Liftmaster La400 Dual Unit Install Part 4

Поділитися
Вставка
  • Опубліковано 11 бер 2021

КОМЕНТАРІ • 26

  • @samswain7942
    @samswain7942 13 днів тому

    Why didn't you mount the arm to the lower bar?

  • @crownmoldingbyspectaculart941
    @crownmoldingbyspectaculart941 3 місяці тому

    I have a Liftmaster LA 400 and I just replaced the batteries for the third time since I’ve had it. this time I continue to have a problem with this gate opener and I was hoping you might be able to put your finger on what the problem is.
    Today, when I went out to open the gate, I heard three beeps, and the gate would not move. I hit the reset button and still nothing. It was only when I pulled out the 20 amp fuse and put it back in that the gate would operate. But even then, when I pressed it a second time, I heard the three beeps and it wouldn’t operate until I pulled the fuse again.
    I replaced the fuse but it still does it.
    I put a multimeter on the transformer and it goes up to 24 and then bounces around but 24 seems to be the full trickle charge.
    Any tips would be really appreciated

  • @MarK-gr3xp
    @MarK-gr3xp Рік тому

    Awesome. About to do a big dual gate project, doing some research before the big day.

    • @samswain7942
      @samswain7942 13 днів тому

      How did this job end up going for you. I'm in the same boat

    • @MarK-gr3xp
      @MarK-gr3xp 13 днів тому

      @samswain7942 went great. Sync up the two units, set the open and close points, connected the approach sensor and the close sensor. Also, an entry keypad. Right afterwards someone un-bolted the gate and broke in. Need to install a security camera now.

  • @bartolo152able
    @bartolo152able Рік тому

    good morning friend, a question bot to install a lifemaster 400 but no more I have the 4×4 post plus 3 hinges do you think that if it can be installed and the motor goes inside and the door opens from the inside, could you help me

  • @scotthurdle5661
    @scotthurdle5661 3 роки тому

    Great videos...Question on the Cartel CP-4 automatic gate opener...I wired it just like you mentioned but It wont work...Are you familiar with the CP-4 and its wiring? Any ideas on what am I doing wrong.

    • @jeremystafford365
      @jeremystafford365  3 роки тому

      That one is wired differently, I’ve done those many times also. You will wire the Red to the positive Power and Black for the negative Power on the bottom Connector. Then on the exit terminal you will wire the blue and white to those two terminals.

  • @protectork9831
    @protectork9831 2 роки тому

    Photo sensor is on outside of the property . Is it to help close . ? How about if I want the gate to open when I am approaching it

    • @jeremystafford365
      @jeremystafford365  2 роки тому +1

      The photo sensor is there to sense a person or vehicle while driving through the gate so it doesn’t close on you. When you pass the sensor then it will do its timed delay of how long you set it at. You can set it from 1 second delay to I think 80 seconds.
      If you want the gate to open when you are approaching from the inside then you would install a buried exit loop. If you watch the video I explain each item and how they are hooked up to the unit.

  • @justinjeff2280
    @justinjeff2280 2 місяці тому

    I need part one-three

  • @aandd10
    @aandd10 2 роки тому

    Very nice video ... thanks .... ??? my unit comes with 2 batteries ... can you show me how to install the 2 batteries with the cross connect... thanks

  • @artwuttisak8528
    @artwuttisak8528 Рік тому

    Great video, Have you ever install Maglock MG1300 to LA 400 control board? Can you show how to install them ?

    • @raecross8872
      @raecross8872 7 місяців тому

      Gl1 is far superior lock from Assa Abloy...I've installed several. Mag locks suck because if wire cut the magnet denergizes

  • @raecross8872
    @raecross8872 7 місяців тому

    Direct burial of cabtire? That's not proper cable thus code violation...at least here in Canada....needs to be mechanically protected in pipe.

  • @madolynchase5154
    @madolynchase5154 Рік тому

    I have a LA400 with error code 34, I read thru manual and can not get arm to retract. While the box was open, I did notice a yellow connector/cable is disconnected from left green cable holder inserted into assembly. I’m thinking this is something that needs more than a reconnect from me. We recently had a tornado so I can see where cables would become loose. Is there any easy way to determine which port is its home ? Thank you, Anna from Houston

  • @madolynchase5154
    @madolynchase5154 8 місяців тому

    Its repair turned into a fiasco. $1,300.00 to replace mother board, which I retained, its replacement failed a week later. Company reinserted original board and replaced another circuit. $1,400.00 total repair. They are convenient but expensive to maintain. Thank you

  • @johnsassano8728
    @johnsassano8728 2 роки тому

    What method do you use to run cable under drive

    • @jeremystafford365
      @jeremystafford365  2 роки тому

      Good question. I’ve tried a lot of things. Depending on what kind of soil is under the drive way. This one already had a pipe. If it is dirt you can buy a fitting at home depot that you connect to a pipe and water hose and that works pretty good. If you have rock, then pretty much nothing works unless you want to pay a lot in rental equipment to bore it. In this case I just cut the asphalt or concrete with my Stihl concrete saw about a 1” strip and then repair it.

  • @johnsassano8728
    @johnsassano8728 2 роки тому +1

    So I am having a problem we’re my exit wand doesn’t want to work, this unit also has an access control wired in. Can I hook up both access control and exit wand to the same exit lug?

    • @kenanderson8387
      @kenanderson8387 2 роки тому +1

      Im having same issue!!! Cartell CP-4 exit wand! Doesnt wanna work

    • @johnsassano8728
      @johnsassano8728 2 роки тому

      @@kenanderson8387 did you just install it?

    • @johnsassano8728
      @johnsassano8728 2 роки тому

      @@kenanderson8387 is it an la400 you are installing it on?

    • @johnsassano8728
      @johnsassano8728 2 роки тому

      Black and blue to exit terminal. yellow wire and white wire are negative and red is positive. Make sure you hook up your wires to the 24v power that is constant not to switch one as it won’t work

  • @protectork9831
    @protectork9831 2 роки тому

    Where you located at