HERE'S WHY CP3 REGULATORS FAIL

Поділитися
Вставка
  • Опубліковано 5 жов 2024
  • Nick Priegnitz of Duramaxtuner was curious how the fuel pressure regulator works so we cut one open and are showing you what we found on this Diesel Insights!
    Subscribe to learn more about how diesels work!

КОМЕНТАРІ • 82

  • @darebear2438
    @darebear2438 8 місяців тому +2

    I’m waiting on my new FPR to come in the mail, so I’m trying to do as much research about it before it gets here. Thank you for this video. Side note, I laughed when you said “maybe you let it sit for two years and the fuel went bad inside the regulator”. That’s exactly what I’m trying to remedy at the moment 😂

    • @Duramaxtuner
      @Duramaxtuner  8 місяців тому +1

      @darebear2438 Haha love that, that resonated with you! We know it's all too common on these aging diesels.

  • @dynamicexcavating6611
    @dynamicexcavating6611 Рік тому +1

    I have recently found this channel. I am enjoying the information and that it is presented well. Please keep the knowledge shared, it is appreciated.

  • @davesea4630
    @davesea4630 11 місяців тому +1

    I can’t tell you how much this is helped me you’re great descriptions are very much appreciated. Look forward to seeing more of your videos. No one else even mentioned checking the low pressure side. I’ll do that and then probably end up replacing my FPR.

  • @zacharymetz8815
    @zacharymetz8815 3 роки тому +3

    0:40 “…or not fix it bc it’s a sealed unit…”
    made me chuckle 😅

  • @tonyhall5669
    @tonyhall5669 2 роки тому +4

    Awesome info guys, you guys are better than my TAC center At GM
    I think this is an overlooked small issue that techs tend to miss

  • @nono-fn3zc
    @nono-fn3zc 3 роки тому +1

    I just fixed my buddy’s lbz; same problem. Truck sat a lot and fpr got shitty down low. His issue went one further though - chafed wire loom allowed two wires to ground and blew a fuse. He got vane position and fpr codes, with rp at max during idle. Fixing the wires and replacing the fuse were the final fix. Crazy.

  • @blainegregg3951
    @blainegregg3951 Рік тому +1

    Great info as always. I have a high rail pressure issue after letting the truck sit for a while. I now have a good understanding of what to check.

  • @2ndAmendmentGlock
    @2ndAmendmentGlock 5 місяців тому +1

    I have an LMM and I have the complete opposite happening, when applying throttle my fuel rail pressure will drop from desired and usually level out around 2000 psi. Usually this causes a p0087 but sometimes if you give it more throttle it will go jump back up to desired rail pressure. I'm suspecting the regulator wanting to slide into a low flow position or like you mentioned in the video it's just not sliding smoothly and occasionally gets stuck.

  • @allen4779
    @allen4779 3 роки тому +6

    These guys are fantastic I love there products and there are great honest guys that have a passion that they turned into a business I will always run there stuff no matter what brand I drive thank you Calibrated power you guys are awesome

  • @korn111685
    @korn111685 2 роки тому +4

    Absolutely excellent video. Exactly the information I needed to understand the problem I'm having. Thank you.

