HOW TO INSTALL A THERMAL EXPENSION TANK ON WATER HEATER

Поділитися
Вставка
  • Опубліковано 16 вер 2024
  • Join me today as i bring a water heater up to code and show you how to install a thermal expansion tank!

КОМЕНТАРІ • 292

  • @saranjesse23
    @saranjesse23 3 роки тому +6

    Excellent job explaining the steps and why you’re doing what you’re doing! Thanks.

  • @avag1334
    @avag1334 4 роки тому +73

    Don't you need to check the air pressure in the tank to match the water pressure coming into your house?

  • @barryrosenthal7337
    @barryrosenthal7337 4 роки тому +28

    didn't ream the copper pipe after he cut it, didn't change that old shut off valve with a new better ball valve, didn't test water pressure to make sure the expansion tank matched with air pressure.

    • @wcsd9577
      @wcsd9577 3 роки тому +4

      and no dielectric unions, and used type M copper

    • @chrispinette8303
      @chrispinette8303 3 роки тому

      They are dielectric nipples coming out of heater

    • @forextrinitrader
      @forextrinitrader 3 роки тому +1

      @@chrispinette8303 do Rheem water heaters use dielectric nipples? I installing a AO Smith and the manufacturer says dielectric unions are required.

    • @forextrinitrader
      @forextrinitrader 3 роки тому +3

      He probably did it off camera, it hard to video everything thing when on a actual job.

    • @pipingdogtooth
      @pipingdogtooth 3 роки тому +1

      @@wcsd9577 How can you tell it's not type L or K?

  • @RoyBaty
    @RoyBaty Рік тому +1

    Old school. Thanks for showing how it's been done for 100 years. Too many videos show the new compression tools that most of us can't afford or the shark bite pieces that are expensive. This is cheaper and with a few plumbing tools and practice most of us can master this method. One thing, show us your soldering. Some people don't realize you need to heat the elbow, not the opening. When the entire fitting reaches the correct temperature the solder will be drawn all the way in.

  • @beaunhead
    @beaunhead 8 місяців тому +2

    Wish you would've shown the soldering... Great video, good detail and explanation

  • @strongsadventures
    @strongsadventures 5 років тому +3

    Thank you for taking your time to show this Tim. It is hard enough to do the Job fast and most important the right way so i will say this thank you for sharing how to do this. Ain't gonna be no leaks if you did it.

  • @timc1341
    @timc1341 2 роки тому +4

    Great vid Tim
    Expansion tanks are not required by code in florida unless the house is a "closed system" i.e. some sort of check valve or backflow preventer is in place inhibiting the expansion of the hot water back into the distribution system.

  • @5tr41ghtGuy
    @5tr41ghtGuy 3 роки тому +1

    Just what I needed to see today to get a new heater installed. Thanks so much for posting!

  • @fish4food0071
    @fish4food0071 Рік тому +9

    I call b.s. on the shark bites. They are built to last as long as your hot water heater and in most cases outlive a soldier joint. I have done home repairs and remodels. I have been called to dozens of pipe leaks that were failed soldier joints and only one leaking shark bite and it leaked due to pipe not cut true and or deburred. And you check your incoming pressure before you install your expansion tank so you can pressurize it to match.

    • @Grizzleback07
      @Grizzleback07 5 місяців тому +1

      I have them on several connections that are in the open and not a single leak. You HAVE to debur the pipe and cut it straight like you said in order for them to fully seat and make a good connection. These guys are stuck in the fittings of the 80's when they were not as good.

  • @pepelepew158
    @pepelepew158 4 роки тому +2

    Thank you.!!!!! This helped me out a lot. Awesome video again ty so much for taking the time and explaining it step by step.

