Boiler Basics: Part III - External Components

Поділитися
Вставка
  • Опубліковано 24 лис 2024

КОМЕНТАРІ • 210

  • @greg5830
    @greg5830 Рік тому +3

    This is one of the best videos I’ve seen yet explaining the external components. Thank you so much for sharing this. It has definitely helped me for school.

  • @jbauer2577
    @jbauer2577 9 років тому +14

    This was one of the best videos explaining all the external system parts of a forced hot water heat boiler. I had a plumber come in and "rework" my system - making it look very similar to this bc I had an issue with PSI going up to 60psi - yowza, so turned off boiler and had him come in. He did his rework, but... he never replaced the expansion tank - reused the old one, and 1.5 hrs after we turned system on, yep - back to 60psi again! I gave him a verbal lickin' and he came over straightaway to replace the expansion tank and even replaced the guage (triadometer?) while he was at it. Anywhoo, watching this video was great for understanding better how its all put together. Thanks for your educational info!

    • @SylvanTieger
      @SylvanTieger 6 років тому

      1- A hydronic boiler has a relief valve SET @30 PSI so how did you have 60 PSI?
      2- ASME / NBBI states a low pressure hot water boiler shall not exceed 160 PSI and or 250 DEG which I seriously doubt you have in your home
      3- Are you sure your so called plumber and you were not looking at the tri indicator gauge and mistook altitude for PSI?
      60 Feet would equal approximately 26.04 PSI

  • @bnjnmt
    @bnjnmt 11 років тому +4

    Great series - looking at an older home with boiler and hydronic baseboards but wasn't sure where to start for inspection and maintenance. Well done!

  • @chipshastid428
    @chipshastid428 5 років тому +13

    Mike , this is great. thanks for your efforts. Somebody called this "boring", I think I can guess his educational level.

  • @houston5627
    @houston5627 10 років тому

    EXCELLENT!!! Can't get any better illustrated. The well informed spokesman and the video production, WOULD HIRE BOTH!!!

    • @Nuro1992
      @Nuro1992 10 років тому

      How about a self motivated diligent newbie with a strong desire to learn?

  • @jeffreykubiak5126
    @jeffreykubiak5126 3 роки тому +2

    Thanks HVAC technician since 87 like part about expansion tanks .Learned about higher pressure on tanks above sea level!

  • @allen3050
    @allen3050 10 місяців тому +2

    Hello, I would like to kindly refer you to two authors on Hydronic heating circuits. Dan Holohan has written “Pumping Away” which refers to the most efficient side of the expansion tank the circulator should be on, and “Hydronic Radiant Heating, both excellent books. Another outstanding work is “ Modern Hydronic Heating” by a P.E. John Siegenthaler. I have noticed you have no pressure and temperature gauges to keep track of the temperature differential which should be kept around 15 degrees, supply vs return temperature, and circuit pressure which indicates circulator pressure above the circuit static pressure of 12 psi. Best Regards !

    • @tdiv1
      @tdiv1 9 місяців тому

      Are you a plumber?

  • @blackmanops3749
    @blackmanops3749 4 роки тому +4

    Thanks for the heads up on checking the expansion tank pressure before install.

  • @genuineimpulse9134
    @genuineimpulse9134 Рік тому

    Thank you for showing all parts. Like wire connecting and angling hints. After you had the valves opened, before turning it back on...Did you fill or top off the system before turning it back on? It says on the pumps can remove check valves for outdoor boiler....when would it be advisable to do that?

  • @paulpickard8327
    @paulpickard8327 5 місяців тому

    Really good explanation! Now can you do one on how to do all the related plumbing for a whole system? I need to replace several sections that are not currently connected!

  • @shimara1218
    @shimara1218 23 дні тому

    Can you diagram how you made the electrical connections between valves, thermostats and the relay? Will be very helpful. I tried to build similar systems

  • @peteolesen265
    @peteolesen265 2 роки тому +2

    Great Video. So here is my problem. The entire house is running hot. I have turned off the thermastats. It seems odd that all 3 zone valves have failed in some way.
    I will watch the other videos as well, but are their books and websites that help a diyer diagnose and solve these issues? I have done some copper pipe sweating in the past, so I may tackle this if I know what I am doing. Thanks very much

    • @genuineimpulse9134
      @genuineimpulse9134 Рік тому

      Are there lessons from however you solved that issue, that you could share? Did you tickle it out or did it = new pump. And or new pump and high temp reset button? Melted pipes in places? Gee can you tell how many times I've been left with little information to try my own problem solving, often involving expensive shipping.

