How to Install a Ridge Vent | Shingle Roof Install Guide

Поділитися
Вставка
  • Опубліковано 6 жов 2024

КОМЕНТАРІ • 79

  • @RoofRepairSpecialist
    @RoofRepairSpecialist  2 роки тому +3

    Now that we've made tutorials on ridge vents, inflow vents, dormers and O'hagins, let me know which one you install the most and why!

  • @xXcampx
    @xXcampx 4 місяці тому +7

    I'm a building contractor with over 30 years experience and have shingled hundreds of houses. I ran into something I've never encountered before: a roof that was reshingled about 15 years ago was leaking at about 5 spots at the ridge and it had this type of ridge vent. The roofer neglected to install the Mastic underneath. So what was happening was, rain and dew ran off the caps, made contact with the bottom edge of the ridge vent, and worked its way back under the ridge vent (similar to how a curved gutter helmet pulls rainwater into a gutter.) Once the water made contact with that mesh air filter, it acted as a sponge and through capillary action it pulled the water into the house. When I tore the ridge vent off, that mesh filter was sopping wet. Takeaway lesson: when using this brand of ridge vent, don't skip the step of installing Mastic! $20 worth of Mastic would have prevented a $2500 call-back. As an aside: I always hand nail caps. Too many roofers use the gun, it crushes the cap shingles and restricts air flow.

  • @samanthabenton552
    @samanthabenton552 2 місяці тому

    Such and amazing video!! Very detailed, it helped me and my friend understand our DIY roofing project more in depth! We love strong informative men!!

  • @KidFreshie
    @KidFreshie 10 місяців тому

    Love your videos! One correction at 1:02 though. Owens Corning ridge vent is only for pitches up to 20 : 12. You could probably make it work for steeper but the packaging specifies 20 : 12 is the limit.

  • @charlespasquarella1620
    @charlespasquarella1620 9 місяців тому +1

    I’ve seen that type of ridge vent pop up so many times/ roll vent is the way to go

    • @RoofRepairSpecialist
      @RoofRepairSpecialist  9 місяців тому

      Different than the one we’re using? The issue might have been the length of the nail.

    • @charlespasquarella1620
      @charlespasquarella1620 9 місяців тому

      Next time you get supplies look for it been using it for years/ roll vent

  • @rshutterbug47
    @rshutterbug47 Рік тому

    Thanks & That WAs The BEST Ridge Vents I've Seen & Not One Other Video Showed or Even Talked About Using Mastic AT ALL OR THE End Cap, So You & Owen's Corning Win win ,Cause We Need To Do SOMETHING & This is What I Think Is The Best Way To Go, & ALSO Can It Be Stepped On At All Without Distraction of It , & The Cap Shingles ??? Thank You

    • @RoofRepairSpecialist
      @RoofRepairSpecialist  Рік тому

      Thank you, glad you found it helpful. Generally ridge shouldn’t be stepped on too much. But if you do it’ll be fine, I think the ridge is the problem when stored on not the ridge vent

  • @sethfitzgerald425
    @sethfitzgerald425 Рік тому

    Thanks so much! I appreciate you and the channel.

  • @javierjames9991
    @javierjames9991 Місяць тому

    Chingon compa, Gracias 🎉

  • @DB-hf7di
    @DB-hf7di 2 місяці тому

    Does the same ridge cap shingle go on top of the ridge vent and the other spots on the ridge which may not be vented? I heard it's important to use ridge caps instead of cut 3 tab shingles on the ridge vents as well. Why would this be if the ridge vents are plastic and durable?

  • @mattlord2906
    @mattlord2906 Рік тому +1

    Do you have a method for installing over existing double layer roof? The current ridge vent is for looks only

  • @Wooster77
    @Wooster77 Рік тому +1

    Does the poly mesh get dirty after a while and block the flow of air?

