Low pressure on a Vaillant ecotec combination boiler F22 fault code

Поділитися
Вставка
  • Опубліковано 20 сер 2024
  • How to top up the pressure on your Vaillant boiler
    How to fix a Vaillant boiler Fault code F22
    What is a Vaillant F22 fault code

КОМЕНТАРІ • 122

  • @moynhaq7381
    @moynhaq7381 8 місяців тому +17

    Suddenly realised the water wasn't heating up, checked the boiler & the pressure was 0.4, didn't know what to do.... Watched your video, it was clear as crystal & just corrected the pressure.... Bobs not my uncle but the water is hot again. Thanks for your wonderful video.

  • @mjalondon413
    @mjalondon413 7 місяців тому +5

    Brilliant video, easy to understand and just the essentials. My neighbour had this emergency at 6am, she was freezing cold and needed to go to work, I was not familiar with her boiler but you helped me fix it in minutes ! And saved her calling out an engineer, additional days being cold and the cost. I've taught her what to do in future too ! Thanks so much !

  • @MarieKeiser
    @MarieKeiser Місяць тому +1

    David Wells, thank you a lot for this video... It happens this week-end, I have not emergency number at hand, anyway, my understanding of English spoken is not great, yet, and even for Scotland, right now, the weather currently is pretty cold, 12 degres Celsius, 53 Farenheit today so again, thank you from my cats and me...

  • @nickdavies1606
    @nickdavies1606 5 місяців тому +1

    Thanks so much for sharing this. Super clear video. Woke up this morning with no hot water and no heating and feared the worst. Watched your video and all fixed! Awesome - thanks!!

  • @boyfrogger5693
    @boyfrogger5693 7 місяців тому +1

    Had this issue and read the manual which made it seem very complicated! Your video really simplified this and helped sort the issue and get hot water back, thank you!

  • @annramcharan-xi4jv
    @annramcharan-xi4jv 7 місяців тому +1

    Thank you very much! With your very helpful step by step guidance video, I solved my boiler issue in 5 minutes & I’m warm & toasty now. Cheers🙌🏼

  • @jasonengland4032
    @jasonengland4032 8 місяців тому +2

    You actually are a hero right now my autistic child wanted a bath and it was cold so problem sorted !😊

  • @johnboy5736
    @johnboy5736 4 місяці тому

    Hi Dave Magic.!!!!
    Done topped up within 5 seconds.
    You are a gentleman. Thanks for your time and effort to share your help and experience. John

  • @alexxv.1519
    @alexxv.1519 8 місяців тому +1

    Finally one perfectly concise and clear video. Thank you!

    • @davewellsheatingengineer
      @davewellsheatingengineer  8 місяців тому +1

      Thank you so much
      Please like and subscribe so you get notifications when I upload more info on the Ecotec boiler

  • @maaxsandher
    @maaxsandher 8 місяців тому

    Thank you very much!! We solved our problem here in Spain, same machine, same problem, same solution!! You’re the best!

    • @davewellsheatingengineer
      @davewellsheatingengineer  8 місяців тому +1

      fantastic... anytime you need me to pop over to Spain and service your boiler just say the word 😊

  • @kevingraham2733
    @kevingraham2733 5 місяців тому +1

    Thanks for the great help, had the same issue, no water pressure, did what you showed and got boiler working, top man.

  • @user-mw9gb8xx2m
    @user-mw9gb8xx2m 7 місяців тому +1

    Thank you. I surprised myself. Easy to understand. Problem Solved in minutes.

  • @PulsePure
    @PulsePure 7 місяців тому +1

    Thanks for your video! Saved us from a freezing cold day

  • @kaleltom
    @kaleltom 7 місяців тому +1

    Thanks. Just saved my partners parents for a bit until the plumber comes later to check for a leak.

