Air-Purger Replacement

Поділитися
Вставка
  • Опубліковано 30 кві 2018
  • In this video I show how to replace your old air-purger with a new one.
    Amtrol Air-Purger
    amzn.to/2rijyn9
    Spirovent
    amzn.to/2jlehaJ
    Milwaukee USB Rover
    amzn.to/2qVmea2
    Milwaukee Screwdriver Set
    amzn.to/2JkBKUd
    Milwaukee ProPress
    amzn.to/2HEhNLS
    Milwaukee Cheater Pipe Wrench
    amzn.to/2Kpq5F4
    Ridgid Pipe Wrench
    amzn.to/2KqtvHG
    Milwaukee Open-Ended Adjustable Wrench
    amzn.to/2KpFKnU
    Vise-Grip Pliers
    amzn.to/2HLwI2K
    Dewalt SawZall
    amzn.to/2JKgzLt
    Deburring Tool
    amzn.to/2HLPtD8
    Knarly Carl
    ua-cam.com/channels/Pdn.html...
    Our Website
    www.kjcomfort.com
  • Фільми й анімація

КОМЕНТАРІ • 80

  • @wyliecoyote1
    @wyliecoyote1 9 місяців тому

    Thanx for the boiler system vent lesson, browsing around to various UA-cam clips and learning lots. Looks like great work, subscribed.👍

  • @johnpike2778
    @johnpike2778 Рік тому

    Great video I replaced my air vent valve today with your help. Nice job.

  • @philipfm
    @philipfm 3 роки тому

    Great video. I wish they had these when i was a homeowner

  • @Shahrdad
    @Shahrdad 3 роки тому +8

    You need at least 18" of straight pipe before the air separator for it to work properly.

  • @nheng6913
    @nheng6913 Рік тому

    The ProPress is all the rage due to the time it saves. The only time I care about is how long my system lasts. I don't like the distortion in the copper from the press. It's setting up stress points in the copper, which may already be stressed from age. Other than that, just learned from you that my Sawzall is a plumbing tool. Good video !

  • @kennynvake4hve584
    @kennynvake4hve584 3 роки тому

    Not many people have a 3500$ pro press....it would have been nice to see the old fashion way of soldering it...nice video tho...thanks....Use to use a pro press everyday at work..and it saved hours and hours of work and time...especially installing a new burner.

  • @marial4707
    @marial4707 4 роки тому +2

    Best vid around on how to do this work! Still looking on how to replace the air float valve at the top of the line and also how to clean/upkeep those damn things! Any videos you can replace the float type air vent would be greatly appreciated!

    • @kevinrafferty9748
      @kevinrafferty9748 4 роки тому +1

      Send me a picture of which one you'd like a video of and I'll make one. sales@kjcomfort.com

  • @georgeashby8523
    @georgeashby8523 6 років тому +1

    Great videos, please keep up the great work! Can I also ask where did you get the reaming tool for copper (the one that looks like a J hook pick? Great videos!

    • @KJsComfortInc
      @KJsComfortInc  6 років тому

      Thank You! It’s called a deburring tool and I have updated the description bellow the video with a link to buy one.

  • @320ceman
    @320ceman 3 роки тому +1

    Good job , the only thing I would have done is repipe the feed water into the correct location , between the expansion tank and scoop valve

  • @user-ut3uy3oo9u
    @user-ut3uy3oo9u 7 місяців тому

    great video... thanks for sharing.

  • @nelsonechevarria7009
    @nelsonechevarria7009 3 роки тому

    Good video,I hope you don't mind me saying that you should have replaced that boiler drain valve while you were there changing the air scoop and the expansion tank.God bless you and yours and thank you for the video.

  • @johnal4560
    @johnal4560 2 роки тому

    Hi i recently did service to my water floor heating radiant I changed the expansion tank the pressure vale changed the Honeywell zones the zones are calling and the pressure gauge stays just 2 line above the 20 and staying there and i did flashed the water from all zone lots of dark water came out and i left it to open tell water color got back to normal but the issue i have is the first floor which got 2 zone both zone got warmed but the upstairs only get to 10 degree does not matter if i leave the tramontane all the way to the end or levee it on 20 so what cold be wrong what do u suggest please Thanks

  • @stevebabcock7353
    @stevebabcock7353 2 роки тому

    How do you know what pis to set the expansion tank at?

  • @KameraShy
    @KameraShy 3 роки тому

    This chucklenead:
    1. Did not use eye protection when using a sawzall to cut pipe
    2. Just left wires dangling in his face instead of taping them neatly to the pipes. In computer building it's called cable management.

  • @patcupolo9274
    @patcupolo9274 Рік тому

    Love ball valves wasn't the air scoop replaced better than new one 10 year retired oil man from Long Island like the way you work

  • @bobthebuilder201
    @bobthebuilder201 Рік тому

    Do you have to shut off the power to the unit before doing this?

