Revealed: Major Mistakes in Bosch IDS Heat Pump HVAC Installation Compromise Reliability

Поділитися
Вставка
  • Опубліковано 29 жов 2024

КОМЕНТАРІ • 127

  • @ATSNorthernMI
    @ATSNorthernMI 2 місяці тому +6

    Ive been watching your channel since you had maybe 20k subs. I watched you past 100k and still going. I love watching your content and took advice that I am wasting my talent working retail. I hate every day of my life here and want to change. I also started documenting my life as I turn around from being poor, broke, and miserable to doing what I love doing and telling my story along the way. Thank you again Mikey Pipes for all you do and I will continue to like and comment because you made a difference in my life.

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      Thank you so much for your feedback and your comment. I’m glad to see that you’re honest with yourself and want to do better for yourself and your family.

  • @Samlol23_drrich
    @Samlol23_drrich 2 місяці тому +5

    "I'm very observant "
    love it! You tell em'

  • @stevealoia
    @stevealoia 2 місяці тому +4

    A friend of mine had a Bosch. It was installed 2018 . 3 weeks ago the unit stopped running . Bosch tech support
    Told me the board is bad.
    The problem is there are no boards until October. So Bosch replaced the condenser unit under warranty. That shit is awesome.

  • @chadhayden6491
    @chadhayden6491 2 місяці тому

    Thanks for teaching for the ones that weren’t taught correctly

  • @Balticblue93
    @Balticblue93 2 місяці тому +10

    The system setups are by all intents and purposes way oversized, but the 5-ton outdoor condensers are also 4-ton capacity with a switch of a jumper to match the indoor 4-ton AHU units. The unit in the video was not properly set on the jumper to a 4-ton capacity to match the AHU. These items do work together by Bosch design, if set correctly.
    Also, the 3/4" lineset IS acceptable as an optional size, but 7/8" is the standard recommended on the 4-5-ton units. The brazing is horrendous and a cap missing that isn't a locking cap would be an install violation. Be it as it may, they did not properly set the jumper for 4-tons but that is still grossly oversized based on the size of the house shown in the video.
    No surge protection is another big factor that should be added along with proper drain pan safety switches and traps as mentioned. Bosch only produces two physical condenser units that work for an array of sizes. A 3-ton unit is also a 2-ton. This unit is a 4-5 ton based on the settings in the unit. The lineset length is fine based on the vertical run and TEL of the lineset and does not need to be replaced.
    I have sold and installed quite a few of these units and the client should be fine at 4-ton as the system will ramp up and down without short cycling. The 4-ton settings should be running at 54hz at full capacity unless it is limited by static pressure and the system is automatically reducing capacity.

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      Thanks for sharing your feedback

    • @ivancook1247
      @ivancook1247 2 місяці тому

      All true but you don't have to switch from 5 to 4 or 3 to 2 , doesn't make a difference bosch had ran a 5ton on there 2 ton coil

    • @ZERO-F2G-
      @ZERO-F2G- 2 місяці тому +1

      My Bosch trainer told me there is never a real reason to set that jumper lower. We have done 50+ Bosch systems, we set the switch to derate on the first few, have not since, My Bosch sales rep has told me the same, its there, but completely unnecessary.

    • @ivancook1247
      @ivancook1247 2 місяці тому +1

      @@ZERO-F2G- we do set the dip switch to run a colder coil for dehumidification

  • @brandenbock9685
    @brandenbock9685 2 місяці тому +2

    If you go to Bosch Quick Start Guide it has a table and on the 5 ton you can use 3/4, 7/8, or 1 1/8. Just can’t run out to max lengths if using 1 1/8”. Just like on the Bosch 18 seer you can have a 5-ton to a 3-ton air handler and you have an ahri match for that.

    • @throttlebottle5906
      @throttlebottle5906 2 місяці тому

      yes, it's in the condenser install manual, something like "piping limits".
      long lengths of 1-1/8" (or any) with rooftop condenser (any long vertical line-set that runs down building) would be bad for oil return, especially for an inverter that may never run at 100% or even close. we all know what no oil does, dead compressor. 😬

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      Just because you can do it does not mean you should do it. There’s a reason why the wedged end at the air handler and the condenser are 7/8 if they really didn’t care right they could’ve made it three-quarter.

  • @scottvolage1752
    @scottvolage1752 2 місяці тому +2

    Making the trades great again Mikey Pipes. #LoveBosch Smash that like folks. Smash it.

  • @Joseph-k5r
    @Joseph-k5r 2 місяці тому

    I don't like it when other people do crappy work and I take pride in mine but I do not understand any circumstances bad mouth another contractor. That is a sign of you bringing them down to make you look better. I don't feel the need to make myself look better. My work speaks for itself.

