DSC Power Series Programming - Alarm System Store Tech Video

Поділитися
Вставка
  • Опубліковано 7 січ 2020
  • Ryan Malanoski of Alarm System Store steps you through the basic programming of a DSC Power Series alarm system. Follow him as he guides you in setting zone information, delay times, and many more steps of the basic programming of this alarm panel. He also introduces you to our quick start guide which makes programming very simple compared to the manufacturer's manuals.
    Please comment in the comments section if you have any questions and be sure to slap that like button and subscribe to our channel for all of our how to videos for some of today's most popular DIY security systems.
    You can also visit our website at alarmsystemstore.com for all of our great deals on security equipment.
    You can also follow us on the following social sites for information, coupon codes, and much more!
    Facebook - / alarmsystemstore
    Twitter - / alarmstore
  • Навчання та стиль

КОМЕНТАРІ • 88

  • @Musicman-50
    @Musicman-50 2 роки тому +2

    This is so very helpful. Thank you for this excellent tutorial.

    • @andybowman9697
      @andybowman9697 2 роки тому

      You are most welcome. Glad you found it useful!

  • @eugenetswong
    @eugenetswong Рік тому +6

    NOTES
    03:22 Entering Programming Mode [*6], And Setting Time & Date [[24 hr format] hhmm mmddyy]
    04:36 Entering Installer Mode [default password: 5555]
    04:52 Entering Zone Data [001 & 002]
    05:54 Toggling Zones [202]
    06:21 Entering Partition Data [005]
    07:33 Entering Resistor Data [013]
    08:09 Setting Telephone Reliability [015]
    08:58 Quick Start Guide
    09:20 Setting Master Code [007]
    09:48 Getting Orange Triangle Data [*2]
    10:12 Conclusion

  • @abureehan486
    @abureehan486 4 роки тому +1

    Very very nice. THANKS

  • @pablowang2193
    @pablowang2193 Рік тому +1

    Thank you so much

  • @daphnacaplan53
    @daphnacaplan53 Рік тому

    Thanks for the info. I bought a new remote (same as I currently have) and need to code it to the alarm system which has already been programmed. Can't find instructions on how to do this.

  • @tonyjones7089
    @tonyjones7089 3 роки тому +2

    Adding a wireless contact, I inadvertently made my front door (Zone 1) to show it being open, when in fact the door is closed. How do I go back and correct this to show that the door is closed or open correctly? Thank you!

  • @roystervi
    @roystervi 3 роки тому +1

    any video on how to add zones to partitions?

  • @robertrutenberg3919
    @robertrutenberg3919 2 роки тому +1

    How do you program the keypad on a dsc so it doesn't beep when the ac power goes out?

  • @alexanderippolito5408
    @alexanderippolito5408 Рік тому

    Hello
    How do you adjust the brightness on the pk5501? It seems to not save my brightness level. Keypad is dark.

  • @shelliecoats1979
    @shelliecoats1979 3 роки тому

    We purchased a home with a media panel and this alarm system with motion detectors. I unplugged it because we had no information on how to set it up. It has been 9 months since we moved in and now I am ready to tackle this installation. HELP!!! I have no codes from the previous owner and I really am not sure where to begin, other than plug it back into the media outlet and I have the alarm box as shown above. I don't really even know what else to do. I would really appreciate any help. Thank you.

  • @jj-iv8ql
    @jj-iv8ql 3 роки тому

    Hi - can anyone advise how to set a DSC LCD 5511 stay mode to have a delay of 20 sec if activated - my alarm has been set to activate with no warning - people keep opening windows - and alarm activates straight away thanks

  • @shafirsf
    @shafirsf 4 роки тому

    Pls tell how to connect bentel bgsm 120B gsm module to DSC 1832

  • @alaaalabdali7133
    @alaaalabdali7133 3 роки тому

    Tack

  • @alanhill3968
    @alanhill3968 4 роки тому

    Help needed please. I cannot set my DSC alarm in stay mode, what setting do I need to look at TIA

    • @tr4ptamine
      @tr4ptamine 4 роки тому +2

      Press and hold the stay key (or the house with a person in it,for international keypads) and it should arm to stay

  • @sarytan1491
    @sarytan1491 2 роки тому +1

    How to programing 2 keypad difference funtions ??

  • @tupelowoodcarver1785
    @tupelowoodcarver1785 6 місяців тому

    My 5500 keypad displays low battery key 2. Cannot find key 1 in 804 any help finding key 1 and key 2 locations.
    Also moved this keypad from my old house to my new one. Used to display open zones but doesn’t now?

