Inverter Refrigerator Dc Compressor UVW Testing In 3 Steps

Поділитися
Вставка
  • Опубліковано 13 бер 2022
  • In this video, I have shown you how to test an Inverter refrigerator dc compressor UVW with a multimeter with overload wires in simple steps. What should be the correct values on the multimeter and its body test? The compressor test we did is of a Samsung inverter refrigerator.
    ******************************************************************************
    Products You Might Be Interested to Buy
    Multimeters
    NEOTECK Digital Multimeter ➡️ s.click.aliexpress.com/e/_Dml...
    ANENG Q1 Digital Multimeter ➡️ s.click.aliexpress.com/e/_DeU...
    Digital Pen Multimeter ➡️s.click.aliexpress.com/e/_DkM...
    Rechargeable Smart Multimeter ➡️s.click.aliexpress.com/e/_DDm...
    UNI-T UT181A True RMS Auto Range Multimeter ➡️ s.click.aliexpress.com/e/_DFL...
    ANENG 616 Large Screen Digital Multimeter ➡️ s.click.aliexpress.com/e/_Dln...
    TOOLTOP ET8135 True RMS Multimeter ➡️s.click.aliexpress.com/e/_DB8...
    MASTECH MS8910 Digital Multimeter ➡️ s.click.aliexpress.com/e/_Ded...
    ZOYI ZT-X Digital Multimeter ➡️ s.click.aliexpress.com/e/_Dd9...
    ANENG Q1 Digital Multimeter 9999 Analog Tester ➡️ s.click.aliexpress.com/e/_DEz...
    Thermal Camera
    UNI-T UTI260B HD 256X192 Thermal Camera ➡️ s.click.aliexpress.com/e/_Deo...
    TOOLTOP ET692Cl Thermal Imaging Camera ➡️ s.click.aliexpress.com/e/_Dm0...
    Mileseey TR120E Infrared Thermal Imager ➡️ s.click.aliexpress.com/e/_Dej...
    Fluke TiS55+ Thermal Camera 9HZ ➡️ s.click.aliexpress.com/e/_DCO...
    Noyafa NF 522 523 Handheld Infrared Thermal ➡️ s.click.aliexpress.com/e/_DCe...
    TOOLTOP T7 256*192 Android Thermal Imager ➡️ s.click.aliexpress.com/e/_DmB...
    Soldering Wires
    10Pcs 2mm XZZ-2015 Desoldering ➡️ s.click.aliexpress.com/e/_Dkg...
    0.8mm/1.0mm 50g Lead Free Solder➡️ s.click.aliexpress.com/e/_DDn...
    0.6/0.8mm 50g/100g Lead Free Solder➡️ s.click.aliexpress.com/e/_DDC...
    200g 500g Tin Wire Soldering Wire ➡️ s.click.aliexpress.com/e/_DdQ...
    8g 50g Per Roll High Purity Soldering Wire➡️ s.click.aliexpress.com/e/_DCm...
    250m/roll 30AWG UL1423 Insulation Cable Copper➡️ s.click.aliexpress.com/e/_Deu...
    Vacuum Pump
    18V Lithium Battery Vacuum Pump ➡️ s.click.aliexpress.com/e/_DDK...
    VEVOR 2.5CFM Refrigerant Vacuum Pump ➡️ s.click.aliexpress.com/e/_DkT...
    Refrigerant Vacuum Pump ➡️ s.click.aliexpress.com/e/_DkH...
    VEVOR 1.8-4.8CFM Refrigerant Vacuum Pump➡️ s.click.aliexpress.com/e/_DeA...
    Mani Fold Gauge
    Digital Manifolds Refrigerant Gauge ➡️ s.click.aliexpress.com/e/_DC3...
    R410A R22 R134a R404A Manifold Gauge ➡️ s.click.aliexpress.com/e/_DeB...
    Refrigerant pressure gauge ➡️ s.click.aliexpress.com/e/_Ddg...
    500/800PSI Refrigerant Manometer ➡️ s.click.aliexpress.com/e/_Dne...
    HONGSEN HS-330 Refrigeration Vacuum ➡️ s.click.aliexpress.com/e/_DBi...
    Air Condition Gauge Manifold ➡️ s.click.aliexpress.com/e/_DFu...
    MRCARTOOL L202 Air Conditioner ➡️ s.click.aliexpress.com/e/_Dkg...
    Soldering stations
    RF4-H2 Automatic Sleep SMD ➡️ s.click.aliexpress.com/e/_DBa...
    JCD 2 in 1 Soldering Station LCD Digital Display➡️ s.click.aliexpress.com/e/_DFz...
    GVDA New Soldering Station ➡️s.click.aliexpress.com/e/_DDc...
    JCD 8586 Soldering Station 2 In 1 Digital➡️ s.click.aliexpress.com/e/_DBX...
    SUGON T21 Soldering Station ➡️ s.click.aliexpress.com/e/_Dne...
    AIFEN A5 Pro Soldering Station ➡️ s.click.aliexpress.com/e/_Dns...
    JCD 750W 2 in 1 Soldering Station LCD Digital➡️ s.click.aliexpress.com/e/_Dl1...
    UYUE T210 Soldering Station LED Digital➡️ s.click.aliexpress.com/e/_DeI...
    Soldering Stations MECHANIC➡️ s.click.aliexpress.com/e/_DmW...
    Desoldering pumps
    LUXIANZI 30w/40w Powerful Electric Desoldering ➡️ s.click.aliexpress.com/e/_DkV...
    Desoldering Pump Suction Tin Gun ➡️ s.click.aliexpress.com/e/_De1...
    110V/220V Electric Tin Suction Sucker Pen ➡️ s.click.aliexpress.com/e/_Ddu...
    Gaqqee 220v 36w Electric Solder ➡️ s.click.aliexpress.com/e/_Dkg...
    ******************************************************************************
    Subscribe to The Channel 👉 bit.ly/3vNT7s3
    Social Links
    Facebook 👉 / forevertech3
    Instagram 👉 / forever_tech1
    Twitter 👉 / forevertech3
    #invertercompressor #refrigerator #compressor #dc #testing #multimeter

