Electric Showers: "How to install the T80Z Fast-Fit and replace the T80xr" video from Triton Showers

Поділитися
Вставка
  • Опубліковано 15 кві 2012
  • Triton Showers T80 Electric Showers - www.tritonshowers.co.uk/showe...
    A short video showing how to install the T80Z Fast-Fit and replace the Triton T80xr
    If you've ever struggled to replace an electric shower due to pipe and cable positions, then the T80Z Fast Fit is the shower for you.
    It has 8 water entry points; top, back, bottom and side entry on the left, and the same on the right.
    And 6 electric entry points; top, back and bottom on the left and the same again on the right. This makes it a hassle free, fast fit every time.
    It's ideal for new installations and perfect for replacing most existing showers.
    Providing the existing electric supply complies with the relevant safety regulations, and the water supply is adequate, you can fit a T80Z Fast Fit with the same kilowatt rating as the old shower, in no time at all.
    Let's see just how quick and easy it is to replace the T80XR with the T80Z Fast Fit...

    First make sure the electric and water supplies are isolated.
    Now unscrew and remove the cover.
    Test to check that the electric supply is isolated before removing the bottom trim.
    Here the water enters the unit from the rear on the right and the electric also enters from the rear on the right.
    Disconnect the supply cable.
    Then disconnect the water supply.
    Remove the wall fixing screws and remove the shower from the wall.
    Now for the T80Z Fast Fit.
    Take off the bottom trim plate and fit the top pipe entry trims.
    Water connection is required on the right so adjust the Swivel Water Inlet to suit.

    Electric connection is required on the right; so loosen the retaining screw on the Swing Fit Terminal and move it over to the right hand position.
    Now secure in place by tightening the retaining screw.
    Turn the elbow anti-clockwise through 90 degrees to match the inlet on the T80Z Fast Fit.
    Locate the inlet fitting on to the water supply.
    It's a perfect match; the new shower covers the existing fixing holes.
    Check the back plate is level and mark the new wall fixing points.

    Next remove the unit and drill and plug the new holes.
    Fit a nut and olive to the Water Inlet.
    Place the unit back on the wall and connect it to the water supply.
    Then screw the back plate to the wall.
    Fully tighten the water connection, and turn on the water to check for leaks.
    Connect the supply cables to the terminal blocks making sure that the connections are fully tightened.
    Now fit the bottom trim plate.
    Clip the power indicator light into the front cover.
    And make sure that the controls are correctly aligned.
    Fit the cover and secure it with the 3 fixing screws.
    Finally, connect the hose to the unit, turn on the electric supply and commission the shower on a cold setting....
    ....now there's just the shower kit to replace.
    If you haven't already done so, remove the old kit from the wall.
    In some cases you can use the existing fixing holes for the new shower kit.
    Start by fitting the top fixing plate to the preferred height, using the existing hole if possible, then slide the bracket onto it.
    Now fit the showerhead holder, the soap dish and the hose retainer on to the rail.
    Fit the bottom bracket and fixing plate onto the rail, and align with the holes in the rail. Secure with the long screw.
    Next, guide the rail into the top bracket. The rail can be adjusted; in this case to line up with the original fixing hole. There may be times when a new fixing point is needed.
    Now screw the bracket to the wall.
    Fit the top...and the bottom trims, feed the shower hose through the hose retainer, fit the showerhead to the hose and finally place it in the showerhead holder,
  • Розваги

КОМЕНТАРІ • 48

  • @kumarpeirson5187
    @kumarpeirson5187 7 років тому +2

    Well, a few weeks back I took out an old Gainsborough shower and installed a T80Z fast fit. Had to move the electric cable to a new hole in the tiling, using a special tile drill bit. New case fixing holes as well. Otherwise pretty good. Needing a new gate valve in the airing cupboard, not a fault of the T80Z, challenged my compression joint skills but I managed.

  • @paulplumb1648
    @paulplumb1648 4 роки тому +27

    It baffles me as to why shower manufacturers can't get together and agree on a universal shower footprint. I'd settle for a manufacturer using the same footprint for all of their own showers. It's all very well being able to swivel water and electrical cables but the biggest problem is drilling new screw holes. I've seen gas pipes and other electrical cables running behind a shower unit. Personally if the screw holes aren't an exact match then it's tiles off. Those tiles may no longer be available. I think the manufacturer that standardizes shower footprints will save customers money and make it easier for installers.