  • @johnhewetson4406
    @johnhewetson4406 3 роки тому

    Can anyone explain to me what (071) First User Display Mask and (072) Second User Display Mask do?

  • @umarb4523
    @umarb4523 4 роки тому

    When i try to go in enrollment mode 898 or 804 it just backs out and says enter section again... please help??

  • @aaronrynehart468
    @aaronrynehart468 3 роки тому

    Is there a way to stop the external strobe beeping when you turn the alarm on and off?

    • @andybowman9697
      @andybowman9697 3 роки тому

      Strobes dont normally beep so I assuem you are talking about a siren doing this. Yes, the option is called "bell squawk on arm / disarm" It is off by default though. This is in program section 014, opt 1.

  • @tupelowoodcarver1785
    @tupelowoodcarver1785 Рік тому

    Using pk5501 followed the quick start and video. Have 4 zones. 1 being front door (delay), 2 interior door (instant), 3 motion (set to 5), 4 interior (instant).
    My motion does not work. Thought it was a bad sensor and changed. Same result. Is there something I’m missing? What should the attributes on this be?

    • @AlarmSystemStore
      @AlarmSystemStore  Рік тому

      Generally you don't mess with attributes for a hardwired zone.

    • @tupelowoodcarver1785
      @tupelowoodcarver1785 Рік тому

      @@AlarmSystemStore any ideas why it does not operate? I checked, and I have 12v at the board, and terminals are nc/c
      How would I program/re program just the motion w/o erasing the system. Thanks btw

  • @davidfrankos5561
    @davidfrankos5561 Рік тому +1

    Would have been nice if he would have showed the whole keyboard so you could see what he was doing.

  • @jean-marckanzki3051
    @jean-marckanzki3051 6 місяців тому

    Good evening anyway i could contact you directly, to help me with a my homes systems?

  • @Yeahitsmeagain92
    @Yeahitsmeagain92 Рік тому

    My zone with the magnetic contact has the green check mark but doesn’t turn off when the contact is disconnected. Its not sending a signal when open. Any ideas?

  • @rogehrify
    @rogehrify 3 роки тому

    When I power up the system and connects the bell I get a low yelp alarm from it. When I measure the bell output I constantly have about 12 V from the output. If I trigger an alarm the siren works att full volume so the system seems to work, but I cant get rid of the low volume alert sound! Any ideas what to do?

    • @AlarmSystemStore
      @AlarmSystemStore  3 роки тому +1

      There is always supervisory voltage on the bell output. Generally the siren is not sensitive enough to sound from this. If it does though, you will need to add a resistor. I don't recall the value off hand but I'm thinking it's a 1k.

    • @rogehrify
      @rogehrify 3 роки тому

      @@AlarmSystemStore I used a resistor and now it is quiet :) Thank you for your videos, I would have been lost without them 👍👍

    • @rogehrify
      @rogehrify 3 роки тому +1

      @@AlarmSystemStore , I´m almost done installing my home security system :) The only thing that´s not working is the telephone dialler. I haven´t got any landline, only an old GSM dialler (Ericsson TS90) but I can´t get it to dial my phone when I trigger the alert. The display shows communication error and there are two cables on the gsm-dialler that´s not attached to the board... I havent got a clue where to attach them. Any ideas what to do? If I call the dialler from my cellphone I can see that the small light on the gsm-dialler changes, so it´s indicating that the sim-card connection works anyway..

  • @tyhillinc
    @tyhillinc Рік тому

    Question my dsc go off even night at 12:41 am with me sitting it someone told me it may be scheduled please help

  • @gidbosson-route786
    @gidbosson-route786 3 дні тому +1

    i cant find the quick start guide 😔😔

    • @AlarmSystemStore
      @AlarmSystemStore  2 дні тому

      www.alarmsystemstore.com/pages/programming-quickstart-guides

  • @MaggioRacinginc
    @MaggioRacinginc 3 роки тому

    I have a dsc wired motion sensor that I want to remove. Can I just jump zone 1 to com and remove the wires. I do not have the installer code.

    • @AlarmSystemStore
      @AlarmSystemStore  3 роки тому

      Yes that would work assuming your panel isn't using resistors. If it is however, you would need to use a 5.6k resistor to jumper it there.

  • @omotayosamuel49
    @omotayosamuel49 Рік тому

    my dsc is showing gen system temp, what does this mean?

  • @thekliable
    @thekliable Рік тому

    Hi! I changed my SIM Provider, removed the SIM PIN, yet I get the following troubleshoot message: Cellular Trbl, Alternate Communication. I have contacted the Phone Provider, and there is active signal on the SIM. Could anyone please help? thanks!