  • @jgg204
    @jgg204 4 роки тому +13

    The water heater will fail well before 30+ year rated sharkbite ever will. And when the water heater fails, you just replace the sharkbite valve flex lines with it like you would a dishwasher or a washing machine. In and out replacement in less than 30 mins

    • @josem2468
      @josem2468 3 роки тому

      You hire a hack if they use Sharkbites. Only for homeowner use.

    • @jgg204
      @jgg204 3 роки тому

      @@josem2468 and this is a home, you moron

    • @garygray4664
      @garygray4664 2 роки тому

      Sharkbites are fine. I personally wouldn't use them right at a hot water heater but about 16-18 inches away would be better.

    • @grow8094
      @grow8094 2 роки тому

      I I am a plumber never use shark bites There’s way better stuff to use I agree with the guy make the video you don’t use shark bites If the homeowner wants to use one that’s his choice but if you’re paying someone to do a job they should do it right

    • @jgg204
      @jgg204 2 роки тому +1

      @@garygray4664 they are rated for 12" away from tank nipple

  • @rickjames6948
    @rickjames6948 9 місяців тому +1

    Check house water pressure. Adjust thermal expansion tank pressure accordingly. Do this with the hot water tank with zero pressure inside it. Don't want water pressure pressing into the thermal expansion tank fudging the thermal tank pressure.

  • @jamesrecknor6752
    @jamesrecknor6752 Рік тому +1

    Good teaching ability

  • @Honestandtruth007
    @Honestandtruth007 2 місяці тому +1

    Just Subscribed for your Expertise 👍👍

  • @keithcastleberry3993
    @keithcastleberry3993 4 роки тому +11

    Dont use shark bites but let's screw copper fittings to galvanized pipe to promote electrolysis. Nice.

    • @chrispinette8303
      @chrispinette8303 3 роки тому +4

      They are dielectric nipples with plastic cores

    • @pxxexxs
      @pxxexxs Рік тому

      He is using dielectric nipples he talks about the plastic in them.

  • @PetePuebla
    @PetePuebla 3 роки тому +3

    In my opinion I think you're right about securing it snugly. I don't think you have to use a wrench. You just need a good seal.

  • @johnblack2427
    @johnblack2427 5 років тому +8

    Good video how though it was more about the copper than the actual tank. Did you add air to the tank, and what is the pressure in the tank installed in relation to the pressure in the plumbing system?

  • @pj3p488
    @pj3p488 4 роки тому +4

    Sharkbites in earthquake zones, ok. UA-camr, DIY, and lazy plumbers love them. How often have I gone back to their work and removed the flexes because they went bad and started leaving black goo in their hot water? Quite often. Heater tip, if it has a plastic drain valve it is a crap heater.

    • @josem2468
      @josem2468 3 роки тому

      How true. Needs a full port drain valve.

  • @Gabester64
    @Gabester64 4 роки тому +1

    Thank you going to give it a try this weekend. helped out a lot.

  • @nikkogarcia7104
    @nikkogarcia7104 5 років тому +21

    You didn't charge up that
    expansion tank with air matching the pressure to the incoming water supply. That tank on there isnt doing anything useful without a proper charge.

    • @PLUMBINGWITHTIM
      @PLUMBINGWITHTIM  5 років тому +14

      I’m glad you guys mentioned this as I realize that I left this step out. I will be doing a follow up video about this critical step. Thanks for watching!

    • @darienlandry3244
      @darienlandry3244 4 роки тому

      Nikko Garcia those typically come precharged just saying

    • @coachmattc
      @coachmattc 4 роки тому +16

      @@darienlandry3244 Not enough. Needs to match the system pressure.

    • @brandonmunsin9310
      @brandonmunsin9310 3 роки тому +2

      lil tip, they usually always come pre charged @20lbs.. an easy way to figure out what to charge up too, pressure test the house , thtl be your # then use air compressor. never charge passed 80lbs. usually 50 is where it’s at.. yes most people don’t charge them, makes it pointless to have if not charged... anyways good vid! keep it up man, stay positive! im an commercial/industrial plumber. plumb everyday on big systems , an no matter what you do somebody will always have something to say lol everyone thinks they know it all, an most likely really don’t know shit ..wish people were more positive

    • @pipingdogtooth
      @pipingdogtooth 3 роки тому +1

      @@PLUMBINGWITHTIM Can you provide a link to the update?