  • @2502860
    @2502860 2 роки тому +1

    U didn't explain the precharge for expansion tank requirements

  • @tuppersdad
    @tuppersdad 2 роки тому +1

    The spirovent is a much better product that air scoop is almost useless in that location.

  • @MyGodzilla33
    @MyGodzilla33 Рік тому

    Doing replacement on the expansiontank don't need to put air in?

  • @olddave4833
    @olddave4833 3 роки тому +2

    great job

  • @johnem4695
    @johnem4695 4 роки тому +1

    air scoop and hyvent is a much better set up. nice work

  • @omarsharif2456
    @omarsharif2456 3 роки тому

    I like diy plumbing job around my house but these boiler related jobs i always call professional

  • @davesingh8085
    @davesingh8085 3 роки тому +1

    I saw that expansion tank is on the output hotwater side of the boiler Is that air tank be ok to take that much hot water with the plastic air bladder inside that tank ? That's the first I ever seen.

    • @kevinrafferty9748
      @kevinrafferty9748 3 роки тому +2

      Absolutely. You'll see quite a bit of applications where this is acceptable. The tank has a Max temperature of 240 the max temp for a typical boiler is 200 but usually doesn't even exceed 180.

  • @benmen8699
    @benmen8699 9 місяців тому

    THE LEFT SIDE OF THE AIR PURGE SCOOP WHERE YOU CUT THE PIPE , IT JUST PUSHES IN TO THE SCOOP NO SOLDERING OR SEALING ?????

  • @kwacz
    @kwacz 2 роки тому +1

    tape or thread sealant never both

  • @faaulimalaesilia7524
    @faaulimalaesilia7524 Рік тому

    What is water heater installation

  • @NathanThePrezPretlow
    @NathanThePrezPretlow 5 років тому +3

    Why you did'nt install with another spirovent?

    • @tonymanero5544
      @tonymanero5544 3 роки тому

      The Prez The green Taco was probably what he had in the truck.

  • @josephmiller8938
    @josephmiller8938 2 роки тому

    What was wrong with The Purge tank

  • @gyver471
    @gyver471 5 років тому +2

    Is a spirovent better than an air scoop why switch for the air scoop?

    • @KJsComfortInc
      @KJsComfortInc  5 років тому +2

      Actually Spirovent is better than an airscoop. Spirovent had an issue with their older models that would cause them to corrode over time which would prevent you from servicing them. When this video was made I did not realize Spirovent had actually redesigned their product to prevent that from happening. We are working on a new video to show this.

    • @gyver471
      @gyver471 5 років тому

      K&J's Comfort Inc. I didn’t know thanks for letting me know lol

    • @richfjr1300
      @richfjr1300 4 роки тому +1

      @@gyver471 i actually have a spirovent in my upstairs baseboard, to remove the air when servicing (system had no way of bleeding air in the upstairs where it can get trapped).

  • @ardenbreitkreuz1409
    @ardenbreitkreuz1409 2 роки тому +1

    You said these have to be replaced often? Mine is 15 years or more. Is it possible to last that long?

    • @redpine8665
      @redpine8665 2 роки тому

      Mine is also 15 years old. They don't have to be routinely replaced.

  • @Ratman_Bejo
    @Ratman_Bejo 3 роки тому

    _Heating Boiler Air ScoopsBulk Air_ Separators & Air Purgers

  • @ivansucic3453
    @ivansucic3453 3 роки тому

    Could somebody explain to me why the pilot light of my heating boiler turns-off before reaching temperature set on aqua stat set at 180 degrees. The boiler has 3 gauge scales in one enclosure (rectangular to square shape) with lower one for temperature from 60-260 degrees, and upper scale with 2 sub-scales-one for ALTITUDE 0 (zero) true 115 and another one for pressure 0 (zero) true 50 PSI. This gauge DOES NOT HAVE any wires attached to it. When water temperature reaches about 165 degrees, the pressure reaches passed 30 PSI and gas valve shots down and at the same time shots the gas for pilot light. The heating system has 3 zone valves, all of them in open position (mechanically). Why does it shots down pilot light?

  • @anthonymonah7116
    @anthonymonah7116 4 місяці тому

    If you remove a spirovent and install an air scoop,that is going backwards.

  • @alexcicoria5863
    @alexcicoria5863 2 роки тому

    Hey all my radiators seem to be working except for two of them. I find this strange since it’s a circuit.

    • @kevinrafferty9748
      @kevinrafferty9748 2 роки тому

      Hi Alex, although it’s a circuit air gets trapped at the top of radiator or you could have what’s called mono flow tees in your system which are working improperly. I would have a service tech come over and take a look.

  • @mohawkmike142
    @mohawkmike142 2 роки тому

    LWCO and 10 psi ? Is that device a pressure stat or a LWCO? A LWCO looks for water and has no pressure function so I don't follow your comment on that.

