That's sooo cool! I was wondering how copper could melt so quickly with that small sized welding torch... I think the phosphorus in the brazing rod helps in melting the copper.
OG AC யை பொருத்தவரை Outdoor unit க்கு தான் மெயின் சப்ளை செல்லும். அங்கிருந்துதான் Indoor unit க்கு சப்ளை வரவேண்டும். நீங்கள் கொடுத்தது போல சப்ளை கொடுத்தால் Indoor pcb Board தாங்காது. மேலும் Outdoor ல் Compressor ஆன் செய்ய தனி coductor வரும். அது உங்கள் ac ல் missing. அதை வாங்கி போட்டிருந்தால் உங்க ac super ஆக ஓடியிருக்கும்.
1. The rod used for sealing the holes is called filler metal rod. It is primarily made up of copper(around 70%) but also contains other metals like nickel. Exact composition will vary from type and brand. It will melt at a lower temperature than pure copper and prevent the tube from melting. The process is called brazing. It is higher temperature than soldering but lower than melting point of copper.
Assalamualaikkum bro first inverter pcb non inverter lea work panathu aena inverter pcb communication oru signal matu varum.OG ac lea outdoor unit lea contractor irukkum.coil amp 2to 3 amps.
ப்ரோ நீங்க சொன்னீங்க கம்ப்ரஸர் பிரஷர் மூலமாக தான் லீக் செக் பண்றேன் என்று அது ஒரு தப்பான முறை ஏனென்றால் கம்ப்ரஸர் பிரஷர் அட்மாஸ்பியர் ஏற தான் உள்ள செலுத்தும் அந்த அட்மாஸ்பியர் ஏரில் மாய்ஸ்டர் இருந்தால் காப்பர் பைப்புள்குள் நீர் துளிகள் தேங்கிவிடும் பிரபு நீங்கள் கேஸ் ஏத்தும் போது அது அடைப்பு வருவதற்கு வாய்ப்புகள் அதிகம் உள்ளது
அந்த ac க்கு indoor pcb ல compressor line கொடுக்க கூடாது. Out door unit ல contector போட்டு wiring கொடுக்கணும். அந்த pcb ல foult கிடையாது. அது invertor pcb கிடையாது. நார்மல் pcb தான்.
outdoor unit la contactor use panni pannalam maybe antha technician kku AC work theriyathu , control wire go to outdoor contactor then power supply direct to the contactor
outdoor la oru single pole conductor poturuntha ready aagirukum rs750 Direct relay output kudutha relay poirum Relay output conductor coil supply kudukanum O general A/c best branded A/C
Outdoor door single pole contactor pottu pcb communication wire ah coil contact ku pottutu main phase ah contactor input thanthu output ah compressor kodutha odum
Bro i am doing airconditioner pcb service at madurai. Its simple fault only. U must use contacter in outdoor unit. சகோ நீங்க வீடியோல காமிக்கிற பிசிபி வந்து நார்மல் பிசிபி தான் நான் மதுரையில் பிசிபி சர்வீஸ் சென்டர் வச்சிருக்கேன் வீரா எலக்ட்ரானிக்ஸ் நீங்க சொல்ற complaint எனக்கும் நிறைய வரும் இதை சிம்பிளா சரி பண்ணலாம்
Bro intha video fulla pathen antha tecnical person mela tha ella thappum Ac leek irukku nu santhegam iruntha atha ac ya fast installation pannirukka koodathu keela vachi vera oru copraser la irunthu pressure vachi check pannanum next antha ac la gas line rendu irukkum atha thani thaniya form pottu apram mela roal suthanum Ac emty la ran agum pothu over load edukkum atha fuse poguduchi fuse pachi na compressor ah heat agidum atha cool pannittu same fuse ah mathanum athaum olunga seiyala ithalam theriyala oru technician na kopttu irukkinga
Na last yr (new) O General la dhan 1.5 ton Non Inverter AC vangunen. Service la nalla dhan panranga. Relative vetla koda 2015 la irundhu same spec la nalla dhan odudhu (with proper maintenance & service). In my POV, OG is best.
Naa blue start la 8k ku 2nd ac vangi 5 years use panni erunken, then now scrap ku 3000ku potean. Some time it will save money, luck erutha nalla ac kidaikalam
Don't buy marq AC ... i have to used last 2 years.. some complaints are raised like LED not working, automatically turn on and turn off indoor unit... it's Indore PCB board problem.... after 2 years you have to face these problems 😅 so please mind it
bro indoor and outdoor same model uh athodathu dana pathu vanganum ...til now i have supplied so much 2nd hand ac ... pressure test ellam panni dhan sale panirkom ...podhuva ipdi solla koodathu 2nd hand ac vangadhinga nu..plus 2 free service oda..