    • @peteolesen265
      @peteolesen265 Рік тому

      @@genuineimpulse9134 I ended up calling a HVAC company and it was one valve that controlled most of the house had failed. It never would shut off. I have three zones in our house and this particular one covers most of the house. I hope that is helpful for you.

  • @davidsimpson8108
    @davidsimpson8108 9 років тому +3

    Nice comments on how a FHW system works. I went from a simple FHA type system at my old home to this one at my new home and never knew how the expansion tank worked. Now I know 12psi. Now I won't feel like an idiot when I call my furnace technician for service.

    • @peterricci1051
      @peterricci1051 7 років тому

      A furnace doesn't have an expansion tank. But, a boiler does! So, you are still an idiot!

    • @bikeoffrd9555
      @bikeoffrd9555 7 років тому

      Peter, Dave was talking about his new system....so you are looking like the idiot.

    • @peterricci1051
      @peterricci1051 7 років тому

      Well.......then why is he calling his FURNACE technician for his NEW system then?????

    • @bikeoffrd9555
      @bikeoffrd9555 7 років тому +2

      Dave called his new system a furnace by mistake.

    • @JohnDoe_88
      @JohnDoe_88 2 роки тому +1

      @@peterricci1051 Peter could use a heating system because he's cold blooded

  • @robertsherrick4081
    @robertsherrick4081 7 місяців тому

    Yup, exactly what I was looking for re: expansion tank issues. Thanks!

  • @ironwill04
    @ironwill04 5 років тому +2

    Excellent video! So helpful thank you! Is there a good explanation of how to change your expansion tank? I have lots of water coming out of my Schrader valve. I am new to water boilers and looking to understand how to maintain it

  • @Taqqiyastar
    @Taqqiyastar 11 років тому +1

    If the expansion vessel/Tank Pressure drops as you have said then its need to be re-charged means pumping air pressure back in to the required psi using a air pump depending with the model, size and manufactures instruction

  • @tk032009
    @tk032009 11 років тому +16

    We should really be promoting the circulator pumping away from the expansion tank as the pump manufacture have been promoting since the late 50's.

  • @impsquared
    @impsquared 3 роки тому +1

    Thanks for this video. You answer everything I need to know about the expansion tank on my gas boiler system!

  • @TransTurbine
    @TransTurbine 4 роки тому +1

    Hey Brother I am not sure if you will see this comment, yet I have a question you might have an answer to. I have a taco feed valve which fills my boiler. I know this allows water to enter the boiler if there is a pressure drop. However does this valve also act as a check valve to keep hot water from bleeding back into the cold side?
    I have a peerless boiler and the tankless coil went bad. I first noticed a problem when my cold water pipes were becoming hot. I then removed the tankless coil from the boiler and just put a blank cover on. However now when I start the system, my cold water is now hot. Seems to me that the taco feed valve should act as a check valve to keep this from happening, yet I might not be correct.

  • @Shahrdad
    @Shahrdad 3 роки тому +2

    Why is the air-separator placed right after an elbow? Airscoops demand a minimum of 18" of straight pipe before the scoop.

    • @TordeanRivera
      @TordeanRivera 9 місяців тому +1

      Also, why is the cold water supply on the supply and not the return

  • @bobo11112222
    @bobo11112222 Рік тому +1

    Expansion tank should be piped point of no pressure change.
    Circulator need to be piped after the expansion tank on suppy, boiler out. Those air scoop (taco manual says 18” minimum on the inlet after 90°elbow). Too little space use spiral vent.

  • @shoehorny6844
    @shoehorny6844 4 роки тому

    Great information! Shouldn't you also have isolation valves on either side of that pressure regulator?

  • @VegasJPH
    @VegasJPH 10 років тому

    Good series of videos. I'm looking at a house that has a boiler furnace & during the home inspection the Taco cartridge circulator (model 007-F5) was making some loud noises. Loud enough the inspector commented to me that it should be pretty quiet & not that loud.
    I didn't see a cartridge circulator here... I did see the pressure value was a Taco brand. But where would the Taco 007-F5 be in regards to this setup?

  • @k.b.392
    @k.b.392 11 місяців тому

    HI. When changing a zone valve does the "pipe" part have to be changed, too??? I have 2 zones. I had to replace one zone valve 2 years ago. Yesterday I had to replace the other one. ONLY the mechanism in the box & wires were changed both times. Zone valves were 23 (2021) -25 (2023) years old.

