EASY: Furnace or Heater Is Blowing Cold Air - Step by Step Diagnosis and Repair

Поділитися
Вставка
  • Опубліковано 25 гру 2024

КОМЕНТАРІ • 533

  • @TightWadDIY
    @TightWadDIY  5 років тому +18

    Let me know if you have any questions by leaving them in the comments section! Yes, I flipped the wrong breaker in the video. Sorry for the mistake but you get the point.
    Here is a link for the limit switch I used.
    Primary Limit Switch - amzn.to/2YBShvH

    • @TightWadDIY
      @TightWadDIY  5 років тому +2

      Chris B In Philly Alligator clips are a great option for jumping switches when testing. I never show that because most home owners don’t have them.

    • @fierrofierro5721
      @fierrofierro5721 4 роки тому +1

      Bro thank you veeery much! I woke up at 2 am and my house super cold and i got my wife and kids! I had to make my furnace work so your video helped me out 100%! The safety switch was my problem! Thank u so much! 💪👏 instead of the paper clip i had my terminal kit so endep up using 2 spade connectors and left it running for 30 min just to get the house warm and now turning it off completely just to go to sleep!

    • @TightWadDIY
      @TightWadDIY  4 роки тому +2

      Fierro Fierro That is great! I’m glad you were able to get it running temporarily. Hopefully you can find a new switch today to fix it.

    • @Markandmeplus3
      @Markandmeplus3 4 роки тому +1

      Can you make a video on how to fix a
      dual fuel board
      Outdoor thermostat and
      outdoor contactor?

    • @TightWadDIY
      @TightWadDIY  4 роки тому +3

      Brittany Lil Bae Davis Sorry, I’m not an HVAC tech. I only repair what breaks in my home and family members’ homes.

  • @MMR3d
    @MMR3d 2 роки тому +46

    I’m a single mother and this shut down on me overnight. With my daughter in mind, I had to figure something out that wasn’t going to cost so much. Thank you so so much!! I watched this video over and over and followed every step minus the breaker. I’m super happy right now and proud.

    • @TightWadDIY
      @TightWadDIY  2 роки тому +4

      Yay! I’m glad you were able to get yours fixed!

  • @Randallsixx13
    @Randallsixx13 3 роки тому +9

    This sort content is why UA-cam exists. Thanks so much for posting this.

    • @TightWadDIY
      @TightWadDIY  3 роки тому

      Hopefully you got yours fixed too!

  • @queenshanda8152
    @queenshanda8152 Рік тому +2

    Single mother here! Thanks for all your help!!! You saved so much money! New subby!

  • @best1213best
    @best1213best 2 роки тому +10

    Our furnace was having an issue and of the dozen videos I watched today, this was the only one that helped! Very educational and helpful! Thank you!

    • @TightWadDIY
      @TightWadDIY  2 роки тому +1

      That’s great to hear! Thanks for taking the time to leave a comment.

  • @mikejetson5308
    @mikejetson5308 2 роки тому +6

    Just wanted you to know that your video is still helping people . Its hard to find a good video that explanes things as well as your did for me . I had the same code as seen here and a simple reset was all i needed to fix the problem . Keep up the good videos your doing . They are saving people money and you will reap the rewards of your time . Thank You So Much 👍

  • @reneegoforth4929
    @reneegoforth4929 2 місяці тому +2

    Thank you! Thank you! Thank you! I got my furnace working thanks to your easy steps! It was the turn-on button in front of the furnace. Had to have the front panels on just right to keep it pressed down.
    I did it. Thanks to you! 🎉❤ You are a lifesaver!

  • @MaximumGameplayCanada
    @MaximumGameplayCanada 3 роки тому +8

    God bless you for this my man, i have been trying everything since a week, changed new flame sensor, changed ignator, unplugged and replugged all wires ( that was hard i had to litterally draw them in a peace of paper), cleaned the burners, oiled the inducer motor....works sporadically after system lock down like 4h, and then returned back to on and off, never thought it was the limit switch, did the paper clip trick, i almost shit my pants and even with main power off i was afraid on being electrocuted or sparks that can go to gaz pipe not that faraway, but holly shit man, it worked at every single attempt, now i am ordering it from Amazone and will certainly not operate furnace with a paperclip to burn the house.GOD BLESS YOU MAN.

    • @TightWadDIY
      @TightWadDIY  3 роки тому +1

      Yes! I’m glad it worked for you too!

  • @usmanpervez9390
    @usmanpervez9390 2 роки тому +5

    My unit blowing cold air and by following your video I think I should be able to fix my own furnace. You are awesome 👌

    • @TightWadDIY
      @TightWadDIY  2 роки тому

      Hopefully it works for you too!

