HOW TO MAKE THE ULTIMATE EXTENSION CORD!

Поділитися
Вставка
  • Опубліковано 8 січ 2025

КОМЕНТАРІ • 1,9 тис.

  • @LarryCoates1948
    @LarryCoates1948 2 роки тому +1656

    My one suggestion as an electrical engineer would be to place 20 amp outlet at the end where the line cord enters the first box and put the indicator lamp and hospital outlet at the far end. That would serve two purpose... it would keep the heavier current from passing through extra wiring and connections. Second having the indicator at the far end would indicate that power is actually getting to the farthest end of the unit!

    • @fourtwanky
      @fourtwanky 2 роки тому +40

      except they used those wago bus bars to distribute the electrons, so each outlet was effectively the same distance from the main wire.

    • @amkelle2
      @amkelle2 2 роки тому +47

      Can you explain the purpose of a 20A outlet when that GFCI plug is only rated for 15A?

    • @LarryCoates1948
      @LarryCoates1948 2 роки тому +37

      @@amkelle2 - As stated in the video the 15A gfci can handle some overload although that is not ideal. You could usd a 20 Amp, inline gfci unit instead, but that might require you have access to a 20 Amp receptacle as the source power.

    • @amkelle2
      @amkelle2 2 роки тому +13

      @@LarryCoates1948 To be fair, yes, I did not intently watch the whole video, I skipped through a lot of it to get the jist. But still, wouldn’t a 20A pull on a 15A outlet be unsafe? Or even pointless if the breaker is 15A

    • @LarryCoates1948
      @LarryCoates1948 2 роки тому +8

      @@amkelle2 - it could be a problem but most likely not for a short term use. Long term yes ti would be a problem but would trip the breaker if it heated up for too long!

  • @DobermansRock
    @DobermansRock 2 роки тому +224

    This was hands down one of the best instructional videos I have ever seen dealing with electricity. Knocked it right out of the park.
    It is also cool you are a father son team. Lots of guys wish they had that growing up.

    • @terrydouglas2777
      @terrydouglas2777 2 роки тому +11

      Plus you are still using your dad's electrical cords and they will be passed down to your son then his son in the future. The best part you are father and son, passing knowledge is what I truly love to do an teach my family how to fix and build things. I said family because I have an still teach my boys and girls how to do stuff. Teaching them is fun for me and they teach me new things as well. Making memories is what life is about isn't it. An you making videos of you both together is awesome. Better than the old time photo album our parents loved to bring out several times a year to look at.

  • @JeremySpidle
    @JeremySpidle 2 роки тому +216

    Pro Tip: When tightening a cord into into a strain relief, press the cord inwards towards the connections on the device to de-strain them while you're tightening it down. This provides some slack inside the device and prevents strain-loading the connections during assembly.
    And... great video, thanks!

    • @lostreb
      @lostreb 2 роки тому +14

      Great Comment!!! (While Stud Pack may have done that by instinct and because of experience, and didn't mention it. That's great information for those of us that don't have that experience to fall back on!!! Thank you.)

    • @jokinboken
      @jokinboken 2 роки тому +8

      That sounds like something learned from experience! An "Ask me how I know" bit of knowledge. Thanks!

    • @parkershaw8529
      @parkershaw8529 2 роки тому +31

      Also, cut the hot wire a little shorter than the other two wires, so, if the strain relief does fail, hot wire is the first to get disconnected.

    • @swordedaffair
      @swordedaffair Рік тому +1

      The ground wire should be longer than the other two. If stress on the cable causes wires to pull out or break, the hot or neutral will fail first - not the ground.

  • @mikezimmermann89
    @mikezimmermann89 2 роки тому +126

    EXCELLENT VIDEO! My dad was an electrician for 47 years and he taught me to be conservative and cautious in order to keep things safe. It was GREAT to see you carefully use many of the tricks that he taught me as well as many of the tips I’ve developed over the years thanks to his careful training. Cable stripping, strain relief, proper use of tools and adapters… you hit them all.
    Hats off as well to your commenters, who taught me all sorts of useful and interesting things that even 30+ years of well-informed DIY work had left me wondering about.
    I’ve subscribed to your channel, and I’m planning a “binge watch” to prep for some upcoming projects!

  • @Riless42
    @Riless42 2 роки тому +475

    Most new breakers have 2 trip methods. One is magnetic which works primarily during a fault. The second is a bimetal coil, similar to an old fashion thermostat, this is the one that handles general overloads. Depending on the manufacturer, age, and use of the breaker it can take time for the coil to heat up and trip. Certain manufacturer like Zinsco and Federal Pacific wont trip and you get the smokey house effect. We hope there isn’t one in the house you’re at. It is perfectly normal to hit a higher amperage on a breaker for a short period of time before the coil snaps. I have seen a 20 amp breaker hit 25 amps and hold for 10 minutes. Ultimately heat is what trips the breaker in an overload and it takes time for the heat to build up and trip the breaker. If you had a thermometer on you at the time of the video, you most likely could have identified the breaker you were using by the amount of heat it would have been producing. How ever I don’t suggest replicating the scenario to try it. Overloading a circuit is never a good thing. The more heat a breaker takes on the easer it trips the next time.
    Great video! I got out of remodeling to became an electrician. I mis the remodel world. I watch your videos and you guys always have some new concept or product that I have never seen. There are a lot of new products that has come out in the last several years. I really liked the cabinet leveling kit. I switched to air bags just before I got out of the business, but this little gizmos you guys used knocked the socks off the airbags. I can’t wait to see the next video.

    • @TopCat2021
      @TopCat2021 2 роки тому +22

      Excellent response to the question about the trip time, also the trip time is delayed for the inrush current of high inductive loads.

    • @moreause
      @moreause 2 роки тому +6

      @@TopCat2021 I have seen 90 amp on a 15 amp breaker for a second or so to close a F***ing big coil
      was just a testing rig , normally this was powered by a dc charger and battery
      but was still surpise it was holding

    • @themadmallard
      @themadmallard 2 роки тому +5

      I was about to say, arent breakers, supressors, etc all supposed to be sacrificial components? I'd definitely consider replacement in multiple scenarios...

    • @t0cableguy
      @t0cableguy 2 роки тому +11

      Your answer is spot on.
      There are also trip curves available for almost every breaker except for those horrid Zinsco and Federal Pacific panels. Its pretty interesting to see how long a breaker will hold with a particular breaker. There are also different breaker trip curves, A-F that will determine the In-Rush available. In-Rush is what allows motors and capacitors to charge without tripping breakers constantly.

    • @tslim250
      @tslim250 2 роки тому +5

      Zinsco and federal pacific are pretty much known in the inspection world as a no go and always labelled as a must replace. Interesting to see a sparky call it out in the wild.

  • @brandonleesanders
    @brandonleesanders 2 роки тому +13

    Love how this guy took the “know-it-all” suggestions and added ALL of them to the project. GENIUS!

  • @ianworden5196
    @ianworden5196 2 роки тому +228

    The super extension cord video was the first video of Stud Pack that I watched. Since then, I have watched every video of yours. I’m hooked. Great content, loads of fun and Paul’s personality has really come thru since your first video. Love the father son interaction and that Jordan is so respectful. I have a few tools of my fathers and grandfathers and really cherish them like you do with your fathers extension cord. Got to give Jordan a shot out. I assume this was his idea and the filming has been terrific. I’m not in the trades so Paul’s ability to clearly explain the work and tricks of the trade is excellent. He has a real gift.
    Having grown up in northern Florida, the heat and humidity is gruesome. So I know the conditions you are working in. The only video that was hard for me to watch was when you were installing pipe under the patio for a toilet. Paul looked whipped by the heat but he prevailed. I looked and felt the same way when working road construction in the summer in Fla. Thanks for such a fun and interesting channel. Keep it going.

    • @jperin001
      @jperin001 2 роки тому +5

      Same here!

    • @bobjones9727
      @bobjones9727 2 роки тому +8

      The first video I watched was the first extension cord build. I have watched every video since. All very well done and edited. I consider myself a jack of all trades and a master of none and have learned many things watching this channel.

    • @austincummins7712
      @austincummins7712 2 роки тому +6

      Yep, same here. Glad I found your channel!

    • @carltonfaller3986
      @carltonfaller3986 2 роки тому +7

      Me too!! I made something similar to the first ext cord project years ago and watched to see if maybe I could improve it. Then I got hooked on the whole Stud Pack attitude. And I was like, "that guy sounds like people I know." I live in Texas now but I've got family all over SE LA including BR.
      You guys are awesome and I really appreciate it that you keep a positive happy attitude. Keep up the good work. God bless.

    • @cdag24
      @cdag24 2 роки тому +2

      Same!

  • @XboxSpecialist
    @XboxSpecialist 10 місяців тому +4

    I only ever made one electrical item my entire life - but , I still think it's worth sharing with others . Basically , I just used a 100' manual reel and fit 200' on it . Works great just be careful to not twist the cord too much or too little and I let the two ends meet outside of the reel so there's more reel space and easy access without needing to unroll to run a split or whatnot . Thanks for the video . Y'all are awesome .

