RV Automatic Generator Transfer Switch Installation - Southwire TRC

Поділитися
Вставка
  • Опубліковано 29 лип 2024
  • In this video I will be installing a TRC / Southwire automatic transfer switch into my 2004 Winnebago Minnie Winnie Class C motorhome. This allows me to easily switch between shore power and generator power without plugging in to the generator. This is a relatively easy installation if you have basic experience with electrical work.
    Below is the transfer switch that I used (paid link).
    amzn.to/3fqqMNK
  • Авто та транспорт

КОМЕНТАРІ • 48

  • @dwightjtaylor
    @dwightjtaylor 3 роки тому +1

    Simple and straight forward, I can see clearly now how a transfer switch works. Thanks for the demonstration in folksy terms.

  • @tayninh69
    @tayninh69 Рік тому

    Very good video, easy to follow and I like the way you presented the install without a lot of nonsense. JOB WELL DONE.

  • @lindaherring9034
    @lindaherring9034 Рік тому

    Thank you so much for your video! It saved a lot of heartache and frustration for us!

  • @mikegx2220
    @mikegx2220 7 місяців тому

    Outstanding DIY for Class C Motorhome. I have and continue to search for frecken hours, and yours are great. Tks

  • @christopherbradley5575
    @christopherbradley5575 3 роки тому +1

    Great video! Answered all my questions.

  • @ejthebus1355
    @ejthebus1355 Рік тому

    Great video, I was able to determine from the link it will work with my shore and solar inverter setup, I do not have a generator. Ordered it and anxious for it to arrive.

  • @gregpatey6355
    @gregpatey6355 Рік тому

    Great video. its a nice, clean, simple vid showing the ease of installing a 30amp ATS unit...
    For those with a 50amp RV, the process is the same, but with one extra wire, of which a 50a ATS has the extra connection ready to accept the extra wire.... simple, but 50a wire is a lot stiffer wire to work with....
    I must say that replacing the entire power cord is easy enough, but far from the most economical way to solve the failed 30a plug... because it WILL fail again in the same manner.
    the better option would be to cut the plug off the end of the cord and install a new QUALITY 30a plug that has the ability to take a lot more heat before becoming damaged, which almost ANY of the commercial quality replacement plugs will do this.... OR, by installing a 50amp plug and then using an adaptor, which then, the adaptor becomes the "sacrificial" weak link, which is much cheaper to replace than the entire cord, and much easier to replace periodically than the plug on the end of the cord....

  • @MR_UNOoo
    @MR_UNOoo 2 роки тому

    Great video couldn't figure out why ac would work with gen set.......SOLVED

  • @parishskoolie
    @parishskoolie 3 роки тому +1

    Thanks for the video👍🏼
    We are building a school bus conversion here in Louisiana.
    Just ordered this transfer switch, the link you provided isn’t the same as the video but I trust it is the same quality.

    • @JackofAllMasterofNone
      @JackofAllMasterofNone  3 роки тому +1

      I just checked the link in the description and it is the one I used. It could either say TRC or Southwire on it, but it's the same.

    • @parishskoolie
      @parishskoolie 3 роки тому

      @@JackofAllMasterofNone
      Happy to hear that! I’m a southwire fan. Thanks again💚💛💜

  • @flyingvguy6833
    @flyingvguy6833 2 роки тому

    Thanks for the video. I have a question about a connection strategy. Everything is the same between shore power and the line inside, the only difference is with the Gen connection. The Gen is outside so a plug must be run to it. Now this would run from the plug( in this case a120/240 L type) to the Gen connection in the Tbox correct? I would plug it in, in an emergency and start it but without engaging the breaker on the Gen, then the Tswitch would still be on shore power until I engaged the breaker with a 30 sec wait time and the Tswitch would change feeds, correct.? Does this switch then detect the re-energizing of shore power and switch back or do you have to switch off the Gen first?

  • @theknausexperience7671
    @theknausexperience7671 Рік тому

    Thanks for the video!!!

  • @lance307
    @lance307 2 роки тому

    Is there a way to have the generator auto start after loosi shore power?

  • @Deadrabbits1
    @Deadrabbits1 11 місяців тому

    Can I use this with my ecoflow?

  • @djsarg7451
    @djsarg7451 4 місяці тому

    Most Automatic Generator Transfer Switches use AC coil that buzz - hum. I found only one company that uses DC coils that do not buzz and hum: SCO, they make both a 30amp the LPT30BRD and 50 amp Automatic Transfer Switches.

  • @bigjeep2195
    @bigjeep2195 2 роки тому

    Why would you want to run your gen if your plugged in?

  • @gissellelopez5808
    @gissellelopez5808 Рік тому

    Does mounting position Matter? Label states CAUTION do not mount with face Down (Parallel to Earth).

  • @reddeerrebelrc6674
    @reddeerrebelrc6674 2 роки тому

    do I need to disconnect batteries?

  • @fabiangomez357
    @fabiangomez357 3 роки тому

    do all RV's that have an onboard generator automatically have a transfer switch? Also if you have a 50amp shore power plug because your RV is 50amp does that mean you probably have, or have to have a 50amp transfer switch if you plan on installing/replacing one? And finally if you install a surge protector, would it need to be installed including the generator transfer switch? thanks.