10:28 Out door la oru 220v contactor coil missing bro oru contactor vangi potrundha matter eppovo solve...aana kennedy annan pavam...(customer ku micham pannanum nu material la micham panna koodathu ) 100 la 90 customers innocent தான்
நண்பரே உங்கள் வீடியோவை பார்த்து முடித்து விட்டேன். ஆனால் இந்த ஏசியில் எந்த ஒரு பழுதும் இல்லை நீங்கள் சொன்னது மாதிரி 3 AIIMS relay normal AC இல் வரும் pcb தான் இது inverter model AC board இல்லை. பொதுவாக எல்லா ac ல் 10 arms relay இருக்கும் ஆனால் o general AC இல் stabilizer இருந்து வரும் output நேரடியாக outdoor க்கு செல்லும் . அங்கிருந்து indoor க்கு 220 v வரும் indoor இருந்து கம்யூனிகேஷன் outdoor க்கு வந்தவுடன் outdoor இல் contactor coil activate ஆகும் பின்பு compressor run ஆக ஆரம்பிக்கும் . Outdoor க்கு indoor இல் இருந்து output director compressor க்கு கொடுக்கும் போது இந்தப் பிழை ஏற்படும் board AIIMS பத்தாமல் short circuit ஏற்படுகிறது தெளிவுபடுத்தி இருக்கிறேன் என்று நம்புகிறேன் By 'sign Appliance care' Service Chennai
Hi . Bro . Actually..that 3 Amps relay contact . Supposed to connect power relay or motor contactor (A1) power only .i mean coil supply. Then 4 sq mm wire to be separately take via motor contactor .
Thanks for this video, broo I need one help na oru laptop vangalamnu irukae under 60k Oru nalla laptop suggest pannunga for work purpose only no gaming But latest future irukuramarii
I'm from Sri Lanka, and I run a small electronics shop. I also purchased a used AC, and the same issue occurred with it. I had to repair it several times and finally had to replace the entire outdoor unit. After a while, problems started again, this time with gas leaks from the indoor unit. So, I decided to purchase a brand new AC, and now it's working fine. The best thing is that I learned a lot from that experience, and now I am reselling AC units in my shop.
நான் Ac என்ஜினியர் தான் இதுல ஒரு ஆறுதலான விஷயம் என்னவென்றால் உங்களுக்கு வந்த டெக்னீஷியனும், நான் பார்த்த எல்லா டெக்னீஷியனும் ஒரே மாதிரி தான் இருக்காங்க... நல்லா ஓடும் சார், செமயான மிஷின் நீங்க போங்க நான் இன்ஸ்டால் பண்ணிட்டு கூப்பிடுறேன் சொல்லுவாங்க 😅.. காரனம் இது தான் 👇 இதுல இன்னொரு ஆச்சரியம் என்னவென்றால் இவர்களுக்கு நைட்ரஜன் பிரஷர் test என்னவென்றே இவங்களுக்கு தெரியாது . ஆன நீங்க ரொம்ப பாவம் பாஸ் உங்களுக்கு ஏர்ல பிரஸர் டெஸ்ட் பண்ணி இருக்கார் 😂😂😂 அப்படி பண்ண கூடாது ஏனென்றால் கம்பிரசர் ஓடும் போது டிஸ்சார்ச் பிரஸர் ரொம்ப அதிகமா இருக்கும்.. அதை நைட்ரஜன் வச்சி பிரஸர் அடிச்சா தான் சரியா கண்டுபிடிக்க முடியும் ஏர் அடிச்ச முடியாது.😅
Out door unit la oru contactor podanum and 1st outdoor ku power poganum next Anga irudhu indoor ku power varanum next out put outdoor la iruka contactor coil supply pona contactor moolama main power compressor ku pogum apa unit normal la work agum. Indha video paakum bodhu power and control wiring dhan problem
na LG 2 ton old ac buy panna 15000 thousandku but athu fitting + gas sethu 10000 thousand aitu 6 month kulla Gas thiruba paitu secondand Ac is too too Worst
Relay load கம்மி பண்ணுறதுக்கு outdoor la ஒரு 220v 2pole condector ஒன்னு ஃபிக்ஸ் பண்ணி modify pannina ok... Relay ku load varadhu.. ella load um conductor ku poyirum
Bro antha outdoor la Single Pole Magnetic Contactor Relay varum bro or indoor pcb rotary compressor pcb ah erukum bro. So athanala tha pcb load edukala bro.
For off site/in home leak check vaccumming is done with vaccum pump till pressure drops to zero, now while waiting for 15 - 20 minutes if the pressure is same(unchanged) no holes in tubes both in odu & idu, if the pressure increases to equalize the outer pressure then there is leak somewhere. In workshop nitrogen is pressurized (higher than working pressure) into the system and lowered in water tank to see for any bubbles even very tiny holes can be found out and blazed/welded accordingly. Im not AC mechanic 🧰
இந்த வீடியோ ல இருந்தே தெரியுது உங்களுக்கு மின்னணுவியல் பற்றி இன்னும் நிறைய தெரிந்து கொள்ள வேண்டும் என்று... Fuse failure ஆகி விட்டால் short செய்ய கூடாது. அது main component இல்லை எனவே அதன் current rate ஐ விட அதிகமாக கடத்த காரணமான உறுப்பை கண்டறிந்து பழுது நீக்க வேண்டும். Multimeter, oscilloscope, ஐ வைத்து testing பண்ண தெரிந்தால் மட்டும் போதாது... Root cause analysis செய்யவும் தெரிந்திருக்க வேண்டும். அந்த pcb ல் bridge rectifier தான் fault ஆக இருந்திருக்க வேண்டும்.
