How To Test Limit Switches

Поділитися
Вставка
  • Опубліковано 26 сер 2024
  • Need to know where your limit switches are for your furnace and what they do? Find out what to do if you have already purchased the part and it's still having the same issue! Need help? We've got you covered!
    *Do NOT use a lighter to test parts if you are worried you will hurt yourself. Better safe than sorry! Use a heat gun!*

КОМЕНТАРІ • 38

  • @JohnnieDeLaCruz
    @JohnnieDeLaCruz Рік тому +3

    Great description and details. I work gas service for a utility company and often go out to many homes helping customers keep gas flowing for heat and just advised a customer on this part. In my down time I watch videos to keep my troubleshooting skills up . Looking forward to seeing other videos here
    Thanks

  • @copperkeyracing6167
    @copperkeyracing6167 5 місяців тому

    I love her word usage, funzies, booties, EZ, smouge. Super cute!

  • @joes3662
    @joes3662 Рік тому +4

    This information saves lives :D. Great tips!! looking forward to the coil video

  • @josh3386
    @josh3386 Рік тому +3

    Thank you for making this! I’m a newer tech and keep getting frustrated and confused what limit is tripping on calls, they all are closed but the control board keeps saying a limit switch is open after it runs for a bit. I was always told if there’s continuity then they’re good. Need to start bypass then one by one to see which one is tripping when it should not be!

    • @opentopublichvacschool
      @opentopublichvacschool  Рік тому +3

      My youtube isn't telling me when I have responses! So sorry for the late reply. Yes, even if it has continuity it can be bad, however, at times it can also mean the high limit is doing it's job and it's just low air flow. Companies like Carrier, or Lennox (although Lennox I've seen can make their manuals more detailed) only say LS on the wiring diagram. It's like...OK, which limit switch? At that point, it is so flipping tedious to have to trace back which one is actually the problem based off of the wiring chart, or just bypassing each one. I swear engineers don't have technicians in mind when they design units.

  • @jeffpriode7514
    @jeffpriode7514 3 місяці тому

    Liked video on how to check limit switch circuit

  • @eddieochoa6636
    @eddieochoa6636 21 годину тому

    Great video

  • @michaelhernandez439
    @michaelhernandez439 Рік тому +2

    You're explaining tech in shirt sleeve English.
    Beyond cool !
    Thank you !

  • @jacobcrosby275
    @jacobcrosby275 7 місяців тому +1

    This was awesome

  • @user-dq8wg8kn4o
    @user-dq8wg8kn4o 3 місяці тому

    What's the restriction on gas presure ? I thank you for your response 👌🙏🙌🫴🫵🫶
    Nice video 👌🫵🫶🌻🌷🌸🌹💐🥀

  • @PuerinTheHunter
    @PuerinTheHunter 6 місяців тому

    Excellent instruction! thanks!

  • @JCarlWilson
    @JCarlWilson Рік тому +2

    Good information, thanks

  • @_mikishi_
    @_mikishi_ Рік тому +2

    Thanks for the video

  • @christianolsen1256
    @christianolsen1256 5 місяців тому

    Thanks!

  • @sambathbunkh
    @sambathbunkh 7 місяців тому

    Great topic nice to see you

  • @user-dq8wg8kn4o
    @user-dq8wg8kn4o 3 місяці тому

    Hi again , What's the sign of over heating please👌🙏🙌

  • @jacobbishop686
    @jacobbishop686 9 місяців тому +1

    Thankz,,,sweety,,got my unit,,,😀😀😀😀😀

  • @explanoit
    @explanoit Рік тому +1

    Thank you for video

  • @derekdaling5236
    @derekdaling5236 Рік тому

    Very informative. I have my inducer randomly starting up during AC season. I’ve jumped all the limit switches and it still happens. I’ve replaced the main board and it still happens. What the heck is telling my inducer to start up? Happens when I only have R and Y jumped too eliminating the t stat. Inducer never ran before during the summer.

    • @opentopublichvacschool
      @opentopublichvacschool  Рік тому

      Does it behave the same way in heating? Usually when you are bypassing limit switches, you need to bypass them on the control board itself. The control board should be flashing a code if it ever causes a failure. Normally when this occurs, it is from an open limit switch. How are you bypassing the limit switches? You mention it ONLY happens when you jump R to Y. So this does not occur when you jump R to G or R to W?

  • @jeannogueira5859
    @jeannogueira5859 8 місяців тому

    Very nice, thank you.
    My furnace shut off during the cycle, but we lost 24v to the thermostat, then 10 sec. The power to the thermostat is back. Why?

    • @opentopublichvacschool
      @opentopublichvacschool  8 місяців тому

      There shouldn't be much in like that can intermittently break voltage to the thermostat. The most common culprit would be a bad wire nut, slightly broken wire, or overflow shut-off switch. You'll do best to actually check for the 24V at the furnace when it fails on the thermostat.

  • @jamesbuddy3485
    @jamesbuddy3485 Рік тому +1

    good info thanks i have the GHR26Q3-75-2 lennox limit light came on so i had and changed hi limit and roll ran for a day same thing happened roll not tripped check a-coils very clean new filter i have a broad on the way ? any thing other to check thanks james

    • @opentopublichvacschool
      @opentopublichvacschool  Рік тому

      Hi James! Sorry for the delayed response so if you have figured it out awesome! If not, we can look at a few ideas. When you say the limit light came on, what did your fault codes say exactly? Did it say 'High limit or Auxilary limit switch open?' Does it just say limit switch open? Does it stay on for a while and then shut off, or is it faulting immediately? Thanks!

  • @miketrissel5494
    @miketrissel5494 7 місяців тому

    Nice presentation. You probably didn't know it, but there was some kind of creepy and distant music that was fading in and out in the background that was very distracting. You might want to re-record this.

  • @wayne7speaks
    @wayne7speaks 6 місяців тому

    where can we get the jumper

  • @mikeadler434
    @mikeadler434 Рік тому +1

    👍👍

  • @copperkeyracing6167
    @copperkeyracing6167 5 місяців тому

    8:17 "You buy a double male for funzies, and then it's super EZ, but sometimes they don't work with big booties." Wow! Seriously!?!?!

  • @hankus253
    @hankus253 Рік тому

    Safer than using FIRE would be to use a heat gun. They are more than capable of generating safe high heat.

    • @opentopublichvacschool
      @opentopublichvacschool  Рік тому +1

      Of course! Safety first. This was before I got my heat gun. 100% should always not play with fire.

    • @vladkantor6156
      @vladkantor6156 Рік тому

      What , if no coil exists. Just heater?

  • @copperkeyracing6167
    @copperkeyracing6167 5 місяців тому

    5:17 "Some of them are 7 inches. I've even seen some that are 11 inches... good man has those"... wow, 11 inches!!! That's a good man, indeed! I'm the 7-inch type.

  • @jamesbuddy3485
    @jamesbuddy3485 Рік тому +1

    looks like it was my broad