Bathroom fan roof vent kit install - Broan RVK1A vent

Поділитися
Вставка
  • Опубліковано 19 чер 2021
  • Bathroom ceiling fan roof damper vent installation. Installing a Broan RVK1A roof vent to eliminate the moisture going into the attic coming from the bathroom ceiling fan. It is important to keep moisture out of the attic not dump it into it. Moisture in your attic can lead to mold mildew and rotting out your roof decking.
    Consider subscribing to the Grand Roofing UA-cam channel and hit the Bell notification so you don't miss the next video.
    Amazon affiliate links
    This post includes affiliate links for which I may make a small commission at no extra cost to you should you make a purchase.
    Broan RVK1A Roof Vent Kit
    amzn.to/2UfI9uF
    Yvan Telescoping Ladder,12.5 FT One Button Retraction Aluminum Telescopic Extension Extendable Ladder, Slow Down Design Multi-Purpose Step Ladder
    amzn.to/3pnNpY9
  • Навчання та стиль

КОМЕНТАРІ • 72

  • @pastortroy4life
    @pastortroy4life Місяць тому +4

    My guy, you would benefit from watching a few this old house episodes

  • @scottferrell4462
    @scottferrell4462 3 роки тому +1

    Great job. Keep em coming. This is the 2nd video this month that has helped me do my job better.

  • @M3XIC4NM4N
    @M3XIC4NM4N 3 роки тому +3

    Perfect timing!! Im going to be doing this in my house in the next week or two. Great video sir, thank you much!!

  • @Jupiter742
    @Jupiter742 3 роки тому +7

    Great video. I usually use a hole saw to make the opening, but that works too.

  • @MaMa-qh4dy
    @MaMa-qh4dy 3 роки тому +5

    Nice work. You always make it look sooooo easy!

  • @Sextonius
    @Sextonius Рік тому +1

    This video is incredible. Man you are efficient. Thanks so much!

  • @jafo68
    @jafo68 2 роки тому +1

    Great video. Thanks for the step by step install.

  • @Blacktop.Outdoors
    @Blacktop.Outdoors 3 роки тому +1

    Awesome video man I really enjoyed it thanks for the tips man

  • @gklug305
    @gklug305 2 роки тому +1

    Never seen a hammer like that. Awesome tool!

  • @alexmusson4379
    @alexmusson4379 Рік тому

    New subscriber, really enjoy your detailed videos. Keep it up!

  • @ronaldnayman4841
    @ronaldnayman4841 10 місяців тому +1

    Thanks, great video.

  • @OldScuulAndy
    @OldScuulAndy 6 місяців тому

    Thanks for uploading

  • @manueldasilva9025
    @manueldasilva9025 6 місяців тому

    Good job

  • @johnwaby4321
    @johnwaby4321 3 роки тому +1

    Brilliant job 👍👍. I have one of those ladders absolutely brilliant 👍

    • @GrandRoofingInc
      @GrandRoofingInc  3 роки тому

      I love that ladder it is my go-to ladder! I use it everyday. I would note try not to get it muddy because it makes it harder to retract and extend.

    • @davidlindgren7605
      @davidlindgren7605 2 роки тому

      @@GrandRoofingInc what's the brand of that ladder, and where can I buy one?

  • @josephedgar3033
    @josephedgar3033 Рік тому +1

    You have def done roofing before, I have a dryer vent business and shingles still give me a run for my money

  • @brucego6018
    @brucego6018 3 роки тому +1

    Awesome vent install. I need to do mine here soon n your video help. TY. HOWEVER You should have cut duct in half then put it on. Is too long.

  • @ianwilson1986
    @ianwilson1986 3 роки тому +20

    Good job .. I would have used the insulated flex and never use duct tape on any duct the adhesive will dry out and fail

    • @akbychoice
      @akbychoice 2 роки тому +2

      Aluminum tape with bitumen works great.

    • @dallinostler4794
      @dallinostler4794 Рік тому

      Lol why would you worry about insulating exhaust vent? Hahahahahaha 😂

    • @rogermurphy1548
      @rogermurphy1548 Рік тому +2

      I agree, always use insulated flex so that you eliminate all the problems that he was talking about with condensation on the duct work inside the attic.

    • @user-ii5sk1sp4f
      @user-ii5sk1sp4f Місяць тому

      @@dallinostler4794 To reduce condensation

  • @DirectorWD40
    @DirectorWD40 2 роки тому

    Thanks!
    What are the differences between this flat kind and the curved shaped type?

  • @wishIcouldplayguitar
    @wishIcouldplayguitar 2 роки тому +2

    Have you had any issues with your collapsable ladder? I was eager to buy one after seeing this video but there were several people who posted on Amazon that their ladders had collapsed on them due to the plastic rings breaking and they fell to the ground or got stuck on their roofs.