    • @RoofRepairSpecialist
      @RoofRepairSpecialist  Рік тому +1

      I can’t comment on that, I haven’t seen it happen, however it is possibly a valid concern

  • @InsidetheCasino
    @InsidetheCasino Рік тому +2

    I have that Owens Corning ridge vent on my house, and it SUCKS! Hardly any hot air moves through it. Now my new shingles are losing TONS of granules just 3 years out thanks to the convection oven I have in my attic that’s baking the shingles from the inside. Wish I had my roofers do turtle vents instead.

    • @RoofRepairSpecialist
      @RoofRepairSpecialist  Рік тому +5

      Do you have appropriate intake vents? at your eaves soffits. If not the ridge vents are completely useless. Venting is a system, if you only have one component of it it is pointless.

  • @CharlieMoDank14
    @CharlieMoDank14 10 місяців тому

    Thank you.

  • @olcotttheosophy
    @olcotttheosophy 2 роки тому

    Andrew ! Well said.

  • @mattlord2906
    @mattlord2906 Рік тому +1

    Just discovered on a friend mom's roof that the ridge was installed over a second layer of roof. But both roofs are sealed so no air is leaving this roof. Sided over the original side dormer vents. One vent on roof. Disaster

  • @johncooper7751
    @johncooper7751 11 місяців тому

    So I just had my house reroofed and I noticed they didn’t put the ridge vent back up over my dormers they should’ve probably been replaced right?

    • @RoofRepairSpecialist
      @RoofRepairSpecialist  11 місяців тому

      Not necessarily, venting is a complicated topic as far as placement and quantity. You have to make sure you have a balanced system inflow versus outflow.

  • @EstateFlip
    @EstateFlip Рік тому

    Could you install a ridge vent along with Owens Corning Low Profile Roof Vents?.. or is it one or the other?

  • @locacoyote
    @locacoyote 11 місяців тому

    I'm very curious about something having to do with ridge vent over box. My experience is that venting should be 50/50 or 40/60 intake and exhaust in sq inch/foot. Yet I see many roofing jobs running ridge vent the full length of the ridge which would greatly exceed the intake area. Can you clear that up for me?
    Thanks.

    • @RoofRepairSpecialist
      @RoofRepairSpecialist  11 місяців тому

      You are 100%correct and more knowledgeable than 80% of roofers. Venting needs to be well thought out and balanced to be effective.

    • @locacoyote
      @locacoyote 11 місяців тому

      Thanks for making that clear. I'm using GAF and there are easy instructions right on the box so I had to wonder why run the whole ridge. Best of luck to you for being one of the only UA-cam roofers that posts a video and stays with it.

    • @RoofRepairSpecialist
      @RoofRepairSpecialist  11 місяців тому +1

      Thank you. I appreciate the support

  • @larrycrookshanks1646
    @larrycrookshanks1646 2 роки тому +2

    Air pressure is way to high for your nail guns the nails are sinking below shingle surface.

  • @martinzepeda6617
    @martinzepeda6617 2 роки тому

    When your ridge is longer than length of the roll do you just butt them up and continue?

  • @Jake.Gentry
    @Jake.Gentry 4 місяці тому

    Does this actually let the air out??

    • @RoofRepairSpecialist
      @RoofRepairSpecialist  4 місяці тому +1

      It does

    • @Jake.Gentry
      @Jake.Gentry 4 місяці тому

      @@RoofRepairSpecialist so I had that installed in my new garage last year and currently the temperature outside is 80 F and the inside is showing 125 F is that normal?

    • @RoofRepairSpecialist
      @RoofRepairSpecialist  4 місяці тому +1

      Do you have intake vents?

    • @Jake.Gentry
      @Jake.Gentry 4 місяці тому

      @@RoofRepairSpecialist yes from the soffits

  • @larrycrookshanks1646
    @larrycrookshanks1646 2 роки тому +5

    Do not waste your time on this vent. It is a subpar vent. Install only vents that have a wind baffle on both sides.

    • @RoofRepairSpecialist
      @RoofRepairSpecialist  2 роки тому +1

      What is the purpose of the wind baffle? can you give me a manufacturer you'd like, I'd like to look into it.

    • @landonlandon5533
      @landonlandon5533 2 роки тому +1

      Gaf.