  • @marcosmatos7004
    @marcosmatos7004 4 роки тому

    Clearly explained & very informative video. I labeled every component you mentioned with a Sharpie! THANK YOU!!!

  • @Deltro61
    @Deltro61 9 років тому +1

    question: I have what I believe is a check valve leaking to my boiler. Is it okay to turn the water off to the boiler for 24 hours until I can get it replaced? I'm guessing that the requirements for freshwater to the boiler are minimum since it's a closed loop system. My knowledge of boilers is pretty limited, so appreciate any input. Thanks

  • @michaelmaker8169
    @michaelmaker8169 2 роки тому +2

    How do I check pressure in boiler when gauge is broken?

    • @generatornoiseheavy_a6546
      @generatornoiseheavy_a6546 Місяць тому

      Buy a screw on gauge and connect it to a drain cock and open it.

    • @michaelmaker8169
      @michaelmaker8169 Місяць тому

      @@generatornoiseheavy_a6546 I'm looking for water pressure in the boiler. It helps it from going dry which will crack the boiler.

  • @dirtywaterlove
    @dirtywaterlove 6 років тому +1

    I'm curious why there are no purging stations on the return. Also, backflow prevention is very important, especially if it's your personal well.

  • @goesintite
    @goesintite 10 років тому

    How does the "air scoop" work and how tight should that little valve be?
    Also, a friend has a hot water boiler furnace and she has to take a quick shower. Any suggestions for resetting the upper and/or lower setttings etc?
    Great video, by the way!
    Thanks!
    Big Mike

    • @bonnielaverty5313
      @bonnielaverty5313 8 років тому

      The scoop removes bubbles that are suspended in the water. Air rises to the top of the pipe as it runs horizontally, the scoop( which is always mounted horizontally) has a big bulge going up, which allows some of the bubbles to rise up out of the water stream and be captured by the auto air vent.

  • @renrut0
    @renrut0 4 роки тому +2

    Now I had a model 30 expansion tank(large cast iron radiators/a lot of water in my current system) and my relief valve kept releasing. I read and purchased/installed a model 60 tank to be able to handle the amount of water(when heated) and the difference is night and day. My radiators heat more evenly now more than ever and my pressure is more constant. Just saying don't skip out on the people with large volumes of water in their heating system because not everyone has copper pipes mine are 2" cast iron in my basement. A model 30 works great with now standard volumes of water but they may need a larger tank for larger volume of water in their system...if they have an older home like I do.

    • @francopedro4910
      @francopedro4910 3 роки тому

      You all probably dont give a shit but does someone know a method to log back into an instagram account??
      I was stupid forgot the password. I appreciate any tricks you can offer me!

    • @damaridecker2139
      @damaridecker2139 3 роки тому

      @Franco Pedro instablaster :)

    • @francopedro4910
      @francopedro4910 3 роки тому

      @Damari Decker i really appreciate your reply. I got to the site on google and I'm in the hacking process atm.
      Takes a while so I will reply here later when my account password hopefully is recovered.

    • @francopedro4910
      @francopedro4910 3 роки тому

      @Damari Decker it did the trick and I finally got access to my account again. I'm so happy!
      Thanks so much you saved my ass :D

    • @damaridecker2139
      @damaridecker2139 3 роки тому

      @Franco Pedro No problem :D

  • @Kobe29261
    @Kobe29261 6 років тому

    I have a shut-off in-line with the pressure regulator, should this be open when in operation? I bled the system and am unsure whether it was open or not. The way I understood it - this is what allows water into the system if pressure is outside the ideal range so I'll expect it to remain open when the system is in operation?

  • @alekjuskevice
    @alekjuskevice 3 роки тому

    Thank you for this, it was well explained and comprehensive for this type of boiler.

  • @OmeHi5
    @OmeHi5 8 років тому +1

    hello! I just bought a house and there is a boiler in the basement. That's all fine and good but I noticed that the water line that runs to the drinking water for my refrigerator is connected to the water line of the expansion tank. There is a pipe in between the expansion tank and the air scoop....my fridge water is connected to that. Is that a bad thing? I hope someone out there can help. I really would like to know so if it's bad I can make sure the kids don't drink from it

  • @eddychehade
    @eddychehade 5 років тому +1

    How do you set the low and high temperatures on the zone valves?