  • @T_Jonesy
    @T_Jonesy 2 роки тому +288

    This thing is incredible! Also love that when viewers suggest improvements, you guys listen instead of getting offended. Leads to an amazing solution like this. Great video as always. Love your channel.

    • @DiffEQ
      @DiffEQ 2 роки тому +3

      Replete with expensive and completely unnecessary things. See my full comment for details. $15 for an indicator light? 12AWG stranded wire for a ground when even the current carrying conductors only need to be 14AWG solid?
      This channel was much better when it was just a son helping and documenting his dad doing remodeling work. It's now to contrived and monetized. I have nothing against people making money for their hard work... but I do have a problem with contrived content and "shocking" thumbnails used to manipulate. It ruined the channel for me. Do you think everything they linked to the overpriced McMaster site isn't getting them something at OUR expense? Please.

    • @sabar-q9p
      @sabar-q9p 2 роки тому +54

      @@DiffEQ They didn't link anything to McMaster-Carr, they are just part numbers to look up yourself. That uncharitable comment of yours says everything about your heart's intentions. Try to be more kind.

    • @nicholasburr4825
      @nicholasburr4825 2 роки тому

      @@DiffEQ just because your name is Richard, doesn’t mean you have to be a Dick.

    • @StudPack
      @StudPack  2 роки тому +96

      @Richard M Interesting you mention the price Richard. We had thousands and thousands of people pick apart a simple extension cord and tell us how we should've done it. But when we spend the $300 to build it how they want, it's "too expensive". It's still a son helping and documenting and of course it's contrived, like everything we do! Thumbnails are used to get people interested, and none of our thumbnails lie or mislead. If you have a problem with attention grabbing Thumbnails, maybe UA-cam isn't for you bud. We put part numbers up for McMaster and we receive no kickback and we rarely post Amazon links even though we get hundreds of people telling us we need to do so. We don't like to respond to comments bred from negativity, but everything you said is blatantly wrong, and you should know that.
      - Jordan 😎

    • @TheDarthJesus
      @TheDarthJesus 2 роки тому +5

      @@StudPack To be fair, quite a significant amount of your electrical "guides/suggestions" don't follow electrical code, and are unsafe/hacks that professionals are constantly having to fix. This went from a cool father/son channel to something cringe-worthy when your explanations/excuses for doing things illegally/wrong become video topics.
      Stick to what you're good at?

  • @TwilightxKnight13
    @TwilightxKnight13 2 роки тому +256

    Pro Tip: When you are twisting stranded wire, twist in the opposite direction. You may notice that when you cinch the ground screw it tends to splay the wire. The reverse twist is in the same direction as the cinching of the screw so it actually squeezes the wire in the same direction as the twist making a "better" connection.

    • @ottoroth9377
      @ottoroth9377 2 роки тому +17

      Ya know Bob....I would even go further and solider the twists..no freedom wire exposed....easier to insert.
      Stud man....gotta love that old wire...they made em well 40 to 50 years ago. Also, congrats no blood!

    • @codewonderland-gaming
      @codewonderland-gaming 2 роки тому +16

      I would go even further here honestly. Over time, a soldered stranded wire end will warp due to heat and pressure when places in a screw terminal. Instead, crimp and solder the wire end in a ring terminal and put the screw through that

    • @codewonderland-gaming
      @codewonderland-gaming 2 роки тому +5

      Without that extra step, the "contact resistance" will continue to increase over time and can cause a fire

    • @willschultz5452
      @willschultz5452 2 роки тому

      I'll give it a try!🙂

    • @randybobandy9828
      @randybobandy9828 2 роки тому +10

      @@codewonderland-gaming Just crimp it, no solder

  • @ncooty
    @ncooty 2 роки тому +28

    This video and the comments below reflect one of the things I like most about this channel. Paul is 85%+ for an amazing number of trades, and he presents in a way that is accessible to DIYers without condescending to pros. That means he attracts a very wide range of people, AND he's humble enough to showcase suggestions or corrections. I could hardly be more impressed with Paul.
    And obviously, thanks to Jordan for making the channel possible and for making the connections/ asking the questions for those of us who aren't as widely competent as Paul is. :) You two are a great team that has built a forum for a very helpful community.
    *Thank you.*

    • @DiffEQ
      @DiffEQ 2 роки тому +2

      I used to be impressed. That's why I started watching years ago. Now, it just more contrived and scripted nonsense and it's lost that organic feel of a son helping his talented father. Just take a look at the thumbnail progression... more of the "shocking" and "???" thumbnails that are only used to manipulate and please the algorithms. They lost my subscription!

    • @steve_main
      @steve_main 2 роки тому +7

      @@DiffEQ Then move on.. sorry I have seen a few of your comments on here on other peoples comments. If you don't enjoy the channel anymore than don't make those that like it have to listen to your negative narrative.. just unsubscribe and move on, Paul and his son don't owe you anything

    • @DiffEQ
      @DiffEQ 2 роки тому +3

      @@steve_main What's your point? I already said I have moved on; As have many others. Doesn't mean I can't make the reasons known. Do you live in that world where all comments have to be praise and support? Do you? And you are wrong about people who are soliciting subscribers for profit when you say they don't owe those subscribers anything. This is not an altruist venture, sir. Get a grip. You chose to respond with negativity but others are forbidden to do so without your concurrence? SMH

    • @____________________________.x
      @____________________________.x 11 місяців тому +1

      People who show their mistakes on camera are good people. It’s how everyone learns faster

  • @SuperTubeLurker
    @SuperTubeLurker 2 роки тому +133

    Been doing industrial maintenance like ~6-7 years now and grew up in a home where we did everything DIY. Had literally zero knowledge that there was a stranded and solid side to strippers. Learn something new every single day, as long as you allow yourself to admit when you don't know.

    • @SlapperGlutesTwice
      @SlapperGlutesTwice Рік тому +2

      Idk if I would advertise not being aware of super basic details like that. It says more about you as a worker in your trade than it does about the quality of this video 😂😂

    • @SuperTubeLurker
      @SuperTubeLurker Рік тому +17

      @@SlapperGlutesTwice I'm not going to pretend. If you can't admit you don't know something you don't keep yourself open to learning. In any trade, if you keep your eyes and ears open, you learn something new every single day.

    • @nickiecass8808
      @nickiecass8808 Рік тому +3

      Me too, I just learned it today! I love these videos Thanks !

    • @HA05GER
      @HA05GER Рік тому +4

      Depends on the strippers you use. I prefer the self adjusting jaw strippers or.just do it by feel. Most electricians I've ever come across strip by feel.

    • @BluesTravels487
      @BluesTravels487 Рік тому +1

      I work in industrial electronics at a wire manufacturer, just to inform, the copper size is likely smaller than actual gauge size regardless of solid/strand. do you think they are just giving copper away?

  • @aerotraveler
    @aerotraveler 2 роки тому +11

    Ha ha…you are giving code enforcement and fire marshals across the world heartburn for sure with this project. Love it.
    I guessed right on the USB outlets, but you left out my second device. I was expecting a load sensing circuit to power up your shop vac whenever you started your saw. Maybe video three.
    Final comment is solid wire inside would be fine. Nothing should be moving inside these boxes. The stranded wire just made it harder to wire up like on that ground screw.
    Thanks for the entertainment.

    • @dubmob151
      @dubmob151 2 роки тому +3

      I'd add a power monitor to the rig that can display the voltage, current, and power factor. They're available for a very low price and will let you see at a glance if you're approaching the limits. Basically a small panel display with a current sensor that you run the feed wire through. It'll add a Kill-A-Watt function to make it more ultimate. 😉

  • @grizmt7779
    @grizmt7779 7 місяців тому +2

    I’ve been a DIYer all my 74 years and I learn something new from each video on your channel. Thanks, Keep up the good work.

  • @Terkinstein
    @Terkinstein Рік тому +7

    I used to drive a truck delivering stud packs to job sites. I really love y'all's channel. My late stepdad who I loved very much was a General contractor like you. He taught me so many cool things that I still think about today. When I watch you and hear your voice explaining stuff, maybe it's the kind tone you have, it just makes me feel like my stepdad is watching with me.

  • @chrisspellman5952
    @chrisspellman5952 2 роки тому +8

    When I was a kid, I remember my Dad and Grandpa trying to teach me stuff like this all the time. But I was to young to understand and appreciate it. Just ranomdly today UA-cam decided to share your videos with me and it's been great.

    • @Kristinapedia
      @Kristinapedia 2 роки тому +1

      All that stuff is filed away in your brain somewhere. Watching these videos will bring it back.

  • @terryford4821
    @terryford4821 2 роки тому +17

    These Stud Pack how-to videos are quite possibly the BEST of their kind on You Tube.!!! They are at once instructional, understandable, complete and detailed without being pedantic or arcane, humorous and fun to watch, and the camera work is outstanding!!!!!! Count me as a Number One FAN!!!👍👍👌👌😁
    😄

  • @hstruzyt
    @hstruzyt 2 роки тому +10

    I would mount the last grey outlet turned 180 degrees. You see at 23:30 how a right angle plug blocks the second outlet. Reverse the outlet, and you can use a right angle plug in the lower, or outer spot, and leave the other outlet available if needed.
    Great video!