КОМЕНТАРІ • 104

  • @selimfolksong
    @selimfolksong 7 місяців тому +4

    I am fridge technician I understand your video my name is Sheikh Selim Uddin. From India thank you so much

    • @thangsgo6938
      @thangsgo6938 6 місяців тому

      Hi brother I have doubt , recently I bought new fridge single door now I'm looking compressor it was have dent and pump,this is danger or its ok pls tell me

  • @joeabad5908
    @joeabad5908 10 місяців тому +5

    Nice to know how common things around us works..
    Thank you for the upload..

  • @gurglejug627
    @gurglejug627 3 місяці тому

    Hi, thanks for your videos. How does one know how much refrigerant to put in a fridge when recharging after a rebuild/modification?

  • @acetech9237
    @acetech9237 Рік тому +2

    You're awesome. I'm a Mercedes Benz tech but I'm always happy to learn more

  • @burhan-00
    @burhan-00 2 роки тому +2

    Merci beaucoup

  • @elkunkhaliil
    @elkunkhaliil Рік тому +3

    Thank you Sir for you efforts to make these videos, i am knew at this and it helps a lot.
    Could you please make a video explaining all parts of the PCP Board and what they do?. Thanks again

  • @abcdefg8336
    @abcdefg8336 8 місяців тому +1

    Thanks for shsring, and how about the rest of the three wires?

  • @ravidu2309
    @ravidu2309 7 місяців тому

    Useful program thanks

  • @mehboobhassan2157
    @mehboobhassan2157 10 місяців тому

    very good information

  • @ANGIEB52
    @ANGIEB52 9 місяців тому +1

    This is the best video for these variable systems… now I know for sure I’m on the right track … 😁 Thank you ..

  • @rolanddejesus8685
    @rolanddejesus8685 10 місяців тому +2

    thanks very much sir for sharing,God bless.

