Can Set Up and Hold Time be negative? | STA | Back To Basics

Поділитися
Вставка
  • Опубліковано 4 лют 2025

КОМЕНТАРІ • 32

  • @nikhilkake7931
    @nikhilkake7931 4 роки тому +3

    I think you missed telling which one is danger either setup -ve or hold -ve. And if u given conclusion as setup -ve value is accepted but not for hold. Nice explanation, easily understand for freshers. :)

  • @hakobmanukyan8233
    @hakobmanukyan8233 3 роки тому +1

    You were explaining very well

  • @niroshaj.r.1730
    @niroshaj.r.1730 5 років тому +9

    Mam can u do next videos on sdc contents , static and dynamic power Dissipations please

  • @064chilukuriaditya3
    @064chilukuriaditya3 3 роки тому +2

    super understood it very clearlyy

  • @sharathreddyvancha1577
    @sharathreddyvancha1577 4 роки тому

    If clock is delayed, then the transmission gate will be turned after 5 ns and the data can be transferred only after TG is turned On and the setup time will be 3ns right, the clock delay can only cancel out delay due to Scanin combinational logic. It doesn't affect the original setup time. Correct me if I missed something

  • @doepic8147
    @doepic8147 5 років тому +2

    Mam please make a video on end cap cell.

  • @rajdeepvartak7826
    @rajdeepvartak7826 Рік тому

    But this data combination logic is outside flip-flop then how we will consider if for negative hold flip flop?

  • @avinashvinith84
    @avinashvinith84 5 років тому +2

    It was a very good explanation.

  • @emipushpam9417
    @emipushpam9417 5 років тому +2

    Nice explanation.

  • @subhamnayak4726
    @subhamnayak4726 4 роки тому +1

    excellent ma'am

  • @sivasiitb
    @sivasiitb 4 роки тому

    It can be 0 but not negative. Unless the clock is there how the gate opens and reach both the inverters?

  • @ayushsrajput301
    @ayushsrajput301 4 роки тому +1

    Thanks a lot 😁

  • @rohitkumarthakur2793
    @rohitkumarthakur2793 5 років тому +1

    Can u make video on calculation of derate

  • @shashankkhope2289
    @shashankkhope2289 11 місяців тому

    can addition of hold and setup time be negative?

  • @mohangowda4282
    @mohangowda4282 4 роки тому +1

    hi mam , there is a typo error in last slide , it should be hold not setup for last two conditions

  • @guruprasadreddy7570
    @guruprasadreddy7570 3 роки тому

    excellent madam👏

  • @sathwikpothana2184
    @sathwikpothana2184 3 роки тому

    How can setup time and hold time can chage they being constants?? I believe rather saying setup and hold time negative we should say hold slack and setup slack can be negative. Correct me if iam wrong.

  • @DalasYoo
    @DalasYoo 4 роки тому +1

    I just wonder how the setup time negative related to the skew. When seeing the timing report, we always tell that the negative skew is violation. Isn't this same meaning to have setup time negative?

    • @pavantv749
      @pavantv749 3 роки тому

      I can say we get negative clock skew due to routing path of clock for the two consecutive flipflops

  • @uday5786
    @uday5786 5 років тому

    can u expain in timing analysis

  • @jahnuchoudhury6677
    @jahnuchoudhury6677 4 роки тому

    Ma'am .. here Cp is the clock path delay for the clock of first transmission gate... and transmission gate in the loop has no clock path dalay... am I right ??

  • @ajaykodipelli8617
    @ajaykodipelli8617 4 роки тому

    Hi Mam.. does negative and zero values of setup and hold, violates the functionality

  • @rohitkumarthakur2793
    @rohitkumarthakur2793 5 років тому

    Good explanation

  • @govindmr1984
    @govindmr1984 2 роки тому

    always we will get only setup violation but hold violations come into picture after cts ? why

    • @backtobasics5602
      @backtobasics5602  2 роки тому

      Hold only comes into picture when the clock tree gets built, due to skew, since skew is the major cause of hold violations. Since the clock is ideal in place(skew will be 0), there won't be significant hold violations at place.

  • @seelamnarendrareddy8982
    @seelamnarendrareddy8982 5 років тому

    Can you tell about sdc file

  • @udayv1301
    @udayv1301 5 років тому +1

    0:12 without any further delay hahaha

  • @KavitaSharma-wm7wq
    @KavitaSharma-wm7wq 5 років тому

    How to calculate setup time for any flop .. where we can find the setup value for particular flop.?

    • @lokeshamara2788
      @lokeshamara2788 5 років тому +1

      From the lookup tables in .lib file, setup_time or hold time =f(data_transition,clock_transition)

  • @travelfreakphani5933
    @travelfreakphani5933 6 місяців тому

    pichikeka