  • @brian2359
    @brian2359 2 місяці тому +3

    What a mess! Great way to show a customer how good a Bosch system can be

  • @grasscutter1963
    @grasscutter1963 2 місяці тому

    Mikey Mike that was a good video it’s different than all the others. I’ve watched you’ve always installing something or taking something out, but I’ve never seen you do one on troubleshooting, that was very fun watching it. Thank you.

  • @pringu
    @pringu 2 місяці тому +8

    National grid and PSEG are not vetting the contractors on the list and the contractors are taking advantage of the grant money to provide shoddy work.

    • @PipeDoctor
      @PipeDoctor  2 місяці тому +1

      You know it’s funny when we signed up or renewed our partnership this year they told us that we had to attend a mandatory installation class and to bring a flaring tool and a tubing cutter so they could show us how to flare for Douglas mini split installs. I’m like are you kidding me Block what is the 1990s this is 2024 we’ve automatic tools that do everything and you’re gonna I’ll teach you how to flare copper get the fuck out of here

    • @pringu
      @pringu 2 місяці тому

      @@PipeDoctorMikey fuc**** pipes

    • @pringu
      @pringu 2 місяці тому +1

      @@PipeDoctorthen the contractor tells you why are you complaining you got your system for free national grid paid. Sometimes better to pay for things. The whole system is terrible

    • @robd7365
      @robd7365 2 місяці тому

      It's not free ..you get a writeoff on your taxes... I believe you get %20 of the TOTAL project cost back

  • @danielracicot8310
    @danielracicot8310 2 місяці тому +1

    My understanding from bosch is suction can be 3/4 or 7/8. But liquid line has to be 3/8 no acceptions. I believe It even says that in manual. Will check tomorrow.

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      Even if you can do, it doesn’t mean you should do it. There’s a reason why the wedged connections at the air handler and the heat pump condensing unit are 7/8“

    • @danielracicot8310
      @danielracicot8310 2 місяці тому +1

      The install manual states you can. Read the destructions next time

  • @repairmonkeyservicegroup8795
    @repairmonkeyservicegroup8795 2 місяці тому +2

    I just installed one of these condensers and 2 days later had to change the thermostat because of something bleeding over, I was reading 7.8 volts on the yellow to common, 4.8 on brown to ground and that was enough to turn on the unit outside.

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      Yeah, you can’t use those nest. I often run into problems with the Bosch.

  • @HVACOG
    @HVACOG 2 місяці тому +2

    I tore out a 5 ton system that had a 3/4 refrigerant line. It had a nasty burn out. Of course we ran a brand spanking new 7/8 line to the new 4 ton system that was needed for the size of their house. Some people hahaha. Same thing using a 7/8 as a reducer at the bell swedge.

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      Yeah, some guys should not be installing HVAC equipment

  • @michaelshanahan9578
    @michaelshanahan9578 2 місяці тому +1

    Funny when you read the instruction manual from Bosch they allow 3/4 suction to be used on their 5 ton units....

  • @mr.stonerUDX714
    @mr.stonerUDX714 2 місяці тому +1

    gotta luv those HACKS!!!!!!!! Mikey F en PIPES!!!!!!!!!!!!!!!

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      Hacks keep bringing us stacks

  • @user-cz8do7xl8u
    @user-cz8do7xl8u 2 місяці тому +4

    My senses tell me that this was a 3 ton system. Along came Super Sales-Tech and sold them 2 Bosch systems to SAVE THEM from the NY-Clean Heat rebates!! Charged them crazy, took the rebate and threw that system in. Why spend $250 on the proper line-set, there's one there already and the customer will never know! Some say home owner do-it-yourselfers are bad. I go back on more systems installed by "pro's" than home owners.. Sheesh.

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      Absolutely it was a super tech but they needed the 5 tons in order to qualify for those stupid rebates. Let’s say it’s $2000 a ton you got 10 tons. That’s $20,000 right there bingo Ching installing this is what PSEG approved.

  • @jonwhite4755
    @jonwhite4755 3 дні тому

    Can i use the ecobee premium thermostat on a 5 ton Bosch heat pump IDS 2.0 system. Air handler and heat pump will be Bosch.

  • @detroitjohn4724
    @detroitjohn4724 2 місяці тому +1

    surge protector should be installed at exterior shut off box ? or inside the heat pump ? (on the board ?)

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      At the main panel, electrical service for the home or at the specific Appliance

  • @zacharypalczynski8450
    @zacharypalczynski8450 2 місяці тому

    Been watching Miney pipes since he started on the tube. I’m older than Godzilla ! As a sub

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      Thank you very much for your support and dedication to the channel. Are you subscribed to my other channels as well?