  • @kraftp
    @kraftp 25 днів тому

    I love you. Flipped the breaker, cleaned the flame sensor, now i have heat. Thanks boss

  • @aathmpsn
    @aathmpsn 5 років тому +14

    THANK YOU! Cleaning out the little blower vacuum hose worked for me!! Took me hours and lots of videos, and yours fixed my situation. Thank you :D

  • @NesliTD
    @NesliTD 2 роки тому +1

    Like one of your other commentators I am also aa single mom and of course my furnace went out in the middle of the night. I was able to fix it with these instructions. I need to change the filter more frequently going forward. Thank you!

    • @TightWadDIY
      @TightWadDIY  2 роки тому

      That’s great! A dirty filter can cause major issues because it suffocated the system.

  • @stevenwillis7271
    @stevenwillis7271 4 роки тому +2

    this was a great video, it should me what to look for and how to fix it, my problem was it was blowing cold air, i did what the video showed me but still the burners would not come, so i blew air from my mouth toward the heat sensor and a lot of dust came off then it started glowing red, then the burners lite and the furnace was heating the house again, this also showed me that the furnace had not been serviced in some time, i had just recently purchased the house and it was working at the time. Now i can just call in a tech to service the unit and clean everything. before this house i had always had my furnace serviced every year and that will be the same with this one. In the long run it will avoid you having to pay a premium price to have them come out on a overtime call.

  • @reesenelson2360
    @reesenelson2360 3 роки тому +3

    I want to Thank you for your video your a life saver I woke up this morning furnace blowing cold air temp outside 8, I followed your video and now as I speak my home is warming back up👍 thank you again keep up the Great work Have a safe and Blessed 2021...

    • @TightWadDIY
      @TightWadDIY  3 роки тому

      That’s great! I’m glad it worked for you too! Stay warm!

    • @n2metal2
      @n2metal2 3 роки тому

      Same here. This was the only video I found that showed this with the switch on a Lennox. Thanks again.

  • @UnknownMe321
    @UnknownMe321 4 роки тому +6

    This might be the most helpful video I have found

    • @TightWadDIY
      @TightWadDIY  4 роки тому

      I’m glad it worked for you too! I have over 200 helpful DIY style videos so please consider subscribing.

  • @gailkwas9866
    @gailkwas9866 2 роки тому +5

    I would like to THANK YOU so much for your easy way of explaining this to us. It worked perfectly. After the family Christmas gathering, we came home on Christmas day to a cold house. Great I thought. But thank goodness it was the first thing, you mentioned on your video, the corrosion on the rod. I had visions of the callout and them taking their sweet time in diagnosing the problem and costing me about 500.00 again. It's a Very Merry Christmas after all 😊 Thanks again you made my day!!

    • @TightWadDIY
      @TightWadDIY  2 роки тому +1

      I’m really glad to hear it worked for you too!

  • @globalrsservices1328
    @globalrsservices1328 5 років тому +5

    This video helped. @2:50 My inductor blower tube was clogged. I blow in the tube and no air was flowing throw. I took a piece of wire to clean out. It cleared. Then i put everything back together and the ignitor started glowing again and ignited. Wow.
    Thanks!

    • @TightWadDIY
      @TightWadDIY  5 років тому

      Global RS Services That’s great! Thanks for sharing your success story.

  • @JoseTrevino-r1h
    @JoseTrevino-r1h Місяць тому +3

    Nice the flashes of the green light tells you what's wrong with the unit

  • @vlmmnadet1304
    @vlmmnadet1304 3 роки тому +4

    Thank you so much for this video, a very thorough and informational presentation. Praise God for people like you.

    • @TightWadDIY
      @TightWadDIY  3 роки тому +1

      I’m glad you enjoyed it.

    • @veronicapheasant3233
      @veronicapheasant3233 2 роки тому

      Great video. Ours does all this but then the burners goes out like the gas gets shut off. Blower will keep running. It was intermittent last year but this year it won't even stay running. Our thermostat is also very old.

  • @edcar6090
    @edcar6090 2 роки тому +2

    I fixed my heater thru your video. Thank you sooooo much.

    • @TightWadDIY
      @TightWadDIY  2 роки тому

      That’s great) I’m glad it worked for you too!

  • @nightprowlerch19
    @nightprowlerch19 2 роки тому +3

    Dude thanks I totally fixed my furnace because of this Video

  • @justsaiyansteve
    @justsaiyansteve 5 років тому +5

    This is actually one of the best videos ive seen.

    • @TightWadDIY
      @TightWadDIY  5 років тому

      JustSaiyanSteve That’s a strong compliment. I appreciate it.

  • @BCM1959
    @BCM1959 11 місяців тому +3

    Five years later and still relevant. Thanks.

    • @TightWadDIY
      @TightWadDIY  11 місяців тому

      I’m glad you found it helpful!

  • @deevinfestejo5152
    @deevinfestejo5152 3 роки тому +7

    Very clear presentation of the steps in troubleshooting furnace blowing cold air instead of warm/hot air! I simply love it because I was able it fix my own furnace by simply following his lead!