  • @Unkdrefinest
    @Unkdrefinest 9 місяців тому +1

    It's code that you don't turn the tank upside-down through test it last longer having bleeder facing down.
    Yeah I know they have been doing it this way for over a hundred years, but a hundred years they all was backwards. You also supposed to check the water pressure to match the tank. Thanks Tim

  • @joecarini9958
    @joecarini9958 Рік тому

    Very informative..however, not sure if the music background was necessary, a bit distracting.

  • @johnhuggins5021
    @johnhuggins5021 3 роки тому +4

    I noticed you did not install a strap to the expansion tank to support it using the surrounding the wall. Has it been your experience that doing this step is not really necessary even if the tank fills with water, empties, fills, empties, etc. several times over its lifetime? Oh, and does it matter whether or not the schrader valve end is at the top of the tank or at the bottom? Or that depend on the manufacturer's recommendation for the install? Thanks for any feedback.

  • @914sam5
    @914sam5 2 роки тому

    Great job, I like to use four 45’s and a 90 after the T for the expansion tank 👍👍

  • @amarinayat8879
    @amarinayat8879 4 роки тому +3

    Excellent video, thank you!
    I have a couple of questions.... since I am planning installation in two locations in attic, one with very limited space....
    1. How far from the inlet side can an expansion tank be installed. Say, would it serve its purpose if I ran a 10 foot pipe from the inlet and installed the expansion tank sideways, or upside down? Shouldn't the air valve on the tank be easily accessible for maintaining pressure?
    2. How do you size an expansion tank for a 40 gal vs 75 gal water heater?
    3. How do you feel about using pex instead of copper?
    Thanks in advance for your help.

    • @Resq28
      @Resq28 Рік тому +2

      Great questions, I wish he would get back to some of these questions because I need the answers as well. Thank you for asking them.

  • @timrobinson9897
    @timrobinson9897 5 років тому +9

    Tim
    Job isn’t done quite yet. You need to check the water pressure from the city coming in. Easy to do just put a pressure gauge at a hose spigot preferably near where the water comes in. Take that pressure and use a small air hand air pump like a bicycle pump to pump up the expansion tank. On the expansion tank is an air valve it looks just like the one on your car tire. The tank needs to be inflated to the same pressure as the city. Otherwise the expansion tank is just a decoration and provides no benefit.

    • @PLUMBINGWITHTIM
      @PLUMBINGWITHTIM  5 років тому

      Very good point my friend. Thanks for sharing that. Much appreciated.

    • @darienlandry3244
      @darienlandry3244 4 роки тому

      Tim Robinson those typically come pre-charged

    • @kevinh9262
      @kevinh9262 Рік тому +1

      @@darienlandry3244 But you need to match the house water pressure. The tank may only be charged to 20 or 40 PSI from the factory. I just installed one at a house that had 60 PSI. Had to pressurize the tank. If you do not balance it, it will not work properly.

    • @davew657
      @davew657 10 місяців тому

      The info I'm looking for is a bit more involved. For instance, if you check your pressure with a gauge, are you getting a true reading if the water heater just heated up and is pushing it's thermal expansion back towards your gauge? He turned off the breaker but that did not cool off the water (in water heater) and thus, did not stop the back pressure of the thermal expansion. So, should you do this when water heater is cold, warm, or hot ? @@kevinh9262

  • @kokoyhawaii
    @kokoyhawaii Рік тому

    Copper is fine and fun to work with, but never had a problem with sharkbite

  • @eduarm1824
    @eduarm1824 3 роки тому

    my name is Edwin from Honduras and I love you body. nice job !!!!!

