Це відео не доступне.
Перепрошуємо.

Padstone Design Example for Beam Forming an Opening - Structural Engineering

Поділитися
Вставка
  • Опубліковано 15 сер 2024
  • In this video I will go through an example on how to design a padstone for when the beam is spanning parallel to the wall when you are forming an opening in a wall.
    Padstone design Part 1 - • Bearing Design for Ste...
    Foundation design with stress example - • Foundation Design Exam...
    #structuralengineering #padstonedesign #wallopeningsinmasonry
    Show your support or if you want mentoring:
    / everydaydazz
    I create a lot of my videos, engineer sketches and notes on my iPad and if you own an iPad and are looking for a matt screen protector, I have been using Paperlike screen protectors for 3 years now and they are really good. Feel free to check it out - paperlike.com/...
    -----------------------
    Purchases made from store links may give me some money.
    (It doesn’t cost you extra, so please buy everything)
    Structural Engineering Books I recommend:
    Structural Engineer’s Pocket Book - amzn.to/3no7taL
    Reinforced Concrete Design to EC2 - amzn.to/2Xlx75C
    Steel Designers Manual - amzn.to/2JS4bik
    Design of Structural Elements - amzn.to/2LvCMmI
    Gear I Use:
    M1 Mac mini - amzn.to/3tqijkM
    Apple wireless keyboard - amzn.to/3aqPGLI
    iPad Pro - amzn.to/3mMGMMT
    Magic Keyboard for iPad - amzn.to/355GoDd
    Airpods Pro - amzn.to/38MIFEn
    Tonor Mic - amzn.to/3mGRxA1
    Rode VideoMicro - amzn.to/3sMDYTm
    Go Pro Hero 7 - amzn.to/2Ji6bAj
    San Disk SD Card - amzn.to/37SwztP
    San Disk SSD 1TB - amzn.to/37FRWOr

КОМЕНТАРІ • 24

  • @FiftySixish
    @FiftySixish 2 роки тому

    Thanks for this!
    A typical detail I use is to sail the beam over onto a few steel shims located centrally on the padstone and this takes away the additional stress induced due to the eccentric load!
    Love your videos!

    • @EverydayDazz
      @EverydayDazz  2 роки тому

      Yup definitely a good solution I’ve used before too 👍👍

  • @sidj3018
    @sidj3018 Рік тому +1

    Please do a video of a padstone design in the Eurocode Method. Thank you your videos are so helpful so this will be very helpful aswell please as i so struggle with understanding the Eurocode method

  • @kingofthetrowel1725
    @kingofthetrowel1725 2 роки тому

    As a builder I’ve stumbled across your channel and it’s very intersting, thank you and keep up the good work 🙌🏻🙌🏻

  • @ahmadalam5624
    @ahmadalam5624 Рік тому +3

    Hi please do Eurocode please

  • @djsaarus6151
    @djsaarus6151 2 роки тому

    Been waiting for this one Daz! Thank you

  • @edwinclement8962
    @edwinclement8962 2 роки тому +1

    Great example! Will be using the same method in my calcs tomorrow!

  • @py_tok5589
    @py_tok5589 2 роки тому +1

    hey buddy your video help me clarify when and how to apply Bearing type 3 when designing using BS5628-1-2005. very useful indeed . In some non - SIP projects I occasional come across with large opening extensions. I created a program using python to automate the stress bearing checking. I will create an executive file version and email it to you, you may have some curiosity or interest in using coding for youR daily calcs. Tedds is not for me although I have used it before. Licence is quite expensive and Tedds makes us lazy.Thanks Lad.

  • @nejcgorican8302
    @nejcgorican8302 6 місяців тому

    Thanks, very usefull videos. i would also be interested in eurocode version 😊

  • @ChrisSmith-up8nk
    @ChrisSmith-up8nk Рік тому +1

    The resultant force is outside the middle third of the padstone so I don't think the formula you use to check the maximum stress is correct. Because of this you have a triangular distribution of stress under your padstone with a maximum stress of 6.67N/mm2

  • @ssengineering6859
    @ssengineering6859 2 роки тому +1

    What is the reason for using 100mm or 200mm bearing. Can we not do 250 or 300mm bearing on 440 mm long lentil?

  • @elisdoda9446
    @elisdoda9446 2 роки тому +1

    Nice video! :)
    The beam reaction shouldn't be applied at 1/3 of the beam bearing?

  • @kenantaylan3617
    @kenantaylan3617 2 роки тому +1

    Thanks for your sharing . How about if the wall is existing masonry wall, what will be the compressive strength for existing masonry wall?

    • @EverydayDazz
      @EverydayDazz  2 роки тому +1

      If you were doing this properly, you need to get wall sampled and tested.
      On a smaller project, can be safe to assume a lower strength block. Something like 3N block

  • @lenb9037
    @lenb9037 2 роки тому +1

    Your initial calculation at approx 4min 24sec identifies that you also have a negative (tension) presssure of 1.07N/mm2 under the padstone but you do not explain how this is accomodated.
    If this padstone was close to the top of the wall then you could not allow this tension and would have to use middle third law for padstone.
    Also a padstone that was subject to bending tension within itself would likely need to be designed to resist same.
    It is probably better to start off with a lintel bearing length and padstone that adopts the middle third rule and thus remove the problem you have introduced of tension under the padstone and within the padstone that has not been recognised, discussed or dealt with in your explanation.

  • @ThechampforDK
    @ThechampforDK 2 роки тому

    Hello :D
    Great video.
    I was wondering, when you calculate the length of the wall effected by your reaction and spread the load with theta equal to 45degrees, how do you handle the horizontal component to that load which appears, due to the inclination of the load path. To be able to due the spread of the load, don't you need to somehow take care of the tension in your calculation.

  • @jakebillington6817
    @jakebillington6817 2 роки тому

    Great video daz, could you clarify how you got the 0 8 for the bearing factor. I understand the ratio between effective height and effective thickness, but I don't quite get the eccentricity part of the code (0.5t) thank you for your uploads

  • @liamodonnell9091
    @liamodonnell9091 2 роки тому +1

    Do you mind doing a video on chimney breast removals at ground and first floor for example. Highlighting the calculations required to justify removal and the checks required on the wall left?

    • @EverydayDazz
      @EverydayDazz  2 роки тому +2

      i did one recently actually, so can show it in a future video :)

    • @liamodonnell9091
      @liamodonnell9091 2 роки тому

      @@EverydayDazz That would be great, looking forward to it 👍

  • @nikolaisenkevich9198
    @nikolaisenkevich9198 2 роки тому

    Thanks great video! Red book - page 293 also contain Fk table using BS EN 1996-1-1:2005 can this table be used instead of table2 1:49 in video?

    • @EverydayDazz
      @EverydayDazz  2 роки тому

      You need to be careful with using euro code fk and then using BS equations. If you use the euro code fk you should use the euro code equations and material factors.

  • @usmanali-ze1vg
    @usmanali-ze1vg 2 роки тому

    Can you please do a wind calculation video