    • @davewellsheatingengineer
      @davewellsheatingengineer  7 місяців тому

      Thank you, good luck with your leak.. check around radiator valves.. it really doesn't have to be much for the pressure to drop

  • @simoselfsky7101
    @simoselfsky7101 5 місяців тому +1

    Thanks so much. Best video on UA-cam

  • @oksanahavrushchyk2259
    @oksanahavrushchyk2259 4 місяці тому

    Thank you so much for sharing . Appreciate it so much! Having this problem now! Clear and easy to understand

  • @VlogAcademyUK
    @VlogAcademyUK 8 місяців тому +1

    You star you!! Saved my bath tonight 🎉

    • @davewellsheatingengineer
      @davewellsheatingengineer  8 місяців тому

      Love the kind comment.. definitely need a hot bath 🛀 on a day like today brrr

  • @MJMelodiesYT
    @MJMelodiesYT 3 місяці тому +1

    Thank you saved the day

  • @user-lv1mo7rb8r
    @user-lv1mo7rb8r 9 місяців тому

    Fantastic video thanks! Clear, consise and straight to the point

  • @mariawood2467
    @mariawood2467 11 місяців тому +2

    Very easy to follow. Thanks for that! 😊

  • @markbouchachi1235
    @markbouchachi1235 9 місяців тому +1

    It was very helpful and well explained , thank you very much for that.

  • @carolbelarmino
    @carolbelarmino 7 місяців тому

    Thanks for saving our lives!

  • @LucyBunn
    @LucyBunn 10 місяців тому +1

    Thanks for this video, nice and simple steps.

  • @aaronhooper1110
    @aaronhooper1110 7 місяців тому

    Thank you Mr. Wells 👍🏻

  • @kingdomsy7608
    @kingdomsy7608 5 місяців тому

    Hello. Your video is clear. I did the same thing and nothing change. I don't know what can I do

    • @davewellsheatingengineer
      @davewellsheatingengineer  5 місяців тому

      I would suspect a pressure sensor fault or fill valve fault.
      Call an engineer to repair

  • @peterclements7458
    @peterclements7458 Рік тому +3

    Nice and clear, thankyou 👍

  • @solomononuorah3356
    @solomononuorah3356 9 місяців тому +1

    Thank you for this easy steps to follow

  • @stephenthompson1449
    @stephenthompson1449 9 місяців тому +1

    Thanks mate massive help

    • @davewellsheatingengineer
      @davewellsheatingengineer  9 місяців тому

      I never thought my little video would help so many people.. hope you have a good warm weekend 😊

    • @stephenthompson1449
      @stephenthompson1449 9 місяців тому

      @@davewellsheatingengineer well it has so keep at it Dave, seems a very simple video but it's assures so many. Thanks

  • @theelkhill4424
    @theelkhill4424 9 місяців тому +1

    Hi David great video thank you

  • @kleingti
    @kleingti 11 місяців тому +1

    Lovely video mate. Thanks

  • @Nikaustr
    @Nikaustr 5 днів тому

    Thanks mate.

  • @prisilliatayod
    @prisilliatayod 9 місяців тому +1

    life saver!

  • @joshuajethro
    @joshuajethro 19 днів тому

    Thank you

  • @barneyrow
    @barneyrow 8 місяців тому +1

    Thanks so much!

  • @br164
    @br164 4 місяці тому

    Thanks!

  • @stephent11
    @stephent11 3 місяці тому +1

    Thanks David. How do you reduce the pressure if you overfill?

    • @davewellsheatingengineer
      @davewellsheatingengineer  3 місяці тому

      Hi
      Either find a drain point or vent a radiator keeping a jar or something under it

  • @gilbertopires3099
    @gilbertopires3099 9 місяців тому +1

    Thanks
    Help full!!!
    🙏🙏🙏

  • @Marinda2610
    @Marinda2610 7 місяців тому +1

    What do I do if there is no white levers to twist open and close. Seems they removed it from our boiler?

    • @davewellsheatingengineer
      @davewellsheatingengineer  7 місяців тому

      does your boiler have a flap down door as in the video?

    • @Marinda2610
      @Marinda2610 7 місяців тому +1

      @@davewellsheatingengineer yes it’s exactly as in your video

    • @davewellsheatingengineer
      @davewellsheatingengineer  7 місяців тому +1

      sounds like someone has removed them, you can buy them, but for safety probably best to call a heating engineer to pop a couple on for you@@Marinda2610

  • @JoWhiterod
    @JoWhiterod 8 місяців тому

    This is really useful, thanks. When I open the valves to top up my water pressure water comes out at the point that the silver flexible pipe meets the valve. Am I doing something wrong?