  • @3Mudbone1
    @3Mudbone1 2 роки тому +1

    If you have a scanner such as a Snap On Verus edge one indication of a bad F.R.P. Reg. is at idle having aprox. 63% f.r.p. demand instead of about 26%. Also the engine will stumble a split second when you start it, and your desired f.r.p. is about 5,800, and actual f.r.p. is about 9,500 at idle. And there is a chance that you will be limited to 2,000 R.P.M. I believe that if you put a new Fuel Rail Pressure Regulator on after 100,000 miles it is a good thing. It will increase your power, and mileage, plus burn cleaner. I have seen an Engine Control Module which was randomly not providing power thru the purple wire with a white stripe (F.R.P. Regulator Supply Voltage). I used my new Snap On 'Pass Thru Assistant' Scanner to check for updates to my E.C.M., amazingly enough there were no updates needed and the E.C.M.'s calibration was good. Two engine starts later my E.C.M. went back to working flawlessly. I believe that the LLY Engine Control Module is a high quality unit which is actually unusual in this day and age. I highly recommend NOT having a bunch of aftermarket stuff such as a remote start. At the very least inspect all the wiring very closely after the stereo shop does the install, car toys is not a place that has a lot of competent technicians. In fact maybe 5% of the stereo shops can be trusted. The manufacturers use the cheapest solder they can find, which costs us all money because of electronic failures. Lead free, and low lead solder causes problems as well. A thing called 'silver migration' can occur on your Printed Circuit (P.C.) boards. Some electronic/ radio repair shops can address silver migration issues.

  • @erikwelker3483
    @erikwelker3483 3 роки тому

    Another great video. I can't wait to Tune my truck in March after my warranty runs out!!!

  • @paulbibb578
    @paulbibb578 3 роки тому +2

    Always good info on this channel. keep the good content coming.

  • @blackdog1960les
    @blackdog1960les 3 роки тому +1

    Thanks Nick --- you made that easy to understand and simple

  • @Steele44320
    @Steele44320 Рік тому

    Great info!! That explains why I got a P0088 Fault. So isolate the CP3 with a regulator to the pressure equal to tack pump pressure?

  • @Re-engineer_everything
    @Re-engineer_everything Рік тому +1

    I just got a P0087 which is low fuel rail pressure. The truck idles well enough to move my Montana 5th wheel but as soon as I press on the throttle it is not happy. It’s almost that the FPR decided to stop working. When I try to drive it the Fuel Rail Pressure goes all the way down to 1.9k. I will swap out the FPR today. This all happened within 2 days. I will update this if it fixes the problem.

    • @BlahDeDah7
      @BlahDeDah7 Рік тому

      So I’m guessing it didn’t fix it?

  • @wilcox1105
    @wilcox1105 Рік тому

    i appreciate this video so much!!! thought it was my injectors again!!

  • @matthewbuyak4827
    @matthewbuyak4827 3 роки тому

    Nice! My duramax was doing that. Nice to know why. Thanks!

  • @zackk695
    @zackk695 3 місяці тому

    Mine sounds like it’s a blown engine only when cold. As it heats up it runs perfect. Can a FPR not work correctly when cold or do I have another issue? Answers appreciated greatly

  • @captnformula
    @captnformula 2 роки тому

    Thank you. Clear and simple.

  • @FlatPlaneCranky
    @FlatPlaneCranky 3 роки тому +1

    Thank you Nick!

  • @marioguillen6910
    @marioguillen6910 2 роки тому +1

    Just have that rough idle up and down on my 2004 duramax
    I'm changing that tomorrow

  • @jaredmowen2007
    @jaredmowen2007 3 роки тому

    Awesome video. Thanks for the insight! What is the regulator actually controlling? Those o-rings don't look like they're built to handle high pressure. From some animations I've seen it looks like it controls low side pressure to the valves at the top of the 3 pistons. I guess that effectively varies the output of the high side pump?

    • @Duramaxtuner
      @Duramaxtuner  3 роки тому

      Thanks Jared. You got it, spot on. The regulator control is still low side. From the regulator the fuel goes in for the high side squeeze.

  • @eimantas28
    @eimantas28 8 місяців тому +1

    Do you maybe sell CP3 r110 old/bad pumps? I would like to buy them and get shipped to europe

    • @Duramaxtuner
      @Duramaxtuner  7 місяців тому

      @eimantas28 Just came across your comment! We do have a few CP3 cores laying around. Shoot us an email at Ben@Durmaxtuner.com and let us know how much you are willing to pay for them. Would love to work something out. Also if you don't mind me asking, are these being used on BMW's some how?