    • @TightWadDIY
      @TightWadDIY  3 роки тому

      That’s great news! I’m glad it worked for you too. Be sure to subscribe!

  • @milvolts1
    @milvolts1 2 роки тому +1

    I'm trying this tonight. Greatly edited informational video

  • @armandoherrera6165
    @armandoherrera6165 5 років тому +5

    Thank you so much you just save me $400 and alot of stress.

    • @TightWadDIY
      @TightWadDIY  5 років тому +1

      Armando Herrera You are welcome! I’m glad you were able to get it fixed.

  • @X_Y_Z2024
    @X_Y_Z2024 5 років тому +9

    You're my hero! I fixed it myself.

    • @X_Y_Z2024
      @X_Y_Z2024 5 років тому +1

      With your instructions of course! Thank you thank you!!!

    • @TightWadDIY
      @TightWadDIY  5 років тому +1

      adjoadjo Thata Great! I’m glad I was able to help. Be sure to subscribe.

    • @X_Y_Z2024
      @X_Y_Z2024 5 років тому +3

      @@TightWadDIY you bet!!! I think its so important for women to know these things. We probably spend more $$$ than most, because we panic, dont know, or we get screwed over by repairmen!

  • @martinxavier4300
    @martinxavier4300 11 місяців тому +1

    Thanks man just cleaned and got a filter cut it off and back on. Working great now

  • @tannettejohnson4507
    @tannettejohnson4507 5 років тому +2

    This video is what I needed to help me get my furnace working properly "myself". Thanks for the "how to"!

    • @TightWadDIY
      @TightWadDIY  5 років тому

      That’s great to hear! Let me know if you have any questions. Be sure to subscribe so you can keep doing it YOURSELF!

  • @AaronSBrown
    @AaronSBrown 2 роки тому +1

    Cleaned the sensor and now I have heat again! Thanks!

    • @TightWadDIY
      @TightWadDIY  2 роки тому +1

      Great! I’m glad it worked for you too!

  • @bmcdiddy1
    @bmcdiddy1 4 роки тому +4

    Thank you so much! Helped me big time. I did everything you said to do in the video plus I also removed the limit switch and tapped on it a few times with the end of my screw driver (to make sure it was closed?). Not sure which step fixed my issue but now my heater works! Thanks again

    • @TightWadDIY
      @TightWadDIY  4 роки тому

      Brian M That’s great! I love a success story! Thank you for sharing. Be sure to subscribe.

  • @toksgabriel2230
    @toksgabriel2230 4 роки тому +2

    THANK YOU ....excellent step by step explanation and I was able to get my furnace running
    FYI...had three PSEG technicians at different occasions...furnace will work for two or three days and off it goes

    • @TightWadDIY
      @TightWadDIY  4 роки тому

      That’s great! Hopefully it keeps running this time!

  • @Kingreaper666
    @Kingreaper666 3 роки тому +2

    Thank you so much. I tried a few other things before I found your video. Nothing worked, all I needed to do was clean my sensor you talked about and I have heat again. Super easy fix thanks so much....

    • @TightWadDIY
      @TightWadDIY  3 роки тому

      That’s great! I’m glad it’s working again!

  • @andrewahlers9563
    @andrewahlers9563 5 років тому +4

    Thank you so much man your helped fixed my furnace with just a screwdriver!

    • @TightWadDIY
      @TightWadDIY  5 років тому

      Andrew Ahlers That’s awesome! What was wrong with yours?

    • @andrewahlers9563
      @andrewahlers9563 5 років тому +1

      @@TightWadDIY just needed cleaning.

    • @TightWadDIY
      @TightWadDIY  5 років тому

      Andrew Ahlers That’s great! The best repair is a free one!

  • @mayurkrish75
    @mayurkrish75 5 років тому +1

    This video is great..! I had the same problem and I straight went to clean the flame sensor which did not help. Then I came across this video which helped me to check if the valve (orange tube part in the video)is blocked and IT WAS....in my case. Just cleaned it with paper clip and the system now runs like champ. Many thanks to you because you saved me lot of trouble and money...!

    • @TightWadDIY
      @TightWadDIY  5 років тому

      mayur darji Thata greAt! I’m glad you found the video and that one of the tips helped you. Be sure to subscribe.

  • @DisFashoJaymann
    @DisFashoJaymann 3 роки тому +4

    That paper clip trick worked!!! Had to comment.

    • @TightWadDIY
      @TightWadDIY  3 роки тому

      That’s great! I’m glad you have it figured out.

  • @Foxtrotwilconiner1969
    @Foxtrotwilconiner1969 10 місяців тому +1

    The best piece of advice do it every year with soft nylon scrubber for kitchen and the flame sensor works again

  • @marshay191
    @marshay191 4 роки тому +1

    Omg!!! The best life saving video ever❤️❤️❤️❤️ 1st thing make sure vents are clean, 2nd if the heat still doesn't cut on, switch the gas fuse for the heat and BOOM, pilot cuts on and it's warm again.