  • @oscar27ization
    @oscar27ization 2 роки тому

    Best video ever

  • @nicsye12
    @nicsye12 12 років тому +4

    this was very well done and informative, thank you!

  • @michaelpoczynek
    @michaelpoczynek 8 місяців тому

    Thank you. Interesting and great information. 😀

  • @77costa77
    @77costa77 2 роки тому

    Are the zone valves not supposed to be on the supply lines?

  • @johnal4560
    @johnal4560 2 роки тому

    Hi i recently did service to my water floor heating radiant I changed the expansion tank the pressure vale changed the Honeywell zones the zones are calling and the pressure gauge stays just 2 line above the 20 and staying there and i did flashed the water from all zone lots of dark water came out and i left it to open tell water color got back to normal but the issue i have is the first floor which got 2 zone both zone got warmed but the upstairs only get to 10 degree does not matter if i leave the tramontane all the way to the end or levee it on 20 so what cold be wrong what do u suggest please Thanks

  • @missdhara6434
    @missdhara6434 Рік тому

    Can someone please help? I installed a new gas bolier recently. But for some reason the boiler is running without reading the thermostat. Is this a faulty wiring or something to do with the boiler installation? The thermostat is getting power, it reads the time and measures the temperature in the room, but it doesnt regulate the house temperature set on the thermostat with the boiler . Its set at 70 but the house temp is 90! Is this a wire burnt out or is it a faulty installation?

  • @hvacrefrigeration5204
    @hvacrefrigeration5204 3 роки тому

    Very helpful video, and thank you so much for explanatory of it basic information to advance of system👍

  • @AskTheCarExperts
    @AskTheCarExperts 2 роки тому

    Great info!

  • @williysforever
    @williysforever 11 років тому +1

    excellent video very helful-presenter uses simple language easy to understand.

  • @kkovler1
    @kkovler1 4 роки тому

    If water comes out of the taco relief valve only as the system cools off, does this mean the valve is bad and should be replaced?

  • @Almanleatherco
    @Almanleatherco 4 дні тому

    Why the we can heard a hammer sound like a kick, when we shut the thermostat the thermostat sends the signal to shut to the zone valve and then the big kick hits?

  • @cbgreely
    @cbgreely 4 роки тому

    Excellent explanation!

  • @Melvin1221
    @Melvin1221 12 років тому

    this pat and the previous parts of this video is informative. Thanks for posting and sharing of your knowledge.

  • @EnjoyCalculus
    @EnjoyCalculus 3 роки тому +1

    Why is the flue pipe touching the expansion tank? not good

  • @johnnyjax6444
    @johnnyjax6444 3 роки тому

    I have one main question on how we can control the water temperature mine is piping hot , I want to reduce the temperature but the issue is we do not have a external control device to control the water heat , one technician said the controller is inside the burner, is there any device that we can buy and control this out side , basically what I want during summer I want the water to be much mild so I can use for shower and winter time make the temp high, so I can save some fuel, my hot water I use both for my hot water and heater since I do not have a hot water tank does any one can help on this question ?

  • @gregorydechiara6159
    @gregorydechiara6159 Рік тому

    The boiler feed valve should be set to where?

  • @Kobe29261
    @Kobe29261 8 років тому

    My automatic air vent (in this video directly above the air scoop as in mine) is leaking badly; the replacement is also leaking. the bottom of my expansion tank sounds markedly different from the top i.e hollow, I take this to mean it doesn't have a leak. What else am I missing?

  • @footballfans3159
    @footballfans3159 4 роки тому +1

    Thanks a lot now I understand my heating system.

  • @ZuffaLtdDanaWhite
    @ZuffaLtdDanaWhite 11 років тому

    What if a home user keeps depressing the shrader valve in the Expansion Tank.. suddenly 2 years later all the air has been released from the expansion tank. Then what happens? Are they able to be pressurized again, or a new one needs to be installed?

  • @tazzman2288
    @tazzman2288 10 років тому +1

    Great stuff. Truly a professional thx for sharing

  • @TSGiants56
    @TSGiants56 6 років тому +1

    Very well done! Tech support for Taco INC.

  • @meproyecto4ever
    @meproyecto4ever 8 років тому +1

    hi mike
    my boiler is liking water.
    any way to fix that
    thaks

  • @sharonwaterbury4978
    @sharonwaterbury4978 3 роки тому

    when I turn on zone one zone two heats up, when I turn on zone two zone one heats up, is it the wiring?

