  • @ilmarinenkarel1317
    @ilmarinenkarel1317 4 роки тому +3

    One of the best man, who teach us how build in right way, grt thnx from Russia

  • @jsndnstube
    @jsndnstube 3 роки тому

    One of the best topic....very well explained....

  • @archbongberin6744
    @archbongberin6744 3 роки тому

    Your title might be confusing; You wrote "bent up bar in STEEL STRUCTURE" but your topic discusses REINFORCED CONCRETE DESIGN. But anyway your explanations are reliable. Thanks man....

  • @tauqeeralam3556
    @tauqeeralam3556 4 роки тому +3

    But I have a question you are telling to keep spacing less in bottom and top and more in mid but according to bending moment moments is zero at mid and we provide lapping there but how we can spacing more at mid can you explain please.

  • @mustaphaabdulhakeem4186
    @mustaphaabdulhakeem4186 3 місяці тому

    Thank you sir, these has really help

  • @JffrsnNyk
    @JffrsnNyk 4 роки тому

    Very helpful. 👍🏻

  • @aliqadri4672
    @aliqadri4672 3 роки тому

    Is cantilever beam or over hanging beam are they same..??

  • @engr.a.j.rahmani5275
    @engr.a.j.rahmani5275 3 роки тому

    Nicely explained lecture. thnx.

  • @ahsanbinalrahmanfromairara9868
    @ahsanbinalrahmanfromairara9868 4 роки тому

    Mashallah Sir Ji
    Allah Bless You 🤧

  • @lalchhanchhuahachawngthu8499
    @lalchhanchhuahachawngthu8499 2 роки тому

    Do i need to provide crank bar between two columns if the distance between two columns is 12 feet?

  • @afnanqureshi2149
    @afnanqureshi2149 3 роки тому

    Sir long beam with out column bana sakhty hay or is kalya kiya zaruri hain

  • @junkun1393
    @junkun1393 3 роки тому

    do we need to make a bent bar also on the 3rd floor if the floating coloumn is continous?

  • @aliqadri4672
    @aliqadri4672 3 роки тому

    What if we provide 2 floting colums on one beam between two main colum can we provide two floting colum by giving 2 bentup bars in one beam or 2nd is only giving one long span bentup bar for two floting colum which is right can we give two floting colum in one beam or not..plz reply

  • @aliqadri4672
    @aliqadri4672 3 роки тому

    Sir it is important to provide floting colum on down side of crank bar ..and does floting colum require crank up baars in beam..?

  • @MohsinExperiments
    @MohsinExperiments 3 роки тому +1

    Video Starts from here 2:40

  • @reshinayeem9550
    @reshinayeem9550 4 роки тому

    sir,can u able to provide slab on these colums which are placed on beams..plz suggest..i have to shift column on beams.

  • @veeramaniduraisami3768
    @veeramaniduraisami3768 2 роки тому

    👍🏼 thanks sir

  • @sampathg8563
    @sampathg8563 2 роки тому

    Sir namaste 🙏
    I want to know the middle of the beam if we provide the columns, the bent of bar length not mentioned can u help us with that point

  • @rahulbhasi609
    @rahulbhasi609 Місяць тому

    Thank uuu

  • @galherpras
    @galherpras 4 роки тому

    waalaikumsalam... very helpful. Thank you!

  • @girofm9590
    @girofm9590 4 роки тому

    Muchas gracias por la información!

  • @ahmedbenlarbi2348
    @ahmedbenlarbi2348 Рік тому

    Please , how to determine the length of bent up bars , the slope of the bars and the total length of the main bars of columns on beam .
    Thanks.

  • @arbaz28
    @arbaz28 4 роки тому +1

    hello
    can you make an video on design of shear wall as per ACI 314-14

    • @mpannirselvam9512
      @mpannirselvam9512 2 роки тому

      Pl what is the size of the pillar snd beam for 36 feet width.

  • @CHANNEL-cf2oh
    @CHANNEL-cf2oh 4 роки тому

    Thanks a lot sir for the information. I have came across other articles and it turns out that there is a tipical bent up bar that we also call hanging bar wich is provided in intersection between main beam and secondary beam. The purpose of the hanging bar is to reduce the shear into the main beam if it is of a great amount.
    Can a hanging bar take another vertical load as the column?

  • @buildingdesign.5924
    @buildingdesign.5924 2 роки тому

    Thank you

  • @bipinpatra3803
    @bipinpatra3803 4 роки тому

    Thank you sir.

  • @TinTin-bq1lb
    @TinTin-bq1lb 2 роки тому

    Sir how about the length of the bent up bars?

  • @sharif5l827
    @sharif5l827 3 роки тому

    sir iam your big frind

  • @ericboysinelgache7892
    @ericboysinelgache7892 3 роки тому

    What is the span of beam

  • @niyazali4254
    @niyazali4254 4 роки тому

    Will u plz do same video in Rcc structure

  • @aa-we4yz
    @aa-we4yz 4 роки тому

    Sir one side column 4/16d another side column 4/12d how to design Sir

  • @tayabhussenee5974
    @tayabhussenee5974 3 роки тому

    hello you did not tell the lenght to bent up bar how and where to to calculate

  • @saiteja5356
    @saiteja5356 4 роки тому

    Sir what is a dowel bar. What is the importance of a dowel bar . How is dowel bar different from an anchorage bar. Where is it provided . Please make a video on this

  • @VAIBHAVSPAL
    @VAIBHAVSPAL 4 роки тому

    Thanks sir 🙏

  • @anoopameer3145
    @anoopameer3145 4 роки тому

    great

  • @ameerm4899
    @ameerm4899 3 роки тому +1

    I thought you could just use extra bars instead of bent up bars to improve strength

  • @engineerajaytech6469
    @engineerajaytech6469 4 роки тому

    Walecum Salam sir

  • @mohammadkhorshedalam133
    @mohammadkhorshedalam133 4 роки тому +1

    Video is not fully clear.

  • @mohsinmalik7830
    @mohsinmalik7830 4 роки тому +2

    Yr urdu mi samjya kro

    • @mxolisimagaba5233
      @mxolisimagaba5233 2 роки тому

      How do I add a column on top of a column supporting a slab?

  • @vincentpereira8416
    @vincentpereira8416 2 роки тому

    I thought it was 135 degree