Generac: Smart Management Module Installation, 100 AMP

Поділитися
Вставка
  • Опубліковано 1 жов 2024
  • In this video a #generac #generator Smart Management Module load-shedding device is installed. This allows for smaller air-cooled generators to supply loads "only if" the generator is able to start larger electrical loads such as heated Hot Tub. Always contact a Generac Certified contractor for sizing, maintaining, and servicing your Generac standby generator.
    Electrical Wiring is NOT a hobby. Call a licensed electrician!
    www.generac.com
    Classic Electric, LLC is a Generac standby air-cooled generator installer.
    Generac Dealer # 1019500
    Classic Electric, LLC | Point Pleasant, New Jersey
    License & Business # 16557
    (732)-770-1437
    Ron Pecina Jr. is a licensed electrician in the state of New Jersey. This allows him to apply for electrical permits, work with live conductors, remove meters, and disconnect service from the utility company. New Jersey observes the 2020 NEC and the Uniform Construction Code. The majority of the work seen here on this channel falls under the Rehabilitation Sub Code (Chapter 6 of the U.C.C.). The majority of the work you’ll see on my channel falls under the New Jersey Rehabilitation Subcode. www.nj.gov/dca...
    ALL New Jersey licensed electricians MUST complete 34-hours of continuing education units each tricentennial period. This includes a mandatory 10-hour code update course. Any work above 10-volts requires an electrical license in New Jersey.
    Ron is an active member of the New Jersey Independent Electrical Contractors Association.
    Want to be an electrician? Start here: www.myelectric...
    Become an NJ-IEC member here: www.nj-iec.org
    IEC National: www.ieci.org
    Customer Guide for Electrical Installation; JCPL: www.firstenerg...
    Customer Guide for Electrical Installation; PSEG: nj.pseg.com/bu...
    WANT TO SEE MORE? FULL 200 AMP SERVICE UPGRADE. WATCH HERE: • FULL 200 AMP SERVICE U...
    Ron Pecina Jr’s set up:
    Camera: Go Pro 9/ 10 w/ the Media Mod
    Microphone: DJI Wireless
    Editing software: Apple iMovie
    Animation software: Apple Keynote
    Background Music & Sound Effects by Soundstripe.com
    Like, Share, and Subscribe!
  • Навчання та стиль

КОМЕНТАРІ • 36

  • @Californians_go_home
    @Californians_go_home 9 місяців тому +5

    Anytime I see the word SMART in a system of technology, I assume the government or tech has the ability to lock you out of it.

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  9 місяців тому +5

      Unless you have your own power plant, the govt has been able to do that since the advent of electricity.

    • @Californians_go_home
      @Californians_go_home 9 місяців тому

      Wait until they only give us an ‘allowance’ per month. The county next to me has already banned natural gas installation for new builds, and no wood heat. Seems pretty easy to flip a switch on us now so we can comply. If we want food. It’s also why I keep an older car that doesn’t connect to WiFi . Love the channel Ron!

  • @gosolxsolar
    @gosolxsolar 8 місяців тому +1

    Hmm. Nice video. Just trying to understand. You said the red marked conductors were for loads and black for line. But you have the red ones going to the circuit breaker which i would call line terminals since power comes from those. I would call the hot tub conductors load, but you have those marked black. What am i missing? Also, is it really just 1 circuit per smm?

  • @BigD63
    @BigD63 9 місяців тому +1

    Ron, once again great video. Merry Christmas to you and yours. Happy new year. Best regards from Chicago

  • @JMDangler
    @JMDangler 9 місяців тому +1

    Haha @10:37 been there before. The I wish I had more hands moment. SOAB is the technical term for it. Great video, keep trucking Ron 🎉

  • @wirenut9062
    @wirenut9062 4 місяці тому

    Offset and bonded locknut...no ?

  • @scottdenham848
    @scottdenham848 9 місяців тому

    Great videos Ron, working with frequency makes sense because the hertz goes down with increasing load (reducing speed below 3600 RPM.) An innovative way to do it. Merry Christmas.

  • @Nahum17good
    @Nahum17good 9 місяців тому +1

    I always enjoy watching your videos. They’re very inspiring. Have a Merry Christmas Ron.