  • @ben87
    @ben87 9 місяців тому

    So helpful, thank you!

    • @davewellsheatingengineer
      @davewellsheatingengineer  9 місяців тому +1

      Thank you, please subscribe, I'll be doing some more on Vaillant efficiency.

  • @hassantoufayli3234
    @hassantoufayli3234 5 місяців тому +1

    Hi, I have a valiant eco tech that keep coming up with water pressure fault.
    British Gas have been 3 times
    First time they replaced the inverter valve as it was leaking but this didn’t solve the problem, 3 weeks later I called them again and they replaced the pressure sensor and few weeks later had the same problem so I called them again, they came and changed the pressure settings so i don’t have the f75 fault but again few weeks later the issue reappeared.
    No visible water leaks around the house or any damp patches etc.
    What else could it be ? Appreciate your help 😃

    • @davewellsheatingengineer
      @davewellsheatingengineer  5 місяців тому

      Hi
      I assume your boiler is losing pressure (or at least the display is saying it is)
      Does your boiler have a pressure guage on the front? If it does does it read approximately the same?
      F75 pressure can not be adjusted, it is what it is..
      The causes of F75 are leaking pipes, radiator valves and joints, it doesn't have to be much to reduce the pressure low enough for the boiler to go to fault to protect itself.
      Check all your radiator valves for any signs of leakage, this doesn't have to be wet but sometimes shows a crusting around the valve.
      It can also be a leaking Auto air vent in the boiler.
      It can also be a pump inside the boiler starting to fail.
      The boiler needs to see that it had enough pressure in it before it does anything, if not you will get f75.
      If it says there is enough pressure it will then operate the pump, the pump should generate an additional .3 of a bar pressure, if it doesn't it will fault to f75.
      Get a good vaillant specialist or call Vaillant (or me if I'm in your area lol)
      Best wishes

  • @dinger40
    @dinger40 11 місяців тому +1

    thanks👍

  • @daddysimunek
    @daddysimunek 4 місяці тому +1

    Same problem with the unitower model, somebody can help? Impossible to find the 2 knobs 😢

  • @togce
    @togce 6 місяців тому

    Our boiler is a ecotec plus and it doesn't have those white valves underneath the boiler, instead what we have is a filling loop upstairs next to the immersion heater. An engineer installed it and taught me how to do it, I've done it many times before but this time it's not doing anything when I turn the screw on the filling loop metal pipe. Any ideas why it's not working this time?

  • @omarsuarez2444
    @omarsuarez2444 4 місяці тому +1

    Mines only got one valve and cant find other one

  • @nexionaut
    @nexionaut 10 місяців тому +1

    Top man!

  • @loggie1971
    @loggie1971 4 місяці тому

    I am doing that but the boiler keeps dropping water won't stay in the tank

  • @CindyPaul
    @CindyPaul 8 місяців тому +1

    Mine is on a 1.7 is that a problem oh my I hope I didn’t ruin my boiler

  • @stephenwright2056
    @stephenwright2056 8 місяців тому

    Don’t know if you can help David,but twice now my boiler has failed to come on,but the strangest thing is that no water comes out of my hot tap (even cold water)not even a drip,have you come across this problem before?.Then all of a sudden i have water coming from the hot tap and the boiler works without doing anything to it after maybe one or two hours.We have very low water pressure in the the water main outside 1.6 bar to my water meter in my driveway.Could it be that if there’s a problem (like a water leak)and the mains pressure drops below the required pressure this would stop the boiler operating.It’s very strange especially the fact that no water either hot or cold comes out of the hot tap.Have you come across this problem before.

    • @davewellsheatingengineer
      @davewellsheatingengineer  8 місяців тому

      I assume this is just the hot taps, if so one of the valves I show in the video is on the on position, it will be the righthand valve make sure it is turned to the off position

    • @stephenwright2056
      @stephenwright2056 8 місяців тому

      @@davewellsheatingengineer It’s not the refill pipe that is the problem,the problem is that when the boiler doesn’t work,no water goes through it to the hot taps not even a drip all my hot taps in my house are completely dry.I think it might be because of the pressure in the water main as after a while 1 or 2 hours water appears at the taps and the boiler works.Maybe because the pressure has gone up in the water mains.I have spoken with the guy who services the boiler and he’s not sure.Would the water pressure to the boiler cause this?