    • @JackofAllMasterofNone
      @JackofAllMasterofNone  3 роки тому

      A lot of RVs do not have a transfer switch. To run on generator you must plug the shore power cord into the generator. If you installed a whole RV surge protector, you would install it right where the power enters the distribution box, after the transfer switch.

  • @jessenovotny4183
    @jessenovotny4183 Рік тому

    I have a massive solar battery bank that I want to power the transfer switch instead of a generator. I have a generator but it will charge the batteries instead. If I want the switch to maintain shore power even if there is a current from the battery bank ("generator side"), can I just switch them? Plug the shore power in the "generator line" and run the battery bank to the "shore line"?

  • @sheliahlee4972
    @sheliahlee4972 2 роки тому

    I have a question I’m not sure if you’ll be able to answer. I have a transfer switch with a know and it appears to have broken should I completely replace or is there a way to repair?

    • @JackofAllMasterofNone
      @JackofAllMasterofNone  2 роки тому

      For the price, I would probably just replace it. They have contactors inside that can be replaced if that is the problem but it's not much more to just replaced the entire transfer switch

  • @rickmartel7119
    @rickmartel7119 Рік тому

    Good video. I have a generator and an inverter for my solar panel system...do you know of a transfer switch that will handle all 3 (shore, generator, inverter) sources?

    • @jessenovotny4183
      @jessenovotny4183 Рік тому +1

      you would need 2 transfer switches OR use the generator to top off the batteries when they're running low and solar isn't keeping up.

  • @briizcustoms9543
    @briizcustoms9543 Рік тому

    So it’s fine to have the generator in that port? The CO won’t seep into the RV? I’m
    Confused on why people mount them on the bumper and what not instead of the under section.

    • @JackofAllMasterofNone
      @JackofAllMasterofNone  Рік тому +1

      This is where the generator is mounted from the factory. It has an exhaust pipe that is routed out the side away from the RV. Usually they are on the bumper because the RV did not come with one and there is no place or easy way to put it under the RV

  • @robertrozzell6770
    @robertrozzell6770 2 роки тому

    Is that the only way the switch can be mounted? I need mine to mount horizontal.
    I'm fitting this transfer switch into a class a motorhome that has a simular but different oem switch

    • @ChrisTheMobileMechanic
      @ChrisTheMobileMechanic 2 роки тому

      Mounting position does not matter. I have one in my Semi, Laying flat on the floor and horizontal to fit my space and needs

    • @robfranke1
      @robfranke1 11 місяців тому

      You need to ck with the mfg. Some say DO NOT LAY FLAT. I believe those are the bigger ones that have mechanical contractors

  • @rvrebuild
    @rvrebuild Рік тому

    wouldnt that make the long cord that hooks to main power energized as well ?

  • @PatriciaMoyerShadel
    @PatriciaMoyerShadel 4 місяці тому

    Hoe do you open the box?

  • @lance307
    @lance307 Рік тому

    How does it know when to start the generator automatically after loosing shore power. That is what I'm confused on

    • @JackofAllMasterofNone
      @JackofAllMasterofNone  Рік тому

      This doesn't automatically start the generator

    • @lance307
      @lance307 Рік тому

      @@JackofAllMasterofNone what kit would I need with the ATS to sense it to auto start?

  • @thebass999
    @thebass999 2 роки тому

    will it work with an inverter instead of generator?

    • @JackofAllMasterofNone
      @JackofAllMasterofNone  2 роки тому

      Yes

    • @thebass999
      @thebass999 2 роки тому

      If both power sources are on which one will be selected? Which one is default - has priority? Thanks.

  • @aa999xyz
    @aa999xyz Рік тому

    why not just replace the plug on the shore power power cable

  • @zerohour7634
    @zerohour7634 Рік тому

    No need to replace the whole cord. Get a cord cap and cut the plug head off. Strip wires and install new cord cap. very simple. much cheaper.

  • @robertdickinson9837
    @robertdickinson9837 3 роки тому

    I don't agree with your comment about your plug being loose from using them a lot. The reason for this is the receptacle more than the plug. The receptacle provides the tension on the male plug. This tension can weaken over a period of time due to heat from multiple usage of the plug and high amperage usage. Using more than 80% of the capacity for long periods of time will cause this. Some male plugs allow you to open the pin which will put more tension on the connection. When you plug into a receptacle it should be a tight fit. If not there is a problem or there will be.

    • @JackofAllMasterofNone
      @JackofAllMasterofNone  3 роки тому

      You misunderstood what I was describing I think. The male plug pins will actually start to separate from the wire inside of the plug and resistance will increase and higher resistance will cause heat, which could lead to a meltdown or fire. This has nothing to do with the recepticle.

    • @robertdickinson9837
      @robertdickinson9837 3 роки тому

      @@JackofAllMasterofNone Your male plug gets like that either from the heat generated from the pins not making good contact with the receptacle (high resistance) or continued high amperage use. There is resistance between the two surfaces and this is what causes heat which melts the rubber. If you tear the rubber plug apart the connection inside will probably be good.

    • @JackofAllMasterofNone
      @JackofAllMasterofNone  3 роки тому +2

      @@robertdickinson9837 I did cut apart the plug. The problem was inside of the male plug. You could wiggle the male pins which were obviously loose. Stop trying to argue with me about this. I know exactly what I'm talking about. Thanks.