  • @stephenjohnson1734
    @stephenjohnson1734 8 років тому +1

    First, great video, very helpful. But I noticed that the expansion tank in this video was installed on the outbound/supply (hot water leaving the furnace). Is that required? My home has a boiler with a very old style expansion tank. I want to get it replaced. But it's installed on the return side (cool). Was that improperly installed or is it an option to place on either side? Thanks

    • @joeurban3724
      @joeurban3724 7 років тому

      Mine is also installed on the intake side, which does not make sense to me. I wonder if I should have a plumber change it.

  • @btbfree
    @btbfree 8 років тому

    Hi Mike, thank you for sharing. I have a Crown boiler, but the guy didn't install the drain valve. Do you recommend to bleed the boiler through the manifold drain valve located below the pump. The boiler was installed in 2003, so go figure, I haven't bled the system in 13 years. Please help me with this one. Thank you in advance. Happy Halloween!

  • @street35z
    @street35z 10 років тому

    Got any video's about hot water boilers that are oil fired?
    I have a Burnham v7 boiler with beckett burner that has pressure gauge and temp gauge in one on front that heats up to 210 to 220 and pressure goes from 12psi cold to 20 and sometimes 25 psi when hot. The high and low limit settings for the temp inside the boiler I had to set at 180 high and 160 low for it to stop at 210 to 220 on the temp gauge on front.I put the high limit at 200 and it wanted to go over 220 and then was blowing out steam on overflow and the excess air valve on top of the pressure tank.
    Maybe need to change the part that has high and low limit on it ?

    • @bigpardner
      @bigpardner 9 років тому

      +street35z I don't know as much as some of these guys commenting here so don't put too much stock in what I say. If your cold to hot pressure varies that much I can't think of what it would be other than a faulty or maladjusted expansion tank. If it were me I might try getting the water pressure off the tank and checking the bladder pressure with an air gauge. Maybe when your boiler gets too hot it is the temperature sensing system of the aquastat, probe and/or aquastat, so why not simply lower the high limit setting until it doesn't blow off steam? I believe, at least on mine, the aquastat temp probe and temperature gauge probe are two different devices and in my case are in two completely different locations with the aquastat probe being surrounded by the HW coil. I suspect this makes it slower to respond to temp changes inside the boiler, both increasing and decreasing, compared to the temp gauge.

  • @LTVoyager
    @LTVoyager 7 років тому +1

    Pretty good basic explanations, but the example system is poorly designed. The expansion tank sets the PONPC (point of no pressure change). The circulator should "pump" away from the PONPC. Otherwise you lower the pressure well below the static pressure (whatever the head capability is for the circulator) which risks introducing air into the system at air eliminators, particular in a multi-story home.

  • @jimu57
    @jimu57 10 років тому

    Regarding the pressure tank, isnt the pressure set at 12 psia and not psig?

  • @landongall2080
    @landongall2080 5 років тому

    Great video!!!

  • @sportsworld1892
    @sportsworld1892 5 років тому

    Thanks, verry clear and helpful explanation

  • @spidermcgavenport8767
    @spidermcgavenport8767 8 років тому

    Okay I have a hydronic oil boiler, those float valves bleed oxygenated water so they bleed out every time it cycles so your getting water over every piece of equipment below it so my suggestion would be better put a drain or a sponge on it cause it could drain all over your power control unit. Making rust and corrosion a real problem! please place it in a different location if possible that's the float valves..

  • @j.qingshui9608
    @j.qingshui9608 3 роки тому

    How to replace the expansion tank ? thanks.

  • @fulana3456
    @fulana3456 10 років тому +1

    how can i know if the circulator or zone valve still works or not?

    • @bonnielaverty5313
      @bonnielaverty5313 8 років тому

      You might be able to manually open the zone valve- if you hear a rush of water through at that point the pump is working fine.

  • @taozhang5522
    @taozhang5522 4 роки тому

    Thanks and learned a lot

  • @cardo1111
    @cardo1111 6 років тому +1

    Very informative vid. I wish that I knew how to install one myself most contractors in my area charge over $3,000. USD for materials and labor plus the cost of the boiler.

    • @Jason-wc3fh
      @Jason-wc3fh 6 років тому +1

      What a rip off!!! They should just show up with all the parts and do it all for free since you're so special!!!

