    @kukiechag99 2 місяці тому

    Hi Derek what is the ventilation requirement for a 10kw open flued water heater in a room with a volume of 10m3

  • @kukiechag99
    @kukiechag99 2 місяці тому

    Hi Derek ventilation for multiple appliances in a room , do we remove adventitious air for open flued appliances?

    • @tomkatgastraining
      @tomkatgastraining  2 місяці тому +1

      @@kukiechag99 you add all the kw together for each open flue appliance the minus 7 for adventitious air

  • @S-x124
    @S-x124 4 місяці тому +1

    isn't 2 DFEs in a through room 200cm2 or MI's

    • @tomkatgastraining
      @tomkatgastraining  4 місяці тому +1

      @@S-x124 nope according to the building regs f you have to add 35 cm2 for adventitious air because you can only have it for one appliance in the same room

  • @daguardarenelsilenzio7744
    @daguardarenelsilenzio7744 4 місяці тому

    Isn’t it right that if there are two appliances with the same flue are in the same room you add the Kw input and times by 5 and then remove the 35cm2 for adventitious air. If you did this for the two ILFE fires you’d require 34cm2 ventilation ?

  • @mortezakhesarat5364
    @mortezakhesarat5364 5 місяців тому

    Vent is not my favourite subject but you explain if very well ❤❤

  • @jasonbrooksbank
    @jasonbrooksbank 4 місяці тому

    Could you go through commercial gas ventilation. Direct and indirect burners. Radiant heater. Please

    • @tomkatgastraining
      @tomkatgastraining  4 місяці тому +1

      @@jasonbrooksbank commercial videos are not on my agenda to do yet sorry

    • @jasonbrooksbank
      @jasonbrooksbank 4 місяці тому

      @@tomkatgastraining thank you for your reply.

  • @sharazali-tabassam3033
    @sharazali-tabassam3033 Рік тому

    I done very bad on this one. More please 🤓