the flash onto the shingles?

  • @ClickinChicken
    @ClickinChicken 10 років тому +8

    lol now they have 'searching for satellite' on screen 9:45

  • @vanle-yw1yo
    @vanle-yw1yo 11 років тому

    Thank you for your video? i am looking for someone install chimney pipe to replace my old chimney, i do not know if is possible .I am living in lowell MA.If anyone knows someone can do it and of course have license will be better.By the way my house is two family units.I have 2 steam boiler and 2 water heaters,thanks

  • @elsbethglass5942
    @elsbethglass5942 9 років тому

    Video on putting top on

  • @dunmoyer260
    @dunmoyer260 11 років тому

    So do you do the same if you have a tin roof? I need to do this on my shop.

  • @alphazed4067
    @alphazed4067 8 років тому +6

    Hope you have millions in general liability insurance. Capped ,strapped and ready to burn the house down. You get paid to do this?
    Wow! In a word (Unbelievable) in two words (Court Room!)

  • @clydewmorgan
    @clydewmorgan 11 років тому

    me too. I was out there flapping till I saw this video

  • @elizabethvillalobos8927
    @elizabethvillalobos8927 2 роки тому

    Finished product ?

  • @ricksturm9701
    @ricksturm9701 8 років тому

    I have a similar installation to do next weekend. My problem is I am going through my eave and it is shallower than yours and I want to include some sort of flashing. Typical flashing would hang over the side. The other part of this that may create an issue is that it is a steel roof. Any suggestions would be great.

    • @vernnewman7787
      @vernnewman7787 7 років тому +2

      on a metal roof you could use a High Temp rubber boot. and then you won't need a metal flashing.

  • @pepelepew2142
    @pepelepew2142 11 років тому +2

    DISH NETWORK SUCKS WITH OR WITHOUT THE PIPE INFRONT!! LOL

  • @elizabethvillalobos8927
    @elizabethvillalobos8927 2 роки тому

    How long would it take a beginner to do this ???

  • @shmedlyshmee
    @shmedlyshmee 11 років тому

    I have a question for you....Did you use a ceiling support box or did you just go right through the sheet rock in the ceiling and use a strap attached to the rafters? If you just went through the ceiling did you use some sort of "beauty ring" on the ceiling around the pipe? Good helpful video! Thanks!

  • @JosephPonikvar
    @JosephPonikvar 6 років тому +1

    How much would you typically charge for a job like this and what part of the country are you in? Also I see some people continue the shingles all the way down to the bottom so only the bottom middle is exposed it seems like that would work too.

    • @mrEnergy511
      @mrEnergy511  6 років тому +1

      John Smiith I'm in Utah. I charge $450 for a fireplace or wood stove installation

    • @tomcunningham8584
      @tomcunningham8584 2 роки тому

      @@mrEnergy511 I’m in Ky (2021 dec) was quoted 2500.00 for 1/2 stove pipe and half class A dbl, plus 1500.00 labor, straight up from stove, total ten feet, ceiling, attic, roof, so here I am diy, thanks for the great info 👍

  • @mrEnergy511
    @mrEnergy511  11 років тому

    I hope it does! We should all un-plug from the matrix as often as we can!!!

  • @josechavez1706
    @josechavez1706 5 років тому +3

    It’s not even installed right on the roof

  • @miiko9378
    @miiko9378 3 роки тому +1

    POP

  • @KJC63
    @KJC63 11 років тому

    we get a itty bitty drip coming down our stove pipe (in our living room)....and its random, sometimes nothing when its really raining...sometimes we get the drip on very little rain...it drips onto the base of the double wall stove pipe on top of the woodstove. The flashing looks correct (looking from the ground)...can we try the roof tar, first before swapping out shingles or flashing? The house (and roof and woodstove) is 8 years old. Thanks!

  • @robertvanderbailes1295
    @robertvanderbailes1295 Рік тому

    Where did you find that storm collar for a big pipe like that?

    • @mrEnergy511
      @mrEnergy511  9 місяців тому

      The storm collar comes with the flashing. Most chimney pipe manufacturers make these large flashings and storm collars.

  • @TheJunnior45
    @TheJunnior45 2 роки тому

    Isn’t the flashing upside down?

  • @BearRidgeSheds
    @BearRidgeSheds 6 років тому +13

    Wow, that really does look like crap.....

  • @chrislayton2025
    @chrislayton2025 7 років тому

    Do you nail down the exposed flashing?

    • @garrimic3
      @garrimic3 7 років тому +1

      Chris Layton .... yes..... but I noticed he didn't use nails with a washer to prevent leaks and he didn't seal the nails used with the roofing tar....
      Better off using roofing screws.... more secure and they come with rubber washers attached to metal washers....

  • @addiefanlow7253
    @addiefanlow7253 6 років тому +7

    This is horrendous! I never understand videos like this. I take pride in the work I do. Whenever I do a project for others, they always ask me why it takes so long, yet when its finished, they stand back in awe of the craftsmanship. I would literally be ashamed to show someone this work, not to mention would refuse to live in this house under that.

    • @CB19087
      @CB19087 Рік тому +12

      This comment says more about you than the guy who took time to make and share it. Maybe you could post a video on how you'd install one? Be interested to know what you'd do differently...

    • @pablo6305
      @pablo6305 Рік тому

      Why. He did it acording to code. What your saying is you overcharge fpr being anal retenive.

    • @jillachen7217
      @jillachen7217 Рік тому

      Awesome job!! Jill from Baudette Minnesota

  • @espositoarnold4508
    @espositoarnold4508 3 роки тому

    YOUR MECHANICS WERE GOOD, JUST VERY SLOOPY WITH THE ROOF TAR AND HIGH TEMP SILICONE

    • @mrEnergy511
      @mrEnergy511  3 роки тому +1

      The main goal with a roof flashing is NO LEAKS! Mission accomplished...

    • @blueplasma5589
      @blueplasma5589 2 роки тому

      he said "can't use too much"