    • @cardo1111
      @cardo1111 6 років тому

      Jason You’re either a plumber or a comedian. You missed my point which was it is a valuable skill to have, someone with the know how can do this in about 5 hours or so that comes out to about $500 per hour in my area. Was I wrong?

    • @Jason-wc3fh
      @Jason-wc3fh 6 років тому

      @@cardo1111 A comedian more so then a plumber... Where I am our plumbers aren't allowed working on these. I'm an HVAC tech and there's no hydronic/boiler system I can even purchase all the parts for at $3,000 USD.

    • @cardo1111
      @cardo1111 6 років тому +1

      Jason Understood. In this area not much regulation on these, no permits required on replacement boilers only if adding one for the first time. Most people are just replacing their existing low efficiency units with new low efficiency units. Labor accounts for about 60% of the cost. Mostly plumbers are installing them but there are some HVAC techs that do them as well. There were some high efficiency incentives a while back but the condensing boilers are a hard sell for those on a budget as they can take many years to offset their higher cost and they are supposedly less reliable and require more costly repairs when needed. I am not a tradesman just speaking from what I have read and my conversations with local pros. I am sure as a pro you have your opinions on them and real world experience installing and maintaining them.

    • @russor22
      @russor22 5 років тому

      cardo youre not paying a plumber for his time...your paying a plumber for his experience...especially w a heating system...do you try and justify what an anesthesiologist should be paid for time when u go for surgery?

  • @jamesyoson1280
    @jamesyoson1280 4 роки тому

    Very helpful . Thanks

  • @nachshonkroizer3750
    @nachshonkroizer3750 2 роки тому

    Amazing 👏

  • @chrisc.1057
    @chrisc.1057 9 років тому +1

    can he tell me how he had those zone valves WIRED in? I could see on wire to the 24VLTS TRANSFORMER but where did the other lead

    • @mrbig4532
      @mrbig4532 7 років тому

      Chris C. To the thermostat.

  • @ckpat50
    @ckpat50 6 років тому

    Didn't see any isolation valves to easily replace anything that fails. Also if the relief valve is piped to an unheated crawlspace any leak could potentially freeze in the discharge pipe creating an explosion hazard

    • @Jason-wc3fh
      @Jason-wc3fh 6 років тому

      no pressure relief pipe is supposed to be "piped" directly into anything. It's supposed to be piped close to a floor drain, into an open pipe, etc... But it should end by being open to the atmosphere.

  • @KC-zp3mx
    @KC-zp3mx 11 років тому

    Hi, Do you know what would be the problem if the pressure goes above 20, e.g. 25 and at about 22 to 23 PSI, the psi becoming unstable, and makes some jumping/kicking sounds. Do you know what might be the problem?
    And in addition to that, when it goes to 22/23 psi, water starts dripping from high pressure relieve valve.
    NOTE: i just replaced the expansion tank a week ago.
    Thanks.

    • @ElloMyNameIsWalton
      @ElloMyNameIsWalton 10 років тому

      First, check the air pressure in the expansion tank. Please watch and listen to the video between 5:30 and 8:16 carefully and you may be able to figure out what going on. Good luck. I doubt it's a defective expansion tank, but it is possible.

    • @KC-zp3mx
      @KC-zp3mx 10 років тому

      Thanks for the comment. How do you check the air pressure in the expansion tank? Thanks.

  • @larryclark9380
    @larryclark9380 6 років тому

    Useful video. Thank you.

  • @bjar99
    @bjar99 10 років тому +1

    Great Video.... Very informative
    Thanks

  • @jessemayra
    @jessemayra 10 років тому

    Excellent vid

  • @catmouseize
    @catmouseize 4 роки тому

    The atmospheric pressure is 14.6 psi, how can you set the regulator at 12 psi? The water may never be able to be injected into the system?

    • @leonidas91
      @leonidas91 3 роки тому

      14.6 PSIA Is less then 12PSIG

    • @smidtwarner
      @smidtwarner 3 роки тому +1

      Yes, 14.6 PSI is due to the atmosphere; but the 12 psi is relative to the ambient pressure-not absolute pressure. In other words, the pressure in hydronic system is 12 psi above atmospheric pressure.

  • @ironwill04
    @ironwill04 5 років тому

    Is there a certain kind of expanaion tank you recommend? My boiler has one that the paint is peeling off and there is no label.
    Also do you have a video on how to stop the water flow to change it?