  • @deh5860
    @deh5860 4 роки тому +2

    you cannot connect iron to copper, only to brass.

  • @jbrookes701
    @jbrookes701 2 роки тому

    You never showed how the left side of the perger was attached did you solder it

    • @gabbytaveras5650
      @gabbytaveras5650 Рік тому

      LMAO I was thinking the same thing I never seen it being soldered

    • @bobthebuilder201
      @bobthebuilder201 Рік тому

      He crimped it with the battery powered crimp tool.

  • @kwacz
    @kwacz 2 роки тому +1

    NO NO NO tape or dope NEVER both. I like to use the blue monster and then wipe excess off after threading it on. Never use both.

  • @jspinosa50
    @jspinosa50 3 роки тому +1

    I don't get why people don't put a shutoff valve between the expansion tank and the system. Makes it a lot easier.

    • @philipajarapoo7675
      @philipajarapoo7675 2 роки тому +2

      Or shut offs before and after circulator pumps and auto vents.

    • @jspinosa50
      @jspinosa50 2 роки тому

      @@philipajarapoo7675 Why didn't you put a shutoff valve between the expansion tank and the system?

  • @jackward9721
    @jackward9721 3 роки тому +2

    You capped off the boiler manufacturers built-in air scoop on top of the boiler. Strike two. And you didn't install a valve underneath the new air vent you just installed for easy replacement of the air vent which only last a few seasons. Be careful next time installing the expansion tank because you may crack the air scoop. If you over tighten.

  • @jackward9721
    @jackward9721 3 роки тому +4

    You removed the Spirovent which is a better product than than the antiquated air scoop. Why didn't you
    just replace the head on the Spirovent? The product has a 20 year warranty to the original owner. And you
    didn't install the air scoop with 18" of horizontal piping before it. Which makes your installation useless.
    I respectively disagree with your replacement of the Spirovent.

    • @dasani383
      @dasani383 3 роки тому

      I was watching this video after my spirovent 1-1/2 inch was replaced it was 20 years old. I live in canada its hard to find the spare parts to replace this and it seems like mine was not worth fixing by replacing the head. I've heard older versions are a lot harder to replace? ended up replacing with a Calefactio one by our plumber. $800 as the calefactio itself was worth $300. I like to save money, but not sure if I could of really saved a lot by replacing the head. If it had a 20 year warranty how could they verify the purchase? hard to keep a receipt after 20 years haha.

  • @mikev.1034
    @mikev.1034 3 роки тому

    👍👍

  • @anthonyspadafora1384
    @anthonyspadafora1384 Рік тому

    You replaced an air separator with an air scoop, you need 18 inches of pipe before it.

  • @fingo35
    @fingo35 2 роки тому

    Good video, but you should call the parts by its proper name no this, if I want to buy the part now I don't know what to ask for

    • @kevinrafferty9748
      @kevinrafferty9748 2 роки тому

      Thank you! It was one of our first videos so we learned a lot from it. Unfortunately I can’t change it now but our new ones we make I try to be more precise.

  • @lisaj7760
    @lisaj7760 2 роки тому +2

    Not helpful.
    Explain what
    "this, this, and this" is

  • @ryanp3721
    @ryanp3721 5 років тому

    The only thing I don’t like that you did is use pro-press. Just a personal issue I don’t trust them as much as sweat copper

    • @KJsComfortInc
      @KJsComfortInc  5 років тому

      I can respect that. I've seen the stress they can endure which is why I use them but there are cases we just can't use press so we sweat.

    • @ryanp3721
      @ryanp3721 5 років тому +1

      Yeah doesn’t help that the machine is expensive and the fittings are like 4x as expensive

    • @mifi5913
      @mifi5913 3 роки тому

      I always keep brass hose caps on truck for when drain fittings drip if not practical to change at that point.

  • @hammurds
    @hammurds 4 роки тому

    Why tape and pipe dope? I’ve heard horror stories about doing that

    • @KJsComfortInc
      @KJsComfortInc  4 роки тому

      When using copper fittings I find they don't leak using that method. The only time I've ever seen a fitting fail was for black iron. When you're using black iron or cast you should only use pipe dope.

    • @QnQoooo
      @QnQoooo 4 роки тому

      @@KJsComfortInc i do and i seen dope n tap on black pipe all the time, never see any issues. what is the problem of using dope n tape?

    • @kevinrafferty9748
      @kevinrafferty9748 4 роки тому

      @@QnQoooo I've had guys tell me they've used both on black iron with no issues. For me personally, I have come across a lot of failures due to using both on iron.

    • @QnQoooo
      @QnQoooo 4 роки тому

      Kevin Rafferty not tight enough?

    • @picklerix6162
      @picklerix6162 3 роки тому +1

      Steve Lav uses both tape and pipe dope on regular plumbing but he only uses pipe dope for gas piping. I have never had any issues using pipe dope by itself.