  • @stevie2132
    @stevie2132 4 роки тому +12

    Not legal in California..you need flex supply lines just in case of a earth quake.wish we can do it that way

    • @blueg3027
      @blueg3027 3 роки тому

      Has California ever heard of earthquake straps?

    • @drdez
      @drdez 3 роки тому

      @@blueg3027 I thought the straps keep the tank from tipping over not the pipes of it breaking because of the flexing of the pipes/house.

  • @herrickinman9303
    @herrickinman9303 4 роки тому +3

    Metal pipes soldered to the water heater would not pass inspection in California. California requires flexible water hoses and a flexible gas hose in order to minimize the chance of breakage during an earthquake. Sharkbite connections are allowed in California. You'll find Sharkbite hoses and connectors at Home Depot stores and Lowes stores throughout the state.

    • @dmdx86
      @dmdx86 Рік тому +2

      Sharkbites are allowed pretty much everywhere. Plumbers just don’t like them for various and often specious reasons.

    • @fish4food0071
      @fish4food0071 Рік тому +1

      They do not like shark bites because it shorten there time on job that can be charged. So the don’t make as much money!!

    • @WinnTeam
      @WinnTeam Рік тому

      @@fish4food0071 I don't like them because as an Engineer - i see them as less reliable than other options, my preferred is still copper pipes sweated together. Nothing to do with a plumber making more money - everything to do with failure points.

    • @kevinh9262
      @kevinh9262 Рік тому

      @@WinnTeam I'm an engineer and I have used them many times. They work great.

    • @tick_go5989
      @tick_go5989 Рік тому +2

      I recently experience corrosion rust build up where copper connection to the steel nipple on my water heater tank. With some quick research online turns out my viewers are correct about dissimilar metal reaction causing the rust. Sharkbite flexible possibly a better option to prevent corrosion!

  • @davedono5508
    @davedono5508 2 роки тому +2

    You didnt charge the new expansion tank to the existing house water pressure. THAT IS A MUST !!!!

  • @puppetpatti
    @puppetpatti 5 років тому +1

    Why am I not getting notifications? Look at you! 1700 subs! You are killing it! Woot!

  • @TheAwesome2626
    @TheAwesome2626 5 років тому +1

    Right on! Great video

  • @Travis-bu6yo
    @Travis-bu6yo Рік тому +1

    Did you not ream the pipe after you cut it?

  • @sonshenshomestead7668
    @sonshenshomestead7668 Рік тому +1

    Is it necessary to prep the water expansion tank with pressurized air first?

  • @thefloridaplumber2631
    @thefloridaplumber2631 5 років тому +1

    I have never put a wrench on the fitting on the expansion tank, just hand tight like you said, never had an issue. I will add my .02 cents and say I would have put a wrench on the female adapter to hold it while threading the tank on. As always Tim great video!

  • @adolfomares23
    @adolfomares23 8 місяців тому +1

    Whi didnt u use a union? With another nipple going to the water heater? I think it'll look cleaner...

  • @buck3093
    @buck3093 5 років тому +3

    Shouldn’t there be a couple Dielectric Unions on there? (Going directly from copper to galvanized)

    • @PLUMBINGWITHTIM
      @PLUMBINGWITHTIM  5 років тому +3

      Good question. Back in the day when water heaters had galvanized nipples
      These days they are made from a different alloy so it’s no longer required

    • @buck3093
      @buck3093 5 років тому

      PLUMBING WITH TIM That’s good to know! Thanks :-)

  • @Real_Rob_Reels
    @Real_Rob_Reels 9 місяців тому

    Did you debur the inside of the 6" pipe you cut so you don't get turbulence? Also, you never took the house water pressure and adjust your expansion tank to that pressure. Always a good rule of thumb to check pressures before the install. Most 2.5 gallon Exp. Tanks come at 50 psi but it's shooting in the dark until you get some hard data.