    • @stifflers69mom1
      @stifflers69mom1 5 років тому +1

      ironwill04 call your local HVAC guy he will have everything you need

    • @blackmanops3749
      @blackmanops3749 4 роки тому

      Home depot carries them. Amtrol or Extrol are the most common where I live. The important part is to get a big enough one. If in doubt get an oversized one. I also suggest plumbing a valve on the inlet so that future replacements are easy (no need to drain the system).

  • @StephonBrooks
    @StephonBrooks 7 місяців тому

    WHO TYPICALLY DOES REPAIR OF LEAKS FOR THIS SYSTEM A PLUMBER OR HVAC

  • @jarrittwagner2268
    @jarrittwagner2268 4 роки тому

    does the expansion tank need to be upright or can you install it upside down (if that makes sense)

    • @smidtwarner
      @smidtwarner 3 роки тому +1

      I am learning as much as I can so I can install my own hydronic heating for my house & shop. From what I have learned, the expansion tank should have the port up so air cannot be trapped in the expansion tank.

  • @dowra691
    @dowra691 5 років тому +1

    i NEED TO KNOW HOW TO LOWER THE TEMPERATURE FOR THE WATER THAT GOES TO THE SHOWER

    • @readysetsleep
      @readysetsleep 3 роки тому

      Wrong video, you need to look up water heater, this is a heating boiler system.

  • @danielsteele7544
    @danielsteele7544 7 років тому

    U didn't talk about the auto damper on the stack.

  • @ldr4278
    @ldr4278 5 років тому

    Excellent

  • @reddog9401
    @reddog9401 7 років тому

    at the bottom of my zone valve I am dripping water.what is causing It? how do I stop it.thanks

    • @wingerrwingerr4989
      @wingerrwingerr4989 7 років тому

      There's an o ring seal that should block the water from leaking out the valve housing, if you see it dripping from the edge of the plate. Mine looked like someone reworked it before and put the wrong size in there and it got split, and I tried to get a replacement but no one sells them, so I reused it successfully after trimming it to the diameter of the recess.
      Honeywell prefers you buy a new zone valve than just an o-ring, better for business.

  • @louiscorrales5410
    @louiscorrales5410 8 років тому

    Thanks you so much for your valuable information....

  • @niayuq
    @niayuq 6 років тому

    Where the house water enters, isnt that after the boiler going toward the baseboards. Mixing the cold and hot water? This is how my boiler is plumbed. Spent $800 on a boiler man and he noted this isnt how it is supposed to be plumbed. After he was done and I still have no heat.

    • @kevinc6805
      @kevinc6805 5 років тому

      I usually install the water supply on the return side of the boiler so that cold water won`t mix with the hot going out. That being said, it is a closed system and fresh water will rarely be injected so it doesnt really matter. Sounds like you have other issues going on.

  • @bobbydigital8
    @bobbydigital8 11 років тому

    Excellent info

  • @dougmclaughlin6991
    @dougmclaughlin6991 4 роки тому

    Thank you!!!

  • @parveensharma1883
    @parveensharma1883 5 років тому

    Good video

  • @jonathangarmany6954
    @jonathangarmany6954 7 років тому +1

    Wouldn't the pressure be lower at a higher altitude?

    • @smidtwarner
      @smidtwarner 3 роки тому

      I don’t think so. It is a closed loop system so it should not be affected by less atmospheric pressure at higher altitudes. The loop and expansion tank are charged to 12 psi above what ever the ambient atmospheric pressure is. In other words, it is 12 psig.

  • @djianmurphy
    @djianmurphy 9 років тому +3

    Expansion vessels should be on the return to give the diafram longer life as it's cooler than the flow, zone values should on the flow to stop heat creeping when zones are off and as for that automatic air vent its not doing much down there as air will naturally go to the highest point which is not where its at, looks like its all back ways to me just saying

    • @djianmurphy
      @djianmurphy 9 років тому

      ***** if you put a zv on the return going into the cylinder the heat will creep in the flow and heat the coil this wont happen as bad if you put it on the flow, it wont creep up the return as its colder as for the aav highest point is best, as for were to put things on a heating system you can put them nearly any were and it will still work its where is best to put them to keep up good practice

    • @smidtwarner
      @smidtwarner 3 роки тому

      No, expansion tanks need to be near the source of the expansion, thus on the supply side. If on the return side the tank is too far away from the source of the expansion to be effective.