  • @youngfox12
    @youngfox12 2 роки тому +1

    I need to know what your profession is. I don't know how it is called in English. Thank you

  • @straighttothepoint364
    @straighttothepoint364 3 роки тому

    How do I reprogram after canceling our monitor service to stop sending signals to avoide the error code 4 ? The person keeps saying we need a service call or get monitoring again. Can I just disconnect the communication wire?

    • @AlarmSystemStore
      @AlarmSystemStore  3 роки тому

      Unplugging the phone cable will still generate the FTC / Comm error. Only way to resolve it will be to deprogram comms in the system. If you don't have the installer code though you will be unable to do so.

    • @straighttothepoint364
      @straighttothepoint364 3 роки тому

      @@AlarmSystemStore is there a way to find the installers code? The installer will not provide me with the number can I factory reset?

    • @AlarmSystemStore
      @AlarmSystemStore  3 роки тому

      @@straighttothepoint364 UA-cam "DSC factory reset". If it's had installer lock enabled though it will not reset the code and there is no way around it.

    • @straighttothepoint364
      @straighttothepoint364 3 роки тому

      @@AlarmSystemStore so that's how this guy scams another service call...ill leave it unpluged

  • @guesswhomartin9249
    @guesswhomartin9249 4 роки тому +2

    You video is great. Only you did a lot of unnecessary talking for the first 3:30 of this video. Once you started teaching it was great.

  • @pjsjourneys4968
    @pjsjourneys4968 2 роки тому

    I inadvertently made several Zones to show them being open, when in fact the doors/windows are closed. How do I go back and correct this to show that the doors/windows are closed or open correctly? Thank you!

  • @bobwalton4630
    @bobwalton4630 3 роки тому

    I have a DSC system with three keypads, three partitions and a RF repeater. All I have to do is delete a zone in trouble and learn a new one in. I tried all three keypads and my programmer and could not get into programming. I press *8 and it says, "INVLID ENTRY" before I even enter the installer code. I am going back tomorrow and I do not want to have to swap it out

    • @AlarmSystemStore
      @AlarmSystemStore  3 роки тому +1

      I could see getting that after your code is entered, but I've never seen it display that from simply hitting *8.

    • @bobwalton4630
      @bobwalton4630 3 роки тому +1

      I think it was because one of the partitions was armed

    • @AlarmSystemStore
      @AlarmSystemStore  3 роки тому

      @@bobwalton4630 Ahh yes that will do it too.

  • @ajithk.a5556
    @ajithk.a5556 3 роки тому

    sir , what is the code for PIR sensor with exit delay?

    • @AlarmSystemStore
      @AlarmSystemStore  3 роки тому

      All zone types will provide an exit delay, but if you want a motion to be stay and away capable as well as have an entry delay you would use an 06 type.

    • @ajithk.a5556
      @ajithk.a5556 3 роки тому

      @@AlarmSystemStore Thank You sir, and one more , How to label each zone to identify?

    • @AlarmSystemStore
      @AlarmSystemStore  3 роки тому +1

      @@ajithk.a5556 This is done in keypad programming, assuming that you have a full alpha model keypad. I don't believe we have a vid on it but I will add it to our list.

    • @ajithk.a5556
      @ajithk.a5556 3 роки тому

      @@AlarmSystemStore I don't have full alpha keyboard. I watched your neo keypad video, Is that zone labeling settings same as above green light keyboard?

    • @AlarmSystemStore
      @AlarmSystemStore  3 роки тому

      @@ajithk.a5556 If you don't have a full alpha pad you can't program zone labels.

  • @Yeahitsmeagain92
    @Yeahitsmeagain92 Рік тому

    My magnetic contact has the green check mark but doesn’t turn off when the contact is disconnected. Any ideas?

    • @AlarmSystemStore
      @AlarmSystemStore  Рік тому

      Too many possibilities to really explain each here but.. programming, wiring, contact itself, zone def used. You really just need to explore each. If you have multiple contacts on one zone, perhaps you've wired them in parallel rather than series.

    • @Yeahitsmeagain92
      @Yeahitsmeagain92 Рік тому

      @@AlarmSystemStore ive checked the wiring and the contact itself. Any ideas on zone definitions? What zone definition is for a magnetic contact that stays on?

    • @AlarmSystemStore
      @AlarmSystemStore  Рік тому

      @@Yeahitsmeagain92 Any zone def that has force arm on such as the stay / away types will always show green like that.

