Reinforcement Rebar Footing, Column & Beam in Revit 2021

Поділитися
Вставка
  • Опубліковано 21 сер 2024

КОМЕНТАРІ • 19

  • @lychov7485
    @lychov7485 4 роки тому +5

    We need that kind of Tutorial

  • @rocky8004
    @rocky8004 11 місяців тому

    Awesome teaching Sir

  • @benzonjhermogeno
    @benzonjhermogeno 11 місяців тому

    Revit should release an update on automatic propagation and avoiding segmental spacing of ties also the manual sketch of long bar at bottom. This vid is cumbersome method so far

  • @SchwanaCARDHUT
    @SchwanaCARDHUT 2 роки тому +1

    Bravo

  • @namulondosarah6191
    @namulondosarah6191 2 роки тому

    this is nice.. thank you

  • @alisajjad1661
    @alisajjad1661 3 роки тому

    Please make a video tutorial How to import workset to one project to another project

  • @fuadhasan3625
    @fuadhasan3625 2 роки тому +1

    You made videos without mouse cursor. How shall I know what are you doing there?

  • @vgmogbi6447
    @vgmogbi6447 3 роки тому

    Thank you. Keep it up

  • @surenharutyunyan1824
    @surenharutyunyan1824 3 роки тому

    U should've placed vertical rebars in columns first and then the stirrups.

  • @lifeline7673
    @lifeline7673 Рік тому

    what was the problem behind half hidden stirrup? It occur at 22:53 at your video. I am facing the same problem in column stirrup. Please help.

  • @Mickywongtong198
    @Mickywongtong198 3 роки тому +1

    Hi, instead of copying and pasting the rebar why dont you use max spacing. It makes its so much easier when designating bar marks and schecule.

    • @RevitGlobalKnowledge
      @RevitGlobalKnowledge  3 роки тому +13

      Hi, @micky wong. Thank you for your question.
      Answer: if you're using max spacing every stirrup will be the same spacing. in reality, construction, if your column or beam from bottom to top same spacing your column or beam will be crack.
      The requirement from ACI code: Purpose of providing Closer Stirrups Spacing at both Top & Bottom end in RCC Column. The spacing of ties is calculated as per the plastic moment capacity of the column. The spacing you come up is required at the ends because the moments at the ends are greater and you have most of the cracking going on in the end zones.
      that's why I need to copy instead of using max spacing. if you study civil engineer, you'll understand more about that. thank & have a nice day

    • @benzonjhermogeno
      @benzonjhermogeno 11 місяців тому

      That is called zoning

  • @abhayvarma3065
    @abhayvarma3065 6 місяців тому

    How to convert to pdf this design please tell

  • @I_kiza_real
    @I_kiza_real 2 роки тому

    Is it can hide a concrete, it only see rebar only, is it can do sir?

    • @RevitGlobalKnowledge
      @RevitGlobalKnowledge  2 роки тому

      Yes can hide in concrete, however you might need to adjust at Visibility Graphics and turn off solid rebar.

  • @fuadhasan3625
    @fuadhasan3625 Рік тому

    Can you please share this project file?