D R C 's TXV disassembly, inspect and reassembly

Поділитися
Вставка
  • Опубліковано 14 січ 2025

КОМЕНТАРІ • 56

  • @sunwinwk3650
    @sunwinwk3650 10 місяців тому +1

    after 8 years there are still people to watch, the video is useful for me, you are the man, Thank you very much , I appreciated it.

  • @JaykeSapalaran-iq3qs
    @JaykeSapalaran-iq3qs Рік тому +1

    Great video tutorial 👍❤ thank you for sharing your knowledge and experience 🇵🇭🫡

  • @captainmigs1655
    @captainmigs1655 3 роки тому +3

    Perfect video my guy! Subscribed and plan on watching your videos. Keep it up!

  • @AliBaba-cf4iu
    @AliBaba-cf4iu 5 років тому +2

    Nice job man very thorough

  • @mikehardin7086
    @mikehardin7086 5 років тому +4

    Thank you for the video. I am concerned that I over heated a TXV, I will use your technique to inspect it before I charge system.

  • @Jpriatna
    @Jpriatna 5 років тому +2

    Yhank for sharing inspection exspansi valve

  • @pedrojardim1163
    @pedrojardim1163 5 років тому +3

    wow good staff

  • @DragonflyAcres2022
    @DragonflyAcres2022 3 роки тому +1

    Nice video thank for sharing

  • @ryanmalin
    @ryanmalin 7 років тому +3

    everytime that happens, just a suggestion, put a sight glass inside that case and write with paint marker "furthest case from rack" as it tends to be the futhest case from the rack. I also make sure if the case isnt feeding, close maybe half or 3/4 liquid ball valves (if not a loop system) then you can see if the temp drops and fixer quicker. Thanks for the video

    • @samho9318
      @samho9318 5 років тому

      Hello Ryan, I know this is yr. Old thread, but I must have to ask hopefully you can help me to better understanding of the ref. System

    • @samho9318
      @samho9318 5 років тому

      Sorry I hit the send button 🤣

    • @ryanmalin
      @ryanmalin 4 роки тому

      @@samho9318 hey man, get into supermarket refrigeration. Contact Hill Phoenix and ask them for some guidance to schooling or training in your area

  • @Gary-ts6dh
    @Gary-ts6dh 11 місяців тому

    3:45 - What did you use to clean the valve body? more contact cleaner? I guess that's ok for the refrigerant circuit?

    • @DRCProductions
      @DRCProductions  11 місяців тому

      Usually I don’t use cleaner but have no problem using contact cleaner because it dries up clean.

  • @eric4467
    @eric4467 8 років тому +2

    Thanks!

  • @Eljfroxs26
    @Eljfroxs26 3 роки тому

    ang galing nyo po

  • @jellytae6851
    @jellytae6851 2 роки тому +1

    When you clean Txv valve does need to vacuum suction line or either shout down unit and clean txv valve and put back together and turn unit back on ?

    • @DRCProductions
      @DRCProductions  2 роки тому

      Low temp you usually need to pull a vacuum. Any time you open up a system you should pull vacuum, this particular case had valves in the case so it was a quick evacuation. I cannot say that I have never done a quick purge and merge DRC method of reassembly of the valve. Sometimes valves are not holding somewhere in the system and there is always a slight positive pressure blowing by the valve during disassembly which I consider no air introduction into the system. Hence purge and merge. Always take into consideration of existing conditions.

    • @La2venida
      @La2venida 12 днів тому +1

      @@DRCProductionsso you pump it down and disassemble. Any txv that look like the one in video (at a 90 degree angle) has a screen?
      Also if you have a leaky past the valves, do you evacuate also and just make up for the lost gas?

    • @DRCProductions
      @DRCProductions  11 днів тому

      @@La2venida I pumped it down to 2 psi for constant positive pressure to keep the non-condensible out. No gas lost.

  • @l.crossjr
    @l.crossjr 2 роки тому

    Is there such a thing as a quick TXV test without opening the system?

    • @DRCProductions
      @DRCProductions  2 роки тому +1

      Use your your senses first
      Vision, is there frost on the pipe leaving the TXV?
      Touch, feel the valve for temperature differential.
      Hearing, listen - is the valve whistling, low charge?
      Smell, can you smell refrigerant?
      Senses will get the obvious and use meters and gauges for verifying your god given senses. Cheers!

  • @HVACRSurvival
    @HVACRSurvival 8 років тому +1

    What was determined to be the problem? Powerhead or improper superheat adjustment?