    • @TightWadDIY
      @TightWadDIY  4 роки тому

      Glo.N Grow I’m glad you found it helpful! Be sure to subscribe!

  • @danielrodriguez9538
    @danielrodriguez9538 4 роки тому +1

    I had the same problem with my furnace and I found this very well explained video and l was able to find the problem to my furnace thank you for this very helpful video. money $$$$ saver.

    • @TightWadDIY
      @TightWadDIY  4 роки тому

      Daniel Rodriguez I’m happy to hear you found it helpful.

  • @davidcenteno7254
    @davidcenteno7254 10 місяців тому +1

    Thank you for your video,, it was very helpful. it became a simple reset issue. God bless you.

  • @bentback1
    @bentback1 4 роки тому +1

    Very good demo' you and "word of advice TV " produce the best repair advice.

  • @Bambina336
    @Bambina336 5 років тому +1

    I am so happy that I found your video. I was searching for Lennox furnace/system but everything that came up looked different or was a different brand too. Just when I was ready to give up, your video started playing. I have that exact system and it just stopped heating. I can hear it starting as it usually does but after 2-3min it shuts off. No heat comes out of the vents. If I turn Fan to On the cold air starts coming out, otherwise no air at all. I hope it's the first two things you showed here and that I'll be able to fix it myself. On Lennox system it seems much easier to access some of these places than on other systems I saw on here. Thank you so much for making and sharing this video!

    • @TightWadDIY
      @TightWadDIY  5 років тому +1

      Bambina336 I’m glad you found it too. This one was very easy to work on. The one in my house is much more difficult. Let me know if it works for you or not.

    • @deecortan5061
      @deecortan5061 5 років тому

      Yes, I'll definitely report back once I check it tomorrow. But just to be sure I understood correctly - I need to turn power off at the system before checking on first two things or is that not necessary if my system too has that switch in a corner?

    • @TightWadDIY
      @TightWadDIY  5 років тому +1

      Dee Cortan You need the power on to test the system. Make sure you turn it off before messing with the wires though.

    • @Bambina336
      @Bambina336 5 років тому

      Thank you TightWadDIY!

    • @Bambina336
      @Bambina336 5 років тому

      Unfortunately, cleaning the heat sensor didn't help. I did not remove that little red tube because mine is so rigid that it looks like it will break if I try to move it. I think I'll have to call someone in to check it out.

  • @Whytedebil
    @Whytedebil Рік тому

    Very helpful at my daughters today. Kudos to you sir. Probably would’ve waited a month on the landlords “handyman” followed by a few more days for an hvac company after un-handyman failed to diagnose or remedy. Big ups to you guys. Subbed.

  • @sarbbhamra6758
    @sarbbhamra6758 Рік тому +1

    Thank you 🙏 so much for the video. God bless you

  • @kc7797
    @kc7797 3 роки тому +2

    Very useful video. Easy and clear to understand to identify to command problem of the furnace. Keep up the good work! Thanks.

    • @TightWadDIY
      @TightWadDIY  3 роки тому

      Thanks! I appreciate the thoughtful comment. Be sure to subscribe!

  • @jeffharrison1090
    @jeffharrison1090 4 роки тому

    i have a York Diamond 80 Furnace. And twice now over the years it has shown 4 Flashing lights with is the standard
    5 flash code for: Dirty filter, improperly sized duct system, incorrect blower
    speed setting, incorrect firing rate or faulty
    blower motor. HOWEVER each time for me it's truly been-->The Ignitor!!! 4 years ago 4 flashes, Changed Ignitor..works!
    Just today, same thing!
    Each time both in the past, I would change the High Limit switch and nothing but cold air. The
    Ignitor would
    NEVER glow. Then for the hell of it I change the ignitor and BAM...it glowed red, ignition! Each time advise
    on phone from various support, they always "respected" the listings on the door about limit switches, filter, blower perhaps
    to slow, bad circuit board...and concentrated their efforts there! I've kept the OLD ignitors (for some reason) and decided
    to OHM test them. The 1st ignitor that failed 4 years ago has 40 ohms reading. The one just today has 85 ohms reading.
    The brand new one that is working now...tested it right out of the box has 60 ohms reading! The range according to most
    techs, manuals say ignitor should be between 30 and 90 ohms.
    In your experiences, can a "good" circuit board produce incorrect codes? According to the York Manual on Page 7 there is
    only
    ONE code relating to the ignitor and that is "7" flashes --> Flame Could Not Be Established! I suppose that's why all the
    techs disregarded any suggestion of changing the ignitor because code was 4 flashes! On the other hand, boards and
    codes can only do what designer instruct them to do. Or perhaps a revise manual should state ignitor as another check!
    I ordered and had a new high limit switch available. But after I had BY-Passed the High Limit swith and the ignitor failed to
    glow,
    I got suspicious. The inducer appears strong, no clogs/filter issues, nothing duct-wise changed...so it seemed
    Spock)
    that the next stage after inducer/blower was the ignitor. So far that is the ONLY part of my York 80 that I've had to change out in 20 years! It's also one of the cheapest parts on the list of repairs too! thankful about that.