Bro atha ac vanthu piston compressor outdated and not very energy efficient avaka oru 4000 rs atha vagirpaka.antha brazing panna rod tin and lead combostion may be brass rod kuda use panalam
Ji.. apdi illa... relay kkum just a Contact point dha... initial load kkum..... running load kkum vidhyasam irukku.. once ungalukku compressor on aagiduchuna.. ivalavu edukkadhu... gas illadha po... compressor load aagum.. bayangarama... adha ungalukku ipdi vary aagirukku... gas and temperature very very important...
Hi bro ....indoor pcb la oru problem ella .,,ac lam nalla tha erukku bro, outdoor ac unit la oru single phase contact spar and wiring error tha mistake .... So problem ac la ella entha ac anuppuna shop owner and vantha installation person tha Mela tha issu.....gas leak check panna n2 tha use panna nu ....idl prassor potta compressor problam vanthutum and vellding work appadi panna kudathu.....ella work kkum sariya panna ac proper aa work pannum I am a A/C TECHNICIAN
Naan second laptop vaangaponen advance 10000 kuduthutu vandhen Nalla Vela apram set aagama naan vangala Apram konjam naal kalichi new one vaangi 4 years aaguthu ippo kuda SSD 4 years ku Mela aagium boot time kuda 5 seconds aavudhu
1. To check the leak of the refrigerant pipes and coil circuits, sop to do fill the nitrogen gas and kept it for 24hr to check the leakage. 2. After confirming that there is no leakage, to exhaust the nitrogen gas by vacuuming the gas through vacuum pump. 3. Then can topup the refrigerant gas into the system. 4. There should be separate thermal insulation for liquid and gas pipes. This may helpful for future use.
Bro Second AC வாங்குறப்போ apearance ah mattum paathu vaanga ma..Indoor coil and outdoor coil and indoor and outdoor PCB control boar and compressor condition எல்லாம் ஒரு நல்ல technician ah kootitu poii பார்த்து வாங்கினால், குறைந்த பட்சம் 7 years garentied ah எந்த complaint um வராம run aagum.. கம்மி விலையில் கிடைக்குதுனு வாங்கினால் இந்த problems varathan செய்யும்
Same O General AC , aana idhu engaludhu ,12 years nalla irundhuchu, veedu shift pannum podhu idhe madhiri oru local AC mechanic service, welding ,gas( cooling), installation solli 3800+ New pipe 3500 rupees, total 7300 rupees kuduthu ellam fit pannadhuku appuram cooling suthama illa, split Ac close aaga mattengudhu, enga kaasu 7300 rupees waste ,30000 value irundha AC pochu , nalla experience irukkura AC technicians vachu AC service or Installation pannunga
Outdoor unit la oru two pole contactor 15A thangura mari potu vittu irundha indha problem solve pannitu irukkalame thalaivare. Reciprocating compressor lam intha time la kedaikave kedaikaadhu. But power jasthiya sapidim...
There is norms for every fuse depending upon wattage which we used or designed. So removing the fuse connecting with heavy wire may result damaging other parts.
@Engneering facts oudoor unit la relay onu vachutu. Pcb output ah oudoor rely ku poitu run aguramathiri. Atha relay ku direct ah phace kuduthurunga. Pcb output relay ku ponathum outdoor start aydum so no more panic
Bro outdoor ல் realy contactor இருக்கும் முதலில் கரன்ட் outdoor க்கு போகும் பிறகு indoor pcbல் வரும் சிக்னலனாலால் realy contactot ஆப்ரேட் ஆகி outdoor runஆகும்
விபரம் தெரிந்த நீங்கள் நன்றாக பரிசோதித்து வாங்கியிருக்கலாம்.நமக்குதான் எல்லாம் தெரியுமே என்ற அலட்சியம் நான் உள்பட..விபரம் தெரியாதவர்கள் installation with warranty யுடன் வாங்குவார்கள்.இது உங்களுடைய அலட்சியம் தான் காரணம்.அல்லது விலையை நன்றாக குறைத்து வாங்கவேண்டும்.அனுபவத்தை பகிர்த்தமைக்கு மிக்க நன்றி.
I bought a second hand AC for my mom's room. 1.5 ton for 15k at sapthagiri enterprises, Kodambakkam, chennai. Indoor unit was Blue star, outdoor unit was LG. My mom used it round the clock, it was like seamless and super chill. I hardly serviced it once in an year only. Its been 4 years now it is still working but my mom is no more. 😢 That second hand AC was the best thing ever i bought for my mom.
Brother inime ethavathu perusa vangaraku munnadi oru video podunga, nanga irukko research panni solle appurama oru decision eduthu vanguvo deal ok va 🥰🥰🥰
Bro first copper pipe insulation pannathea thappu section pipe and decharge pipe line thani thaniya insulation pannanum next out door la 20 A conductor relay fix panni iruntha ac in door PCB problem vanthu irukathu antha ac fix Panna Anna kum athu theariyathu Pola
ஒருமுறை AC repair நானும் online ல பாத்து service க்கு கூப்பிட்டேன் வந்து check பன்னிட்டு board service பன்னனும்னு 4000 ரூபாய் வாங்கிட்டு ரெடிபன்னியாச்சுன்னு கொண்டு வந்து மாட்டுனான் ஆனாலும் ஓடல அப்புறமா inverter லயும் ப்ராப்ளம் னு சொன்னான் அப்புறம் போயி inverter ready பன்னதும் ஓடிச்சு. ஆனாலும் அவன் boardலயும் problem தான்னு சாதிச்சிட்டான். பழைய பொருட்கள் வாங்கறதிலையும் ரிப்பேர் பன்றதிலையும் எச்சரிக்கையா இருங்க.