  • @knutsenp1
    @knutsenp1 2 роки тому +6

    Darn you, I just made your SUPER extension cord now you show me an ULTIMATE extension cord. I can't keep up with your great ideas. I'm retired and no longer take on the scale of projects you so easily tackle, so I guess I'll live with my SUPER extension cord. It was a fun project. You both produce great videos that are so great to watch. Keep up the great work. Stay safe.

  • @rfitzgerald2004
    @rfitzgerald2004 2 роки тому +66

    The vacuum part surprised me, I hadn't really thought about it before but I assumed when it was clogged that it would be pulling harder to overcome the clog therefor drawing more current, turns out I was wrong. Every day I learn something new!

    • @davidk8893
      @davidk8893 2 роки тому +26

      Yep, the vacuum draws less power due to the partial vacuum it creates behind the impeller. The motor has less drag since there's no more air to move and it starts spinning faster (hence the louder noise). One thing to keep in mind though is that since the vacuum is not moving any air through the filter it's also not moving any air through the motor. This means that the motor won't get cooled anymore and it may overheat.

    • @peterfus926
      @peterfus926 2 роки тому +1

      Same going to change my way how i look at that not to much stress then

    • @igotsomespace
      @igotsomespace 2 роки тому

      Exactly my thinking and logic too prior to this video

    • @johnburgess2084
      @johnburgess2084 2 роки тому +5

      The blades in a fan are like airplane wings -- when you have a proper angle of attack, the wing produces lift to support the plane's weight, which also produces drag (load). As a plane slows, the angle of attack between the wing and the air increases until the air no longer flows smoothly over the wing; when that happens (a "stall"), both lift and drag are decreased. So, like the airplane wing, the blower blades stall, not moving air, and not loading the motor as much because, as others have said, little energy is being used to do work. That floored me for the longest time, too, until I became a pilot and thought of the lift / drag in that context.

    • @thomasjameson5761
      @thomasjameson5761 2 роки тому

      I also thought this!

  • @JRiffle_HeaveHoStudio
    @JRiffle_HeaveHoStudio 2 роки тому +37

    In Ham Radio we often add meters to our panels to monitor voltage and amps on our rigs. This is especially helpful on mobile setups where you might be operating from a battery. Having a small LED display about the size if your green light would be handy to make sure you don't overload the circuit.

    • @Satsujiki
      @Satsujiki 2 роки тому +1

      This is great!

    • @henderson1914
      @henderson1914 2 роки тому +4

      Any ideas where to source or find one of the led displays?

    • @josephlieberman3027
      @josephlieberman3027 Рік тому +3

      "Jameco" Electronics company

    • @waxingmoonjfs
      @waxingmoonjfs Рік тому

      ​@@henderson1914 I picked up a 5 pack of mini DC volt meters off Amazon for less than $10, I have seen the AC versions for about the same price.

    • @jimthesoundman8641
      @jimthesoundman8641 Рік тому

      @@henderson1914 I get mine from Temu, AliExpress, Banggood or Ebay, whichever is cheapest. Make sure you verify their readings, sometimes the cheap ones will be inaccurate by 10% or so, but as long as you know, you can compensate. They have voltage ones, and ones which will display voltage and current both. Even ones which will display voltage, current and frequency if you are running off a generator.

  • @uhitskyle
    @uhitskyle 2 роки тому +2

    For some reason this video speaks to me. My Father is like a God from what everyone says when it comes to home improvement and I've been around it my whole life so when you mentioned your son records you it touched me man. I love it

  • @pitsnipe5559
    @pitsnipe5559 2 роки тому +15

    That has got to be the most awesome extension cord of all time. Reminds me of the ones we built when I was in trade school in sixties. We had the auto shop weld up some stands. We then attached two eight inch square boxes and wired in two duplex receptacles in each with thirty feet of 12/3 stranded cable. Great job site cords but know where near yours. Of course it was 1966.

  • @buddhabbuddhism8420
    @buddhabbuddhism8420 Рік тому +1

    My dad passed away in March, of this year. He had the same type of extension cords you have, heavy duty black, and even one with the double outlet on the end (no GCFI tho). Seeing this, I'm now going to re-purpose his cords, for the ultimate extension cord, and memory. Made my day sirs. Ty. -George

  • @EMTevjorgensen
    @EMTevjorgensen 2 роки тому +24

    Jordan, I've got to say great camera work. You do a fantastic job filing your Dad as he's doing the work. I think you could pitch a show to the Home Channel on TV, you guys are way better than some of the other Home Improvement DIYers channels out there.

    • @tarbell111
      @tarbell111 2 роки тому

      I second that. You have good attitude. Chipper. Ppl love to watch your videos. I would watch u on satellite for sure.

    • @Sembazuru
      @Sembazuru 2 роки тому +2

      Probably comes from long experience of holding a flashlight. Similar activity: Point and keep steady on the work, predict what the next activity is so you can point to where the attention should be. I must say that I got plenty of that training as a wee young kid, myself.

  • @pjh1776
    @pjh1776 2 роки тому +7

    Watching your videos reminds me of working with my dad, God rest his soul. Bud, cherish these days of working with the old man. You will never forget the life lessons weaved throughout his common sense work ethics and skills. Love your Stud Pack videos, thanks. Oh, and I have some old heavy duty cords from my Dad, I know what I'm doing with em this weekend.

  • @kilopo3030
    @kilopo3030 2 роки тому +8

    Hey man thank you.
    I binge watched this channel the past 2 weeks on my free time. I love this. My dad past away oh cancer 6 years ago.
    He was a handy man and showed me these tricks. But I’m learning so much more.

    • @PumpkinDog33
      @PumpkinDog33 2 роки тому +3

      Sorry for your loss. Paul is a great father figure and his interaction with his son shows a really good dynamic where he's passing on wisdom without being arrogant or elitist. Especially when his son (or the internet) has ideas different from what years of experience has taught him.

    • @104silvae
      @104silvae 2 роки тому +2

      Im sure your dad is proud of you. God bless you.

  • @RichardBronosky
    @RichardBronosky 2 роки тому +43

    25:55 My Dad was a Navy man in Vietnam. He learned this fact there and explained to me no less than 100 times. Which in hind sight was good because it took me about 20 to really grasp. When the impeller is able to move fluid linearly in flow, it constantly encounters new, axially stationary, fluid and then has to introduce torque. When the flow stops, the impeller puts torque onto the fluid, which remains linearly stationary, and the system becomes a flywheel. And we all know a flywheel take a lot of energy to get up to speed, but very little to keep at speed. I was probably 4 years old the first time I heard this and 8 before I could finish his story for him.
    Thanks for the memories, Stud Pack. ☮❤🌈🧘🏽🕉☸☯

    • @____________________________.x
      @____________________________.x 11 місяців тому +1

      Good explanation 👍

    • @dubmob151
      @dubmob151 8 місяців тому

      A blower with squirrel cage fan also increases in speed when it's blocked on the airflow.
      The load test with the saws would have seen a very large increase in current draw of they were actually cutting wood rather than just free spinning; it's not very representative of their power draw just by turning them on.

    • @JeffcoInc
      @JeffcoInc 7 місяців тому +1

      My dad, also a Navy Man in Vietnam, went on to civic life as an electrical engineer, though his tradecraft was as Master Electrician. Mom was a public school teacher. A proud union family we were!
      When I was a kid I was "asked" to crawl around under houses (spiders, snakes, rats, even bats!) and in attics (either bitter cold or abominably hot...plus vermin and insects of every kind. Wasp bites were especially fun while rolling around in fiberglass in July heat.) But he made working hard fun. I got to swear like an actual sailor, trade barbs, take a ribbing and had lots of laughs.
      So cool to see Stud Pack guys as father/son team. That is rare!
      Like your pops, I paid a passive ear to his 'splainin as a kid. And though he's passed now, I can still recall hundreds of rhyming schemes, anecdotes and shorthand! I literally apply those mnemonic devices in physics, math, chemistry and weekend handyman projects now,
      As an adult who's also an engineer (of a different flavor), I'll always fall back on Dad's sage advice in tricky situations.
      @StudPack you guys do fantastic work! Love the channel!

  • @piercethesky281
    @piercethesky281 2 роки тому +258

    Breaker didn't trip instantly because its being overloaded and not short-circuited. It'll take a few seconds to a minute to trip at only 8 amps of overload current and that's normal. Higher current overloads will trip it faster.

    • @JeremyPeters
      @JeremyPeters 2 роки тому +44

      Just something to add to explain it a little better, there’s a strip of metal or a spring inside the breaker. 8A of overload will heat that metal up, making it softer. Over time that metal will deflect or bend, thereby causing the breaker to trip.

    • @northernlightsrenovations1710
      @northernlightsrenovations1710 2 роки тому +21

      @@JeremyPeters Jeremy is correct. The breaker is thermally activated so if you allowed the 28 amps to continue for a period of time (rather than just a few seconds) it would indeed trip.