  • @kraftbuilt5245
    @kraftbuilt5245 4 роки тому +6

    Along with explaining how to charge the expansion tank, I think it’s worth mentioning the minimum distance of 18 inches away from the hot water heater that the expansion tank needs to be. You are very close to that.

    • @stanpiezuch9922
      @stanpiezuch9922 4 роки тому +1

      Can you elaborate on that "18 inches away" requirement and what is its purpose? Does it have to do with the heat from the flue pipe and the balloon part inside the expansion tank?

    • @mariosifuentes5994
      @mariosifuentes5994 2 роки тому +1

      Never heard of that , are you thinking the minimum height of the vacuum breaker perhaps?

    • @survivalSC
      @survivalSC 2 роки тому

      There is a code that says pex has to start 18inch from the water heater lines

  • @martinmoffitt4702
    @martinmoffitt4702 11 місяців тому

    nice neat and simple!

  • @JasonVladimir
    @JasonVladimir 5 років тому

    Good show, thanks for sharing!

  • @Sparkdawg1776
    @Sparkdawg1776 Рік тому

    Beautiful solder joints, wish you would have showed it

  • @garyteague4480
    @garyteague4480 4 роки тому +6

    I would only ask why you didn’t put a Union in the line so when that heater is replaced it would make it simpler

  • @kashaftasribatalmiahbialriyad
    @kashaftasribatalmiahbialriyad 9 місяців тому

    شرح رائع جدا ❤

  • @martywoodrow131
    @martywoodrow131 4 роки тому +2

    It would have been great to replace that gate vale with a ball vale

  • @MrRemerick
    @MrRemerick 2 роки тому

    Thank you, Brother.

  • @AJCoReTV
    @AJCoReTV 4 роки тому +2

    Sharkbite flex tubes work fine for me

    • @frankc.5430
      @frankc.5430 2 роки тому +1

      Required in some areas like those prone to earthquakes, not in others. Check your local code before you start and you're good.

  • @pallsmortion4750
    @pallsmortion4750 2 роки тому

    Great job, in the UK we need to fit a pressure regulator on the inlet, do you not need to? Thanks

  • @Honestandtruth007
    @Honestandtruth007 2 місяці тому +1

    I didn't See When to put Proper air pressure in Expansion Tank 😮😊

  • @donaldblank8873
    @donaldblank8873 10 місяців тому

    The pressure in the tank needs to be equal to the incoming pressure for it to be functional.

  • @markehooker
    @markehooker 3 роки тому +1

    I've watched a few videos and all the other plumbers checked the water pressure on the outside faucet and charged the expansion tank to the same pressure. This plumber did not?

    • @PLUMBINGWITHTIM
      @PLUMBINGWITHTIM  3 роки тому +1

      If you look through my videos I made a follow up video on just that. Thanks for watching

  • @themonkeydrunken
    @themonkeydrunken 11 місяців тому

    Did you check the house's water pressure, and add air to the expansion tank's bladder to match it? I didn't see that in the video. Remember to read the instructions everybody

  • @sedatedabe93
    @sedatedabe93 3 роки тому +1

    I also use type m pipe for all my installations.
    Usually I check water pressure of the home and pump my thermal tank to match the home psi. Before installing and some support
    Also some dielectric unions

    • @globeflicker9216
      @globeflicker9216 3 роки тому +1

      Whut!
      M copper is not suitable for potable use, L is. Check your codes.

  • @estuardoerazo9998
    @estuardoerazo9998 Рік тому

    Isn’t a vacuum breaker code in Florida?

  • @drummersanonymous
    @drummersanonymous 4 роки тому

    I thought you were about to judo chop the camera when you were cutting that copper pipe.
    Nice video. 👌🏼

  • @nadeemmian7750
    @nadeemmian7750 3 місяці тому

    wondering why you install expansion tank on the cold line. should it not be on the hot water line ?