    • @donalddperez
      @donalddperez 7 років тому +2

      ucantstopthis1
      This system was low on charge. It happens.

    • @marks9935
      @marks9935 6 років тому +3

      Really? And you couldnt figure that out without dismantling the TXV?

    • @DRCProductions
      @DRCProductions  6 років тому +3

      Knew it was low on charge, wanted to make a video.

    • @SombraLocs
      @SombraLocs 6 років тому +1

      @@DRCProductions Would it frost up on the capillary tube side if it was not feeding properly?

    • @u2ooberboober
      @u2ooberboober 4 роки тому +1

      At least now I know to pump down the system before removing the power head!!

  • @emergencyexit2510
    @emergencyexit2510 5 років тому +2

    tnx

  • @ninosanchez8798
    @ninosanchez8798 3 роки тому

    Didnit work or not?

  • @Bluecollarrebel
    @Bluecollarrebel 4 роки тому

    Nice

  • @나홀로할베-f2d
    @나홀로할베-f2d 6 років тому +2

    I think that freezer have refrigerant leaking problem.therefor got moisture through the leaking point. maybe TXV clogged by moisture freeze up and refrigerant got high friction through the TXV. maybe moisture was not enough to make 100% clogged the TXV. if TXV got 100% clogged, and then freezer food will be melting and freezing and melting.

  • @MALIKA544
    @MALIKA544 4 роки тому +2

    normalement le bulbe du detendeur doit etre isole thermiquement pou r donner la valeur reelle de la temperature de la tuyauterie d asoiration , sinon , une bonne video

  • @guangxfang1477
    @guangxfang1477 3 роки тому

    Is Sporlan KT-43-SZ Expansion Valve Element 60" use for walk-in freezer?

    • @dbp1926
      @dbp1926 3 роки тому

      yes.
      KT=Kit
      43 = the size of element
      S = Refrigerant Type
      Z = Low Temp

  • @Salmanksong
    @Salmanksong 5 років тому +1

    Sir, we have turned on contractors by doing this, after that the contractor turns off, after that we put the charging line on the section, then its pressure goes to vacuum and the discharge pressure is 200 stand nor forward or backward.

    • @DRCProductions
      @DRCProductions  5 років тому +1

      Hi Khan

    • @DRCProductions
      @DRCProductions  5 років тому +1

      Did you figure it out?

    • @Salmanksong
      @Salmanksong 5 років тому

      Yes sir please suggest me

    • @DRCProductions
      @DRCProductions  5 років тому +1

      Salman Khan sounds like you have a redistribution somewhere. Valves open? Drier plugged? Solenoid valve energized?

    • @DRCProductions
      @DRCProductions  5 років тому

      Old unit or a newer one?

  • @UltraHydrophobiccoat
    @UltraHydrophobiccoat 5 років тому +1

    No nylog blue needed for the threads?

    • @DRCProductions
      @DRCProductions  5 років тому +1

      Superhydrophobic Coating not that day. 👍

    • @DRCProductions
      @DRCProductions  5 років тому +1

      Superhydrophobic Coating I like Loctite 567. That sealant is the kind

    • @bmillwood6666
      @bmillwood6666 3 роки тому

      Nylog was not around five years ago

  • @Ihartdabears85
    @Ihartdabears85 6 місяців тому

    Hate when they use dye multiple times knowing the txv is there. Stratus for the sniffing win. H10 not too bad just a big ole gal

  • @hugovalenzuela6669
    @hugovalenzuela6669 3 роки тому

    If my a remplace the txv

  • @airmech5083
    @airmech5083 3 роки тому

    Shut the case downstream, if this case temp start dropping ya low on gas.

  • @automatictrader7913
    @automatictrader7913 4 роки тому +1

    thats right go hulk on it so the next guy will have to cut open his fingers to loosen it

  • @bmillwood6666
    @bmillwood6666 3 роки тому +3

    Power heads are cheap. Always replace power heads when working on a txv.

    • @steve0826
      @steve0826 3 роки тому

      Just replace with any power head, or there are some specifications to pay attention to?

  • @Salmanksong
    @Salmanksong 5 років тому +1

    50 tan packeg ac carrier

  • @lancerudy9934
    @lancerudy9934 5 років тому +1

    The screen is clogged

  • @Salmanksong
    @Salmanksong 5 років тому

    Please answer

  • @javiertrejo2694
    @javiertrejo2694 4 роки тому

    mmmm 2 dos