How To Perform Proper Annual Maintenance on Weil McLain Ultra 3

Поділитися
Вставка
  • Опубліковано 20 жов 2024
  • Do you service Weil McLain Ultra gas heating boilers? Do you have a Ultra in your home? This step by step instructional video guide is a MUST watch!
    Please take a moment and click that 👍 button! Much appreciate the support from the community.
    Check out my Uncensored channel: / mikeypipesuncensored
    Oval raised silver stickers are from:
    Armored Decal Company Inc.
    35 Victoria St. E, Unit 9
    Alliston, Ontario L9R 1T3
    (p) 705-435-6665
    (e) ken@armoreddecal.com
    (Tell them Mikey Pipes sent you)
    Please support this channel and Mikey Pipes and consider the following…
    UPDATED: 10/19/22 Pipe Doctor & Bosch long sleeve shirts are available in sizes LARGE, XL & 2XL
    Minimum donation of $21 is appreciated. Or (2) for $35 delivered within the US.
    Shopping on Amazon? Please use my referral link amzn.to/2PjjS4v
    Sticker Requests:
    Do you want a sticker to show your support of this channel? Email your request to me! mike@mikeypipes.com
    Name
    Address
    City, State, Zip
    Consider making a donation of $5.00, or ANY amount, to the postage fund! I literally mail out stickers all over the globe. I've sent stickers to HVAC guys in Afghanistan, New Zealand & all over Europe.
    PayPal is: office@pipedoc.net
    Venmo: @PipeDoctor
    CashApp: $mikeypipesny
    Want to send a love letter, note or gift? Our mailing address is:
    Mikey Pipes
    C/O Pipe Doctor Home Services, Inc.
    80 E Hawthorne Ave
    Valley Stream, NY 11580
    Join our team! PIPE DOCTOR HOME SERVICES is expanding to the great State of South Carolina!
    WE ARE ACTIVELY HIRING:
    SERVICE PLUMBERS
    HVAC TECHNICIANS
    DISPATCHERS
    For our location in:
    NORTH CHARLESTON, SC
    Email me: mike@mikeypipes.com your interest. Relocation assistance is available!

КОМЕНТАРІ • 60

  • @mattwittneben443
    @mattwittneben443 Рік тому +2

    Really admire the way you’ve taken Peter under your wing. Being patient with him and explaining things. Great job as always.

  • @gregorygalati3435
    @gregorygalati3435 Рік тому +2

    Hey Mike. I took a boiler coarse with a few guys that know you, Ivan from weil McLain was one. We discussed the ignitor gasket that supposedly doesn't come in the boiler kit anymore actually is hidden in the little inhibitor box. I asked in class what was up with that and they explained in gets less damaged in box. Sooooooo they are still there. I talked you up buddy, and because of your videos, I looked like a pro. Thanks pipe doctor.

  • @bjive5900
    @bjive5900 11 місяців тому

    A great teacher…. As a 5year guy still trying to gain as much knowledge as possible i really appreciate it.

  • @giulianosalvatore1084
    @giulianosalvatore1084 Рік тому +4

    The maintenance kit directs you to start cleaning on the bottom, not the top as you have done.

  • @berylwhite2983
    @berylwhite2983 Рік тому +2

    As always I'm very impressed with your work! But in our area the boilers are so old it makes that thing look like a cute water softener. For the first couple times I thought it was a water softener when I seen you guys working on it and I didn't understand what you were saying. Of course you know I'm in repair at all. I'm just interested in how nice you treat your customers. Keep up the great work (I think I figured out why we have very few new boilers. Most homes are going to high efficiency deducted heating and cooling and even I like our high school has went to ground water heat pump .)

  • @giulianosalvatore1084
    @giulianosalvatore1084 Рік тому +2

    Directions say to use a torque wrench.

  • @ScottGriffith-o6f
    @ScottGriffith-o6f 10 місяців тому

    Great video!! I just started working on these as of yesterday 12-13-23 and this video is a big help. Maybe a video on setting them up with outdoor temp compared to supply temp. Thank you!!

  • @gjan1761
    @gjan1761 Рік тому +2

    I have an Ultra 80, 13 years old. I definitely didn't save any money over the old cast iron boiler, once you add up all the maintenance costs. Is there a worth alternative or just go back to cast iron?

  • @giulianosalvatore1084
    @giulianosalvatore1084 Рік тому +5

    Maintenance manual directs you to use the sword at 0 degrees(straight on), then +45 degrees then -45 degrees. Read the manual, before making a video on proper maintenance.