  • @howardbardwell1265
    @howardbardwell1265 Рік тому

    Do you air up the bladder on the expansion tank? I thought it needs to be aired up to 60 to 75 psi.

  • @anthonyesparsen7776
    @anthonyesparsen7776 2 місяці тому

    Is this guy an actual licensed plumber guy?

  • @diezak2990
    @diezak2990 2 роки тому

    Should have used dielectric union to go from galvanized to coppers
    I'm an HV AC installer replacing water heater and furnace for realtor selling house
    I replaced water heater today in a tight spot old house with galvanized fittings and I didn't like came out because I had to install the expansion tank before the shut-off should I change it

  • @eallevato
    @eallevato Рік тому

    I am reading the installation instructions for a BACKSTOP expansion tank and they caution you to install the tank vertically with the air side in the downward position ONLY. Why is your installation backwards?

  • @carlthornton3076
    @carlthornton3076 4 роки тому

    Very Good!!!!

  • @fredost1504
    @fredost1504 9 місяців тому

    Sharkbites are the best. They just hurt your business is all. The homeowner can plumb, themselves.

  • @mitxchellmitxchell6564
    @mitxchellmitxchell6564 2 роки тому

    where are you located I'm in central Florida and needing of an awesome plumber like yourself.

  • @jackjones1727
    @jackjones1727 3 роки тому +1

    To replace the heater, you have to unsweat the joints. Is that normal?

  • @MonkeyManMechanicals
    @MonkeyManMechanicals 5 років тому +5

    no dielectric unions or unions at all???

    • @stevenmott4158
      @stevenmott4158 4 роки тому +1

      Christopher Segar why would he need a dielectric Union he is using all copper not mixing metals

    • @darienlandry3244
      @darienlandry3244 4 роки тому +3

      Steven R Mott he is mixing, you cannot adapt copper to galvanized without having brass in between it, flexes or dielectric unions, Electrolysis is real my friend, and Code

    • @stevenmott4158
      @stevenmott4158 4 роки тому

      The nipples that come with the water heater are not galvanized

    • @stevenmott4158
      @stevenmott4158 4 роки тому +1

      Heat trap nipples are already dielectric

    • @footlongburrito
      @footlongburrito 4 роки тому +1

      Its not about being dielectric anymore it's still code to use unions, now someone will have to cut the copper pipe to do anything... what if he couldn't start the heater because of a issue and had to return the heater and get a new one? Now without unions you can't without cutting pipe. This isn't code

  • @smidjee1225
    @smidjee1225 4 роки тому

    Thanks for the vid and info! What size expansion tank do you recommend for a 50gallon water heater? Or does it really matter?

    • @jinpark5324
      @jinpark5324 4 роки тому +3

      Smidjee it depends on 3 factors:1 size of water heater 2 your household water pressure 3 water heater temperature setting. Referring to the following doc page 2 figure 1 to find the right size of expansion tank you need.
      www.amtrol.com/wp-content/uploads/2019/02/9015-942-01_19-Thermal-Expansion-Tank-IO.pdf

  • @nathanoj894
    @nathanoj894 2 роки тому

    Isn't red copper type M a thinner gauge?? Or is that type L ?? I'm from California and we use blue copper type L cuz it's a thicker gauge and also cuz hot water is unforgiving. Just a thought thanks for vid.. type M is OK for pressure relief valve

  • @Monkeymanxxl
    @Monkeymanxxl 2 роки тому +1

    What state are you in? I don’t think this will pass inspection in California but I am not sure

    • @PLUMBINGWITHTIM
      @PLUMBINGWITHTIM  2 роки тому

      Florida

    • @Monkeymanxxl
      @Monkeymanxxl 2 роки тому +1

      Thank you for your quick response, nice work looks very clean. After my comment I watch the video to the end and heard you say Florida, California is a pain in the ass

  • @williammorris3303
    @williammorris3303 2 роки тому

    Can the expansion tank be to far away? I did a hot water tank , electric 40g tank , closed water system so I put in a 1.5g expansion tank, pumped it in the same way I always do. T&p valve blew as soon as the tank came up to temp. I thought how crazy that a new tank had a faulty valve, so I changed it. But it still blew the valve.