  • @citylockapolytechnikeyllcc7936
    @citylockapolytechnikeyllcc7936 2 місяці тому

    What a nutty bridge ! wonder how many collisions per day !

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      Yeah, it’s kind of crazy

  • @gregs9555
    @gregs9555 2 місяці тому +2

    Some people have no standards🙄. Seems to be more common than it used to be, what a mess.

    • @PipeDoctor
      @PipeDoctor  2 місяці тому +1

      Some people should not be installing HVAC systems and peoples homes

    • @gregs9555
      @gregs9555 2 місяці тому

      @@PipeDoctor Exactly, these homeowners pay a supposed professional, should get a job done right and not a garbage install. Could never leave a house knowing I did that.

  • @mingyima124
    @mingyima124 2 місяці тому +1

    Regarding the TP2 Plus units you received, I’m sorry to hear there were issues. It’s concerning that we haven’t received any communication from you in the past month, and it’s unlikely that our emails would end up in your spam folder. We have been eager to see the video and work together on this collaboration.
    Could you please provide the video link and any feedback you have? This will help us understand your experience better and address any concerns you might have.
    We value your feedback and are committed to resolving this matter. Thank you for your understanding, and we look forward to your response.
    BTW, I've left comments multiple times, but they seem to have been deleted. We need to communicate about this issue. Please let me know why this is happening.
    Best regards,
    Minnie
    Marketing, Mileseey

  • @scotts4125
    @scotts4125 2 місяці тому +2

    That house might be a bit humid with short cycling.

    • @potatolew4495
      @potatolew4495 2 місяці тому +1

      Not with the Bosch systems.

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      No, it’s an inverter, but it’s an oversize inverter. I would never install that that is just stupid.

  • @alannewsome1729
    @alannewsome1729 2 місяці тому +1

    If he would’ve hired Mikey it would’ve been done right the first time.

  • @flatfoot62
    @flatfoot62 2 місяці тому +2

    Mr Pipes where’s your son, Conor. He don’t post anymore on his channel. I miss his content. I hope everything is good with him.

    • @PipeDoctor
      @PipeDoctor  2 місяці тому +1

      Listen, creating content on a consistent basis isn’t easy and isn’t for everyone

    • @flatfoot62
      @flatfoot62 2 місяці тому

      @@PipeDoctor I wish him the best. You both work your asses off. I love both your content. Thanks for answering me. Take care. I’m a Long Island native from 11772.

  • @Spillmansgarage
    @Spillmansgarage 2 місяці тому

    I like the stickers! I wouldn’t have put them on that work though. 😂

  • @KrusherMike
    @KrusherMike 2 місяці тому

    Did I braze that low pressure line? Sweet mercy, that's why they just left me on the electronic and ventilation side. 😅

  • @throttlebottle5906
    @throttlebottle5906 2 місяці тому

    umm, the BOVA (condenser) units only come as 36K or 60K btu. with the 60K unit paired with BVA(air handler) of 48K btu, it will only produce 4 ton of output and compressor runs at lower speed(frequency) to accomplish 4 tons of output(peak). the same for other air handler sizes. (24/36K use 36K condenser) and (48/60K use 60K condenser).
    the line-set being undersized isn't great, but will probably squeak by since it should never ramp past 4 ton output anyway. I'm not sure of their strategy though. SEER may be a bit lower than rated(20) on that unit.

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      Thanks for sharing your feedback

  • @jamesg9936
    @jamesg9936 2 місяці тому

    It is much quieter after the new setup.

  • @markcotter2355
    @markcotter2355 2 місяці тому +2

    10 tons of ac! wow a mega mansion.

    • @potatolew4495
      @potatolew4495 2 місяці тому +1

      It was paired like that due to the heat function, not the A/C.

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      But it’s still a 5 ton 60,000 BTU unit

  • @salvhockey
    @salvhockey 2 місяці тому +4

    I like your new label, but I would have left your number also

    • @aperson9495
      @aperson9495 2 місяці тому +1

      I Agree with this... Not everyone is up on the QR code thing... There are plenty out there that would look at it and be like 'what am I supposed to do with this? Whatever... I'll call Petro...' My grandmother, if she still lived on LI (and was in your service area, which she wasn't), would not have a clue what to do with that sticker. She'd call Petro or Burt's reliable. Leave an alternate, non-technical option. Overall, there's nothing wrong with the new sticker, but leaving your phone number on it would be a really good idea.

    • @PipeDoctor
      @PipeDoctor  2 місяці тому +1

      Stay tuned I have another another sticker reveal being released soon

  • @freekyle1577
    @freekyle1577 2 місяці тому

    Nice hat on the dash

  • @StevenLaskowski-yj1ir
    @StevenLaskowski-yj1ir 2 місяці тому +4

    There is no way that house needs 10 tons 😂😂

    • @robertsmith2956
      @robertsmith2956 2 місяці тому

      Maybe they have 5 sub levels to hold up in after the crash.