  • @juanofkind8122
    @juanofkind8122 5 років тому +7

    THANK YOU SO MUCH ! YOU SAVE ME AROUND $700 DOLLARS

    • @TightWadDIY
      @TightWadDIY  5 років тому +3

      juan of kind That’s great! Just send me $100 then...what a deal! I’m glad you were able to get it fixed.

    • @Yoyosten99
      @Yoyosten99 4 роки тому +1

      @@TightWadDIY For real though most maintenance people are crooks. Awhile back my buddy had furnace issues, same issue as this, the guy tried charging him several hundred just for the assessment which took 2 minutes and told him what the repair would cost which was several hundred more on top of that. My friend just thanked him for telling him what's wrong, and said no thanks, that he'd be repairing it himself because that charge was insane. Flat out refused to pay for the assessment and told the man to leave. Most repairmen these days will take advantage of people because they don't know any better or have any mechanical skills whatsoever. Luckily my friend, although not knowing how to diagnose the issue, did know that parts and labor were nowhere near what they should have been. You've got to be a real POS to try and con a war veteran who's disabled and unable to work.

    • @TightWadDIY
      @TightWadDIY  4 роки тому +3

      Yoyosten99 It is sad that some repair companies are crooked. I believe that most aren’t and that’s why you should always use referrals. I believe $150-$200 total is reasonable for this type of diagnosis and repair since you have to compensate them for their knowledge and time.

  • @pw0107
    @pw0107 4 роки тому +3

    Had to clean my flame sensor with sandpaper and now I'm back up and running. Thanks!

    • @TightWadDIY
      @TightWadDIY  4 роки тому

      That’s great! I’m glad it worked for you too!

  • @phonetechatwork
    @phonetechatwork 2 роки тому +1

    You’re a legend. Thank you

  • @tkhemjinda
    @tkhemjinda 4 роки тому +1

    Thanks man I think my switch is bad too. I'm going to try the test you showed.

  • @Dty555
    @Dty555 9 днів тому +1

    A little knowledge can be dangerous. If you do a power down reset at the breaker panel, be very aware that power is available in the furnace. Its always better to check once too many than once too few. At the least you might cause more system damage than at the start, at the worst you or a loved one can be killed. Electricity is intolerant of mistakes.

  • @pmalman
    @pmalman 3 роки тому +1

    Video is very helpful. Replaced flame sensor. Furnace is working now but sometimes it stops with rapid red code. When I restarted it works again for a while but will stop working with rapid red again.

    • @TightWadDIY
      @TightWadDIY  3 роки тому +1

      Check your charts to see what the new code means.

  • @williamspiller5032
    @williamspiller5032 2 роки тому +1

    GREAT JOB AND EXPLANATION.

  • @philindeblanc
    @philindeblanc 5 років тому +3

    I'm getting the Roll Out switch code blinking. So this looks like it maybe the same issue as yours. Had not thought to close the circuit to test. Good idea. Will try that . Thanks.

    • @TightWadDIY
      @TightWadDIY  5 років тому

      Phil Indeblanc Hopefully it’s an easy fix. Let us know how it goes.

    • @ZERO-F2G-
      @ZERO-F2G- 5 років тому

      Roll out switches are different then the high limit. They are usually one time, or resettable switches. they are safety switches in the event of flame rollout, the most common cause of flame rollout is 1) lack of combustion air to mix with the gas, 2) less often but possible, cracked heat exchanger.
      If you are getting a code for rollout switch call a professional.

  • @alnuaemeaburawa7630
    @alnuaemeaburawa7630 3 роки тому +1

    Thanks alot, y r the man!
    brief and quiet beneficial.

    • @TightWadDIY
      @TightWadDIY  3 роки тому

      I’m glad to hear you found it helpful. Be sure to hit that thumbs up and subscribe!

  • @El_LeChErO91
    @El_LeChErO91 Місяць тому +1

    Dude i tried everything! Even considered and thinking it might be the rollout switch. Im done for today but as soon as im out of work tomorrow im try your method with the paperclip. I have the same system and the same light pattern going on. I really hope this works. I will update tomorrow if this works.

    • @TightWadDIY
      @TightWadDIY  Місяць тому

      You got this!

    • @El_LeChErO91
      @El_LeChErO91 Місяць тому

      @ so update i know its almost 2 weeks but your paperclip method worked. Turns out it was the high limit switch it was done for no juice left in it. I was able to replace and voila we got heat!

  • @heinzbaron9129
    @heinzbaron9129 2 роки тому +1

    Fabulous name.
    The video is great too.