Bro you did a huge mistake on buying Marq Ac, they will not bother customer after warranty is over and Jeeves service is very poor. I complaint many times very very irresponsible answer from call centre as well as Jeeves
உங்கள் அனுபவத்தை அடுத்தவர்களுக்கு பாடமாக எடுத்துச் சொன்னது உங்களின் தனி சிறப்பு ❤
That's call Brazing rod. Silver 15% copper 80% phosphorus 5% bro.
That's sooo cool! I was wondering how copper could melt so quickly with that small sized welding torch... I think the phosphorus in the brazing rod helps in melting the copper.
Dont buy second hand ac or fridge.... எனக்கு exp அதிகம்
பழைய பொருள் எல்லாமே வேஸ்ட் தான்,
@@praveenkumartamil8982true but onama illa erukarathu waste is better for many people bro❤
Namba ah pathu vanganum bro avlotha ac panel open pani pakanum nanum 2nd business tha panura ah ipovara crt ah oduthu
Bro neenga ac repairing aah panreenga bro
Yes I too exp
OG AC யை பொருத்தவரை Outdoor unit க்கு தான் மெயின் சப்ளை செல்லும்.
அங்கிருந்துதான் Indoor unit க்கு சப்ளை வரவேண்டும்.
நீங்கள் கொடுத்தது போல சப்ளை கொடுத்தால் Indoor pcb Board தாங்காது.
மேலும் Outdoor ல் Compressor ஆன் செய்ய தனி coductor வரும். அது உங்கள் ac ல் missing.
அதை வாங்கி போட்டிருந்தால் உங்க ac super ஆக ஓடியிருக்கும்.
Super.. Boi..Super ana Technical information🎉🎉🎉
Correct
AC வாங்க நினைக்க முயற்சிக்கும் சார்பாக இந்த வீடியோ வெற்றி பெற வாழ்த்துக்கள்
Thanaku viboothi adikapatathai unargirar 😂❤
Video fake viboothi adigraar iyya
Namma bhai ke kulambu potuttapla 2nd hand sales bhai
Adaie 😂😂😂😂
😂
அண்ணனின் திறமையை பாராட்டி கம்பெனி வழங்கும் அதிசயபொருள்
😅😅
😂😂😂
1. The rod used for sealing the holes is called filler metal rod. It is primarily made up of copper(around 70%) but also contains other metals like nickel. Exact composition will vary from type and brand. It will melt at a lower temperature than pure copper and prevent the tube from melting. The process is called brazing. It is higher temperature than soldering but lower than melting point of copper.
Thalaiva..unnayavee orutha yemathittana...😮😮😅
😂😂
ஓரளவு விஷயம் தெரிஞ்ச நீங்களே இவ்வளவு கஷ்டப்பட்டு இருக்கீங்க, எங்க நிலைமை எல்லாம் யோசிச்சு பாருங்க?
S
Assalamualaikkum bro first inverter pcb non inverter lea work panathu aena inverter pcb communication oru signal matu varum.OG ac lea outdoor unit lea contractor irukkum.coil amp 2to 3 amps.
ப்ரோ நீங்க சொன்னீங்க கம்ப்ரஸர் பிரஷர் மூலமாக தான் லீக் செக் பண்றேன் என்று அது ஒரு தப்பான முறை ஏனென்றால் கம்ப்ரஸர் பிரஷர் அட்மாஸ்பியர் ஏற தான் உள்ள செலுத்தும் அந்த அட்மாஸ்பியர் ஏரில் மாய்ஸ்டர் இருந்தால் காப்பர் பைப்புள்குள் நீர் துளிகள் தேங்கிவிடும் பிரபு நீங்கள் கேஸ் ஏத்தும் போது அது அடைப்பு வருவதற்கு வாய்ப்புகள் அதிகம் உள்ளது
Yes thalaiva correct
Before filling gas, use vaccum pump to pumpout compressed air then to remove air in the unit.
அந்த ac க்கு indoor pcb ல compressor line கொடுக்க கூடாது. Out door unit ல contector போட்டு wiring கொடுக்கணும். அந்த pcb ல foult கிடையாது. அது invertor pcb கிடையாது. நார்மல் pcb தான்.
Ithan nanum avaritam sollam irunthen 👍
6700rs loss illa bro ... atha itha video la pota kasa eduthuruvengala bro😅 ...
useful video bro ... don't buy 2nd hand AC
Fact 😂😂
MarQ I bought this Same brand AC
I’m waiting for review
😂😂😂
10:17 adangommala 😂
outdoor unit la contactor use panni pannalam maybe antha technician kku AC work theriyathu , control wire go to outdoor contactor then power supply direct to the contactor
Bro nanu 2nd ac tha use panra but athu nala tha working iruke 2yr achi ipo varaiko nala working iruke 6month once general services panuva....