    • @Hachiro
      @Hachiro 2 роки тому +36

      @@JeremyPeters Just like how turn signals used to work in cars, before they went electronic.
      The current from the incandescent turn signal bulbs would heat up the bi-metallic strip inside of the signal relay, making it deflect, cool down, and reconnect itself automatically for each flash.
      It's what causes the clicking sound you hear when you use your blinkers.
      Though, modern cars use LEDs, and electronic flashers. So the clicking sound you hear now-a-days is faked.

    • @trekie30122
      @trekie30122 2 роки тому +5

      @@northernlightsrenovations1710 Most breakers trip and are able to be reset. Does the metal return to the original shape allowing it to be reset? Does a short just heat the metal to a deformation instantly then? last question, another UA-cam channel explained how an automatic analog rice cooker works using thermal deformation and a magnet like the old dial thermostats, does a breaker work the same way?
      Thanks for the response and explanation.

    • @notusedexer
      @notusedexer 2 роки тому +2

      @@trekie30122 good questions. I hope someone answers.

  • @ronlovell5374
    @ronlovell5374 2 роки тому +38

    Love this! I was gonna buy an expensive power strip bar with led lights and USB built-in for my shop, but now I'm inspired to build a custom one and add an auxiliary twist-lock whip and breaker for my generator. Thanks Stud Pack!

    • @desireeespinosa3954
      @desireeespinosa3954 2 роки тому +2

      I just added some heavy duty in wall outlets with USB and C ports in my shop. Made a huge difference.
      So much better 😂

  • @Tritium21
    @Tritium21 2 роки тому +103

    If you look in the datasheets for most circuit breakers, they have the over-current to hold time graph, which is a curve. at a low amount over the rated current it will take quite a while (up to an hour) for the breaker to trip - 15.5 amps in a 15 amp circuit for example. As the draw goes up, the hold time drops. A 60 amp draw would almost instantaneously trip a 15 amp breaker. Mechanically why this happens has been covered in many comments. Why this is a good thing... hasn't. Breakers can be designed to trip instantaneously for any peak over the rated current, but this provides no extra protection, and very well might cause problems with high draw devices like motors, that can draw great amounts of current at startup, but level off very quickly (inrush current). A few seconds above the rated current isn't going to heat the wires in the walls significantly, and since the breaker is only there to protect those wires (....and nothing else), there's no value in making it trip any faster.

    • @sivadfa
      @sivadfa 2 роки тому +4

      Yeah, being able to hold a surge current for even a short amount of time is important. We don't want a circuit to break every time an Air Conditioner brings its outdoor unit online as an example.

    • @hsnester
      @hsnester 2 роки тому +4

      electroBOOM on youtube had a video where he put 100 amps through a 20 amp breaker and nothing. he got the data sheet and it said something like it can take anywhere from 60 secs to 5 seconds to trip based on the amps running though it.

    • @sivadfa
      @sivadfa 2 роки тому +2

      @@Styrofo4m GCDIs are made to protect humans. Breakers and fuses are made to protect equipment and prevent structural fires. The main specification for a fuse or breaker is that the circuit breaks before the cable causes a fire, or hopefully break something.

    • @sivadfa
      @sivadfa 2 роки тому

      In most countries gcdis and breakers tend to be one and the same. In USA this is not the case often only having ground fault protection to select few rooms.

    • @sivadfa
      @sivadfa 2 роки тому

      @@Styrofo4m two different names around the same thing. It depends on which country you live in which is standard

  • @raphaelnemetsky
    @raphaelnemetsky 2 роки тому +29

    I see one improvement I would make. I would have the cord wrap BELOW the outlet boxes. That way I could use the boxes with unwrapping just a few feet of wire. The way it is now, you have the wire blocking the boxes. BTW, this is my first time watching your videos and I liked / subscribed.

    • @jamesalles139
      @jamesalles139 2 роки тому +4

      for a variety of reasons, it is better to not have current carrying conductors coiled up. (heat build-up, magnetic coupling & noise)

    • @TwilightxKnight13
      @TwilightxKnight13 2 роки тому +2

      @@jamesalles139 While certainly true, it is not really a factor in this application because the things being plugged in are generally motor-driven devices which already create a lot of line "noise," fluctuating magnetic fields, etc. If your application is so sensitive to these minor data points, you would engineer it to a much tighter standard. They already "over" engineered using the hospital-grade receptacle.

    • @jamesalles139
      @jamesalles139 2 роки тому +3

      @@TwilightxKnight13 un-wrapping the cord is not 'over-engineering', it is simply a good habit for high-current loads.

  • @DrewnTiny
    @DrewnTiny 2 роки тому

    Well, I'm not an electrician and I don't even play one on TV so I thought it was an awesome build and I applaud you guys for teaching a newbie like me how to be safer. All of the commenters that are telling you that you're doing it wrong can pound sand for all I care!

  • @johnroumeliotis5917
    @johnroumeliotis5917 2 роки тому +47

    Hi Stud Pack , I am a electrician in Quebec Canada , I love your videos keep it up. The reason it didn't trip right away, is it wasn't a short circuit , try it again but wait longer so the breaker heats up and goes on overload , it should trip . But there are lots of old panels like commander and FPE panels that are notorious for not tripping on overload conditions. Electrical panels do need to be tested after 20-25 years .

    • @cheeseburgerbeefcake
      @cheeseburgerbeefcake 2 роки тому +1

      As a bit of trivia for you - the current recommendation in the UK at the moment is every 10yrs, but we do have the madness of ring final circuits!

    • @mattholladay1331
      @mattholladay1331 2 роки тому

      i agree with this statement

    • @VictorLopez-vc6cf
      @VictorLopez-vc6cf 10 місяців тому

      Nice was also going to say this I am a Sparky in Texas

  • @ricklarson9524
    @ricklarson9524 Рік тому +1

    I do a lot of DYI cords and repairs. I take additional steps on the wire ends after stripping. I solder the ends of the wires before clamping. Never had a problem with loose screws. Just the way I do it.

  • @tl1925
    @tl1925 2 роки тому +30

    Of course you knew you were going to get comments on your ultimate extension cord. Before you paint with the flex drill 2 holes in the top of the board 16" on center. When you're at a job site with open bays, you can fasten it right up to the wall and the holes will be premade in your wood to mount on the stud's. Even without it's a fantastic device!

    • @elvagabundo4607
      @elvagabundo4607 2 роки тому +6

      That is a fantastic addition T L. I bet we will see that in the next episode

  • @biblejournaling66
    @biblejournaling66 2 роки тому

    Love you guys thanks for all you do. I'm a retired electrician from Children's Hospital of Phila. And electrical Instructor.
    Suggest when using stranded wire under a screw terminal, twist the strands in the opposite direction so strands won't come out from under the screw head.
    God bless.

  • @clintprice2123
    @clintprice2123 2 роки тому +6

    Not only was this a great video it also showed items that many of us most likely never knew existed. The receptacle with the USB option not only saves counter space it eliminates the necessity for the little “brick” transformers which are just clutter once you’re done charging an item.
    The plug end gfi was another bonus.

    • @glennda5id
      @glennda5id 2 роки тому +1

      This is a good point and as someone who does their own electrical it is not a big deal for me to install the USB charging receptacles in my house. The issue I have, is that the USB charging standards keep evolving. i.e., they used to be 5w, then 10w, now some phones are upwards of 100w charging capabilities. Also the underlying protocol used (ex one of the newest is PD3.0 with PPS) keeps changing for optimal fast charging. So in the end, I prefer to swap bricks than to keep swapping receptacles. That being said, I think its a great addition to this extension cord where you want less clutter.

    • @clintprice2123
      @clintprice2123 2 роки тому +3

      @@glennda5id my son is a six year Tesla employee and he says fast charging harms a battery and slower is better. Using those cars as an example charging at home is far better than repeatedly using the supercharger stations.
      I have new/newer apple products and they came with larger wattage bricks but opt for the slower one as there is no need to rapid charge them.
      It’s personal choice.

  • @davewallace.8303
    @davewallace.8303 Рік тому +6

    Awesome video guys! I’ve done some wiring as well, totally within my wheelhouse to tackle something like this. Also, I like how you didn’t “dismiss” the safety “Karens” out there, but actually incorporated their suggestions! Very cool!

  • @chrisnash2154
    @chrisnash2154 2 роки тому +7

    I built version one a couple of months ago and I love it. I will probably build a simpler version of this super ext cord, but I’m not a fan of that huge yellow GFI box. Love the built-in mount/cord wrap and love that it’s rubberized. The point is you guys pointed out that the bus bars we build are far better than the ones sold in the big box stores. They are also customized to our needs.

  • @____________________________.x
    @____________________________.x 11 місяців тому +3

    Yes, wago connectors, nice to see them being used. Actually my favourite takeaway was the mounting board with cable wrapping ears and a carrying handle, that’s a neat idea

  • @literallymyusername8291
    @literallymyusername8291 2 роки тому +15

    You guys are just the absolute best channel on UA-cam. Everything you do is gold!

