How To Test Your Gas Valve

Поділитися
Вставка
  • Опубліковано 26 лис 2024

КОМЕНТАРІ • 33

  • @NoneFB
    @NoneFB Рік тому +4

    You have a big future in trouble shooting these gas valves! Part 2 is the pressurized air into the manifold and part 3 is the voltage signals going into the valve. You are a very smart technician! Keep up this good work!

  • @alonzogreen1527
    @alonzogreen1527 11 місяців тому +2

    You explained well, great job.

  • @yougoog1
    @yougoog1 Рік тому +1

    Thank you for your great video teaching how to troubleshoot the gas valve. My gas company just installed the new gas meter at my house. I turned on the gas furnace, but it was not working. I saw the hot surface ignitor glowed, and I heard the relay click sound from the gas valve, but I did not see any flame, and did not hear any hissing sound of the gas flow from the manifold. Now I am not sure if the failure is due to the fact that there is no gas fed to the inlet of the gas valve, or due to a bad gas valve. I would like to check the gas supply first. Could you please advise what would be a proper and easy way to check if the gas is present at the inlet of the gas valve? I know the best way is to use a manometer to measure the gas pressure at the inlet port, but unfortunately I do not have one right now. I ordered one and should arrive in a week or so, but if there is a easy way without using a manometer, I would like to try it now. Thank you!

    • @opentopublichvacschool
      @opentopublichvacschool  Рік тому +1

      So, I'm not a plumber so I wouldn't be able to talk about the nuances of wc pressure (gas pressure) but I can say, if you hear the click from the solenoid on the gas valve but it isn't lighting it could be power related, (board isn't sending constant 24v) or gas pressure issues, or bad gas valve.
      Other things to note, there could be a clog in your burner plates on the burner trail, or the brass orifices coming off of the manifold could also be clogged.

  • @fengtaowang5348
    @fengtaowang5348 Рік тому +2

    Very informative video. One question about the voltage test: I saw a reading of 14 VAC before the board sends 24 vac to the gas valve. Is the reading supposed to be zero, other than 14 vac? On my own Bryant gas furnace, I noticed the same 14 Vac reading.

    • @opentopublichvacschool
      @opentopublichvacschool  Рік тому +1

      It can really depend on the type of gas valve and unit you have. I've seen units that send a sort of 'test' voltage to make sure the ignitor is coming on like it should (I think Trane and some carrier have a smart sense ignitor) and some boards that also send a blip to see if the gas valve is there. Basically not enough to turn it on. Usually, however, I see this on smart valves which manufacturer's stopped using because of all the issues they kept having.

  • @robertstonebreaker8394
    @robertstonebreaker8394 Рік тому +1

    Good straight forward info thank you .

  • @DanielSon-v4q
    @DanielSon-v4q 2 місяці тому +1

    Thanks that was really helpful

  • @icarus6942
    @icarus6942 Рік тому +1

    Question. What about gas valves stuck open and leaking? Thanks for the great video! 👍

    • @opentopublichvacschool
      @opentopublichvacschool  Рік тому

      Sorry for the super late response, I'm sure you've found the answer by now but just in case I can give some insight. When the solenoid on the gas valve is stuck open, there's one of two things happening here: Either the gas valve is receiving signal from the control board to come on, or the solenoid is bad. An easy test for that is to remove the two wires from your gas valve, connect your leads to each one and then turn on the unit. (always make sure the door switch is taped in before calling for heat.) Just as your ignitor starts to come on, you should get your 26-28 volts ac until the unit will fault out for no flame sensed. If the valve is at fault and staying stuck open, that is a new gas valve. As far as leaking, if you are concerned about that (which uh, yeah you should be), turn your shut-off valve on your gas line by the unit to off. That's common sense, but figured I'd add that in for good measure.

  • @johnnybquick2849
    @johnnybquick2849 Рік тому

    Tthank you very much. Very informative and helped me so much.

  • @MrSanbonsakura
    @MrSanbonsakura 11 місяців тому

    You have to check resistance on contact and make sure that it's not reading OL before you taking your valve out.

  • @biglon74
    @biglon74 Рік тому +2

    I had a spider build a web inside one of the tubes and it messed up the whole gas flow. Once the metal orifice were removed I could see the issue

    • @opentopublichvacschool
      @opentopublichvacschool  Рік тому

      Wow, that is crazy! I've seen some strange things before but I think that one probably takes the cake. Glad you were able to fix it at least.

  • @AlbertaAudit
    @AlbertaAudit 10 місяців тому

    I have a Rheem criterion 2 furnace. It’s started to only blow warm air, not hot like usual. What could be causing this?
    It starts up like normal, seems to run normally, but only puts out warm air.
    I’ve tried by passing the high limit switch and thermostat. Same result.

    • @Pseudify
      @Pseudify 8 місяців тому

      Sorry if this sounds too obvious, but when I’ve had this problem it was a dirty air filter.

  • @terrywaresr
    @terrywaresr Рік тому

    How do you clean a furnace burner when the cover is sealed shut

  • @bimcoachbim4852
    @bimcoachbim4852 10 місяців тому

    Good job. I like your video.

  • @rhondawestaway626
    @rhondawestaway626 10 місяців тому

    Nobody knows what is wrong with my furnace. It runs great but when it gets warm in the afternoon and doesn't run for a couple hours it won't restart until I do a hard reset. Then it works perfectly all night long. I've had multiple people out here. One guy wanted to replace the valve but it runs perfectly after hard reset all night. It's a newer furnace. Coleman DGAX090BDTA. It hasn't been cleaned for awhile. My dad did it but he passed and I just didn't get it done. The filter is a month old and is a 3 month filter. The code is 1 red flashing. Please help me.
    Thank you.

  • @jandeband
    @jandeband 2 місяці тому

    Thank you, energize valve and blow thru, great ❤

  • @dudleydorite7678
    @dudleydorite7678 9 днів тому

    Can you speed it up? I'm freezing

  • @qzorn4440
    @qzorn4440 Рік тому +1

    very nice video. thanks.

  • @JJsSwage
    @JJsSwage 8 місяців тому

    Wheres the drip leg

    • @opentopublichvacschool
      @opentopublichvacschool  7 місяців тому

      The drip leg on this old unit is actually to the left of the unit out of view. 😂

  • @goodeyes2c
    @goodeyes2c Рік тому +4

    I did this test on a water heater using a lighter and there was gas going through cuz im still growing my eyelashes and brows 😊

    • @opentopublichvacschool
      @opentopublichvacschool  Рік тому

      Well, on the bright side you're still here─ so there's that. Glad you're still in one piece!

  • @kingtut5923
    @kingtut5923 Рік тому +2

    Can't understand a thing you say

    • @Seabass1206
      @Seabass1206 11 місяців тому +2

      get your ears checked

  • @jeffreystevens3077
    @jeffreystevens3077 11 місяців тому +1

    Or folks. You could just have an HVAC technician come out with the proper tools such as a manometer to verify that the gas valve has the proper gas pressure as well as allowing gas to flow through the valve without taking it apart.

    • @opentopublichvacschool
      @opentopublichvacschool  10 місяців тому +3

      Both methods achieve the same result. One requires special tools, one does not. One you can do without spending money, one you can't. If you're upset that people don't need your service, you should make yourself more indispensable.

    • @lockedo9908
      @lockedo9908 Місяць тому

      Gotta get paid somehow, huh, Chuck?

  • @tomasramirez1984
    @tomasramirez1984 Рік тому

    Hi baby I like how to tech. ❤