  • @petertorressr7725
    @petertorressr7725 2 місяці тому

    What about a search protector

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      Yep, they need a surge protector

  • @kevinpearce3281
    @kevinpearce3281 2 місяці тому

    7/8” copper is impossible to bend so that’s why they used 3/4”

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      WRONG. WE BEND IT ALL THE TIME

  • @ThumperKJFK
    @ThumperKJFK 2 місяці тому +1

    Great job as always Mike 👍✌

  • @unknownvalor9755
    @unknownvalor9755 2 місяці тому

    Sadly come winter their power bill is going to be more than a house payment.

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      I don’t know about being more than a mortgage payments, but it will definitely be more than having a gas system

  • @joelmartin5316
    @joelmartin5316 2 місяці тому

    Was that in New Bedford?

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      No, this installation was is too good for that area

    • @joelmartin5316
      @joelmartin5316 2 місяці тому

      😂​@@PipeDoctor

  • @user-cz8do7xl8u
    @user-cz8do7xl8u 2 місяці тому

    You know, the scary part is the Mr.Cool boards look awfully similar to this board... 🤔

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      That reminds me I need to invoice Mr. Kule for that little commercial I did for them

  • @zacharypalczynski8450
    @zacharypalczynski8450 2 місяці тому

    Helllll na that house does not need 10tns. With inverter that’s a 8tn max, but hey use the gov to get that cheddar !

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      Yeah, but it’s stupid 10 tons. It’s pathetic.

  • @brian-ek1ec
    @brian-ek1ec 2 місяці тому

    17:50 maximum lenght of seal tight is? Why is the seal tight laying on the ground. Make the trades great.

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      I didn’t even notice the liquid tight

  • @gmard1
    @gmard1 2 місяці тому +2

    Nice job for 1 1/2 hours.

  • @Dustin-zk8nb
    @Dustin-zk8nb 2 місяці тому

    Your F.O.S

  • @nonamesplease8228
    @nonamesplease8228 2 місяці тому

    And he left without replacing the missing service cap

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      Yep, it shows you. I’m only human. I’m not a Superman.

  • @guytaniguchi
    @guytaniguchi 2 місяці тому

    You can have the best equipment but if the installation is shitty then it's no bueno.

  • @nickc6399
    @nickc6399 2 місяці тому +1

    I understand the sticker on the units for future reference for the home owners but I wouldn’t be putting my name on a shit install like that

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      I hear ya, but I mostly did it for the community. I love my new sticker.

  • @throttlebottle5906
    @throttlebottle5906 2 місяці тому

    who in the HEY did that braze job. gee, lets just ram too small a line in and apply big lumpy boogers around the perimeter. LOL

  • @ItsTheCostanza
    @ItsTheCostanza 2 місяці тому +7

    Whoever installed this tried to copy your style lol

    • @PipeDoctor
      @PipeDoctor  2 місяці тому +2

      Not even close

    • @Spillmansgarage
      @Spillmansgarage 2 місяці тому

      Let’s see your install videos!

    • @kain93
      @kain93 2 місяці тому

      lol he hasn’t even put his gauges on and see it it’s performing like it should lol 😂 he’s there to check that the unit is not coming off.. and that’s not the problem. 😂

    • @BlahBlah-em2ed
      @BlahBlah-em2ed 2 місяці тому

      Yup. No booties.

    • @potatolew4495
      @potatolew4495 2 місяці тому

      ​@kain93 , Mikey Pipes was there to diagnose why the unit was not turning ON!!
      Also, why put gauges on the unit if it was cooling and the line set is incorrect. It sure sounds like the homeowner will rectify the issue.
      Stick to whatever it is you do. Hopefully it is not HVAC repairs. 😂😂😂

  • @timothygingras6939
    @timothygingras6939 2 місяці тому

    Mikey, you left out a lot of information but that’s OK. You were there an hour and a half and your video is What? 20 minutes.

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      Exactly I was there for 90 minutes and during those 90 minutes I created 20 minutes of video.

  • @TheRAMBO9191
    @TheRAMBO9191 2 місяці тому +1

    🥃👍🏻

    • @PipeDoctor
      @PipeDoctor  2 місяці тому

      I can use a drink right now

  • @realestateservicessaleshea99
    @realestateservicessaleshea99 2 місяці тому +1

    PSE&G???😮😮😮
    Or unscrupulous contractor???

  • @remmymontana6775
    @remmymontana6775 2 місяці тому

    Not all trades people are racists

  • @steveblake8766
    @steveblake8766 2 місяці тому

    565th Thumbs uP