    • @eimantas28
      @eimantas28 7 місяців тому

      @@Duramaxtuner Yes on BMW, i want to find out how to fit them.

    • @Duramaxtuner
      @Duramaxtuner  7 місяців тому

      @@eimantas28 Awesome! Shoot me an email and I will see what we can do.

  • @steveguest8028
    @steveguest8028 Рік тому +1

    Great video this very well explained

  • @chancesanborn7932
    @chancesanborn7932 3 роки тому +1

    Touching on the 2 stroke oil and atf thing, would it help to add some of that stuff in conjunction with a lift pump on an LML to help prolong the life of the cp4? If so, how much would you recommend adding to each tank?

    • @nickpriegnitz5895
      @nickpriegnitz5895 3 роки тому

      Do not use it on an emissions equipped truck. Oil contamination can ruin the DPF.

    • @chancesanborn7932
      @chancesanborn7932 3 роки тому

      @@nickpriegnitz5895 that’s a good point, guess that slipped my mind. What’s your best recommendation for adding lubricity for that pump we all know is prone to failure?

    • @BigGroupHug
      @BigGroupHug 2 роки тому

      @@chancesanborn7932 FPPF and other companies make DPF & SCR friendly additives

  • @BigGroupHug
    @BigGroupHug 2 роки тому +1

    Thank you Nick

  • @ottolau6843
    @ottolau6843 2 роки тому +1

    great presentation

  • @OldskoolArtCustoms
    @OldskoolArtCustoms Рік тому

    My LMM seems to have opposite condition. I was hauling a small car and went Into reduced power. Pulled over and it was loping with light grey smoke. Shutdown 2 min. Problem went away. All normal. A few days later, no WOT power. Did replace bad high rail pressure switch (forgot code). No power on hills n takes forever to get upto 65mph regardless if hauling. Think my regulator is stuck in LEAN?

  • @freddexta3363
    @freddexta3363 2 роки тому

    Is there a difference between years on the Cummins 5.9 regulators? I'm about to change mine and would preferably put the correct one in :)

  • @brianshaffer5090
    @brianshaffer5090 2 роки тому

    I've got a brand new Bosch fuel pressure regulator and it is just buzzing when you turn the key on. I have a crank and no start situation. I'm sure that I got a new defective regulator. I just kind of wanted to see what your thoughts might be on this.

    • @Duramaxtuner
      @Duramaxtuner  2 роки тому

      Have you ever had electrical/ECM issues with the truck?

  • @timothymroberts2949
    @timothymroberts2949 Рік тому +1

    Very informative

  • @jaechoi137
    @jaechoi137 5 місяців тому

    My truck CP3 pump not getting fuel and I did open up fuel filter and found it is half empty. My truck doesn't have any other lift/supply pump anywhere including fuel tank.
    Do you think it also can be the bad Fuel Pressure REgulator? Thanks in advance for your input!

    • @Duramaxtuner
      @Duramaxtuner  5 місяців тому

      It's hard to say, but the regulator could be the issue.

  • @clayton7596
    @clayton7596 Рік тому

    Nick ,its possible this regulator stack and the truck doesn't shutoff the engine with the keys turn in off ? my truck now doesn't want to shutoff ,I need shut at battery .Thanks brother,

  • @SALMONSLAYER06
    @SALMONSLAYER06 Рік тому

    thanks. so how is everyone dialing back or adjusting the low pressure feed going to the cp3?

    • @Duramaxtuner
      @Duramaxtuner  Рік тому

      Give us a buzz 815-568-7920, the forums are also a great spot for knowledge too.

  • @tsd21132
    @tsd21132 3 роки тому

    They were the same on lb7 and lly right?

  • @davesea4630
    @davesea4630 11 місяців тому

    I guess if I had a question, it would be how do I measure my psi on my low pressure side what is it that once again thank you

    • @Duramaxtuner
      @Duramaxtuner  11 місяців тому

      Give us a call, we can help. 815-568-7920.