    • @TightWadDIY
      @TightWadDIY  2 роки тому

      Thanks! I’m glad you liked it!

  • @noladude5046
    @noladude5046 5 років тому +4

    Please keep the great informative videos coming!

    • @TightWadDIY
      @TightWadDIY  5 років тому +1

      Noladude504 I plan to! I should have another video out very soon.

  • @randyallender8797
    @randyallender8797 5 років тому +20

    I am a multi licensed, well vetted HVAC/R Technician and Teacher....and there are some things I agree with you said, but more things I whole heatedly disagree with.
    For starters.....never ever never ever use a paper clip to jump an electrical circuit. This is a safety issue, it can cause a short, and it is not a common field practice PERIOD! Use alligator clips, a jumper wire, or just cut and splice the wires together
    Next, Safety Switches are not pet goldfish, they just don't die/fail. They fail from opening and closing over time, or being exposed to extreme conditions. Anytime you condemn a SAFETY SWITCH, you MUST find out why it failed. Air flow is most likely your biggest culprit. After you jump the switch out, check the amp draw on the blower motors, draft and indoor, check your filter (you did mention this, kudos) and take a Delta T (temp rise across the furnace) and confirm your air flow is adequate and make corrections as needed. May not be a bad idea to check gas pressure either....something overheated and opened that switch.
    The igniter is not a switch, its a load.
    Your turned off 29 not 27 in your panel

    • @TightWadDIY
      @TightWadDIY  5 років тому +5

      Randy Allender I definitely appreciate your input. I will pin your comment so others can see it as well.

    • @naomilopata9266
      @naomilopata9266 3 роки тому +1

      Maybe you should make a video...this is helping but would be great if you walked through it live.

    • @brotito9126
      @brotito9126 3 роки тому

      I retired from the HVAC Trade after 35 years-Sheet Metal. His video was more than enough to solve the problem with my Furnace.

    • @brotito9126
      @brotito9126 3 роки тому +1

      Wrong is wrong nonetheless. Glad he wasn’t ego trippn and took your constructive criticism well. Classy👍🏽

    • @stevenmachnick9613
      @stevenmachnick9613 2 роки тому

      Omg you literally read my mind. I strongly suggest he stops giving people information. I get it he may be helping so e people. But I can't stress enough that it is so important to have a licensed qualified technician look at your furnace or ac.

  • @melgueta1
    @melgueta1 5 років тому +1

    Excellent video and helped me to find the same issue on my York G8C series. Thank you!
    I would like to add that on my case I noticed that red led was flashing 4 times inside the furnace

    • @TightWadDIY
      @TightWadDIY  5 років тому

      Marcelo Elgueta That’s great! I’m glad it worked for you too!

  • @Don_30.87
    @Don_30.87 4 роки тому +1

    Thanks buddy. 5 star video

  • @gloriamurley385
    @gloriamurley385 3 роки тому +1

    I gave your video a thumbs up👍.

  • @michaelpiecewicz9748
    @michaelpiecewicz9748 3 роки тому +2

    Thank you this is a great video. Needed to know if it was a Normally open or normally closed switch. I got to the right part by the wiring diagram and you took me the rest of the way!!! I just love the fact that everything I learned in automotive school works all over the house. Thanks again

    • @TightWadDIY
      @TightWadDIY  3 роки тому

      That’s great! I’m glad it worked for you too!

  • @yermiyahbenisrael7182
    @yermiyahbenisrael7182 5 років тому +3

    Thank you for the video brother. You just saved me a lot of money: very helpful video

    • @TightWadDIY
      @TightWadDIY  5 років тому +1

      Kevin Butler You are very welcome. I can send you my PayPal if you want to send me half of what I saved you! Haha. Just make sure you hit the thumbs up and subscribe!

  • @lonniebarrios5101
    @lonniebarrios5101 4 роки тому +2

    Thanks for the video! My Amana 80 SSE is blowing cold air. The inducer and blower motor come on, but nothing else happens. After a few seconds, the inducer turns off and the blower runs continuously. The control board is blinking 4 times indicating an open primary/secondary limit switch. At first, I jumped the wires for the primary (before I realized my unit actually did have a secondary limit switch with a manual reset). No joy. After I traced the wires from the primary, I found the secondary and jumped those wires (after reconnecting the wires for the primary). Same results and 4 flashes. I suppose that both switches could be open and since I was only testing one at a time it still wouldn't work, but that would suggest that both switches failed at exactly the same time and I think that is unlikely. I haven't checked the tube to the pressure switch (mainly because there's a code - 3 blinks - for that). I don't see the igniter glowing because I think I have to remove the cover that the flame sensor is attached to. If the flame sensor is dirty, could that still be the cause of the problem and make the unit report that the limit switch(es) are open? It seems like that error code is a catch-all and that there could be many culprits. Any suggestions?