  • @NDUGOD
    @NDUGOD 10 місяців тому +2

    Thanks for the simplification of daunting challenges. Excellent💯👌👌👌👌

  • @naveengopagani361
    @naveengopagani361 Рік тому +3

    🤝Exlent Explan 👍 TQ Sir

  • @Zindagi851
    @Zindagi851 6 місяців тому +1

    This is really good information .thanks

  • @lapovanie
    @lapovanie День тому

    I checked the winding/housing short circuit - no short circuit. I measured the winding resistances and in each case I got 0.0Ω. What could have happened? The compressor is 12V DC

  • @jaybala7493
    @jaybala7493 Рік тому +1

    Thanks sir

  • @wasimedoo7994
    @wasimedoo7994 2 роки тому +1

    Very good information

  • @thomasaquinas6628
    @thomasaquinas6628 8 місяців тому +1

    ok- i have a samsung refrigerator. The "DC" is not correct I think. The compressor is marked "240V 3 phase." That means the inverter board is putting out 3 phase voltage, that is the 3 wires will have all 3 wires have the same voltage between each pair. An inverter doesn't make DC, that would be called a rectifier. The inverter makes 3 phase so the motor doesn't have to have a starting capacitor which can fail. Three phase motors are more reliable than single phase motors. Single phase power is what you have at your house, 120/240V single phase. The inverter turns that into three phase.

  • @johnsutter1497
    @johnsutter1497 4 місяці тому

    We had a flood in the basement. Both fans on the refridgidaire refrigerator work. The compressor does not come on. Could it be the overload switch? Thank you

  • @tesfahungetahunargachew4328
    @tesfahungetahunargachew4328 Рік тому +1

    Nice explaning

  • @AbdurRahim-ir9yz
    @AbdurRahim-ir9yz 9 місяців тому +1

    nice Explain ❤

  • @colbinbarrita288
    @colbinbarrita288 Місяць тому

    My ref standby 3 years,coz no frozen and cold,possible can I repair to function!thanks

  • @haleelah5818
    @haleelah5818 8 місяців тому +1

    Super

  • @grahamswain7356
    @grahamswain7356 6 місяців тому +1

    Very useful information

    • @tbone6354
      @tbone6354 11 днів тому

      It is cheaper to flush with water then no need to vacuum. And add 50ml of sulphuric acid to the compressor

  • @hassanyusuf7280
    @hassanyusuf7280 10 місяців тому +1

    thank you

  • @patriciamateo1733
    @patriciamateo1733 Рік тому +3

    VERY USEFUL, AWESOME

  • @davidharrison6789
    @davidharrison6789 11 місяців тому +4

    Hallo I have notice that compressor winding it has a problem from that measurement you have shown us

    • @davidg.9942
      @davidg.9942 3 місяці тому

      Hi, it is inverter compressor, it has to have identical reading in all 3 points. It is not a typical C S R with 50-60 Hz where you Identify Common Start & Run readings. Inverter compressor runs on 40- to about 180 Hz on 240v and thus to see if compressor winding is still good reading has to be identical or within 0.1-0.2 ohm on all 3 connections. Body short you check the same way as old one.

  • @innocenthumans3721
    @innocenthumans3721 Рік тому +1

    Pcb light blinks twice. N pcb is ok technician said compressor needs replacement where as compressor showws right reading. Can u help

  • @NiceRepairGuys
    @NiceRepairGuys Місяць тому +1

    Good to know

  • @GodknowsSumaina
    @GodknowsSumaina Місяць тому

    What will be the problem if the compressor winding reads ok and we have 120 volts on the compressor terminal a d the compressor doesn’t want to run; the overload is fine

  • @michaelyawkal4592
    @michaelyawkal4592 Рік тому +1

    Nice

  • @GodknowsSumaina
    @GodknowsSumaina Місяць тому

    I have exactly this fridge with an inverter compressor, the overload is ok, the re is power on the compressor terminals , the winding resistance is ok but the the compressor won’t run; what should I do to get it running? Thanks

  • @jonathanrobinson5348
    @jonathanrobinson5348 9 місяців тому

    I have a Samsung fridge family hub model rf265beaesr it was working but suddenly when you plugged it the compressor sounds like star running then shut down right away, then the touch screen have a code 84c compressor locked over RPM. Then the compressor you can hear that it's running but very slow you barely can hear it. But nothing nothing its working inside the fridge. What can I do?

