Inverter Refrigerator Compressor Direct Start & UVW Testing | Embraco Fridge Board

Поділитися
Вставка
  • Опубліковано 16 гру 2024

КОМЕНТАРІ • 86

  • @conradogoodwin8077
    @conradogoodwin8077 Рік тому +9

    Incredibly clear explanations, thanks!

    • @forevertechenglish
      @forevertechenglish  Рік тому

      You're very welcome!

    • @wasimedoo7994
      @wasimedoo7994 Рік тому

      Is there any way else to start and run the invertor compressor with out the board if the board damage

  • @nols3726
    @nols3726 Рік тому +1

    I have a inverter fridge 30 cubic 5 yrs ago it just stop cool. My technician said I need a compressor and Control Board. I am in Carribbean I buy it at pc Richard USA. I am learning you explain it so good I understand very well.

  • @troubleshooter1975
    @troubleshooter1975 11 місяців тому

    Very good video. I learned a lot!
    Only mentioning some minor technical, or translation errors so that no one gets confused:
    @3:30 Just to clarify, the inverter board generates "3-phase" AC power, in the vicinity of 230VAC [not DC].
    @TheNYgolfer also posted this already - thank you.
    I'm not sure what he is showing in the drawing of a board output waveform, but there are many excellent diagrams of 3-phase power on the internet.
    As he drew that, it would represent a single phase (of the three).
    [It also slopes 'backwards in time' at one place, but it is hand drawn. I just didn't understand what aspect he is illustrating.]
    @4:45 To clarify, he is using 240VAC, not DC, to power the board. Brown is more properly referred to as 'hot' or 'live', and not 'positive', which is misleading and can be confused with DC where the term 'positive' actually means 'positive' DC polarity.
    [I also came across someone calling the live as 'phase', and the other as neutral.]
    He has 240VAC showing on his meter, but refers to it as 220V; doesn't matter -they rate them for 220V-240V input anyway.
    [What country are you in fine sir?]
    I only mention it because I have had some people get confused by voltage ratings...
    1:40
    3:09
    3:57
    Mr K L

  • @broncheemims8493
    @broncheemims8493 2 роки тому +5

    Sir I like the way you explain things electrically. I have a degree in electronics,so it helps troubleshoot the board more accurate.

  • @Goughk
    @Goughk Місяць тому +2

    Thank you so much.have to learn so much from you😢

  • @debdymilanez9418
    @debdymilanez9418 Рік тому +2

    Parabéns pelas explicações 👏👏👏👏🇧🇷🇧🇷🇧🇷🇧🇷🇧🇷🇧🇷

  • @vadimtyutyunnik353
    @vadimtyutyunnik353 2 роки тому +5

    You said at 3:40 - it works on 220VDC 40-160Hz.
    Why we call it DC when it has some frequency??

    • @TheNYgolfer
      @TheNYgolfer Рік тому +1

      He misspoke. He meant 220VAC.

  • @josecarlosmejia9632
    @josecarlosmejia9632 10 місяців тому

    GREAT INFORMATION FOR IMPLEMENT ON SCHOOL OF TECHNICIANS ABOUT INVERTES THANK YOU

  • @tambejohn7382
    @tambejohn7382 Рік тому +2

    Thanks alot for the lessons

  • @uru-freemind7711
    @uru-freemind7711 6 місяців тому +2

    Los motores trifásicos se pueden operar como monofásicos con capacitores... Se podría operar el motor inverter con capacitores sin placa?

  • @sofroniocarranza6064
    @sofroniocarranza6064 Рік тому +3

    Thank you for all you done I seen your mother board trouble shooting is a near place where to buy New mother board of Samsung inverter how much cost most client rush to fix.

    • @forevertechenglish
      @forevertechenglish  Рік тому

      This A Good question But I Usually repair them, Buying a new one you could ask the samsung's service center for the motherboard

  • @francoisguyot9770
    @francoisguyot9770 Рік тому +1

    Just the info I needed.! Thx

  • @ferozenoordeen3711
    @ferozenoordeen3711 Рік тому +3

    Thanks for the training...
    Please explain the input DC voltage to the compressor in your next lesson .
    Regards...