  • @brianwitton5061
    @brianwitton5061 2 роки тому +1

    Best video I have seen on fixing a shower

  • @treestalktoo8117
    @treestalktoo8117 3 роки тому +2

    Great video. Let's hope it's as easy as it looks; this will be my first attempt at fitting a shower . . .

  • @wiganer
    @wiganer 4 роки тому +1

    New shower (triton Martinique) was stuck in its box for two weeks because I 👍😎👍😎👍👌didn't know how to get the nut and olive on, sorted the new shower straight away after seeing this video....thanks a lot.......brilliant

  • @funanimalsounds
    @funanimalsounds 3 роки тому +2

    Triton showers are a life saver

  • @Lorfarius
    @Lorfarius 4 роки тому +3

    Just had one of these fitted but the highest setting is luke warm water at best. Any ideas what can be done?

  • @manbahadurthapa2833
    @manbahadurthapa2833 Рік тому

    very helpful video

  • @crazypolishvegan7369
    @crazypolishvegan7369 8 років тому +1

    Thanks mate! :)

  • @thisaranilupul904
    @thisaranilupul904 5 років тому +1

    thank you ...

  • @jimtinamx5
    @jimtinamx5 Рік тому

    Just removed our old Aqualisa as it had given up, replaced it with this and it was basically a straight swap, no dramas, one thing I don't understand though is the power indicator light stays on even when not in use? Unless you isolate it at the pull cord of coarse.

  • @somethingelse4878
    @somethingelse4878 4 роки тому

    So took out a screw that holds the can, one that goes in to plastic.
    Put in back and its like on a spring, it won't go fully in and tries to come out.
    Any thoughts, I'm thinking air trapped in the hole
    There's no water or grease in there

  • @mccormhead1785
    @mccormhead1785 4 роки тому

    Ive measured my water pressure and it 11 litres per minute. So i know it fine for my t80z 8.5kw triton shower. Yet when I switch my shower to hot its just dripping.Ive swapped the heat exchanger and its still rubbish. Running out of ideas as ive cleaned the filter out and stripped all parts and cleaned. Is there a fix and if not what shower has same hole alignment that isnt the same shower haha.

  • @johnpatus
    @johnpatus 3 роки тому

    hope you can help can this replace my aging topaz t100i model many thanks :)

  • @mrbadger9920
    @mrbadger9920 5 років тому +2

    Why on earth is the long screw on the rail slotted? It’s 2018!

  • @philippope1
    @philippope1 Рік тому

    Hi on shower were water comes out there a small like blow pipe water comes out how do you stop it thank you

  • @anthony342
    @anthony342 5 років тому +5

    that bloody bottom screw can be a night mare when water is fed from the bottom .

  • @shawnmills9756
    @shawnmills9756 5 років тому +2

    What type of compression elbow is that where you can adjust the rotation????

    • @MRBP3D
      @MRBP3D 3 роки тому +2

      Any if you just back the nut off

  • @screen-protector
    @screen-protector Рік тому

    Fit an oten olef - the self tightening screw. That's what I've heard about 2:39 and can't hear it the right way. So, don't know what should I buy :(.

  • @peter-xn8xu
    @peter-xn8xu 8 місяців тому

    Is the nut and olive for the water inlet a part of the supplied shower package?. I am just a little concerned about this connection. Normally olives compress or 'dig into' a hard copper pipe to provide the water seal. Here the olive digs into the soft plastic. Seems to me that if that first connection attempt leaks, then you've written off the entire unit, as you'd never to get it to seal properly on the 2nd attempt. Are you allowed to fit JG Speedfit plastic push fit connectors instead?.

    • @TritonShowers
      @TritonShowers  8 місяців тому

      We don't supply the nut/olive no, we also wouldn't advise using a push fit as it will invalidate warranty, we state compression fittings only.

  • @philtowle4683
    @philtowle4683 9 місяців тому

    Thought I might buy as fast fit but my inlet elbow is soldered vertical.😢

  • @davidjeffreys9063
    @davidjeffreys9063 4 роки тому +4

    Always makes me laugh when they say "It's as easy as that", doesn't always work that way. I noticed the compression elbow had enough slack on it to pull it out a bit to enable the nut to be loosened off to turn it to the left, if you didn't have any play you might struggle to undo it

  • @johnsonpalakkal3621
    @johnsonpalakkal3621 5 років тому

    Electric heater is not working.connection is OK.is there any other settings.water is draining out while On and no heater works.