Enna dhaan technical terms puriyalai naalum annanoda story telling interesting a irukku 😅
Corect bro
I brought second hand Haier AC for 20k new AC Haier price 45k .. it's good working.. and two year warranty ❤ in Vellore
Engah ji vanguningah
Which place in vellore
Vellore ac shop bro
@@ramamirthalingam2529 endha kadaa ketta shop name illaya ? address illaya phone no ilaya ?
@@Music-gt8tc I'll send contact number.. in Vellore you can get it
Coil & compressor Check panni pathu vanganum. 2nd hard AC worth and best.
அடப்பாவிகளா எங்க ஆளுக்கே விபூதி அடிச்சிட்டீங்களேடா 😂😂😂
Bro Voltas 3 star ac new 34000 varuthuu yeathuku marq vanganenga.innu research panne vange erukalam bro.
Hmm voltas nalla irukum nu ellarukum therium bro, marQ epadi irukum thalaivar use panni sollatum.
@@manojmeliodas6961 simplea oru baliadu erukunu sollama soldringa bro.🤣🤣🤣
outdoor la oru single pole conductor poturuntha ready aagirukum rs750
Direct relay output kudutha relay poirum
Relay output conductor coil supply kudukanum
O general A/c best branded A/C
Outdoor door single pole contactor pottu pcb communication wire ah coil contact ku pottutu main phase ah contactor input thanthu output ah compressor kodutha odum
100/கரெக்ட் .கம்ப்னிகடர்ன ஏன் செய்ய வில்லை?
100பேர்சென் கரெக்ட்.
Rendu pipe yaiyum separate ah than thermal insulate pananum ivaru rendaiyum join panni vachi joint ah poduraaru
ஆமால்ல?
Athuku per tan super heat bro
ஸ்லீவ் சுத்த வேண்டிய காரணம் என்ன?
ஸ்லீவ் இல்லாமல் வெரும் காப்பர் பைப் மட்டும் ரன் பண்ணினாள் கூலிங் வராதா?
@@mveera309 செயல்திறன் குறையும்....
Rendaiyum join panni insulate panna thaan efficiency adhigam
Bro i am doing airconditioner pcb service at madurai. Its simple fault only. U must use contacter in outdoor unit. சகோ நீங்க வீடியோல காமிக்கிற பிசிபி வந்து நார்மல் பிசிபி தான் நான் மதுரையில் பிசிபி சர்வீஸ் சென்டர் வச்சிருக்கேன் வீரா எலக்ட்ரானிக்ஸ் நீங்க சொல்ற complaint எனக்கும் நிறைய வரும் இதை சிம்பிளா சரி பண்ணலாம்
Contact number please
Ur contact number
Bro intha video fulla pathen antha tecnical person mela tha ella thappum
Ac leek irukku nu santhegam iruntha atha ac ya fast installation pannirukka koodathu keela vachi vera oru copraser la irunthu pressure vachi check pannanum next antha ac la gas line rendu irukkum atha thani thaniya form pottu apram mela roal suthanum
Ac emty la ran agum pothu over load edukkum atha fuse poguduchi fuse pachi na compressor ah heat agidum atha cool pannittu same fuse ah mathanum athaum olunga seiyala ithalam theriyala oru technician na kopttu irukkinga
Don't use jet spray. It's very harsh and causes minute breakage. I personally had experience
Then how will you clean dust in the coil...The pressure water won't break anything inside the coil it's completely safe don't spread
mis information .
@@memerjod3762 with pouring water. What is misinformation? I personally faced this issue and need to change the inner components after that
Na last yr (new) O General la dhan 1.5 ton Non Inverter AC vangunen. Service la nalla dhan panranga. Relative vetla koda 2015 la irundhu same spec la nalla dhan odudhu (with proper maintenance & service). In my POV, OG is best.
Hi bro can make video about match box. How itsworking.
Naa blue start la 8k ku 2nd ac vangi 5 years use panni erunken, then now scrap ku 3000ku potean. Some time it will save money, luck erutha nalla ac kidaikalam
O general AC PCB board non inverter board outdoor 30 ampere contactor podana bro AC installation panna technician unprofessional
Yes 😂😂😂😂
Don't buy marq AC ... i have to used last 2 years.. some complaints are raised like LED not working, automatically turn on and turn off indoor unit... it's Indore PCB board problem.... after 2 years you have to face these problems 😅 so please mind it
bro indoor and outdoor same model uh athodathu dana pathu vanganum ...til now i have supplied so much 2nd hand ac ... pressure test ellam panni dhan sale panirkom ...podhuva ipdi solla koodathu 2nd hand ac vangadhinga nu..plus 2 free service oda..
எஸ்.தொழிலை கெடுக்க கூடாது. 2,ந் ஹாண்டிவி4,,வருடம் ஓடினாள் o.k.