    • @slippinslidewayz
      @slippinslidewayz Рік тому +1

      Gaf makes a great product for sure but we never had any problems or callbacks with the Owens Corning rolls.

    • @JPumpkinKing
      @JPumpkinKing Рік тому

      100% agree. I got the Ownens Corning corrugated garbage rolls on my roof 5 years ago, and my attic has never been hotter. No air movement. So, now I’m having to get bids to redo the ridge vents with a better quality product with baffles and a higher profile so air can actually move.
      I’m guessing Owens Corning is selling this crap because they know it will shorten the life of their shingles, and therefor create more sales due to roofs having to be redone more often.

    • @JPumpkinKing
      @JPumpkinKing Рік тому +1

      @@RoofRepairSpecialistif you’re a roofer and don’t know about ridge vents with baffles, how are you even in business? Ridge vents with baffles have been around for years! 🤦🏼‍♂️

  • @bulldogsandlife
    @bulldogsandlife Рік тому

    Awesome , detailed Video! Thank you so much, I going to attack it soon.

    • @RoofRepairSpecialist
      @RoofRepairSpecialist  Рік тому

      Good luck. I would love to see pictures of the process, tag me on FB or IG

  • @iinkpayments
    @iinkpayments Рік тому

    👏🏼🙌🏼

  • @mikegresham9424
    @mikegresham9424 8 місяців тому

    The plastic ridge is better than this one in video

  • @thomassmith2239
    @thomassmith2239 2 роки тому +1

    LOL. Ask your structural engineer if he wants you cutting a continuous 3" wide strip out of the plywood roof diaphragm at the ridge.

    • @RoofRepairSpecialist
      @RoofRepairSpecialist  2 роки тому +2

      Wait till you see an intake vent

    • @JPumpkinKing
      @JPumpkinKing Рік тому +2

      Tell us you don’t know anything about ridge vents without actually saying you don’t. 🙄

  • @JPumpkinKing
    @JPumpkinKing Рік тому +1

    That corrugated ridge vent is GARBAGE! If anyone has that crap on their hole, they’re NOT going to have effective air movement. I had that installed on our roof 5 years ago, and am currently getting bids to redo the entire ridge vent system with a system that has baffles and screens and has a high rate of air movement.
    If your roofer suggests this corrugated garbage, find a new roofer.

    • @RoofRepairSpecialist
      @RoofRepairSpecialist  Рік тому +1

      LOL

    • @Jeffs60
      @Jeffs60 Рік тому

      It's complete garbage so you need to repair every 5 years and mice will chew through that cheap stuff and you will spend even more money when they wreck your attic. My house is 1958 ranch, all it has was 2 gable vents and small box vent, no ridge vent, no attic fan, no soffits and there was never a problem, no mold or anything that is the way it was designed and that is the way it will stay when I get a new roof. Current roof is 23 years old so maybe in 5 years I get a new one.

    • @RoofRepairSpecialist
      @RoofRepairSpecialist  Рік тому

      Every house is different and every area is different. Some places have mice and rats that chew through flashings. Some places have squirrels that cause problems. Bottom line you need to know what works and doesn’t work in your area.

  • @denoca3261
    @denoca3261 Рік тому

    Can't rodents chew through the end caps? Baffled ridge cap is better.

  • @dontblameme6328
    @dontblameme6328 3 місяці тому

    That vent is total crap.

  • @coreyayers7933
    @coreyayers7933 Рік тому +1

    I listen to 43 seconds of stupid mansplaining before I left.

    • @RoofRepairSpecialist
      @RoofRepairSpecialist  Рік тому +1

      lol, I’ll go slower next time

    • @KidFreshie
      @KidFreshie 10 місяців тому +1

      I'm confused. How should he have explained how to do this?

  • @amerkhan4672
    @amerkhan4672 Рік тому +1

    Is it normal to get moisture/condensation inside on the ridge vent?

    • @RoofRepairSpecialist
      @RoofRepairSpecialist  Рік тому

      No, I have never seen that happen. I have seen leaks happen from improperly installed ridge vents all the time. But not condensation.