  • @jonathantrella832
    @jonathantrella832 5 місяців тому

    What the meth? They call anyone a plumber down in florida 🤣

  • @edwardkiker3629
    @edwardkiker3629 4 роки тому +2

    Didn't adjust air pressure to meet water pressure! Wasted you time and customers money. Come on man. You a plumber? Do it correctly or don't do it.

    • @PLUMBINGWITHTIM
      @PLUMBINGWITHTIM  4 роки тому +1

      Thanks for watching
      Actually I did just forgot to add to video
      I did a follow up video on just that if you go back on my videos you’ll see

  • @winstontaylor4364
    @winstontaylor4364 Рік тому

    I think you missed a few steps on the way, you never checked water pressure to set air pressure for the expansion tank neither did you put an isolation valve on the hot water side to prevent building drain down if repairs need to be made neither did you install a union on either line to facilitate tank replacement

  • @Silvertheta
    @Silvertheta Рік тому

    Do you need to add air into the expansion tank or is it preloaded with air already? TY

  • @anthonyesparsen7776
    @anthonyesparsen7776 2 місяці тому

    I used spa wrench to tighten my expansion tank once it twisted all my copper pipe system

  • @onemorething100
    @onemorething100 4 роки тому +1

    Hi Tim. Hopefully you can help me. I've had issues with high pressure in my home. At first I tried to adjust the Pressure regulator but soon realized it was not working. So I replaced it. I set the pressure at 60 and put a gauge on overnight but I'm still getting high readings. It seems to coincide with the HWT firing up. I don't have an expansion tank installed.
    Can thermal Expansion cause high pressure through out plumbing? My Neighbor said the expansion would only occur in the HWT not the home plumbing and an Expansion tank would not lower the pressure. I have a hard time believing the regulator is bad. any thoughts?
    Thank You

    • @matthewmusselman373
      @matthewmusselman373 4 роки тому

      The rise in pressure starts at the water heater from thermal expansion. But without a place for the pressure to go it passes through the water heater and pressurizes the cold water line as well. They are one common water system unless they are separated by check valves. The expansion tank could help. The pressure surge could be caused by something else also. Quick acting valves like the ones used in irrigation or at your washer machine can cause a water hammer that may give you a high pressure reading.

    • @onemorething100
      @onemorething100 4 роки тому

      @@matthewmusselman373 Thanks Man. A few weeks ago Installed A pressure tank and that seemed to correct the problem.

    • @jeffreyplumber1975
      @jeffreyplumber1975 3 роки тому

      THERMAL EXPANSION install tank and call me in the morning!

  • @mrlukenukem88
    @mrlukenukem88 2 роки тому

    Copper fip should be brass coming off the top of the tank.

  • @davidmaddox6829
    @davidmaddox6829 4 роки тому +2

    Don't you need to confirm the pressure of the new tank before installing it?

    • @PLUMBINGWITHTIM
      @PLUMBINGWITHTIM  4 роки тому

      Yes indeed and I made a video shortly after this one explaining that. Thanks for watching!

  • @anthonyesparsen7776
    @anthonyesparsen7776 2 місяці тому

    I have never seen anyone put two types of sealing tape and that other moist liquid type on a fitting

  • @jayham1970
    @jayham1970 2 роки тому

    If water departments had not for [stupid reasons] started putting check valves into systems (absolutely was not needed), expansion tanks would not be needed. The reasons given for closing off systems was absolutely asinine.

  • @RichRich007
    @RichRich007 2 роки тому

    how can you put a wrench on there to "snug it all the way up" when its soldered in place?