    • @TritonShowers
      @TritonShowers  5 років тому

      Sorry to hear of the issues you are experiencing. If water is draining out of the bottom of the unit, it sounds like the pressure relief device (PRD) may have activated. This is a safety feature and the PRD is designed to activate when there is a pressure build up within the shower. This is usually caused by some kind of blockage to the flow of water through the unit, such as debris, limescale build up of the shower head or a kinked shower hose. If the PRD has indeed activated, it will need replacing as they cannot be 'reset'. It will also be advisable to inspect the shower unit and accessories for any of the previously mentioned blockages which may have caused the PRD to activate.
      If you require further assistance, please call our service team (contact details on the Triton Showers website).

  • @patrickkeefe2691
    @patrickkeefe2691 10 місяців тому

    I have a Triton Ivory 4 . 9.5kw keeps going hot and cold , what is the best replacement model ?

    • @TritonShowers
      @TritonShowers  10 місяців тому

      We still sell the Ivory 4 model direct on our website www.tritonshowers.co.uk/ivory-4-electric-shower or you can find the Ivory 5 as a suitable replacement through local Homebase stores. It may be worth just checking the shower head is clear of blockages and the hose hasn't got a kink in it. Generally hot/cold issues will be due to low flow or flow restrictions.

  • @AllecsandraElle
    @AllecsandraElle 2 роки тому

    If the pressure valve fell ... I don't know what to call it. is there any danger

    • @TritonShowers
      @TritonShowers  2 роки тому

      We would advise for further help on this sending over your contact details and potentially some photos of the part to our technical department on technical@tritonshowers.co.uk from there we should be able to assist you. Kind Regards, Leon.

  • @somethingelse4878
    @somethingelse4878 4 роки тому

    We have a T70xr will this just fit with no rewiring or piping and are the fixing holes the same
    Anyone know of a replacement for the t70xr that fits with no rewiring, pluming or holes
    Just a pop on

    • @batmangoddam5999
      @batmangoddam5999 2 роки тому

      Did this shower make a replacement for your t70xr

    • @TritonShowers
      @TritonShowers  2 роки тому

      @@batmangoddam5999 The T80Z Fast-Fit (or the T80 Pro-Fit) would replace a T70XR model. Kind regards, the Triton Online Team

  • @Sailorboy1980
    @Sailorboy1980 3 роки тому

    Can this replace the triton madrid 2 unit??

    • @TritonShowers
      @TritonShowers  3 роки тому

      Hi Tony. The water supply compression fitting will require turning through 90° to accommodate the Fast-Fit's horizontal inlet but other than that, the T80Z Fast-Fit is a relatively straightforward for a Madrid 2 unit. Hope this helps.

  • @Charlie.93
    @Charlie.93 10 місяців тому

    Ive just had this exact shower fitted less then a week ago and its constantly dripping?

    • @TritonShowers
      @TritonShowers  10 місяців тому

      If the shower is constantly dripping water we'd advise contacting our service team on 02476 372222 to discuss and potentially arrange a service repair.

  • @AbdulKareemAbdulRahman
    @AbdulKareemAbdulRahman 5 місяців тому

    my triton shower button doesnt work. But the ceiling pull cord turns water on but it isn't heated. any ideas? all fuses working normally

    • @TritonShowers
      @TritonShowers  5 місяців тому

      The water not heating can be caused by low water pressure, the shower will be using a pressure switch for the elements to go on. This requirements will be dependant on the kW rating of the shower. As for the on/off not working this could be an issue with the switch itself or the unit not being flat to the wall causing misalignment with the button/switch. If the installation doesn't appear to be the problem we'd recommend contacting our service team on 02476 372222.

  • @octavianionutvladu516
    @octavianionutvladu516 2 роки тому

    What Size îs a cold elbow?
    15/22 elbow?

    • @TritonShowers
      @TritonShowers  2 роки тому

      Hi, it is a 15mm compression fitting. Kind Regards, Leon.

  • @berkayultraslan1
    @berkayultraslan1 4 роки тому +6

    Probably the worst electric showers I've ever worked on, this product is better put in a rocket and sent into outer space

    • @TritonShowers
      @TritonShowers  4 роки тому

      Sorry to hear of your dissatisfaction with our T80Z Fast-Fit model. If you could provide some further details of what is causing this for you, we would welcome the opportunity to advise and assist as appropriate. Kind Regards, the Triton Online Team.

    • @ajoyrosle5446
      @ajoyrosle5446 3 роки тому

      😀😀😀

  • @evieemaya88
    @evieemaya88 10 місяців тому

    2:42

  • @mikerichardson7038
    @mikerichardson7038 6 місяців тому

    If you don't push the plastic wall plugs behind the tiles, you're liable to crack the tiles as you tighten the screws.