    • @davewellsheatingengineer
      @davewellsheatingengineer  8 місяців тому

      @@stephenwright2056 the refill valve on the right is a diverter, it diverts water from the main supply that usually goes through your boiler to filling topping the pressure up, it is very likely this valve has either developed a fault or been left in the on position.
      Incoming water pressure would affect hot and cold.. yours is just hot

    • @stephenwright2056
      @stephenwright2056 8 місяців тому

      @@davewellsheatingengineer Them valves haven’t been touched they are in the off position.They are not the problem,the boiler simply doesn’t turn on and no water (and being the boiler isn’t on it would be cold )is in the hot taps no drips or any water at all.Then a bit later (this time 1 or 2 hours) the boiler starts up.I think it’s the water pressure from the cold water main that’s got reduced pressure and that pressure isn’t enough for the boiler.I have 1.6 bar at my water meter,i suspect that the water pressure is reduced possibly because of a leak or reduced pressure from down the pipeline.Because even if the boiler doesn’t work i should still get cold water through the hot taps.Thanks for your interest.Do you know if the water pressure isn’t enough would i still get cold water through the boiler to the hot taps.

    • @davewellsheatingengineer
      @davewellsheatingengineer  8 місяців тому

      @stephenwright2056 a boiler doesn't need to be on to have water flowing through it to the taps.
      Ask when did this start
      May I suggest you go to the boiler, turn the righthand fill valve on and off a few times whilst having a hot tap open

  • @somethingnorhing4920
    @somethingnorhing4920 10 місяців тому

    Hi David,
    My valillant eco Tec boiler 418 does not have a pressure gauge.
    How can I tell if the pressure is low without a pressure gauge.?
    The little screen does not display anything about pressure (unlike other videos I've seen).
    How can I check the pressure?
    Many thanks.

    • @davewellsheatingengineer
      @davewellsheatingengineer  10 місяців тому

      Hi your boiler is a 4 series, so does not come as a pressurised boiler, most are simply filled via a tank in a roof space (loft)
      So I shouldn't worry.

    • @somethingnorhing4920
      @somethingnorhing4920 10 місяців тому

      @@davewellsheatingengineer Bless you David for the quick reply. Much appreciate it.

    • @davewellsheatingengineer
      @davewellsheatingengineer  10 місяців тому

      No problem at all

  • @annachoudhury8248
    @annachoudhury8248 Рік тому

    Hi David, my combi boiler has lost its pressure 3 times now in the last 6 months, so roughly every 2 months very slowly. Today I noticed one of the valve to top up pressure is open and the other is closed, could that be a reason? I also noticed when we last topped up the boiler to 1.5 the boilers pressure went all the way up to 3 when turning on heating , but eventually lost the pressure slowly over 2 months. It’s causing me a lot of anxiety because I’m thinking is there a leak somewhere which can’t be detected.

    • @davewellsheatingengineer
      @davewellsheatingengineer  Рік тому +2

      If your boiler pressure goes to 3 bar or above, it will discharge some water to the outside. It is a safety device.
      Once these devices have operated they usually do not fully re seat themselves, so will probably need replacing.
      The issue of the system rising in pressure when the heating is on is an expansion vessel problem, inside your boiler you have a vessel that has a inner tube in it, this inner tube should be pumped up to around 1.1 bar in pressure and then tested.
      Vaillant boilers also have two pressure gauges, one is a clock face type and the other gives a digital reading, the one that gives a digital reading is operated by an electronic pressure sensor, these easily become blocked, this gives rise to similar faults.
      You need to seek a heating engineer to service your boiler. These issues can easily be resolved.

    • @annachoudhury8248
      @annachoudhury8248 Рік тому +1

      Thank you David for the quick reply! I’ll get someone to have a look at it. 😊

    • @davewellsheatingengineer
      @davewellsheatingengineer  Рік тому

      It may be worth having a Vaillant fixed price repair and service, if it is an older boiler.