  • @RodSpannTV
    @RodSpannTV 2 роки тому

    Thank You Very Much and May God Bless You!!

  • @exxon24
    @exxon24 2 роки тому +2

    You are the man thank you

  • @ZERO-F2G-
    @ZERO-F2G- 5 років тому

    As a 33 year HVAC tech, I am pretty confident saying that filter looks to be a washable electro static filter. If it is then most likely the furnace is always running at the high end of the temp rise. And the limit switch probably tripped and reset hundreds of times and then failed, when it should in theory never trip, high limit switches are extremely reliable when operating in proper temp range.
    If you take good entering and leaving temp readings near the furnace you can determine if the furnace is operating in range, preferably near the middle.
    It requires a magnahelic or manometer and static pressure tips, but taking static pressure readings and comparing the pressure drop to the manufacturers fan curve is one of the best ways to know if the airflow is correct. Sadly many units have undersized duct work that already pushes static high and thus reduces airflow, add in a restrictive filter and often airflow reduces to unacceptable levels. And electrostatic filters are the worst of the worst when it comes to that, next worse is 3M filtreete brand filters. Both often have pressure drops across a clean filter at half or more of what the blower can handle.
    In cooling it can cause the evap coil to freeze, and in heating it can cause gas furnaces to run above max temp rise.

    • @TightWadDIY
      @TightWadDIY  5 років тому

      VapoRTraiL111 Is there another filter you recommend instead?

    • @ZERO-F2G-
      @ZERO-F2G- 5 років тому

      @@TightWadDIY I recommend the best filter that doesn't impact proper CFM delivery.
      So unless you have some data, there is no recommendation beyond standard fiberglass filters.
      You have to know if the system is within proper CFM with no filter in place, if its not than any filter reduces CFM.
      if it is delivering proper CFM, you need to know what the static pressure it is working at, then it can be determined how much pressure drop can be allotted to the filter. A filter that meets requirements can then be selected.

  • @shemecawilliams6089
    @shemecawilliams6089 2 роки тому +1

    Thank you Kindly your video really helped.

    • @TightWadDIY
      @TightWadDIY  2 роки тому

      Great! I’m glad it worked for you too!

  • @alakers0505
    @alakers0505 2 роки тому +1

    The breaker worked first time thanks

  • @nemozo
    @nemozo 2 роки тому

    Love your videos! Keep them coming. I'm learning so much.

    • @TightWadDIY
      @TightWadDIY  2 роки тому

      Thanks for taking the time to leave a kind comment!

  • @herchang3553
    @herchang3553 Місяць тому +1

    Thank you so much for your video

  • @joes.9448
    @joes.9448 3 роки тому +1

    I found your video to be very easy to understand and follow. I replaced my limit switch but still not getting the hot air. Any suggestions?

    • @TightWadDIY
      @TightWadDIY  3 роки тому +1

      Did you check the error codes on your unit?

    • @joes.9448
      @joes.9448 3 роки тому +1

      @@TightWadDIY I was getting 7 flashes. I went ahead and cleaned the ignitor probe and it seems to be working now. 😀

    • @TightWadDIY
      @TightWadDIY  3 роки тому +1

      @@joes.9448 That’s great news!

    • @joes.9448
      @joes.9448 3 роки тому

      @@TightWadDIY thank you for your video. It was very informative and helpful.

  • @azremodeling8392
    @azremodeling8392 2 роки тому +2

    Great video to watch

  • @Crazy-Humans
    @Crazy-Humans 4 роки тому +1

    Dude, Thank you. Wow. Life saver. You are magnificent.

    • @TightWadDIY
      @TightWadDIY  4 роки тому +1

      I’m happy to hear it worked for you too!

  • @vince6829
    @vince6829 2 роки тому

    Thank you for sharing your knowledge.

  • @kellyneal8185
    @kellyneal8185 2 роки тому +1

    Thank you so much for your help!

  • @brendarodz87
    @brendarodz87 5 років тому +2

    Thank you so much for the video!!!!.
    I cleaned the sensor then I unplugged the limit switch and try the paperclip but didn't work. When I plugged the cables back started to run again.
    👍

    • @TightWadDIY
      @TightWadDIY  5 років тому +1

      Brenda Rodriguez I’m glad you are back up and running!

  • @danahsutton101
    @danahsutton101 3 роки тому +1

    Do you have to turn the power back in to the furnace to check?

  • @brianturner9657
    @brianturner9657 5 років тому +2

    Man this is fantastic information

    • @TightWadDIY
      @TightWadDIY  5 років тому +1

      Brian Turner I’m glad you found it helpful. Be sure to subscribe!

  • @tampham3403
    @tampham3403 3 роки тому +1

    Thankfully, good video

    • @TightWadDIY
      @TightWadDIY  3 роки тому

      I’m glad it worked for you too!