  • @robeltsegaye1505
    @robeltsegaye1505 Рік тому +2

    Thanks 4 the uvw tester im using it its effective if u can i would like u to explain winding of washing machine motor and how to know the truns of the burned coil and the other thing is this week i bought fixit ic programmer please make some videos how to install the fixit programmer software on pc and where to find the programs

  • @tesfahungetahunargachew4328
    @tesfahungetahunargachew4328 Рік тому +1

    Tnx sir for your presentation have a good new year

  • @venkateswarludantha6702
    @venkateswarludantha6702 Рік тому +3

    Hi sir very nice video. Iam venkatesh 🇮🇳india

  • @strimearts6998
    @strimearts6998 9 місяців тому +1

    Hello, great video.
    I have a gn162430x - 5645512900 Inverter PCB. Is there a way to start it manually? My compressor seems to be fine, just there is no volatage output at the UVW pins. thank you

  • @SilvioTomazdeAquinoTomaz-sc2mi
    @SilvioTomazdeAquinoTomaz-sc2mi 10 місяців тому +1

    Know a lot, congratulations!

  • @charlesnokae6987
    @charlesnokae6987 Рік тому +1

    Your explanation is very helpful 💯👍🏾.
    Please would you please kindly help me out with a Cubigel Compressor - NUT125FSC is not working and it's PCB green led light blinking and my colleagues were assuming that the compressor is faulty due to voltage changes during startup and compressor not cut in.

  • @ugochukwu-uf6iv
    @ugochukwu-uf6iv Рік тому +2

    Thanks very rich in content sir

  • @katchutarao4313
    @katchutarao4313 11 місяців тому

    This video very use full thank you sar

  • @16valve64
    @16valve64 2 роки тому +2

    Thanks a lot for sharing your thoughts

  • @godalmighty-lm2yt
    @godalmighty-lm2yt Рік тому +2

    Please I like the way you explain things, am a Technician in refrigeration and air conditioning and also washing machine aspects but sir I have little problem with HITACHI twin refrigerator, The compressor will start and goes off immediately please may I know the courses of this problem .
    Emmanuel.

    • @forevertechenglish
      @forevertechenglish  Рік тому

      Well dear I could not say anything this way, But if this refrigerator has a PCB board, it could be faulty, Check for a lose wiring connections, check the compressor, the relay. If everythings ok, If it has a PCB, Then the PCB board could be bad. Let me know then.

  • @jaybala7493
    @jaybala7493 2 роки тому +2

    Sir thank you very much

  • @AnUnapologeticApologist
    @AnUnapologeticApologist Рік тому +1

    If you have the inverter connected normally, except for the female connectors that connect to the compressor windings, once the unit is plugged in what voltage should you expect to see from the female connector on any lead to another? My condenser fan will power on but the compressor will not. Resistance is good on every winding, no short to ground. Power from the female connector that goes to compressor reads 14VAC applied. I believe the inverter is the issue

  • @mhandrabat331
    @mhandrabat331 Рік тому +2

    سلآم عليكم ورحمة الله وبركاته استادي الكريم هل ممكن تشغيل الضاغط انفرتر بدون كارت الكنترول

  • @rolanddejesus8685
    @rolanddejesus8685 2 роки тому +1

    thanks a lot sir for sharing...God bless.

  • @ateseteknik621
    @ateseteknik621 3 місяці тому

    Merhaba videolarımız Çok bilgilendirici ancak size bir şey sormak istiyorum kırmızı kablonun yanındaki siyah kabloya anakarttan kaç volt geliyor acaba ya da o siyah kablo ile anakart arasındaki iletişim hakkında da bir video çekerseniz çok memnun olurum Saygılarımla

  • @SZahi-hi6ew
    @SZahi-hi6ew Місяць тому

    What type of of PCB board you are using with best regards

  • @HeartyLindo
    @HeartyLindo Рік тому +1

    How about the single wire from speed switch it is the same?also connect in neutral the red wire from speed switch?

  • @Adam90155
    @Adam90155 Рік тому +2

    Super film 😁gdzie moge kupic taka płytke sterującą?

    • @Waldemar_Pachol_official
      @Waldemar_Pachol_official Рік тому +1

      Fejk! Film ukradziony z indyjskiego kanału. Płytka też fejkowa - brak modułu SD30Mxxxx.

    • @Adam90155
      @Adam90155 Рік тому

      ​@@Waldemar_Pachol_officialwitam może Pan wie gdzie mogę kupić płytke sterująca sprężarkę inwertorową na krótko? Pozdrawiam

  • @nick-firstest
    @nick-firstest Рік тому +1

    Is regular gas generator(without inverter) can run refrigerator without any harm?

    • @forevertechenglish
      @forevertechenglish  Рік тому

      Yes it do run the refrigerator without any harm, But it is not Bill or electricity friendly.