  • @josephvargas9707
    @josephvargas9707 7 років тому

    if anyone cus answer me this question IL apreciate .......who wires this zones or relays or manifolds.??.. the plumber or the electrician ?

  • @is5695
    @is5695 6 років тому

    Wow the air scoop is installed incorrectly.

  • @786otto
    @786otto 6 років тому

    Not sure about that expansion tank right on the flue pipe, and pump away means pump away from the expansion tank.

    • @luke3807
      @luke3807 6 років тому

      Why?

    • @smidtwarner
      @smidtwarner 3 роки тому +1

      I could answer this better with an accompanying diagram; but I will try with words only. First, you have to remember that the pressure on the air side of the expansion tank is 12psi. This is measured when there is no water in the pipes. When the pipes are fully charged, there is 12 psi in the pipes. This means the blatter in the expansion tank (ET) is exactly in the middle since there is 12 psi pressing from both sides. This is key to remember.
      For conversation sake, let’s say that the pump generates 20 psi of pressure that pushes the water thru the pipes. When the pump is not running, the pressure at the pump outlet is zero. In fact, the pressure is zero at all locations in the circulation loop. Don’t get confused here. The pipes are charged to 12psi; but that is relative to the pressure outside the pipes. But now I am discussing pressure differences between different points inside the circulation loop. When the pump is OFF, the water does not move because there are zero pressures differences through the loop.
      When the pump is running there is 20 psi at the outlet. At the pump inlet there is a negative pressure because it is drawing or sucking the water in. Let’s say pump inlet pressure is -2psi. So the total pressure difference between outlet and inlet is 22psi. The pressure is 20 psi at the outlet and keeps dropping as it goes around the loop until it reaches 0 psi and then due to pump suction drops to -2. The point in the loop where it is 0psi is a few inches before the pump inlet. Or if the pipe is straight with few elbows, it may be 0psi a few feet before the inlet. You want the ET connected as close to the 0psi location as possible. If the ET is near the pump outlet, then there will be 20 additional psi pressing on the ET blatter this reducing the effectiveness of the ET. When the ET is located at the 0 psi location, the blatter will be in it’s “neutral” position which is at its most effective capacity position.

    • @786otto
      @786otto 3 роки тому

      @@smidtwarner Thank you for reply.

    • @richardhoner7842
      @richardhoner7842 3 роки тому

      @@smidtwarner I thought it was a circulator not a pump. Isn't there a difference?

  • @SylvanTieger
    @SylvanTieger 6 років тому

    How can the "expert" called the circulator a pump Why didn't he explain why the automatic feeder is "set" to 12 -15 PSI
    When setting the automatic feeder a skilled mackinac will look at the static pressure (no flow) then calculate how to set the auto feeder properly
    Suppose the highest radiator /copper fin is 30 feet above the boiler
    You can simply take 30 feet times .424 = 13 PSI so we know we need a fudge factor to make sure we have positive pressure in the system so we increase the auto feeder to 15 PSI
    To prove the 13 PSI will elevate water that high we take 2.31 X 13 = 30 feet
    Adding in 2 PSI will aid when they need bleed the system

  • @bettysmith7045
    @bettysmith7045 5 років тому

    I was hoping you were going to tell us how to change the water temperature.

    • @stifflers69mom1
      @stifflers69mom1 5 років тому

      Betty Smith why would you wanna do that?

    • @bettysmith7045
      @bettysmith7045 5 років тому

      @@stifflers69mom1 because its coming out of the faucet at 147 degrees which is way to hot, and unnecessary, so I was hoping to lower it.

    • @stifflers69mom1
      @stifflers69mom1 5 років тому +2

      Betty Smith ok I got ya ,that’s two entirely separate things .... your boiler water should be around 180 degrees Fahrenheit always .....your DWH (Domestic hot water) should have its own high limit cut off somewhere near your tank ....I would say next time you have your Sevice Guy out for seasonal maintenance have him go over your system with you so you can better understand because a lot of these systems are unique in every house

  • @mjcampm247
    @mjcampm247 10 років тому

    great stuff thanks

  • @Kab695
    @Kab695 9 років тому

    My Zone Valves have three settings: in the middle it says, Manual, and the lever can slide along this slot. But on both ends of this slot are two locking positions: Auto and Open. For normal thermostat control, should my these zone valves be set on manual or Auto? Right now they are on manual, and ...I just don't know.

  • @milkmanpeter
    @milkmanpeter 6 років тому +5

    I don't think it's good to have expansion tank next to flue