  • @realestateservicessaleshea99

    Very professional!
    I will more than likely purchase a high efficiency WHJ for myself, but I would never give myself a headache putting one in a customer's home.
    That is an expensive service call!😂🤣😂🇺🇲
    Stay safe
    Wear your safety glasses!
    🍺🍺🍺🥃🥃

  • @matthewviti2241
    @matthewviti2241 Рік тому

    I remember this one from last year. Great video.

  • @NytefogNJ
    @NytefogNJ 9 місяців тому +1

    Should be torquing the burner plate/front HX cover bolts with a torque wrench in the specified pattern found in the manual, Dr.

    • @josephfarley3526
      @josephfarley3526 9 місяців тому

      I have found that torquing the nuts at the prescribed 50 inch pounds is scary because the bolts will snap. They know this because they come with the cleaning kit. I’ve asked Weil McLain about this with no concrete answers. But if you read the Manual on page 111 for Ultra 155 - 399 line #13 it actually says “ the final torque MUST NOT exceed 50 inch-pounds +/- 10 inch-pounds.So they are saying tighten the nuts in the correct pattern but don’t exceed that number. But it doesn’t say torque To 50 inch-pounds very vague.

  • @eddiew.6485
    @eddiew.6485 Рік тому +1

    Nice job as always, Mikey👍. Kudos to Peter, but he should have went Trick-or-Treating with the Latinas Chickas😁

  • @jonwillis9075
    @jonwillis9075 Рік тому

    Thanks for the midnight snack! Sincerely, well fed

  • @eastcoast186
    @eastcoast186 Рік тому

    Weilmclain redesigned exhaust tail piece to collect and direct condensate right into trap to solve the deterioration of bottom of heat exchanger around 10 years ago

  • @johnwalker890
    @johnwalker890 Рік тому

    Good job Mike and Peter.

  • @Mike-cc3bc
    @Mike-cc3bc Рік тому

    Agree totally. Changing the block on those units is no fun. Especially since a yearly service like you did is all that's needed to help prevent it.

    • @Mike-cc3bc
      @Mike-cc3bc Рік тому

      Awesome. That is the first time I've seen one mounted on the wall like that. 👍

  • @stanleyedwards3023
    @stanleyedwards3023 Рік тому

    My ultra 155 lasted 23 years before it started to rot, I serviced it every year and replaced inducer fan Assy and control board once. All in all a good unit. I did torque to 50 in lbs in sequence the cover plate as in the manual though. Stan.

    • @DerbyDogz
      @DerbyDogz Рік тому

      Yeah, ran into a few of these with cracked off ears on the cover plates due to people over tightening them.

    • @Efungable
      @Efungable 14 днів тому

      Hi may I ask where are you located and how much did it cost you for the yearly maintenance. I just bought a house with the HE Boiler like this one and I’m learning how important it is to service yearly.

  • @giulianosalvatore1084
    @giulianosalvatore1084 Рік тому +4

    The instructions direct that you use the sword in the straight-thru mode, then at +45 degree, then at -45 degree. Come on Mikey, read the directions.

  • @johnnypena9682
    @johnnypena9682 Рік тому +1

    Nice job keep doing good job

  • @kingbulldog107
    @kingbulldog107 Рік тому

    i maintenance 5 of those a day, very important to shut off and get tools ready while it cools down before opening heat exchanger cover plate so it dont crack at bolts.

    • @kingbulldog107
      @kingbulldog107 Рік тому

      also try going down on a 45 degree through baffles with the sword

    • @kingbulldog107
      @kingbulldog107 Рік тому

      @@PipeDoctor 1 team one dream Michael!!!

  • @ADOENDRA
    @ADOENDRA Рік тому

    You could add a transparent Plexi as temp. cover , this way you can flush the heat exchanger full power with water. In the meantime it is automatically flushing, you can clean the real cover. ( what Peter was doing )

  • @eduardorodriguez-ei4mw
    @eduardorodriguez-ei4mw Рік тому +1

    MUY BUENO CLASS. PROFESOR

  • @rogersamaniego7392
    @rogersamaniego7392 Рік тому

    How much is maintenance for this particular boiler?