10:28 Out door la oru 220v contactor coil missing bro oru contactor vangi potrundha matter eppovo solve...aana kennedy annan pavam...(customer ku micham pannanum nu material la micham panna koodathu ) 100 la 90 customers innocent தான்
உங்கள் ac mechanic பயிற்சி இன்னும் தேவை..😂😂😂
😂😂😂
Yess
நண்பரே உங்கள் வீடியோவை பார்த்து முடித்து விட்டேன். ஆனால் இந்த ஏசியில் எந்த ஒரு பழுதும் இல்லை நீங்கள் சொன்னது மாதிரி 3 AIIMS relay normal AC இல் வரும் pcb தான் இது inverter model AC board இல்லை. பொதுவாக எல்லா ac ல் 10 arms relay இருக்கும் ஆனால் o general AC இல் stabilizer இருந்து வரும் output நேரடியாக outdoor க்கு செல்லும் . அங்கிருந்து indoor க்கு 220 v வரும் indoor இருந்து கம்யூனிகேஷன் outdoor க்கு வந்தவுடன் outdoor இல் contactor coil activate ஆகும் பின்பு compressor run ஆக ஆரம்பிக்கும் . Outdoor க்கு indoor இல் இருந்து output director compressor க்கு கொடுக்கும் போது இந்தப் பிழை ஏற்படும் board AIIMS பத்தாமல் short circuit ஏற்படுகிறது தெளிவுபடுத்தி இருக்கிறேன் என்று நம்புகிறேன்
By 'sign Appliance care'
Service Chennai
Bro ..simple outdoor 1no contractor fix painaa problem over bro.. Just 100rs thann... 6000rs save painerukalamm
Yes
Hi . Bro . Actually..that 3 Amps relay contact . Supposed to connect power relay or motor contactor (A1) power only .i mean coil supply. Then 4 sq mm wire to be separately take via motor contactor .
Thanks for this video, broo
I need one help na oru laptop vangalamnu irukae under 60k
Oru nalla laptop suggest pannunga for work purpose only no gaming
But latest future irukuramarii
I'm from Sri Lanka, and I run a small electronics shop. I also purchased a used AC, and the same issue occurred with it. I had to repair it several times and finally had to replace the entire outdoor unit. After a while, problems started again, this time with gas leaks from the indoor unit. So, I decided to purchase a brand new AC, and now it's working fine. The best thing is that I learned a lot from that experience, and now I am reselling AC units in my shop.
நான் Ac என்ஜினியர் தான்
இதுல ஒரு ஆறுதலான விஷயம் என்னவென்றால் உங்களுக்கு வந்த டெக்னீஷியனும், நான் பார்த்த எல்லா டெக்னீஷியனும் ஒரே மாதிரி தான் இருக்காங்க...
நல்லா ஓடும் சார், செமயான மிஷின் நீங்க போங்க நான் இன்ஸ்டால் பண்ணிட்டு கூப்பிடுறேன் சொல்லுவாங்க 😅.. காரனம் இது தான் 👇
இதுல இன்னொரு ஆச்சரியம் என்னவென்றால் இவர்களுக்கு நைட்ரஜன் பிரஷர் test என்னவென்றே இவங்களுக்கு தெரியாது .
ஆன நீங்க ரொம்ப பாவம் பாஸ் உங்களுக்கு ஏர்ல பிரஸர் டெஸ்ட் பண்ணி இருக்கார் 😂😂😂 அப்படி பண்ண கூடாது ஏனென்றால் கம்பிரசர் ஓடும் போது டிஸ்சார்ச் பிரஸர் ரொம்ப அதிகமா இருக்கும்.. அதை நைட்ரஜன் வச்சி பிரஸர் அடிச்சா தான் சரியா கண்டுபிடிக்க முடியும் ஏர் அடிச்ச முடியாது.😅
Compressor ku oru contactor use panni iruntha velai mudinchu irukkum la bro
Reconnect vangi erukalam worth erukum
Reconnect Thane 😂😂😂 ...
Reconnect AC la the E3 error issue mostly varuthu ...PCB change pannalum the problem will come after 4to 5 again .
Now reconnect sale is stop in chennai. But good ac
E3
Check gas.
Check coil sensor
Don't change pcb.
Out door unit la oru contactor podanum and 1st outdoor ku power poganum next Anga irudhu indoor ku power varanum next out put outdoor la iruka contactor coil supply pona contactor moolama main power compressor ku pogum apa unit normal la work agum. Indha video paakum bodhu power and control wiring dhan problem
💯
👌👌👌 எல்லா பைப்பையும் ஒன்னா வெச்சு சுத்தி,.....சூப்பரப்பூ...
na LG 2 ton old ac buy panna 15000 thousandku but athu fitting + gas sethu 10000 thousand aitu 6 month kulla Gas thiruba paitu secondand Ac is too too Worst
Relay load கம்மி பண்ணுறதுக்கு outdoor la ஒரு 220v 2pole condector ஒன்னு ஃபிக்ஸ் பண்ணி modify pannina ok... Relay ku load varadhu.. ella load um conductor ku poyirum
Brass welding rod bro,
Athe mathiri pcb relay oda condition parunga
Mostly OG machine la. Main to Outdoor unit to Indoor unit nu dha wiring varum.