  • @BillAnon
    @BillAnon 11 місяців тому

    How do you tell what size expansion tank you need?

  • @tty3146
    @tty3146 2 роки тому

    I have 2 heaters and expansion tank for each. one has pressure 55 psi and other has 75 psi. system pressure is 60 psi. Recently I am getting warm water from cold faucet. I changed tub cartridge but still getting warm water. What can be the issue? Faulty heat trap?

  • @SSMLivingPictures
    @SSMLivingPictures Рік тому

    It seems theres an unfortunate trend in literally no one covering the pressure matching aspect. Are there no competent plumbers on YT?

  • @Scorpiomaj27889
    @Scorpiomaj27889 4 роки тому +1

    Hello, any specific reason you don't want sharkbites? Are they not technically up to code?

    • @darienlandry3244
      @darienlandry3244 4 роки тому

      There a hack job

    • @dmdx86
      @dmdx86 Рік тому +1

      Sharkbites allow DIYers and handymen to do plumbing jobs that normally you’d used to call a licensed plumber for. Sharkbites work and last if you follow instructions. Problem is unskilled people often don’t follow instructions (don’t deburr their copper and/or don’t insert the fitting to full depth) and you end up with leaks and they get a bad rep as a result.

  • @neogeo8267
    @neogeo8267 2 роки тому

    No dielectric unions?

  • @forextrinitrader
    @forextrinitrader 3 роки тому +1

    Do expansion tanks really need to be 18 inches away from the cold water valve? Is the measured in straight line along the copper and includes that 6 inches up from the T adapter?

  • @MyGodzilla33
    @MyGodzilla33 Рік тому

    How come you didn't mention put the water pressor air in to expantion tank before put them on?

  • @kevinscanlon1823
    @kevinscanlon1823 3 роки тому +2

    Where are the dielectric unions?

  • @LogginzLyfe
    @LogginzLyfe 2 роки тому

    I replaced my expansion tank today and now I have very little pressure and hot water. Any ideas what’s wrong? I didn’t think the tank had anything to do with that. It was working fine before the replacement.

  • @jeffcoleman5160
    @jeffcoleman5160 Рік тому

    Should replace those valves anyway

  • @IgnatiusRobertson
    @IgnatiusRobertson 3 роки тому

    this is good.

  • @rajeshgajjar3774
    @rajeshgajjar3774 Рік тому

    Expansion Tank which Pipe Hot water or cold water ?
    The pressure will be creat steam in hot water so expansion tank must go hot water pipe.
    Please could you check again ?

  • @kawaiibtslover1012
    @kawaiibtslover1012 4 роки тому

    No hammer arresters required in Florida?

  • @jayham1970
    @jayham1970 2 роки тому

    I was thinking that you had to check the water pressure in the house, and then you had to add air pressure to the expansion tank to match that of the water pressure. Has the design changed in expansion tanks so that that process is no longer needed?

  • @polarlab113
    @polarlab113 3 роки тому

    Why you guys never read instructions?it says right in there to mount vertically with the schrader valve on the bottom.upside down leaves no head pressure and the tank will fail prematurely.as well you didn’t check the house pressure in order to properly adjust the expansion tank BEFORE it is installed.check the website it shows and explains very simply

  • @BOSS_805
    @BOSS_805 7 місяців тому

    Why are you not using di electric unions?

  • @anthonypapa8676
    @anthonypapa8676 Рік тому

    Can you mount that tank on its side or does it have to be up and down

    • @Grizzleback07
      @Grizzleback07 5 місяців тому

      I mounted mine on its side because of room constraints and used strapping to help support it. No problems yet in the past 8 yrs.

  • @nolantanaka565
    @nolantanaka565 5 років тому +1

    Do you need a check valve too?

  • @desrickgurule2871
    @desrickgurule2871 5 років тому

    Nice work GOSH Darn Tim!!! Well done