    • @DiffEQ
      @DiffEQ 2 роки тому +1

      It used to be. Now it's all just contrived content and clickbait. It was much better when it was organic. It's what got people watching and then they sold out. It's cringy, now. At best. I revoked my subscription when I started realizing it was all for profit, now.

    • @literallymyusername8291
      @literallymyusername8291 2 роки тому

      @@DiffEQ So what if they make more money? That's the dream we all have, isn't it? We watch two down to Earth guys with some great skills for free, anytime; you don't have to pay anything. Plenty of time for plenty of more content that's more your style.

    • @DiffEQ
      @DiffEQ 2 роки тому +1

      @@literallymyusername8291 I didn't say there was anything wrong with making more money. And, no, that is not "the dream we all have." If it was, none of us would have served in the military or decided to teach in the public school system. What you didn't respond to is what I actually stated as my reasons for no longer enjoying/supporting the channel.

  • @randysmith9636
    @randysmith9636 Рік тому

    Lol, I understand it's a older video and this is my second time watching it.
    But, I couldn't help but smile remembering your opening statement about how you got bombarded with "you did that wrong" "my cousins uncles brother does it differently and he has been doing it for thirty years so he knows" so you produce a follow up video to address all of those keyboard warriors concerns.
    Couple of points, thank you for the shop vac explanation, I had no idea.
    Second I really enjoyed seeing some of the pieces that as a DIY person we do not normally see.
    Thanks for another great video brother.

  • @billsinclair7280
    @billsinclair7280 2 роки тому +6

    Although I don't remember exactly how long ago it was but somewhere in the neighborhood of 25 years ago I was faced with an extension cord with a bad female end. I didn't have a replacement handy but I did have a metal two gang box and some receptacles, so I put them on the end of the cord and still have that cord today. It makes a pretty versatile extension cord where I can actually plug in four different things. It's really handy when you're working on a job and you're using a drill and a saw and a light and God knows what else and you can plug them all into the one cord so you don't have to unplug something to plug something else in every time you want to switch tools. Anyway, great video that is an awesome ultimate extension cord.

  • @rogerwhiting9310
    @rogerwhiting9310 2 роки тому +11

    I have been wiring devices all my life. With few alterations I think this was spot on. As usual I would personalize it for my own particular needs...but it was the best homeowner instruction level one yet. I did a 240 volt 50 amp one off of a range plug and a small subpanel. It had 240v, 120v and gfi protection. DEFINITELY not water resistant or OSHA approved. I can weld with it and run anything 120v ..with full breaker protection. Not pretty either.

    • @c_mac7773
      @c_mac7773 2 роки тому

      Please show me how to make one. I travel a lot doing repairs anything from roofing to repairing/welding damaged hand railing.

  • @cjsmith1760
    @cjsmith1760 2 роки тому +62

    As a retired electrician I complement you on the extension cord. However I must throw a word of caution about the paddle connections. For this application it probably wouldn't be a problem but having years experience in the oilfield electrial equipment and vibrations having a tight twist on the stranded wire under the paddle connectors will become a loose connection. The natural twist of the wire is good. The tight twist over time will relax.

    • @donfrost9457
      @donfrost9457 2 роки тому +10

      I was thinking the same. We always tinned the conductor with a little solder to strengthen the mechanical connection.

    • @mleboeuf8764
      @mleboeuf8764 2 роки тому +4

      It explain why we needed to re-screw connections of breaker box and terminals after a day or 2, to be sure the wire werent loose. Solid wires needed little tighting, but stranded wire where the always loose. So, we twisted too much ! Thanks !

    • @raygunsforronnie847
      @raygunsforronnie847 2 роки тому +13

      @@donfrost9457 Solder will cold-flow under compression. I was taught to use copper ferrules.

    • @JasonfromMinnesota
      @JasonfromMinnesota 2 роки тому +1

      I never twist strand wire much

    • @N719SM
      @N719SM 2 роки тому +2

      Also a retired wireman. Whenever I would find stranded wires under a screw in this manner, the thought that would come to mind is that the guy who wired it was just plain lazy.

  • @conniesisco6468
    @conniesisco6468 2 роки тому +4

    Absolutely FANTASTIC camera work! Super close shots of every thoroughly explained step. What a GREAT team.

  • @MrTimdtoolman1
    @MrTimdtoolman1 Рік тому +3

    As a 20 year contractor I found your video to be very entertaining, educational, and useful. My OCD flared up when you mismatched the colors on the plates and plugs, but AL in all, a great vid guys as usual. Thanks for representing the construction field so well. Keep up the awesome vids.

  • @dandexinventor
    @dandexinventor 2 роки тому +4

    I like it! The one change I will make is a spool because wrapping cords around static cord storage twists them. I like a detachable cord (from the board), with one of those sunk-in cord sockets, which helps with the spool being simple as well as allows any extension-cord to be use.
    Thanks guys!

    • @DingleFlop
      @DingleFlop Рік тому

      That's a great idea actually, the retraction mechanisms in those tend to be quite bulky/heavy but it seems perfect for an application like this

  • @RambozoClown
    @RambozoClown 2 роки тому +22

    Your typical circuit breaker has two trip modes, a magnetic and a thermal. The magnetic will trip instantly for high currents like a dead short, while the thermal portion can handle brief overloads to allow motors and other high inrush devices to start. The datasheet for the breaker will have the curves, but typically most will handle 200% for about 10 seconds, 150% for 100 seconds.

    • @jamesa8851
      @jamesa8851 Рік тому +1

      Or its a challenger breaker lol.

  • @GodlessDad
    @GodlessDad Рік тому

    I know it was just a throwaway comment, but I had to say this; a set of Felo automatic strippers made my workflow so much better. I build a lot of custom electronics and AV/data systems. Stripping wires to the proper length in 2-5 seconds rather than 15-30 can turn a 16 hour day into 10 hours.

  • @MatthewJRedmond
    @MatthewJRedmond 2 роки тому +5

    Definitely using this idea at work. I do the same type of work as you 2 and love watching your content to see how you guys do things down south as I'm up in Vermont. This will definitely help on the jobs when we're packing places to plug in and keep the cord from getting tangled when it's in the job trailer. Keep up the great work 😁 👍

  • @desdecardo
    @desdecardo 2 роки тому

    You may or may not believe this, but since I saw your original video I've been using your trick to remove the outer covering for a power cord. No nicks in any of the conductors. I can personally attest that it works for cords up to 10awg, 4 conductors. One of the best things I ever learned off UA-cam.

  • @Sway787
    @Sway787 2 роки тому +3

    Loved this build! I think I'll make a smaller one but I'll use the outdoor boxes with the lids attached.

  • @brandong6204
    @brandong6204 2 роки тому

    The first video I ever saw of yours was the extension cord repair video you mentioned at the beginning. It was a YT recommended video. I've watch every one since, and gone back to watch a lot of your older videos. Keep up the great (team) work.

  • @ayuse01
    @ayuse01 2 роки тому +38

    A breaker is a Thermo-Magnetic over current protection device. The '' Thermo'' portion of the breaker consist of a bi-metallic* strip of metal that is heated by a resistor in series with the load *( two dissimilar metals fused together, each having their own thermal expansion coefficient, thus creating a curve in the metal strip when subjected to a heat source. ). this flexion of the bi metallic strip of metal is used to trigger the breaker opening mechanism. the bigger the overload, the faster it heats up, the quicker it trigger.
    On the other hand, in the event of a pure short circuit, the Amps drawn can easily climb to 1000 amps on a 15 amps line in a fraction of a second, too fast for the bi-metallic system to react in order to prevent the wires from glowing red. This is where the ''Magnetic'' portion of the breaker comes into play, inside the breaker the load/amps have to pass thru a coil of wire that act as an electro-magnet, but just when huge amount of current pass thru it, so when a pure short is present with thousands of amps, the electro-magnet pulls the triggering mechanism of the breaker and opens the circuit. Simple design, very effective.

    • @thankswezilow6794
      @thankswezilow6794 2 роки тому

      I would say the ohms resistance on this build extension cord is one of the best in the industry compared against other multiple outlets connectors. which is why others burn up. I believe the breaker is set to an average resistance for the regular consumer and bc this was diy built the breaker did not trip. but thats not a real world test bc nothing like that is ever that close each tool is usally in its own area so may be adding some 25 ft to 50 ft extension cords would really load test the breaker and and and the load when cutting is higher so may be performing an actual cut for testing will pull more than 28 amps for sure

    • @thankswezilow6794
      @thankswezilow6794 2 роки тому

      great explanation by the way!

    • @randacnam7321
      @randacnam7321 2 роки тому +2

      Not all breakers are thermomagnetic. The breakers in a lot of power strips and inverters are usually thermal only.

    • @terrancevangemert7508
      @terrancevangemert7508 2 роки тому +1

      @@randacnam7321 That is very true and hospitals and other more health related places have thermal protection and magnetic action as does homes or residential.
      Canadian standards now do not accept any breakers that do not have at minimum Thermal and magnetic trips.

    • @ayuse01
      @ayuse01 2 роки тому +1

      There is also GFCI, AFCI, and so on, but for the sake of simplicity i talked about the most common house panel model.