Bcuz contractor base panidha adha machine la work agum bro
Bro antha outdoor la Single Pole Magnetic Contactor Relay varum bro or indoor pcb rotary compressor pcb ah erukum bro. So athanala tha pcb load edukala bro.
AC vanguna link bro
For off site/in home leak check vaccumming is done with vaccum pump till pressure drops to zero, now while waiting for 15 - 20 minutes if the pressure is same(unchanged) no holes in tubes both in odu & idu, if the pressure increases to equalize the outer pressure then there is leak somewhere.
In workshop nitrogen is pressurized (higher than working pressure) into the system and lowered in water tank to see for any bubbles even very tiny holes can be found out and blazed/welded accordingly.
Im not AC mechanic 🧰
Bro yallam therinje nenge yadhekke 2nd handle ac ke poringe
Emi pote podhuse vangunge bro
30,000 புதுசு வாங்கியிருக்கலாம் free service கிடைக்கும்
Vedio kedaikathu 😂😂😂
இந்த வீடியோ ல இருந்தே தெரியுது உங்களுக்கு மின்னணுவியல் பற்றி இன்னும் நிறைய தெரிந்து கொள்ள வேண்டும் என்று...
Fuse failure ஆகி விட்டால் short செய்ய கூடாது. அது main component இல்லை எனவே அதன் current rate ஐ விட அதிகமாக கடத்த காரணமான உறுப்பை கண்டறிந்து பழுது நீக்க வேண்டும்.
Multimeter, oscilloscope, ஐ வைத்து testing பண்ண தெரிந்தால் மட்டும் போதாது... Root cause analysis செய்யவும் தெரிந்திருக்க வேண்டும். அந்த pcb ல் bridge rectifier தான் fault ஆக இருந்திருக்க வேண்டும்.
Bro atha ac vanthu piston compressor outdated and not very energy efficient avaka oru 4000 rs atha vagirpaka.antha brazing panna rod tin and lead combostion may be brass rod kuda use panalam
உழைப்பை பாராட்டிய விதம் அருமை 👉👉👉
Bro outdoor la contacter irukum athu than 10 AmP switch pannum ...😅😅 Oru sila model la
Ji.. apdi illa... relay kkum just a Contact point dha... initial load kkum..... running load kkum vidhyasam irukku.. once ungalukku compressor on aagiduchuna.. ivalavu edukkadhu... gas illadha po... compressor load aagum.. bayangarama... adha ungalukku ipdi vary aagirukku... gas and temperature very very important...
Hi bro ....indoor pcb la oru problem ella .,,ac lam nalla tha erukku bro, outdoor ac unit la oru single phase contact spar and wiring error tha mistake .... So problem ac la ella entha ac anuppuna shop owner and vantha installation person tha Mela tha issu.....gas leak check panna n2 tha use panna nu ....idl prassor potta compressor problam vanthutum and vellding work appadi panna kudathu.....ella work kkum sariya panna ac proper aa work pannum
I am a A/C TECHNICIAN
Sir non-in AC outdoor not PCB only conductor
Naan second laptop vaangaponen advance 10000 kuduthutu vandhen
Nalla Vela apram set aagama naan vangala
Apram konjam naal kalichi new one vaangi 4 years aaguthu ippo kuda SSD 4 years ku Mela aagium boot time kuda 5 seconds aavudhu
Company and model name sollunga nanum vanganum
1. To check the leak of the refrigerant pipes and coil circuits, sop to do fill the nitrogen gas and kept it for 24hr to check the leakage.
2. After confirming that there is no leakage, to exhaust the nitrogen gas by vacuuming the gas through vacuum pump.
3. Then can topup the refrigerant gas into the system.
4. There should be separate thermal insulation for liquid and gas pipes.
This may helpful for future use.
Bro Second AC வாங்குறப்போ apearance ah mattum paathu vaanga ma..Indoor coil and outdoor coil and indoor and outdoor PCB control boar and compressor condition எல்லாம் ஒரு நல்ல technician ah kootitu poii பார்த்து வாங்கினால், குறைந்த பட்சம் 7 years garentied ah எந்த complaint um வராம run aagum.. கம்மி விலையில் கிடைக்குதுனு வாங்கினால் இந்த problems varathan செய்யும்
Same O General AC , aana idhu engaludhu ,12 years nalla irundhuchu, veedu shift pannum podhu idhe madhiri oru local AC mechanic service, welding ,gas( cooling), installation solli 3800+ New pipe 3500 rupees, total 7300 rupees kuduthu ellam fit pannadhuku appuram cooling suthama illa, split Ac close aaga mattengudhu, enga kaasu 7300 rupees waste ,30000 value irundha AC pochu , nalla experience irukkura AC technicians vachu AC service or Installation pannunga
0:53 ஏதோ ஒரு நப்பாசை❤ தலைவர் க்கு
I'm also a Airconditioner dealer in Tirupur. I suggest to buy 2nd AC under 7yrs from manufacturing...don't buy 10yrs AC's
Outdoor unit la oru two pole contactor 15A thangura mari potu vittu irundha indha problem solve pannitu irukkalame thalaivare. Reciprocating compressor lam intha time la kedaikave kedaikaadhu. But power jasthiya sapidim...
