Quiet Check Valve For Sump Pumps - No Water Hammer Noise

Поділитися
Вставка
  • Опубліковано 1 жов 2024
  • Sump pump check valves stop the backflow of water, but the water hammer BANG needs a quiet check valve. The noise they make when they slam close can be heard through the house. Get one that is said to be “quiet”, “silent” or “soft close.”
    Zoeller makes a variety of them that only make a comforting “whooshing” sound.
    They will not be soundless, but they won’t bang either. Ask questions before you buy it for reassurance. I have used check valves that purport to be quiet even though they were not.
    To install, remove the section of pipe under the valve, and stick a screwdriver into the check value to release the water above the valve. Then loosen the clamps (or cut), switch check valves and replace the pipe under the valve. If there is a shutoff above the check valve, you won’t have to drain the valve.
    A home-size Zoeller quiet check valve is $20 - $30, and are worth the peace.
    www.mrhardware....

КОМЕНТАРІ • 28

  • @1new-man
    @1new-man 6 років тому +4

    That's unbelievably quiet. Thanks for the recommendation Mr hardware!
    always informative post.

    • @MrHardware1
      @MrHardware1  6 років тому +1

      It helps to have a friend testing some of this stuff. Never know who to trust these days.

  • @yanso5271
    @yanso5271 6 місяців тому +1

    My plumber says you want to hear that BANG noise to make sure that the pump is working properly. With that silencer installed, you won't know if the pump has failed until too late.

  • @bk9852
    @bk9852 6 років тому +3

    Now that is nice I am so tired of the BANG thanks!!

  • @pctechusa0505
    @pctechusa0505 3 роки тому +1

    I just installed one of these and I can't hear my sump pump eject water anymore! Incredibly quite. Thanks for the great video and check valve recommendation :)

  • @markochinegro1004
    @markochinegro1004 6 років тому +2

    This is exactly what I've been looking for!! Thank you!

  • @metalheadrelic9873
    @metalheadrelic9873 4 місяці тому

    Its not a bang or a click, its a loud thud.

  • @heystarfish100
    @heystarfish100 6 років тому +2

    It will change your life!

  • @tereseheinen9632
    @tereseheinen9632 7 місяців тому

    I just bought one but haven't installed it. My handyman said not to do it because when it needs to be replaced in a few years I'll have to cut the pipes that lead into it. Please help me understand how it will be replaced when it wears out. THANK-YOU !!!

    • @MrHardware1
      @MrHardware1  7 місяців тому

      It comes with a smooth piece of PVC, on either end that I used to Fernco coupling to clamp on to the pvc pipe. So when I need to change it, I can loosen up the clamps on the Fernco and slide the old one out. Also, if you look at the video you see it’s knurled on the ends, those are like unions, and those can be unscrewed because if you were replacing it with the same check valve, you would unscrew those nuts and not even have to touch the Ferncos.

  • @DetRiley
    @DetRiley 6 років тому +1

    adding amazon (or ??) links to where to purchase them in the description would be great. Having trouble finding a 4 inch valve.

    • @MrHardware1
      @MrHardware1  6 років тому

      Call the store, ask for Blair and give me the details of the plumbing and I'll get you a quote. 586
      775-9532

  • @waynegiddings
    @waynegiddings Рік тому

    I just got the Zoeller quiet check valve and it works great- quiet. Thank you Wayne

  • @bwrick21
    @bwrick21 Рік тому

    With an ejector pump like your. Does it needed to be vented to the roof or can it be through a side wall (no windows/doors intake in a 15ft area)

    • @MrHardware1
      @MrHardware1  Рік тому

      I believe sewage ejector systems, which is a sealed lift tank needs to be vented to the roof. I would check the local and building inspector for more guidance.

  • @hernandezcarrillo3159
    @hernandezcarrillo3159 2 роки тому

    Mine is still loud 😔

  • @00dahc
    @00dahc 4 роки тому +2

    I used a check value off the shelf at Home Depot for like 8 bucks. I don't hear a thing and it's been working for years. Title of this video caught my eye since I never heard an noise from it before.

  • @Rodj12341
    @Rodj12341 6 років тому

    The check valve is good...Except for that pump though, my grandparents have the same exact one and it makes the same humming sound that came be heard from upstairs.

    • @MrHardware1
      @MrHardware1  6 років тому +1

      Maybe a rubber coupling on the discharge line will prevent the pump from humming throughout the house.

    • @josemendoza-hj3ri
      @josemendoza-hj3ri 5 років тому

      Hi have problems not have presure the fitins or pump whats can do

  • @mikeh457
    @mikeh457 2 роки тому

    What did it sound like before?

    • @MrHardware1
      @MrHardware1  2 роки тому

      A bang like a book fell on the floor every time the pump stopped. Not a show stopper but annoying to say the least. Some plumbing telegrams the sound more than others.

  • @msbgone
    @msbgone 4 роки тому

    How is it 2 years later, ..... thanks.

  • @brianremson5176
    @brianremson5176 3 роки тому

    I used the zoller it went completely quiet ours was so loud I could not believe the difference, when it went off in the middle of the night that was all I could take. Not a bang at all. Hat is off to zoller I was a bit skeptical but it worked very well.

  • @jimbo8743
    @jimbo8743 4 роки тому

    👍

  • @TeslaRules1856
    @TeslaRules1856 5 років тому

    Why dont you need one on the backup ?

    • @MrHardware1
      @MrHardware1  5 років тому +1

      It has one built in. You must have one on all sump systems that lift water over a few feet. Plus with 2 pump systems the water will go back through the other pump as one runs.