  • @RichardBronosky
    @RichardBronosky 2 роки тому +2

    26:16 Okay, last Dad comment (on this video :-) for you. When you wrap a cord in a loop as you are doing, you are introducing a twist. The conductors inside are twisted, and the strands of each conductor are also twisted. This compounding effect is what causes old cords to the get the "umbilical cord" damage. However, with the quality of cord you are using here, that is never going to become apparent (as evidenced by the age of this 3 generation cord). Even so there is still a good reason to use my Dad's Navy wrap method. The Navy wrap is to make a figure eight on the side opposite the handle. This has 1 immediate benefit of not obstructing the outlets. But also each pair of wraps is a 1/2 twist minus a 1/2 reverse twist. Here's an exercise: If you extend the cord only 1 foot because that is all you need at first but then later decide to take out the rest of the cord to move your tool farther away, you can do so without unplugging anything. The cord will be straight. No twists. Try that exercise both ways. It's mind blowing.

  • @brianwood5220
    @brianwood5220 2 роки тому +9

    Great job guys. I too am an Electrician, but i think the overload has been well explained as to what's happening. Loved your super extension. Thanks for sharing 😃

    • @DiffEQ
      @DiffEQ 2 роки тому +2

      You thought the 12AWG stranded falling of the ground screw was something to "love"? No 15A receptacle is designed to hold a 12AWG stranded conductor on a ground as it is NOT a current carrying conductor and is actually sized smaller than the requisite 14AWG. He's two gauges too large and that screw is NOT holding it as he claims.

    • @TheDarthJesus
      @TheDarthJesus 2 роки тому +2

      It's simply an old breaker, failing to trip.

    • @elidanko1912
      @elidanko1912 2 роки тому

      @@DiffEQ He should be fine, because in case of a ground fault it would just trip the GFCI.

  • @jackstevens585
    @jackstevens585 2 роки тому

    I had a great time watching this video. I’m a novice, just getting started working on the farm. Sixteen years old. I learned so much. And there’s even more information in the comments.

  • @vsetkoumiera7683
    @vsetkoumiera7683 2 роки тому +3

    I made up a cord and box exactly like yours minus the USB plugs ( it was before everyone needed a USB plug to survive the day)
    I made mine using 12G SO cord, 100 feet long and it’s laid out in sun light, rain, snow, ice and anything Mother Nature can throw at it and it’s still working great, with hardly no voltage drop too

  • @rjfree7169
    @rjfree7169 Місяць тому

    First of all, awesome build!!!
    I’m not an electrician but I would like to attempt an answer to the question of why the breaker didn’t trip when it was overloaded.
    My answer is because the circuit is protected by a GFCI breaker which are designed to protect people from electrical shock, rather than prevent damage to a building's wiring. It does that by monitoring the current on the hot wire and the neutral wire and as long as the current on both wires is the same it will not trip. It will only trip after the wires become melted from the overloaded circuit and become shorted out. The shorted hot wire will then and only then cause the GFCI breaker to trip.

  • @mw3261
    @mw3261 2 роки тому +34

    You can also use a seam ripper (used for removing stitches in clothes) to cut the wire shield off, it works for automotive wire harnesses good. Love the videos!!

    • @jbman413
      @jbman413 2 роки тому +6

      I worked with a retired AVCM (Don Noise) for a short time; who told me he also used a seam ripper to cut “spot tie” on on wiring harnesses. He was absolutely correct works much better than dykes, knife or scissors. Thanks for the tip.

    • @randydewees7338
      @randydewees7338 Рік тому +2

      Suggestion - get your own ripper, don't use your wife's

    • @AllanSmith-vy2nn
      @AllanSmith-vy2nn Рік тому

      Been there Done That Now Divorced with holes in my pants@@randydewees7338

  • @llewellyn56
    @llewellyn56 2 роки тому

    I’m so sorry. People think they know better. Your videos are great. Thank you. Very educational.

  • @stevebowser7248
    @stevebowser7248 2 роки тому +4

    Great content as always! You always do a great job of the full explanation. Great point on the shop vac, its the principle of conservation of energy. The USB plug devices are the new best thing to add at strategic locations in a house. If one does ANY work on their home, this channel is must watch, hands down.

  • @LaurenKingAllen
    @LaurenKingAllen Рік тому

    This is a fantastic project. Real men improve shit and prove they are secure in their self worth by listening to feedback instead of getting defensive. Love it!

  • @anneriordon4131
    @anneriordon4131 2 роки тому +7

    Paul and Jordan you guys are next level. I am currently finishing a media room that includes 11 speakers and a 47" direct vent zero clearance gas fireplace. When i get a break i really enjoy watching and learning from your content!!!!

  • @aqueousone
    @aqueousone 2 роки тому +2

    Love it! On mine, I’m going to put the high capacity receptacle closer to the cord and not at the end of two sets of 12g jumpers so it gets first dibs on current coming into the boxes. I’ll switch a 15a receptacle instead of the 20a since that’s more likely where I’ll be plugging in lights, and I think I’ll mount the indicator light on the side of the last box. Since I have to drill a hole anyway it may as well be on the side. That’ll free up a position for another receptacle. If you wrap the cord in a figure ‘8’ pattern for storage it won’t put twists in the cord.

  • @Moccy.
    @Moccy. 2 роки тому +9

    Nice job as always guys, love your videos!
    Not an electrician, just a DIY enthusiast, but a couple things stuck out to me:
    1. You only need stranded wire if the wire can be moved around (e.g. the extension cord bit, or in a flexible conduit) - internal to the boxes between devices can be solid without issue, and would be easier to connect.
    2. Seems to me if you have a 20-amp receptacle, I think technically you'd need a 20 amp plug on the supply end to physically prevent you from using a 15-amp outlet. I suspect that inline GFCI is only rated for 15 amps.
    3. It's a shame the strain relief on this one didn't have the flexible spring to prevent hard angles at the connection.
    Keep killing it! :D

    • @monkeysuncle2816
      @monkeysuncle2816 2 роки тому +2

      I was wondering that, myself: what happens when you try to plug a 20a tool into that extension cord that is plugged into a 15a wall outlet.

    • @danlux4954
      @danlux4954 2 роки тому +1

      I would have used solid wire inside there, especially on the ground.

    • @TheDarthJesus
      @TheDarthJesus 2 роки тому +2

      @@monkeysuncle2816 It'll always trip, the 20a tool is goign to use more than 12a (nuisance trip threshold for a 15a breaker)

    • @gn02020202
      @gn02020202 2 роки тому +1

      @@TheDarthJesus All the portal power tools I have are only 8a. Most 20a tools have some weight to them and will not be carries from job site to job site, such as a drill press, bandsaw, or a lathe.

    • @TheDarthJesus
      @TheDarthJesus 2 роки тому +1

      @@gn02020202 oh absolutely. I was simply saying that using the 20a plug on this "super extension cord" for a 20a tool, while plugging it into a standard 15a receptacle (which is rated for 12a continuous current as per the 80% rule) would cause the breakers to trip.

  • @SterlinNelson_VTXBuilders
    @SterlinNelson_VTXBuilders 2 роки тому

    Made 2 of the first cords. now I'll add this, as a custom cabinet builder these cords help big time onsite. I've seen them on jobsite but your video pushed me to finally make them, thank you.

  • @ib9rt
    @ib9rt 2 роки тому +128

    When you said NEMA 6-20 receptacle you meant to say NEMA 5-20 receptacle. The 5-20 is for 120 V 20 A, whereas the 6-20 is for 240 V 20 A. The plugs are different and are not interchangeable, so you can't accidentally plug a 120 V appliance into a 240 V outlet.

    • @jaydouglas1090
      @jaydouglas1090 2 роки тому +12

      Thank you, at least someone else besides me saw this.

    • @x35gaming
      @x35gaming 2 роки тому +6

      **magic smoke escapes**

    • @ghammer9773
      @ghammer9773 2 роки тому +3

      I came to the comments for this. The plug he popped up on screen was a 6-15 too.

    • @skellious
      @skellious 2 роки тому

      @@williamriven I was wondering that.

    • @25Nightops
      @25Nightops 2 роки тому +3

      @@williamriven Nema 5-15 plug can go into a 5-20 receptacle. Allowing this extension cord to work in a 5-15 or 5-20 receptacle. The 5-20 receptacle is switched, but has no indicator. This probably would have been a good place for a switch with a pilot light (illuminated when on). Is the deal up to code, since it lets you plug a 20A device into a 15A circuit? Probably not, but you can make a hell of a useful extension setup based off this idea.

  • @kenmatthews6476
    @kenmatthews6476 2 роки тому

    You are a brave man. Electricians are the biggest “know it all” as you know. They will critique you guys like crazy. Well, i enjoyed the video. You guys are naturals on camera.