  • @KenyonPayne
    @KenyonPayne 2 роки тому

    Does a cp4 metering valve do the same thing? I have a volkswagen 3.0L tdi, and I occasionally get a surging at idle for about 20 seconds, and I get a p0087 code

  • @perryhanson7878
    @perryhanson7878 2 роки тому

    Thanks for the info

  • @zackk695
    @zackk695 3 місяці тому

    My 05’ Duramax sounds as off the motor is blown when it starts cold at 60 degrees or so. Popping and knocking bad. As the engine runs it runs better. After 20 mins and engine temp at 180 or more it runs smooth. We have no great mechanics in Houston and my diesel mechanic is lost

    • @Duramaxtuner
      @Duramaxtuner  3 місяці тому +1

      Datalog and send to your tuner, if the truck is tuned. Codes and datalog will help diag.

    • @zackk695
      @zackk695 3 місяці тому

      @@Duramaxtuner I’m actually with some great people that tuned my truck out of Michigan. Calibrated Power and they asked me for the data so I’m doing that today. The issue now is it’s running perfect the last 2 days. I’m glad but it’s frustrating because it’s not showing me the issue on the scanner and can’t figure it out. The last shipped looked for hours and found nothing and he was so mad because side he couldn’t figure it out and they also can’t charge just for looking if they don’t actually diagnose the problem.

  • @imtheplayerandthecoach2409
    @imtheplayerandthecoach2409 3 роки тому

    I have 2nd gen cummins 24v vp powered doing similar replaced cleaned grounds do they have fuel regulator valve ?

    • @Duramaxtuner
      @Duramaxtuner  3 роки тому +1

      The VP trucks don’t use this type of regulator. It’s strictly a common rail part.

  • @koltonzapp2766
    @koltonzapp2766 3 місяці тому

    How could a fuel pressure sensor be bad on a brand new lbz cp3 pump put in a lb7 duramax

  • @TIIRONC5H
    @TIIRONC5H Рік тому

    Can this cause no acelerator pedal response ??

  • @darrinhuffman
    @darrinhuffman Рік тому

    It was very helpful

  • @larylongprong
    @larylongprong 5 місяців тому

    How about a P0089 code?

    • @Duramaxtuner
      @Duramaxtuner  5 місяців тому

      Fuel Pressure solenoid is faulty.

  • @richardtillichE36
    @richardtillichE36 2 роки тому

    great video!

  • @Noupi13
    @Noupi13 Рік тому

    Great info, thank

  • @auggiesbandmeonthefly6500
    @auggiesbandmeonthefly6500 Рік тому +1

    So good!!!!

  • @duramaxguy74
    @duramaxguy74 3 роки тому

    Is a couple hundred psi fluctuation normal at idle?

    • @nickpriegnitz5895
      @nickpriegnitz5895 3 роки тому +1

      If you can't detect it "Seat of the pants" and there are no codes, it's okay.

    • @duramaxguy74
      @duramaxguy74 3 роки тому

      @@nickpriegnitz5895 thanks man👍

  • @neilwalker8686
    @neilwalker8686 3 роки тому

    Cp3 does not die, it is just waiting for a rebuild. The cp4 however……

  • @czealtamahawk1228
    @czealtamahawk1228 2 роки тому

    Most diesel truck owners in TX sounds like they all have ones and they're all proud to showcase their rigs. Semis???? Drivers could care less and let it run all night while they're snoring inside the cabin.

  • @AaronCook83
    @AaronCook83 Рік тому

    Demonstrations don't work so great with the entire truck in frame for tiny parts.

  • @james10739
    @james10739 2 роки тому

    No way that solenoid works at 5v but only 1.5 milliamps maybe 150 milliamps

  • @seanmcken4697
    @seanmcken4697 2 місяці тому

    Great great great video thank you