  • @chuckquinn8026
    @chuckquinn8026 9 місяців тому

    Sweet! Merry Christmas to you and your family Ron! Fur babies too ❤️. 🎅🎅🎅

  • @donmclean1220
    @donmclean1220 7 місяців тому

    Plumbers would call the nut on the flex a “compression nut” I think.

  • @mackfisher4487
    @mackfisher4487 9 місяців тому

    Ron Merry Christmas
    Thank you for all the great videos, and continuing regardless of some of us not being kind in our comments.
    Ego jumps out in many of them, I suspect that people forget the golden rule.

  • @jw228w
    @jw228w 6 місяців тому

    thanks for the video.in a residential home does each large load require its own relayer can one relay handle more than one load with different priority settings?thanks John

  • @Bob.W.
    @Bob.W. 9 місяців тому

    Dig the pull chain headgear. Thx. Have a Merry Christmas.

  • @Framdark
    @Framdark 9 місяців тому

    I really appreciate the work you put into your videos have a great Christmas Ron!

  • @MC-ig8cm
    @MC-ig8cm 9 місяців тому

    Merry Christmas I enjoy your videos! Thank you

  • @katyair1
    @katyair1 9 місяців тому

    I hope you had a good Christmas and happy New Year🎊

  • @mattschoular8844
    @mattschoular8844 9 місяців тому

    Another nice job. Merry Christmas Ron

  • @kesleicarvalho4062
    @kesleicarvalho4062 9 місяців тому

    Nice job, Ron.
    Congratulation

  • @davidbush2414
    @davidbush2414 8 місяців тому

    I like the video. You’ve got some great content.
    New subscriber 👍🏻

  • @PaulDziomba
    @PaulDziomba 9 місяців тому

    Merry Christmas and a Happy New Year to you and all your subscribers as well!

  • @dogboy19d31
    @dogboy19d31 8 місяців тому

    So no control wiring needed to the transfer switch?

  • @scotts4125
    @scotts4125 9 місяців тому

    Generac had defective 60amp load sheds. If the PCB is green it's one of the problematic ones. The load shed stays open as a row of caps or resistors (I forgot which) burns out. The revised replacement boards are blue. In my case one of my A/C's stopped working. I had power from the breaker but no power at the A/H. It had me stumped until I remembered the load sheds. On utility power your device will not work if the board is fried. I bypassed the contactor and everything worked again. I later found out you can just disconnect the wire going to the board and the contactor will close. It works the opposite of an A/C contactor. It's normally closed pulled in is open. The replacement blue board fixed it.

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  9 місяців тому

      why would you need load sheds on the air handler? Its the condensing units that consume power during start up, not a blower motor on the furnace/ air handler.

    • @scotts4125
      @scotts4125 9 місяців тому

      @@electricianron_New_Jersey That's a great question and I thought the same thing. The generator company did the install. I never checked power to the condenser. My Tstat was out. That's how I noticed there wasn't power. I assumed it was the float switch. It wasn't that. I'm a DIYer so it took me a couple hours to figure out it was the load shed. I couldn't understand how I had power at the breaker and nothing at the A/H. At one point I wondered if a critter ate both lines in the attic but didn't short the wires out. lol I was grasping! They probably hooked it up wrong. I also have a second unit but that load shed is a PSP which from everything I have read is a much better unit.

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  9 місяців тому

      what size generator?
      @@scotts4125

    • @scotts4125
      @scotts4125 9 місяців тому

      @@electricianron_New_Jersey 22kw House is 3200 sq ft.

    • @price9195
      @price9195 9 місяців тому

      Kohler uses time delay contactor on the "y" thermostat wired in series back to the compressor. Keeps the compressor off until the time delay contactor comes on in the transfer switch. Nice way and the wire is low voltage side of the equipment. Thanks for all the great videos Ron!

  • @sixfour7
    @sixfour7 9 місяців тому

    Did you consider AC Soft Starter?

  • @cwk_619
    @cwk_619 9 місяців тому +1

    Merry Christmas and a Happy to New Year to you and yours also...((Its nice to see people still saying that....and not just Happy Holidays!!!))