    • @forevertechenglish
      @forevertechenglish  9 місяців тому +1

      First of all check the compressor, As I have told in the video. If the compressor is ok. Look for the any wire that's been lose connection or cut attached with the compressor. If everything is ok. If you have another compressor attach that with the motherboard to verify that the motherboard is good. If you attach that new compressor and it works. Means your old compressor is bad. And need replacement.

    • @MBihon2000
      @MBihon2000 6 місяців тому +1

      Buy a new replacement.

  • @tbone6354
    @tbone6354 2 місяці тому

    A good idea is to fill the compressor with water before regassing to reduce corrosion

  • @Defectordrunkzone
    @Defectordrunkzone 8 місяців тому +2

    How is that possible?
    The terminals should have different values.
    If so how could someone identify which terminal is which?

    • @tonyp6088
      @tonyp6088 4 місяці тому +1

      You are absolutely correct. There are 3 terminal pins, 2 windings within the compressor which are connected to the common terminal, (which is usually the pin at the top).
      If you measure from the bottom left pin to the top pin that will give you the resistance of the start winding.
      Bottom right pin to top pin will give you resistance of the run winding. And the bottom two pins together will give you the total resistance of both windings as they are both connected internally to the common (top pin).
      All values should be different but check manufacturers specifications to be sure.

    • @davidg.9942
      @davidg.9942 3 місяці тому +1

      Hi, it is inverter compressor, it has to have identical reading in all 3 points. It is not a typical C S R with 50-60 Hz where you Identify Common Start & Run readings. Inverter compressor runs on 40- to about 180 Hz on 240v and thus to see if compressor winding is still good reading has to be identical or within 0.1-0.2 ohm on all 3 connections. Body short you check the same way as old one.

  • @ilkertokgoz2465
    @ilkertokgoz2465 Рік тому +1

    Thanks

  • @abuasfur7334
    @abuasfur7334 3 місяці тому

    Hello I done all the checks everything is ok but the overload is rattling when it is shaken is that normal?

  • @user-saadmahdi
    @user-saadmahdi Рік тому +1

    What types of motor
    Induction or BLDC

  • @thangsgo6938
    @thangsgo6938 6 місяців тому

    Hi brother I have doubt , recently I bought new fridge single door now I'm looking compressor it was have dent and pump,this is danger or its ok pls tell me

  • @lnglng6961
    @lnglng6961 4 місяці тому

    ❤❤❤

  • @abdulrasheed3424
    @abdulrasheed3424 7 місяців тому

    So inverter compressor working in dc voltage?

  • @halimsaid5718
    @halimsaid5718 6 місяців тому

    سلام ممكن تحدث عن ثلاجة lg smart inverter وشكرا وميض 8 مرات

  • @user-ly2zu2mx7s
    @user-ly2zu2mx7s Місяць тому

    There are always the reasons behind why electrical failures happen. Without explaining them, such as the large resistance difference in this case, your fixing skills do not get any further.

  • @LuchambeeLuchambee
    @LuchambeeLuchambee 7 місяців тому

    Chequeo de refrigerador

  • @crazysquirrel9425
    @crazysquirrel9425 10 місяців тому +4

    Just another reason to avoid any refrigerator that has electronics in it.
    Far too many points of failure. And those boards are very EXPENSIVE, IF you can even get one when you need it.

    • @MBihon2000
      @MBihon2000 6 місяців тому +1

      You can't find a ref with no electronics board on it. Unless you are buying a 70 year old ref.

    • @crazysquirrel9425
      @crazysquirrel9425 6 місяців тому

      @@MBihon2000 My refrigerator certainly is not 70 years old.
      Closer to 25-30 years old maybe.
      I have converted refrigerators from electronics to mechanical many times.
      Electronics ones lasted a year or so. Mechanical conversions are still working even today.
      If I can find a decent one with coils up the back, I would get it.
      Less moving parts and no electronics.