  • @muhammadatifsafdar
    @muhammadatifsafdar 6 місяців тому

    Much informative!!

  • @zawrialangosman6804
    @zawrialangosman6804 2 роки тому +2

    Best video

  • @martingates6501
    @martingates6501 Рік тому

    One question, I'm testing an LG inverter compressor like you did in this video and the compressor start and everything's ok, but the discharge is too weak, it's because doesn't has refrigerant or the compressor is not good?

  • @mikefreedom5612
    @mikefreedom5612 Рік тому +2

    Thank you
    How can I get that boarx?

  • @thomasoconnor-cs3ee
    @thomasoconnor-cs3ee 5 місяців тому

    So when you join the 2 points of the optocoupler the thermostat doesnt need to be connected?

  • @seshachary5580
    @seshachary5580 9 місяців тому +1

    very educative. Thank you

  • @kumudiniwasanthi1952
    @kumudiniwasanthi1952 Рік тому +1

    Super

  • @abdohajj5135
    @abdohajj5135 Рік тому

    Nice thx to you❤❤❤

  • @gerryyulo
    @gerryyulo 9 місяців тому

    The voltage on the 220v compressor reads only 150v coming from the inverter of Electrolux freezer-fridge, what do you think seems to be the problem, can it be on the inverter module or on the main module? I'm a DYI'er

  • @lasanthabandara7455
    @lasanthabandara7455 2 роки тому +3

    How to check the timer side to see if the timer is working properly

    • @forevertechenglish
      @forevertechenglish  2 роки тому

      Dear in the video we do not talk about any timer we talking about thermostat if you want to know about thermostat let me know

  • @SNBBank
    @SNBBank 3 місяці тому

    I have one question same way to check dc fcu fan moter also

  • @hadjnabil4811
    @hadjnabil4811 Рік тому +1

    than you lot's😘

  • @harunrashid8796
    @harunrashid8796 Рік тому

    Thanks a lot.

  • @RecoveryAccount-k4z
    @RecoveryAccount-k4z 18 днів тому

    Nice sir

  • @softsilver2346
    @softsilver2346 2 роки тому +2

    Good

  • @jgc12154631
    @jgc12154631 3 місяці тому

    This inverter board can't change the frequency? Just on & off?

  • @nhiduong1040
    @nhiduong1040 2 місяці тому

    Thanks

  • @odrixscaba3519
    @odrixscaba3519 22 дні тому

    Where can i send my board to fix to you

  • @anassyria5176
    @anassyria5176 9 місяців тому

    Hello sir from Syria
    Is it safe to run a refrigerator with inverter-driven compressor with a square wave AC?

  • @negasheshetu5627
    @negasheshetu5627 Місяць тому

    Thanks allot

  • @hugocornejo5757
    @hugocornejo5757 11 місяців тому

    Cómo saber de qué lado puentear el optoaclopador?

  • @EveSherman-x1j
    @EveSherman-x1j 2 місяці тому

    Dulce Forges

  • @JaysonPagador-gd5mm
    @JaysonPagador-gd5mm 9 місяців тому

    How can I find the compressor wuv no sign in compressor sir

  • @sonu.labrez
    @sonu.labrez 2 роки тому +1

    sir ye video hindi me dalo na

  • @wasimedoo7994
    @wasimedoo7994 Рік тому +2

    Good information friend but I don't get any part to replace on that board but I saw a video on tube some guys run the invertor compressor with acopositor 4uf and 220 vote can it work thanks God bless 👍

    • @troubleshooter1975
      @troubleshooter1975 11 місяців тому

      Yes, testing a 3-phase motor on single phase power 'can' be done, in certain circumstances (with a capacitor sized properly for the motor being tested).
      BUT, the power will be badly unbalanced, and power factor and currents will be way off from safe design ratings. (another words, the current through the windings will not match, will likely be excessive, and the timing of the current flow will be out of sync - it will be 'out-of-step' with the rotation!).
      [also, if you phase it wrong, the motor WILL run backwards... It may run fine, but not oil itself!]
      This almost always will create excess heating of the motor, quickly overloading it.
      You could possibly burn it out in minutes!
      Test it this way only long enough to determine that it is rotating and producing flow and pressure (like a few seconds to half a minute). -To confirm that the motor can run...
      Then find the other reason the motor is not getting proper power.
      Mr K L

  • @martineseddington4908
    @martineseddington4908 2 місяці тому

    58799 Mosciski Trail

  • @LMR5826
    @LMR5826 Рік тому

    Quality Distributor #2 Westminster Road.kingston. all inverter Parts are there.