Boiler Auto Vent Replacement

Поділитися
Вставка
  • Опубліковано 5 вер 2024
  • www.amazon.com/shop/miheatingguy
    NU CALGON 4774-0 Coil Gun Sprayer With Quick Connect Hose Nozzle
    amzn.to/39PxGya
    Nu-Calgon 4291-08 Nu-Brite
    amzn.to/3u6yN3x
    Milwaukee 2131-20 M18 ROCKET Dual Power Tower Light
    amzn.to/3pe2hYH
    Milwaukee M12 Surge Hydraulic Driver Kit 2551-22
    amzn.to/3n5offb
    Makita E-01563 Impact XPS 3 Pc. 6" Magnetic Nut setter Set
    amzn.to/2JdAcku
    Milwaukee 48-22-6330 Tongue and Groove Pliers Set
    amzn.to/3kfch0R
    GoPro Hero 8 Black Action Camera with Accessory Bundle
    amzn.to/34AGamf
    Veto Pro Pac Tech XL Tool Bag
    amzn.to/2U1QqPF
    OLIGHT Bundle H2R LED Headlamp, 2300 Lumens Rechargeable Flashlight
    amzn.to/370rGiq
    Amprobe AMP-320 Clamp Meter
    amzn.to/2GNxUHe
    Fluke 117 Electricians True RMS Multimeter
    amzn.to/3iFZP9t
    Milwaukee 2364-20 M12 Rover
    amzn.to/2HNvitK
    Milwaukee Rocket light 2132-20
    amzn.to/341OTPm
    #MIHeatingGuy
    #MichiganHeatingGuy

КОМЕНТАРІ • 17

  • @danobrien3109
    @danobrien3109 Рік тому +2

    Nice to see the simple ones too Joe. Thanks👍👍🇨🇦

  • @Yawwee
    @Yawwee Рік тому +3

    Nice to get an Easy 😄Peasy job !!! That install sure looked 👀pretty🌹 nice, all quality 🛠workmanship 🏆there !!! Looks like it was done🕒 yesterday !!! On to the next 🚐one !!!!!

  • @joeyf504327
    @joeyf504327 Рік тому +3

    2 story house turned into a rental? I'm surprised anyone still install air scoops given how awesome micro-bubblers work.

  • @WoodsboroDriftor
    @WoodsboroDriftor Рік тому +1

    love when the work comes together good

  • @williamserver4332
    @williamserver4332 Рік тому +2

    Great video

  • @skaizun
    @skaizun 8 місяців тому +1

    NEVER turn ANYthing connected to a pipe without attaching something to keep the torque from twisting or breaking adjacent piping! (i.e., another wrench on the closest, unmoveable, pipe, preferably wrapped in a small towel to prevent the anti-torque - - if you will - - wrench from damaging it). If the pipe is cool enough, you can hold it by hand, but, people can over-torque the pipe with their hand, as well!

  • @leesunlung
    @leesunlung Рік тому +1

    I realize that you shut the vent valve at the end. Should you suppose to keep that valve open?

  • @rufiorufioo
    @rufiorufioo 5 місяців тому +1

    Would these vents fall under a home warranty? I have two that need changed with a type 30 thermal tank needing changed. I could do this myself cause I can isolate the inlet and water return to boiler.. Just of course would like to have a professional do it if possible. Also the air vents one is 150 psi and other is type 67 35 psi ? Is that normal?

  • @altyndom7039
    @altyndom7039 Рік тому +1

    Resemblance of similar jobs is striking you might as well be from my company.

  • @lukehodgson5222
    @lukehodgson5222 Рік тому +1

    I have an auto vent on my boiler system too. How do you know the vent needs changed? I get some gurgling in my baseboards when it's running. Thanks. Keep the boiler vids coming!

    • @caru3257
      @caru3257 Рік тому +1

      You may need a new reducing valve and the auto vent gets replaced if it is leaking.

    • @jameslang9170
      @jameslang9170 Рік тому

      Those little air vents do little to nothing for air elimination but leak. You probably have air in the line.

    • @skaizun
      @skaizun 8 місяців тому

      If you see a lot of lime or calcium deposits on the air vent (typically, made by Taco), then it's possible that it needs to be changed. FWIW, the first time I changed my air vent was 20 years after the boiler was installed, professionally. The second time was 5 years after that. The third, and most recent, time was 3 years later! Clearly, something drastic has changed in the manufacturing process and/or the materials used that it no longer lasts as long as it used to. For the most part, just clean the outside of the air vent with a stiff metal brush that can be found in most dollar stores' auto or tools section (it, usually, comes in a pack of 3 or 6 similar brushes of different sizes and stiffnesses). The cleaned vent doesn't have to be perfectly shiny; just enough to get rid of the gunk! (be very careful when touching the metal parts and nearby pipes, as they may be hot!) When done, untwist the metal cap (looks like a car tire cap; it may be lightly stuck on due to rust or calcium) and GENTLY stick a pin in the hole no more than an inch or so down to help clear it; then, put the cap back on, stopping when the cap won't go any further, then unscrew it one-quarter turn to allow air to escape. Don't be surprised if you need to do this multiple times a year! Cheaper than replacing it, right? However, if you find a puddle of water beneath the air vent (I have a piece of plastic and aluminum foil to direct any overflow into a small, plastic, bowl, on the floor to catch such), then the overflow isn't being "burned off" (evaporated) by the boiler's heat, which means it is flowing too much or too often, and should be replaced. Although it is easy to do, if you are not mechanically inclined, the damage you can do will cost far more than the approx $15 of the air vent, never mind the potential for scalding yourself, so, a $150 professional plumber visit may be more prudent.
      Long, but, fast and highly detailed, explanation of these air vents,
      including a cut-away demonstration of its inner workings:
      ua-cam.com/video/Ogw83f-Tbvg/v-deo.html

  • @Ron-yf9jl
    @Ron-yf9jl 6 місяців тому +1

    Is the the boiler vent cap suppose to be tight

    • @MiHeatingGuy
      @MiHeatingGuy  6 місяців тому +1

      no

    • @Ron-yf9jl
      @Ron-yf9jl 6 місяців тому +1

      I was wondering because my brass cap has a vent hole in it.

  • @mikev.1034
    @mikev.1034 Рік тому +1

    👍👍