    • @louisdreyer7523
      @louisdreyer7523 2 місяці тому +1

      Agree 100%

    • @crazysquirrel9425
      @crazysquirrel9425 2 місяці тому

      @@MBihon2000 Some refrigerators can be converted back to non electronic.
      Ever hear of a non electric refrigerator?

  • @fritzmoise178
    @fritzmoise178 7 місяців тому

    Can I have a price for this compressor

  • @sonu.labrez
    @sonu.labrez 2 роки тому

    Sir isko Hindi me ap batate na

    • @forevertechenglish
      @forevertechenglish  2 роки тому

      We have Already made a video on this topic in Hindi visit channel forever tech
      Or video link ua-cam.com/video/9uM8mXaSKeU/v-deo.html

  • @BhalaneDlamini
    @BhalaneDlamini 7 місяців тому

    My fridge does not get cool but deepfridge section is alright

  • @louisdreyer7523
    @louisdreyer7523 2 місяці тому +1

    The best method of testing a compressor is with a Megger. Two faults occur on a compressor are : winding to winding short and winding to chassis. A normal multimeters' voltage goes up to 9 volt. Where a meggers' voltage goes up to a 1000v. When testing with a Megger you won't go higher than 500v. So a megger is much better to use.

    • @forevertechenglish
      @forevertechenglish  2 місяці тому +1

      I already have made a video on megger and the multimeter posted on the channel

  • @MajidKhan-gi7my
    @MajidKhan-gi7my 2 роки тому +1

    Ustad g ap apna num to day Mara ap se kam hai urgent

    • @forevertechenglish
      @forevertechenglish  2 роки тому

      ua-cam.com/video/oUV8s4q9lt8/v-deo.html
      Is video main mera no majood hai

  • @ramasamyramachandran5847
    @ramasamyramachandran5847 Рік тому +1

    Translate in tamil pls

  • @user-kj1od5ed7p
    @user-kj1od5ed7p 13 днів тому +1

    You should get somebody that's very fluent in English to make sure you get the best computer voice translation from text

    • @forevertechenglish
      @forevertechenglish  13 днів тому

      This is an old video; you can check out some of the new ones. They have better voiceovers.

    • @nadeem5476
      @nadeem5476 6 днів тому

      why English????
      learn Chinese or his language.
      2 H W English

    • @user-kj1od5ed7p
      @user-kj1od5ed7p 6 днів тому

      @@nadeem5476 whatever floats your boat my comment was criticizing the quality of the text to speech artificial intelligence voice system or whatever he was using

  • @user-kj1od5ed7p
    @user-kj1od5ed7p 13 днів тому

    Why do you use a crappy computer voice

  • @CFPVideoProductions
    @CFPVideoProductions 2 місяці тому

    Please use real people to do your voiceovers. This robot should be deleated. Your products are depending on the warmth and proper human voice and not an AI monotone presentation.

  • @kettogeerman174
    @kettogeerman174 6 місяців тому

    I have Never heard of a threephase D.C. motor. Stop teaching "NONSENCE" D.C. does not have frequency. A.C. has frequency. Where have you bent to school? What a"SHAME"

    • @forevertechenglish
      @forevertechenglish  6 місяців тому +2

      3 phase refers to the number of electrical phase windings on the motor. It is switched via a 3-phase power "bridge" from a DC voltage supply. This "bridge" consists of 6 power devices - normally IGBTs, but sometimes MOSFETs. They use pulse-width modulation to control the power, and the order in which the 3 motor phases are energized determines the direction of rotation.

    • @forevertechenglish
      @forevertechenglish  6 місяців тому +1

      The terms AC and DC can describe signals as well. An AC signal is a current, voltage, or numerical sequence that consistently exhibits both positive and negative values, and a DC signal exhibits only positive values or only negative values.

  • @vettalan
    @vettalan Рік тому +2

    Bro,that is not overload.it is overload protector