  • @pablogomez7519
    @pablogomez7519 4 роки тому +1

    I checked the continuity on the limit switch and it's good. I was told the inducer turns on first then the gas valve then the igniter but I hold the door switch but nothing turns on but the blower

  • @El_LeChErO91
    @El_LeChErO91 14 днів тому

    Now my problem with my lennox furnace is slow alternating lights which is the watch gaurd with 3 potential issues. I cleaned my igniter and sensor both that sit in front of burners and nothing. You have any ideas? I come to your channel because you previously helped me with the high limit switch.

  • @danielcleary1072
    @danielcleary1072 3 роки тому +1

    Very helpful! Thank you!

    • @TightWadDIY
      @TightWadDIY  3 роки тому

      Hopefully you get yours fixed!

  • @budbusenius3091
    @budbusenius3091 Рік тому

    Thank u. Thank u . Thank u . Dirty rubber hose needle worked ,your awesome. -20 c in Alberta weekend ? ATA boy

  • @lorenzoalmanza4765
    @lorenzoalmanza4765 3 роки тому +1

    Gracias por compartir excelente información 👍👍

  • @gwangione9406
    @gwangione9406 4 роки тому +2

    A simple thing like turning the power off on the board for a couple minutes and we are back in action. Go figure. Thanks much for the video

    • @TightWadDIY
      @TightWadDIY  4 роки тому

      That’s great! Sometimes things just need to be reset!

  • @jslenmunson23
    @jslenmunson23 Рік тому +1

    Thank you❤

  • @noladude5046
    @noladude5046 5 років тому +2

    Very well done informative video! Thank you.👍

    • @TightWadDIY
      @TightWadDIY  5 років тому

      Noladude504 Thank you for the kind words. You are very welcome.

    • @lindabaker1776
      @lindabaker1776 3 роки тому

      are those flames suppose to stay on at all times

  • @georgemendez8747
    @georgemendez8747 2 роки тому

    Hi question do you if the common is the one wire or the 2 wires.

  • @nothating
    @nothating 4 роки тому +1

    i defiantly subscribed to you. I absolutely forget were the wires go .

  • @bernardpoole9123
    @bernardpoole9123 2 роки тому +1

    Is a gas line propane or natural suppose to have a dirt leg

  • @auroraboringalice596
    @auroraboringalice596 3 роки тому +2

    Great information! BTW, your brother's breaker-box does not match the chart. You were turning on & off #29, not #27. He might want to sort that out! 😬

    • @TightWadDIY
      @TightWadDIY  3 роки тому +1

      I had to re-record that part of the video and I flipped the wrong switch.

  • @rogerglatzhofer4138
    @rogerglatzhofer4138 3 роки тому +1

    Great video. Thanks :)

    • @TightWadDIY
      @TightWadDIY  3 роки тому

      Thanks! I hope you are able to get yours working again.

    • @rogerglatzhofer4138
      @rogerglatzhofer4138 3 роки тому

      I followed your instructions and steps and within ten minutes I had the furnace running smoothly again. No replacement parts needed, no service charges to pay. You're my first stop from now on !! Five stars all day. Many, many thanks. :) :)

    • @TightWadDIY
      @TightWadDIY  3 роки тому

      @@rogerglatzhofer4138 That’s awesome! I’m glad you were able to get it running with no new parts needed!

  • @ronaldmurphy8573
    @ronaldmurphy8573 11 місяців тому +1

    Reset and fixed!

  • @haroldstewart9960
    @haroldstewart9960 2 роки тому

    Very helpful, thank you.
    But I have a question?
    I have a carrier Infinity furnace, it come on heats in low for bout a minute, then stops

    • @TightWadDIY
      @TightWadDIY  2 роки тому

      Any error codes? Sounds like you have a blockage or something is overheating.

  • @corbinbuttrey7391
    @corbinbuttrey7391 Місяць тому

    What exactly is that tube in the beginning? My hot surface igniter isn't glowing, I figured that needed to be replaced.

  • @streetcruise9807
    @streetcruise9807 2 роки тому

    When enducor motor goes bad do you need to change the whole furnace? My furnace is over 40 yrs old

  • @omarpral
    @omarpral 5 років тому +1

    thanks so much I was panic my house start getting colder I live in Minnesota you know how is it up here. hey but I just cleaned the burner sensor is running and warm but I still have red & green light flashlight you think I should change the sensor you did on video?

    • @TightWadDIY
      @TightWadDIY  5 років тому

      Omar M.T You don’t have an issue with the limit switch if your system is running now.

    • @omarpral
      @omarpral 5 років тому

      @@TightWadDIY yes you right is was burner sensor everything work perfect now . but thanks for sharing that video im new home owner i don't have to much experience . good video 👏🏾👏🏾👏🏾👏🏾👏🏾👏🏾👏🏾👏🏾👏🏾👏🏾👏🏾👏🏾

  • @lastknight7778
    @lastknight7778 Рік тому

    Should the thermostat be on heat for testing?