    • @annachoudhury8248
      @annachoudhury8248 Рік тому +1

      It’s a council property, they do come and check once every year, it has been a problem for the last 6 months. Hopefully they’ll come and fix it soon.

  • @Metco81
    @Metco81 6 місяців тому

    my vaillant eco tech pro 236/5 from 1.3 bar cold rise to 2 bar when heating is on.Do i have to leak a radiator to reduce pressure or is it ok? The boiler heats 9 radiatos for about 110square house.

    • @davewellsheatingengineer
      @davewellsheatingengineer  6 місяців тому

      1.3 rising to 2bar isn't awful.
      I would leave it at that but get a heating engineer in when you can to check the expansion vessel pre charge and also if the system needs an additional expansion vessel (all depends on volume of the system but a good engineer will work this out )

    • @Metco81
      @Metco81 6 місяців тому

      @@davewellsheatingengineer thank you very much.The vessel was pumped to 1.5 bar before 2 months. I leave it as you adviced me.

    • @davewellsheatingengineer
      @davewellsheatingengineer  6 місяців тому

      @Metco81 did they empty the expansion vessel and leave it open when testing and recharging the pressure?
      It must be done like this.

    • @Metco81
      @Metco81 6 місяців тому +1

      @@davewellsheatingengineer yes he has drained the water inside and then pumped.

    • @davewellsheatingengineer
      @davewellsheatingengineer  6 місяців тому +1

      @@Metco81 check with you engineer.
      May need additional expansion

  • @the1jxk
    @the1jxk 9 місяців тому

    I’ve turned the valves but I don’t hear any noise

  • @stephengodsmark4353
    @stephengodsmark4353 7 місяців тому +1

    ecotec sustain and there are 4 values under the boiler. don't know which to open. not clear at all. so calling the engineer.

    • @davewellsheatingengineer
      @davewellsheatingengineer  7 місяців тому

      Yes the sustain will have a separate filling loop, usually a braided flexible pipe near the boiler with valves either end.
      The principal is the same though

  • @Scott-cs7ew
    @Scott-cs7ew 2 місяці тому

    Am I the only one who doesn’t have any of these valves I literally have nothing just pipes 🤷‍♂️

    • @davewellsheatingengineer
      @davewellsheatingengineer  2 місяці тому

      Your boiler probably doesn't have the drop down door on the front

    • @Scott-cs7ew
      @Scott-cs7ew 2 місяці тому

      @@davewellsheatingengineer it does have the drop down door there’s just no valves or nothing to turn it was only installed last year

  • @ervisbardhi9613
    @ervisbardhi9613 3 місяці тому

    Is not working for me is staying still

  • @majhus6766
    @majhus6766 9 місяців тому +1

    Mines 10 times a day

    • @davewellsheatingengineer
      @davewellsheatingengineer  9 місяців тому +1

      Then you really need this looking at, you either have a leak or you pressure relief valve is running, take a look outside ( usually behind the boiler, a small pipe (15mm) may be dripping or in your case running, call a heating engineer, continual fresh water entering your system will corrode the metals in your system causing a lot of expensive damage. a call now could save you a lot of money.

    • @davewellsheatingengineer
      @davewellsheatingengineer  9 місяців тому

      Was it running or dripping?

    • @majhus6766
      @majhus6766 9 місяців тому

      @@davewellsheatingengineer running,,,only way to get hot water is to keep it on,,have a bath then turn it off to stop it running outside
      I’m a sparky,,so know a bit ,,got it booked in for 7 December

    • @davewellsheatingengineer
      @davewellsheatingengineer  9 місяців тому +1

      @@majhus6766 May be that it will be worth looking at a Vaillant fixed price repair, you could be looking at multiple parts, expansion vessel, pressure relief valve almost certainly, a fixed price repair could see you better off.. I believe its around £300 and they would be with you in a couple of days.

    • @majhus6766
      @majhus6766 9 місяців тому

      @@davewellsheatingengineer will they be giving any warranty with that ,,say at least 6 months problem free ,, had the old vailant boiler with the 2 spinning nozzle controls before this one ,,20 years problem free apart from occasional minor pressure issues,never serviced ,,beautiful machine 👍🏾

  • @Tipsi89
    @Tipsi89 8 місяців тому

    Thank you