2nd hand A/C யாரும் வாங்காதிங்க நிச்சயமாக செலவு வைக்கும்......
Nane review solren mech tna nrm la tna irukum efficiencya la irukathy
There is norms for every fuse depending upon wattage which we used or designed. So removing the fuse connecting with heavy wire may result damaging other parts.
2:19 The two copper pipes, hot line and cold line must be insulated separately to avoid transfer of thermal energy between the two.
@Engneering facts oudoor unit la relay onu vachutu. Pcb output ah oudoor rely ku poitu run aguramathiri. Atha relay ku direct ah phace kuduthurunga. Pcb output relay ku ponathum outdoor start aydum so no more panic
Single OUTDOOR unit, 2 INDOOR unit AC install panlama andha option current ah availble ah iruka?
Bro outdoor ல் realy contactor இருக்கும் முதலில் கரன்ட் outdoor க்கு போகும் பிறகு indoor pcbல் வரும் சிக்னலனாலால் realy contactot ஆப்ரேட் ஆகி outdoor runஆகும்
Bro, Copper la Joint or Filling பண்றதுக்கு Brazing (Using Brass Metal ராடு) பண்ணுவாங்க.
விபரம் தெரிந்த நீங்கள் நன்றாக பரிசோதித்து வாங்கியிருக்கலாம்.நமக்குதான் எல்லாம் தெரியுமே என்ற அலட்சியம் நான் உள்பட..விபரம் தெரியாதவர்கள் installation with warranty யுடன் வாங்குவார்கள்.இது உங்களுடைய அலட்சியம் தான் காரணம்.அல்லது விலையை நன்றாக குறைத்து வாங்கவேண்டும்.அனுபவத்தை பகிர்த்தமைக்கு மிக்க நன்றி.
நீங்கள் correct indoor pcb வாங்கி போட்டிருந்தால் 17100 ருபாய் AC கிடைத்திருக்கும்....
I bought a second hand AC for my mom's room. 1.5 ton for 15k at sapthagiri enterprises, Kodambakkam, chennai. Indoor unit was Blue star, outdoor unit was LG. My mom used it round the clock, it was like seamless and super chill. I hardly serviced it once in an year only. Its been 4 years now it is still working but my mom is no more. 😢
That second hand AC was the best thing ever i bought for my mom.
Super comedy bhaiya but real experience nice bhaiya 😂😂😂
Brother inime ethavathu perusa vangaraku munnadi oru video podunga, nanga irukko research panni solle appurama oru decision eduthu vanguvo deal ok va 🥰🥰🥰
Naa antha video la pathaa outdoor unit laa contractor eilla athaa ungalugu pcb problem vanthu eruku.
Bro inverter ac secound vangathingae.. Board problem.. Buy normal ac before installation check compressor ampear and oil leakage 👍👍
Bro first copper pipe insulation pannathea thappu section pipe and decharge pipe line thani thaniya insulation pannanum next out door la 20 A conductor relay fix panni iruntha ac in door PCB problem vanthu irukathu antha ac fix Panna Anna kum athu theariyathu Pola
ஒருமுறை AC repair நானும் online ல பாத்து service க்கு கூப்பிட்டேன் வந்து check பன்னிட்டு board service பன்னனும்னு 4000 ரூபாய் வாங்கிட்டு ரெடிபன்னியாச்சுன்னு கொண்டு வந்து மாட்டுனான் ஆனாலும் ஓடல அப்புறமா inverter லயும் ப்ராப்ளம் னு சொன்னான் அப்புறம் போயி inverter ready பன்னதும் ஓடிச்சு. ஆனாலும் அவன் boardலயும் problem தான்னு சாதிச்சிட்டான். பழைய பொருட்கள் வாங்கறதிலையும் ரிப்பேர் பன்றதிலையும் எச்சரிக்கையா இருங்க.
Outdoor la oru contactor potruntha ellam ok bro miss pannitinga ponga
Ac outdoor la oru candacter vacha pothum super ah work aagi irukkum bro
😂capturing the Fuse getting blown @ 9:54
Bro ivlo paneenglay ...neenga antha 3amps output vechu 16amp relay va operate panni compressor ku separate line thru that relay koduthu iruklamay!?
Bro you did a huge mistake on buying Marq Ac, they will not bother customer after warranty is over and Jeeves service is very poor. I complaint many times very very irresponsible answer from call centre as well as Jeeves
Athu copper thaan bro. But, athu oxidation Nala karuppa theriyuthu
Thala, andha 6700 aava indha video la eduthuduwa ila 😂😂😂
Normal ac PCB kuda inverternu tha bro online la kattum
Very useful ful video ... Nala vela etho nala mechanic ah irukavo vela pathan .. Ilana avalavuthan.😂😂😂
Engeeneering facts'key indha nilamaiya....
Nenga vanguna ac very old AC.. outdoor unitla contactor varum adha pottu irundha fuse pogi irukathu. Boardum prblm agi irukathu
Bro intha mathiri ac kku 240vac magnetic contactor vakka sollunga. Prechanna solve aayidum ,athukkaprm pcb kku periya precha varathu
Best AC is non-inverter AC brands of Japan, Panasonic or Daikin.
Mitsubishi heavy industries and Electric