  • @juanquirino5544
    @juanquirino5544 3 роки тому +1

    I do have a question how do you come up with an estimate? Can you make a video on that ? How much you charge to shingle, take garbage, etccc ??

  • @daniellopez-fn4xe
    @daniellopez-fn4xe 3 роки тому

    I'm a roofer I be seeing roofs put the shingles flush with there gutter apron what do you think about that

  • @michaelthomas5133
    @michaelthomas5133 Рік тому +1

    I have a vent like that already installed in my roof. What is the adapter that twists into the vent called. Mine dosen't have one of those and I'm looking to vent an exhaust to it. Thanks

  • @midnighted
    @midnighted Рік тому

    What size nails do you typically use? 1 inch or 1-1/4inch?

  • @J3f33
    @J3f33 11 місяців тому +1

    What do you recommend to use for dryer vent ?

  • @weiss27md
    @weiss27md 2 місяці тому

    When do you think that the duct on an exhaust fan would need to be insulated?

  • @charlieholvey6336
    @charlieholvey6336 2 роки тому +4

    Hole saws usually make better cuts...just saying.

  • @ozzstars_cars
    @ozzstars_cars 5 місяців тому +2

    Woot woot, too close to that vent pipe. That's a no no.

  • @mrfixit391
    @mrfixit391 Рік тому

    What type of sealer is that you are using?

  • @chrishemingway4491
    @chrishemingway4491 Рік тому

    What happened to six inch steps that’s but with them vent I always have a full shingle under the vent then the sides don’t matter but the around the top you want a full shingle I leave I don’t put nails in the exposed area either but that’s what that foam double stick foam thing in the kit is for I would t use that either though I’m old school and like to do it my way because then I k ow I won’t get a call back hood work though keep it up I ordered on for my metal roof and I also ordered a pipe boot for my flu pipe and a cut pipe boot for my chimney stack and a boot for my shit stack with an extension kit and acouple mushroom tops then I’m venting my gables because I’m going over my old roof it’s a double wide mobile home

  • @dtm8073
    @dtm8073 Рік тому

    Absolutely love your videos but this vent is absolute garbage if you live where there's snow. It creates so much ice on your roof because the air coming out doesn't have a chance to properly evacuate so it creates condensation and melts the snow on the roof nearby the exhaust. You'd be surprised of how big an area it melts. I ended using longer pipe and going to gable end since I have a bungalow. Your explanation was bang on and perfect. How long ago were those shingles installed because you had no problems getting under them. When I installed that vent, my shingles (Owens Corning Duration) were 5 years old and I had a bitch of a time to get under them and I did it in the summer. In the spring I want to go and take that vent out since I'm now going thru gable end and I hate the thought of it.

  • @rottdogsparky
    @rottdogsparky 3 роки тому

    Flex line? Not rigid?

  • @DirectorWD40
    @DirectorWD40 2 роки тому

    Oh, btw... what are you thoughts about these?

  • @tng2432
    @tng2432 2 роки тому +1

    Trying to figure out how to do mine. Just wondering, is there any downside of drilling a pilot hole from inside the attic where I know what to avoid? I can't guess the location like you did from feeling for the softness of the roof.

    • @GrandRoofingInc
      @GrandRoofingInc  2 роки тому +1

      Absolutely not a problem to drill a pilot from the inside. I try to avoid hafting to go in the attic if I don't need to.

    • @GrandRoofingInc
      @GrandRoofingInc  2 роки тому +2

      I will say just be cautious if you're near a Valley dormer etc that you're not going to drill a pilot into a voided area you can't access from the roof.

    • @chrisyaritz2180
      @chrisyaritz2180 Рік тому

      Nice job....2 questions.
      which brand ladder are you using?
      some of the cheaper ones don't last.
      also Broans literature says that kit comes with a 4in to 3 in adapter....
      what are they referring to(the adapter that goes on the vent)?

  • @percyfaith11
    @percyfaith11 2 роки тому +11

    Duct tape is useless in the attic unless you want it to fail in less than a year. Better practice is to attach rigid ducting to that metal collar from inside the attic. Connect with sheet metal screws and seal with mastic and tape. If you can run rigid all the way to the fan that's the best. Also, if you don't seal the joint where the metal vent pipe twists into the fan hood moisture will leak out and get between the vent hood flanges and the roof and will wet the plywood. This will cause rot and mold.

    • @clownchkn
      @clownchkn Рік тому +1

      Thanks for writing this. yeah 11 months after reply, but I just watched this video. I believe this kit comes with a foam sealer for that joint. Also, from reading, that metal tape is the proper tape to use as regular duct tape rots and falls apart?

    • @percyfaith11
      @percyfaith11 Рік тому +1

      @@clownchkn Yes, in the heat of the attic the glue on the tape dries up and turns to powder and the tape starts to leak. Good quality aluminum tape meant for sealing ducts is what is needed. A pail of mastic and a disposable paint brush will be cheaper for doing long seams. They both have their place.