  • @partytempo
    @partytempo 2 роки тому +37

    I love that y'all keep things as "live" as possible. Can't remove insulation on the first try? Tamper resistant receptacle being difficult? - Leave it in :)

  • @hazardi9214
    @hazardi9214 7 місяців тому

    Good video, Stud pack. Randomly came cross this older video of yours, i have been watching the new carage build videos like grazy everytime a new episode comes out! One thing i may add about the cord: here in Finland, i was taught in school to always make the cords ends connected so that the 3 wires inside the cable would be so that the ground is the longest wire, then the neutral the second longest and finally the hot to be the shortest cut of all the wires.
    This is so that even if the strain relief fails, the hot wire is the one that gets yanked out of the connection first, so that it would disconnect first in case of a fault. Neutral second because if the neutral would be the first to disconnect, it may in some cases destroy some appliances with the hot still connected. i think its because the electricity sometimes finds a other route inside the device and it can potentially be very bad for the device, like frying circuit boards and etc. Ground finally the longest so that the device is always grounded in case of something ripping the cable straight out of the cord. Happens more often than you think.

  • @jay9308
    @jay9308 2 роки тому +38

    Technically, your 28 amp load would have never overheated or damaged the wiring. #12 wire is designed to carry 30 amps without heating beyond 90 degrees Celsius. Most wire insulation won't melt until beyond 105 degrees Celsius. Look up the NEC wire ampacity table. We are limited to using #12 romex at 60 degrees Celsius (20 amps) because it's best not to push the limits of the cable when risking fires. Many inexperienced DIYers tend to push the limits of electrical wiring. The #12 triplex wire you used inside the boxes is indeed rated for 25 amps, as it is only limited to 75 degrees Celsius.

    • @asbestosfiber
      @asbestosfiber 2 роки тому +3

      You also have to realize that that wire may be in place for 50 years or more and the insulation may degrade. Also the abuse it may be subject too, so yeah you want a lot of room before you would hit the limits.

    • @hawk5602
      @hawk5602 2 роки тому +1

      The #14 Awg that's probably feeding this outdoor receptacle rated for 15A but has a 20A at 75 degrees Celsius and 25A at 90 degrees Celsius carrying capacity on a 15A breaker disagrees. :P

    • @jay9308
      @jay9308 2 роки тому +3

      @@hawk5602 I'm not encouraging anyone to draw 28 amps on a 15 amp circuit, just pointing out that the device they made up would survive a 28 amp load for a significant period of time.

  • @jspafford
    @jspafford Рік тому +2

    I would make it more like a regular distro box where the extension cable would plug into a male outlet at the top. That way if the cable gets cut you don’t have to rewire everything. And you can choose the length you need for the job so you don’t have all this extra heavy cable. And you can take the main part with you end of day and leave the cable.
    And have two 20 amp legs. And have small gfci breakers at the top to turn in each leg. To top two would be one 20 amp circuit. Next would be another 20 amp circuit. And the third I would put in 240v 20amp outlets. And outside covers on all outlets that allow you to keep a wire plugged in while closed. Covers with windows. Those covers are gonna break so fast.
    Also a small spd at the top might be a good idea being a job site with temp power and a bunch of high draw startup tools going off and on.
    Oh and put a nightlight electrical outlet on it so you can find it at night. Light sensor ones that turn on in the dark. That way even if you’re inside a dark area you’ll have light. And have it be modular.

  • @eshicks9514
    @eshicks9514 2 роки тому +11

    Small suggestion that I’ve seen on British plugs. They leave a bit of slack on the neutral and a little more on the ground so that, if something pulls the cord out of the plug, they detatch in a specific order - live 1st & ground last.

    • @mrmotofy
      @mrmotofy 2 роки тому

      Not a bad theory

    • @GeneralBBBlackSheep
      @GeneralBBBlackSheep 2 роки тому

      Very smart 🤓

    • @aarontooth
      @aarontooth Рік тому

      Good idea.. almost makes up for centuries of the British empire terrorizing most of the globe with rape and pillage. We wouldn't want the king's fancy little fingers getting the zap zap.

  • @joemitchell2909
    @joemitchell2909 2 роки тому

    Great team you guys are on camera. I live in SF Bay Area It's good to see you and your son working together. Most of the kids out here don't work in the trades or with their parents. They are lazy! I grew up working with my dad times never forgotten.

  • @desireeespinosa3954
    @desireeespinosa3954 2 роки тому +4

    Thank you guys. You both work your bootys off, and you still took time to make a fun personal video for all of us. Very generous and thoughtful. Boy oh boy doesn’t the world need more of that? 🥰
    Y’all rock

  • @duncantaylor3558
    @duncantaylor3558 Рік тому

    just watched both of the extension cord videos. I also had issues with the metal box (but it's so Robust that it needed a fix), this version of the extension cord is much more than we need. So the Original version is what we Made with some improvements. I live in the pacific north west we get rain from October to May so water is a problem on any job site. My solution was to fill all unused holes with JB Weld I also used some 80 grit sandpaper on the interior faces of the box and sprayed the interior with the flex seal rubber coating. I also used exterior plug covers so the unused plugs are sealed when not in use (the metal flip up kind with a gasket seal on each socket). I also take the time to place a pice of plastic tarp over the box and we always put it on top of something so its not directly on the ground, just incase we get a sudden shower while we're working. we tend to put up shade roofs over our tools again just incase. Remember kids electricity will kill you if you let it.
    Be Safe!!

  • @JHCCAZ
    @JHCCAZ 2 роки тому +60

    A small suggestion: The strain relief as mounted at the end of that little extending pipe (instead of being mounted through a plain hole in the panel wall of the box) could snap off if it gets tugged sideways really hard. You could reinforce it by adding a U-shaped 2-hole conduit or pipe strap, screwed to the board near the end of the strain relief.

    • @keithmills778
      @keithmills778 2 роки тому +3

      You can get strain reliefs that glue right into the box. That's probably a better solution than extending the strain relief further from the box.

    • @jimthesoundman8641
      @jimthesoundman8641 Рік тому +1

      The thing you are speaking of is properly called a "gland nut" as a strain relief is actually what he showed on the first version of the extension cord from the previous video. And I agree, the cord should be fastened to the plywood before that point.

  • @robertt8273
    @robertt8273 Рік тому +1

    Great video, i made one based on this video except one change. I used an outdoor box with a cover over the outlets when stuff is plugged in. I did that for the rare times one of my kids grab it to power their campsite in the rain. It is great.

  • @georgewilliams8228
    @georgewilliams8228 2 роки тому +10

    Love the build. One thing I would be concerned about is the life span of those cover plates. Corners have a good chance of snagging. A frame around the boxes so they have something to sit on should be an easy fix.

    • @jefferyjanssen4723
      @jefferyjanssen4723 2 роки тому +1

      I came to the comments specifically to find this. It was the first thing I thought of as well.

    • @69nunyabidness
      @69nunyabidness 2 роки тому +4

      Being a tin bender, AKA metal fabricator, I immediately started to design the enclosure in my head. It's a character flaw!

  • @rusosure7
    @rusosure7 2 роки тому

    Seeing you leave a bit of green insulation on to prevent the stranded from splaying was well worth the price of admission.

  • @yutubl
    @yutubl 2 роки тому +5

    Really usefull idea! For better safety always make the protective wire longer than hot and cold wire, so that it's the last wire that can be drawn loose in the case of a loosen clamping plate.

  • @JamesChasingSunrises
    @JamesChasingSunrises 2 роки тому

    Came across this video and loved every minute of it. More joy when I realized I was already subscribed! The comment section is absolutely amazing as well. Great community!

  • @wcvp
    @wcvp 2 роки тому +26

    The breaker didn't trip because it's not supposed to. Generally, home breakers will allow you to pull between 100% and 125% of the rated current indefinitely. The more over the rated current you are, the faster it will trip, so you can draw about 200% to 300% of the rated current for about 10 seconds. A dead short is far less than a second. I would link a breaker trip curve example, but youtube sometimes flags comments with links as spam. If you look one up, you'll see there are 2 lines, and the area between them is the "might trip, might not trip" zone (and is commonly shaded), so when you're sizing breakers for larger equipment, you need to make sure that your load will always stay to the left side of the left curve, including during startup, otherwise you'll hate yourself or other people will hate you.
    This might seem terrible, but it's actually a very good thing. When you turn on an inductive load (like an air compressor or saw), you get an insanely high current spike on startup, and the breaker tripping would make it completely useless. Yes, this is completely safe, copper has a lot of thermal mass so it takes a while to actually get hot and be a danger.
    Also I'm an electrical engineer, not an electrician :P

    • @dontworryaboutit3281
      @dontworryaboutit3281 2 роки тому

      Wrong

    • @wcvp
      @wcvp 2 роки тому +1

      @@dontworryaboutit3281 care to explain? I generally work on electronics so I haven’t done much with this since college

    • @dubmob151
      @dubmob151 2 роки тому

      @@wcvp I wouldn't worry about it. Just a random troll 🙃

  • @triplebee8peaceperiod887
    @triplebee8peaceperiod887 2 роки тому

    Hi I'm just a DYI guy, but like the power bar. I did borrow your general idea and added a one piece plywood backer under the switch plates. I found when you wrap the cord or plug in a device that is tight, the sides of the plate's were always breaking. Also made a portable vertical stand with a shelf that I can use were ever I go. Shelf can hold charging phones, boom box, etc. thanks :)

  • @sparksmcgee6641
    @sparksmcgee6641 2 роки тому +13

    Rotate the boxes 90 degrees. The wire on plugs that point down will tangle up across the other plugs. Having them point out instead of along the unit. Great job. Loved the hospital plug info. Great for heavy use and heavy load.