  • @yungkalimusic
    @yungkalimusic 3 роки тому

    Skip to 4:50

  • @djrobinsa
    @djrobinsa 2 роки тому

    You missed the easy way .... FLOW Chart programming of the panel ... no manual required ..... it flows to each section like the manual reads but o the LCD keypad .... POWER series PK5500 lcd brought it out first but never advertised the feature ...

  • @mukeshkumarsingh3265
    @mukeshkumarsingh3265 4 роки тому +2

    Dear sir can you provide PDF file for programing

    • @mukeshkumarsingh3265
      @mukeshkumarsingh3265 4 роки тому +1

      keypaid error showing 1 2 3 4 5 6 7 8 and please suggest how to resolve it

    • @mukeshkumarsingh3265
      @mukeshkumarsingh3265 4 роки тому

      Please reply

    • @AlarmSystemStore
      @AlarmSystemStore  3 роки тому

      @@mukeshkumarsingh3265 Programming guides www.alarmsystemstore.com/pages/dsc-power-series-pc1616-pc1832-pc1864-quickstart

  • @anthonyhinskon2835
    @anthonyhinskon2835 4 роки тому

    How to program dress code

    • @andybowman9697
      @andybowman9697 3 роки тому

      There is no dress code for programming. Wear whatever you wish when programming, LOL.
      The duress code is programmed in *5 menu just like a user code. Just make it a duress by enabling attribute 2 in the user code section. We have a video about user codes in our play list BTW. Not sure it specifically addresses duress codes but like I said a duress is a user code with option 2 enabled so it's pretty much done the same.

  • @moviesword8801
    @moviesword8801 3 роки тому

    How to remove partitions selection? Even I did hardware reset and system reset it always appear, it's hassle you need to choose from partitions 1 to 4

    • @AlarmSystemStore
      @AlarmSystemStore  3 роки тому

      There are several steps to partitioning a system, most of the programming step in the panel. There is one however in the keypad programming and that is why resetting the system didn't resolve it. From this particular keypad you need to go into keypad programming 000. Going off memory but I believe you hit 0 again to get to partition and slot which is where you change the partition that this pad is assigned to.

  • @miguelburke5825
    @miguelburke5825 3 роки тому

    Phone line

  • @sum1337
    @sum1337 3 роки тому

    most dsc are ''blind'' where am from what a horrible thing xD

  • @koulisnoulis
    @koulisnoulis 3 місяці тому

    Καλησπέρα πος μπορο ΝΑΤΟ βαλο να χτυπάει στο κινητο

  • @newkeds
    @newkeds 4 роки тому +2

    I'd rather have my home burglarized.

  • @markhughes3383
    @markhughes3383 4 роки тому +1

    What an awkward dated system

    • @andybowman9697
      @andybowman9697 4 роки тому +4

      Not nearly as much as Honeywell. The Vista is technically an antique I believe.

    • @1990notch
      @1990notch 4 роки тому

      @@andybowman9697 the vista is very reliable though.

    • @sum1337
      @sum1337 3 роки тому

      @@1990notch and you plug in your programming keyboard and boom done while most dsc are ''blind'' horrible to program

  • @rwnljn
    @rwnljn 2 роки тому

    Horrible place to buy a product. The support folks lie about products being a direct replacement. I bought 4 Smoke Detectors that were not NOT a direct replacement. Lost money and buyer beware!

    • @AlarmSystemStore
      @AlarmSystemStore  2 роки тому

      Rick, the 4WB series is indeed the replacement for the old 2412 series. Call System Sensor yourself and ask, we're not lying. No one here is commissioned or incentivized to do that anyway... check yourself www.systemsensor.com
      Nonetheless, submit an RMA here and we'll refund you. We are an honest company.
      www.alarmsystemstore.com/pages/return-authorization-form-rma

  • @michaellair6691
    @michaellair6691 Рік тому

    What a horrible description on what zone type to use for motions. It should be a zone type 4 Interior follower. If you program as 5 and your walk across your living room to turn off your alarm by the front door the alarm trips because you walked in front of the motion that has been programed as an instant. The interior follower knows you've open an entry exit zone and will give you time to disarm BUT if you come through a living room window and walk in front of the motion it goes of instantly because you did not open an entry exit zone, and yes they will also shut off when armed as stay.

    • @AlarmSystemStore
      @AlarmSystemStore  Рік тому +1

      Might wanna brush up on your DSC zone definitions. From the manual:
      [05] Interior Stay/Away: Similar to ‘Interior’ except that panel will auto-bypass the zone if Armed in the Stay mode
      05 is in fact an interior. The only differnce is it allows you to automatically bypass in stay mode in case you want to arm at night and walk around without tripping the motions. 04 is generally only used in commercial where that is not needed.