    • @clownchkn
      @clownchkn Рік тому

      @@percyfaith11 Thanks for the info! Never even thought of using mastic. UA-cam is such a great place for getting useful info!

  • @OldScuulAndy
    @OldScuulAndy 6 місяців тому

    You’re like the victory style but for roofing.

  • @DavidHKim-th4zc
    @DavidHKim-th4zc Рік тому

    what is the name / manufacturer of the ladder?

  • @EASYRIDERTOO
    @EASYRIDERTOO 2 роки тому

    You dont have to loosen the big area of shingle.

  • @A7ENB
    @A7ENB 3 роки тому

    anyone else notice the shingle overlay? Looks like 2-3" and staggard instead of running a step ?

    • @GrandRoofingInc
      @GrandRoofingInc  3 роки тому

      No clue who installed this but yes it did not have enough offset.

  • @akbychoice
    @akbychoice 2 роки тому +1

    A builder installed pvc pipe but ran it down to an elbow, turned 90° and ran it 18’. It filled with moisture at the elbow. It froze and built up till it cracked the pvc. Some inspectors either do t know what they are doing and shouldn’t or they get paid off. Lots of shoddy work in construction.

    • @MAGAMAN
      @MAGAMAN 2 роки тому

      New construction is essentially garbage

  • @paulallen5667
    @paulallen5667 2 роки тому +1

    I use a wire coat hanger in my drill and drill up and thru the shingles and leave the hanger poking thru then go up on the roof and find my hanger and cut my hole 🕳

  • @tommiller6580
    @tommiller6580 2 роки тому +1

    Doesnt look like the shingles overlap too much, seems like an 1 inch at the most, NO GOOD! Should be 3 -4 inches.

  • @TheYzeman
    @TheYzeman 3 роки тому +1

    How difficult is it with 2 layers of shingles? I bought 2 vents I need to add to the roof but I'm hesitant now and thinking about just hiring someone. I have done it before a long time ago.

    • @GrandRoofingInc
      @GrandRoofingInc  3 роки тому +2

      You do it the same way you would with one layer. You only tuck it under the first layer. The only difference is you need to cut through the second layer to cut the deck and to get the pipe through. Cut the second layer before you cut the decking or it will give up your blade.

    • @TheYzeman
      @TheYzeman 3 роки тому +1

      @@GrandRoofingInc Ah ok. That makes sense. I thought the vent had to sit under both layers. That would be a major pain. Thanks for your help!

  • @ThatReviewGuy69
    @ThatReviewGuy69 Рік тому

    Why not seal the vent channels so they aren't ever an issue? Just load em up full of caulk or roofing cement imo

  • @usaforever99
    @usaforever99 Рік тому +1

    I think the hole you cut on the roof is too big.

  • @MrShockman10
    @MrShockman10 Рік тому

    Just to ask this??? That looks like a three inch vent pipe. So If i were doing this install I would use a three inch hole saw instead of you using a reciprocating saw. You get a lot better looking opening. Here I thought you always want to do a good job???? Here in cutting this opening you failed!!!

  • @matt-xo2vr
    @matt-xo2vr Рік тому

    isn't water going to get in that vent?

    • @charlesrodriguez7984
      @charlesrodriguez7984 3 місяці тому

      No. It should be fine. Any drops that do blow in during wind driven precipitation will dry out when the fan turns on. I’ve seen if it’s really bad roofers will install a flashing in front of the vent to redirect the rain.

  • @elyarsamadi
    @elyarsamadi 8 днів тому

    I liked your video and I'm going to use all of your tips but removing all of those nails and work it from outside to make it only easier and not better, no reason to take those nails out and then hammer tons of nails down, that is compromising the integrity of the roof for sure, 2 minutes being in the dark hot attic (take a portable light with you!) worth it not to take all of those nails of and nail more back in and glue and patch, not a great idea at all.

  • @jeffhallam7990
    @jeffhallam7990 Рік тому

    not so sure code allows that vent to be that close to a stink pipe!

    • @charlesrodriguez7984
      @charlesrodriguez7984 11 місяців тому

      It does. Shouldn’t be a problem. I’ve seen it in my area. New homes with plumbing vents near bathroom vents.

  • @rumenocity1
    @rumenocity1 7 місяців тому

    Duct tape?????

  • @charleymitchell8904
    @charleymitchell8904 10 місяців тому

    That roof has inadequate ventilation

  • @ncooty
    @ncooty Рік тому

    @3:45: Wow, looks like the same person who did their HVAC also did their electrical. Good grief; shameful.

  • @Resist_JWO_1984
    @Resist_JWO_1984 3 місяці тому

    What a horrible cutting!!! 🤮👎

  • @LG-yy2up
    @LG-yy2up 9 місяців тому

    Good video but;
    You need an insulated duct for bathroom vent via attic, the one you used will accumulate moisture with time and clog airflow. Any duct via attic needs to be insulated, be it bathroom or dryer.