    • @user990077
      @user990077 2 роки тому +2

      If you rotate those plastic boxes then the conduit connections become more complicated with tees and would not be inline as they are in that build.

    • @sparksmcgee6641
      @sparksmcgee6641 2 роки тому

      @@user990077 No changing the device direction doesn't change conduit.

  • @FoxBonly
    @FoxBonly 2 роки тому

    Watching your custom extension videos was sooooooo instantly gratifying......

  • @lelandclayton5462
    @lelandclayton5462 2 роки тому +4

    I thought about making one like the smaller one you guys made but with an outlet with USB-A. However seeing the plywood backer for the cord wrap feature and hole to hang it got me thinking and possible add a few other features like a cradle to hold a phone while it charges. Maybe a little shelf with a hinge and kickstand.

  • @jessiemae6873
    @jessiemae6873 2 роки тому +1

    Years ago, I was at a safety meeting. A picture was shown of an extension cord wrapped around a "cord keeper" and had over heated overheated and caught fire. That impressed upon me so much that to this day 40 some years later, I always completely uncoil the extension from any "keeper" so the cord can have air circulate around it. My kids were small at that time and I instilled upon them and my wife to completely remove the cord, irregardless the length so it can "breathe". Granted the picture at the safety meeting was a worse-case scenario.
    I do like your complete idea, and am thinking about building my version, but I will have to unwrap the cord every time just because of that safety meeting picture. Thanks for the new cord.

    • @PhilDeGuzman
      @PhilDeGuzman 2 роки тому

      So I'm guessing you don't use one of those automatic cord retractors in your workshop. Or do you pull all the cord out when you use it?

    • @MrRustyjackson
      @MrRustyjackson 2 роки тому

      @@PhilDeGuzman I fried a nice Belden retractable cord when I used a Milwaukee heat gun and failed to pull the cord all the way out. Pulled out about 5', plugged in the heat gun and about 5 mins later... smoke and the smell of melting insulation!

  • @Tripring2000
    @Tripring2000 2 роки тому +7

    Would like to see the electrical panel and the manufacture and age of the breakers. Older breakers are prone to not sensing the overload as quickly as newer style ones. Depending on the manufacture of the breakers and manufacture date, there was a time when a few manufacturers had quality issues with maintaining the tolerance requirements for an overload condition.

    • @rupe53
      @rupe53 2 роки тому +1

      you must be talking about the Federal No-Arc panels and some Push-matics of the 50s and 60s.

  • @Terkinstein
    @Terkinstein Рік тому

    Wow that little bonus, showing the amp meter while clogging the vac was super interesting. And incredibly enlightening! Thanks Stud pack.

  • @PCHUGGER
    @PCHUGGER 2 роки тому +11

    Awesome job! Those screws on the sides of electrical outlets are very interesting. I used to think they were a combination of Slotted and Phillips, but I was wrong. Slotted screwdrivers don’t work well as they can slide around too easily. Phillips head screwdrivers in those screws work better, but these screws are not designed for Phillips drive. You can see in the middle of the screw a square hole (not a pointed Phillips hole). This is called a Robertson drive (square drive). It fits perfectly (no sliding) and allows you to easily drive them even in odd positions. You can buy Robertson drivers at most tool outlets, but there is an even better solution that I recently discovered. Milwaukee makes an ECX driver that is specifically for electrical work (insulated down to the tip). The ECX driver is a combination of Slotted and Robertson drives. It’s been great for my amateur electrical work. It comes in two sizes - #1 is for normal stuff. (Jordan - Father’s Day is coming).

    • @ranger178
      @ranger178 2 роки тому +5

      klein also makes screwdrivers labeled c1 and c2 for combination screws it is on my 15 in 1 ratcheting screwdriver from them it is starting to show up in newer assorted screwdriver tips packs also

    • @mrmotofy
      @mrmotofy 2 роки тому

      It's nice to see more and more devices moving away from the stripping Phillips

  • @HostInTheMachine
    @HostInTheMachine 11 місяців тому

    Screws on the outlet plates all aligned vertically; nice attention to detail. I thought I was the only one OCD enough to do that :). Great video; thx!!

  • @cww922
    @cww922 2 роки тому +4

    Loving the Ultimate cord, but I made two of the other cords which work perfect for my needs. Compliments to you Paul, you do a great job of explaining the process…..really helps the DYI'er. I’ve learned a great deal from you already, it worked be fun (for me) to work with you on a home project. Keep these cool videos coming, your doing a great job!

  • @EdLawless
    @EdLawless 2 роки тому

    I really like this idea. I inherited several cans on flex seal from my brother-in-law. He was an electrician by trade; not sure if he used it for this trick; but he loved the stuff. He bought it by the case. But I certainly think he would approve of your build. I am going to build something very similar out of spares in my shed and some scrap plywood. I will have to put my own little flare on it.

  • @theteenageengineer
    @theteenageengineer 2 роки тому +63

    The next thing I’d like to see is an extension cord that allows for 240 volt input and has a built in breaker panel on the board, that way you can run a really high power device like a table saw or a planer. You also get a nice advantage if you use 240 for the cord, because by adding one more wire and using a 4 conductor cord you can either run a 240 volt tool or you can split the phases and have twice as much power for 120 volts. You could also add one of those little voltage and current readout displays that way you know how much power you are drawing. And as for why the breaker didn’t trip at almost 30 amps, if it’s a 20 amp breaker it is expected to hold at 100% of its capacity (20A) and thermal trip at 125% of its rated capacity, and magnetic trip (short circuit) at 200% it’s rated capacity, thermal trips usually take a while, because when you have a current surge on say a saw it can often pull over 20 amps, and you don’t want the breaker to trip every time you start your saw. ElectricianU has a good video on that subject

    • @jimparker5185
      @jimparker5185 2 роки тому +1

      I think your point is twice the current when you split the 240v into 2 120v circuits. However, technically Power = Watts (unit of measure in the US) = Volts * Current (for DC anyways, AC is more complicated than what I'd do in youtube comments). When you halve the voltage from 240 to 120 and double the current, the power is exactly the same. 120v * 20A = 240v * 10A = 2400W. Though when talking about power tools, air compressors, and such with electric motors, from what I understand, the 240v motors tend to be more efficient and run on less power, but now the argument changes to apples to oranges.

    • @Engineer9736
      @Engineer9736 2 роки тому

      @@jimparker5185 His point is that you can run twice the amount of current through such extension cord. Either expressed in watts or amperes is irrelevant, it boils down to the same conclusion as the line voltage doesn't change. Two phases with the same wire diameter as they would have done at single phase means that you can draw twice the power from it. But i think this project was already a little bit shortsighted over the top (but perhaps fun if you have lots of time and materials left over), and they have proven that they can run 3 saws and a vacuum cleaner simultaneously on the current setup, so making it two phase is really something for when you're into your tenth year of retirement bored and really don't know anymore what to do.

    • @idadho
      @idadho 2 роки тому +3

      How often do you find a 240 circuit available? How many portable table saws or planers use 240? Those are usually shop equipment that might even be hard wired to their individual circuits.

    • @patricelebrasseur5649
      @patricelebrasseur5649 2 роки тому +1

      @@idadho dryer and range outlet are 120 /240v
      Compressor welder pvc heat box and large circular saw are the most likely to be 230v on a job site
      People usually use spider box in those instance

    • @idadho
      @idadho 2 роки тому +1

      @@patricelebrasseur5649 In the US, tools are 110 unless they are shop mount grade/not portable. Nobody takes a 220-230-240v compressor to the job site. A portable welder would have a gas engine to run a generator and probably be 50 amp, at least 30 amp. A 220v saw is a shop saw. They use 220 vs 110 to save on electricity costs. They are a bit cheaper to run. The Teenage Engineer does not know what he is talking about. A 30 amp 240 circuit only has 30 amps per leg. No power tool uses 30 amps on 110.
      Finding an available 240 circuit is not likely on a job site.

  • @Lawrence330
    @Lawrence330 2 роки тому +1

    I really love this project. I have been meaning to make a couple of boards like that to coil my extension cords, but I didn't think to integrate the receptacle boxes like that.
    Instead, I built a steel box to hold a 20A 120V duplex and a 50A-style 240V receptacle (for my welder and grinders). There was no way that I'd find the right combo cover plate for that at the home center! I like the idea of the separate 2-gang boxes, I think I'll rebuild my breakout box this summer and add the board, too!
    Thanks guys!

  • @getyourbone
    @getyourbone 2 роки тому +2

    The most amazing part of this is that you decided to film it to show those that haven’t been doing the same for years how to do it…one doesn’t realize that everyone else doesn’t already know this…👍👍👍🙏🏻🙏🏻🙏🏻