  • @greekmaster1001
    @greekmaster1001 5 місяців тому

    I got same flashlight got for all my workers also

  • @billmiller5075
    @billmiller5075 Рік тому

    Nice job

  • @OttawaMale43
    @OttawaMale43 10 місяців тому

    Unfortunately the burner and plate were put on someones floor and WM stipulates you need a resperator while using the "sword" and changing gaskets because of as you said earlier that the condensate is acidic. You didnt torque your burner plate bolts...the plate will warp now because of uneven torquing on each bolt

  • @chuckquinn8026
    @chuckquinn8026 Рік тому

    Nice. BTW Mikey, Pipe Vice has new hand tools: Micro 5 and Micro 10. Check them out.

  • @kevinkrug466
    @kevinkrug466 3 місяці тому

    Where do you get the sword?

  • @Jimbobo162
    @Jimbobo162 Рік тому

    What kind of annual maintenance does a heat pump need. Besides cleaning the outside unit.

    • @Jimbobo162
      @Jimbobo162 Рік тому

      @@PipeDoctor the manual says to consult a professional. I don’t think they need much maintenance.

    • @Jimbobo162
      @Jimbobo162 Рік тому

      @@PipeDoctor I have a Lennox. I’ve only had one “service” in 12 years because the outside fan wasn’t running. Come to find out it doesn’t run in defrost 🤦‍♂️🤦‍♂️🤦‍♂️

  • @tomwhitaker5673
    @tomwhitaker5673 Рік тому +2

    You didn’t clean the heat exchanger properly. You need to “sword” it on an angle not just straight in. You’ll clean it so much better.

    • @John-ss8tu
      @John-ss8tu Рік тому +2

      Exactly. He only cleaned 33% of it. It has to be cleaned with the sword at a 45 degree angle upward and at a 45 degree angle downward. A total of 3 orientations. Not just one. This is shown on Page 90 of the manual.
      www.weil-mclain.com/sites/default/files/field-file/ultra-series-3-manual_1.pdf

  • @flyingmachineworks
    @flyingmachineworks Рік тому

    Great to see people doing things the right way. I have to wonder what cost of 20 year ownership is between a gas high efficient unit and a standard boiler. Obviously you’ll save on the utility bill but maybe lose on the yearly maintenance costs?

    • @josephfarley3526
      @josephfarley3526 9 місяців тому

      You are not saving money! You are lessening your carbon imprint. People always equate high efficiency with saving money. Not true 25 years is tops for this boiler life opposed to dumb boiler last you 50 years!

    • @dwaynesykes694
      @dwaynesykes694 5 місяців тому

      @@josephfarley3526 you are lessening your bank account with high efficiency and making the executives and shareholders of the companies producing "high efficiency" equipment rich enough to fly around on private jets and heat their three mansions along with in-ground pools even when no one is there. Your personal "carbon footprint" is negligible compared to theirs. It's about money, not carbon dioxide. Want to be green? Burn all the fossil fuels you can to increase the CO2 levels on Earth, because historically they've been much higher than they are now. The Sahara Desert was once a rainforest... when CO2 levels were much higher.

  • @eddiew.6485
    @eddiew.6485 Рік тому +1

    #RedWave

  • @steveblake8766
    @steveblake8766 Рік тому

    220 thumbs up

  • @jasonflynn3972
    @jasonflynn3972 Рік тому

    Can I get a test ride in the 992

    • @jasonflynn3972
      @jasonflynn3972 Рік тому

      In the wifes pocket book. Nothing done without permission. I'm more of the cash type. Lol. I love your videos. Very hands on. Can I send you and your crew gift cards?

  • @arielhernandez2911
    @arielhernandez2911 Рік тому

    The red carpet vip

  • @michaelsmith9034
    @michaelsmith9034 Рік тому +3

    All condensing boilers, 10 year boilers, should be banned.

  • @CP-up8qz
    @CP-up8qz Рік тому

    Did that maintenance kit not come with a new flue sensor gasket? I just did a 399 and my kit had one in it

  • @xzibit8614
    @xzibit8614 Рік тому +2

    Peter needs to think 5 steps ahead, not just what’s in front of him at that moment.

    • @patricks950
      @patricks950 Рік тому

      Time to step up to the plate or miss the pitch

    • @Mike-cc3bc
      @Mike-cc3bc Рік тому

      He's learning. It comes with time.

  • @jasonflynn3972
    @jasonflynn3972 Рік тому

    2nd

  • @DevinHVACInc
    @DevinHVACInc Рік тому

    Food!!!!

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC Рік тому

    Those are the worst heat exchangers....very easy to access and clean...but garbage nonetheless

  • @scottmaz4063
    @scottmaz4063 Рік тому

    You should get a 1 gallon pump sprayer, alot less messy?