How to Diagnose Problems with a Hot Water Heating System | Ask This Old House

Поділитися
Вставка
  • Опубліковано 28 січ 2017
  • Ask This Old House plumbing and heating expert Richard Trethewey helps a homeowner figure out why one of her radiators is not working.
    SUBSCRIBE to This Old House: bit.ly/SubscribeThisOldHouse
    Richard identified that the 1950s era home he visited was piped with a diverter tee setup, where a single, combined supply and return line runs from the boiler.In part of Richard’s explanation on the radiator, he explained the diverter tee in the dual piping to each radiator. The diverter tee slow-stems the flow of water at one end, increasing the back pressure and forcing the water through the first pipe and into the radiator.
    Time: varies
    Cost: varies
    Skill Level: Difficult
    Steps:
    1. Richard goes over some of the places to check when adequate heat is not being delivered from a forced hot water heating system.
    2. In this home, which means the water heats up in the boiler, goes up through the pipes, through the radiators, gives off heat to the room, and falls back down to the boiler to be heated again. That process is helped via an electric circulator pump which can be tested to ensure it is working properly.
    3. With any forced hot water system, there must be the right amount of water pressure going into the boiler and to the pipes. To help that, a pressure reducing valve lessens the amount of water pressure from the city to the boiler. The pressure reducing valve can be tested and a pressure gauge on the boiler will also indicate system pressure.
    4. An expansion tank to reduces the stress on the system. The top portion is filled with water and the bottom air under pressure. In between the two, is a neoprene diaphragm to act as a shock absorber to the pressure. If that diaphragm fails, it can cause problems with the system.
    5. If only one radiator is failing to give off heat, check the air valve to determine if there is any excess air in the system.
    6. Check the shut off valve going in to the radiator, which may have been turned off for service or an attempt at zoning.
    Richard showed 3/4-inch copper monoflo tees. Those can be found at local home centers or plumbing supply stores.
    After diagnosing a hand valve that was inadvertently turned off, Richard used the Flir One infrared camera attachment for a smart phone manufactured by Flir [www.flir.com/] to confirm that heat was reaching all parts of the radiator.
    About Ask This Old House TV:
    Homeowners have a virtual truckload of questions for us on smaller projects, and we're ready to answer. Ask This Old House solves the steady stream of home improvement problems faced by our viewers-and we make house calls! Ask This Old House features some familiar faces from This Old House, including Kevin O'Connor, general contractor Tom Silva, plumbing and heating expert Richard Trethewey, and landscape contractor Roger Cook.
    Looking for more step by step guidance on how to complete projects around the house? Join This Old House INSIDER to stream over 1,000 episodes commercial-free: bit.ly/2GPiYbH
    Plus, download our FREE app for full-episode streaming to your connected TV, phone or tablet: www.thisoldhouse.com/pages/st...
    Follow This Old House and Ask This Old House:
    Facebook: bit.ly/ThisOldHouseFB
    Twitter: bit.ly/ThisOldHouseTwitter
    bit.ly/AskTOHTwitter
    Pinterest: bit.ly/ThisOldHousePinterest
    Instagram: bit.ly/ThisOldHouseIG
    bit.ly/AskTOHIG
    For more on This Old House and Ask This Old House, visit us at: bit.ly/ThisOldHouseWebsite
    How to Diagnose Problems with a Hot Water Heating System | Ask This Old House
    / thisoldhouse
  • Навчання та стиль

КОМЕНТАРІ • 350

  • @JesusJuenger
    @JesusJuenger 5 років тому +120

    "My radiator's not hot"
    *Richard reads out the entire text of War and Peace.*
    "Better check the valve is open."

    • @wholeNwon
      @wholeNwon 4 роки тому +5

      It's a TV show.

    • @rogeraldrich2533
      @rogeraldrich2533 3 роки тому +1

      I agree! This man can talk the ears off a snake. Right now I am sitting in a cold house trying to diagnose my problem and I wasted seven minutes listening to this guy babble about interstate highways in the fifties.

    • @johngarcia8827
      @johngarcia8827 2 роки тому

      " It was the 50s. The double helix was discovered, Eisenhower was President and it was the beginning of the Red Scare. And these homes had a single heating system ! "

    • @johngarcia8827
      @johngarcia8827 2 роки тому

      Tonight on This Cold House

  • @cardo1111
    @cardo1111 5 років тому +12

    Richard is the plumbing professor, he really loves what he does and it shows.

  • @ChristopherOlson-xh6sy
    @ChristopherOlson-xh6sy 11 місяців тому +41

    This was an exact replacement for the old one that lasted about 10 years. ua-cam.com/users/postUgkx7yWIKcrbA9KMHkGSfcgxW2lsjHT6B8Sh The top of my mitigation tube by my roofline was just a 90 elbow which allowed too much debris to fall down into the fan, eventually ruining it. Without this issue, I bet it would have kept running another 10 years. When I replaced this fan, I added an extra elbow joint so the top tube now it does a 180, which should solve that problem. The radon guys around here wanted to charge me a $300 diagnostic fee, then parts/labor (probably close to $600 total). I installed this all by myself in about an hour for the cost of the fan; it would probably be even easier/faster with two people. FYI the manufacturer's warranty greatly differs depending on whether you install it yourself (1 yr warranty) or have a licensed installer do it (10 yrs).

  • @piepawrench
    @piepawrench 3 роки тому +12

    I've always told my boys & grandsons and anyone else that I may be helping with any problem "mechanical", "always look first for the simple things, first". Good advice gentlemen!

  • @matoatlantis
    @matoatlantis Рік тому +9

    I absolutely love Richard's explanations on things. To know and to know how to explain are too different things too.

  • @MMKLYH
    @MMKLYH 5 років тому +13

    Imagine a valve shut, and this guy explains a full heating system to you

  • @richardwhite6288
    @richardwhite6288 2 роки тому +8

    A plumber that's honest...and takes his shoes off when entering your home..
    Definitely a keeper! Great job, Richard!

  • @robertbrown6934
    @robertbrown6934 4 роки тому +20

    I appreciated the troubleshooting steps. Thank you for this video.

  • @dawoodhussain2085
    @dawoodhussain2085 3 роки тому +7

    I love your videos man , they are so practical, spot on and problem solving ! A great shout to you from the plumbers and Gas technicians!

  • @bellegreycats490
    @bellegreycats490 4 роки тому +1

    I just love this program. Saved me so many times over. It’s good to understand How things work so you can do maintenance on your own home yourself.

  • @funnyguylol69
    @funnyguylol69 7 років тому +164

    The valve would literally be the first thing anyone would check.. It's same as, "Is it plugged in?".

    • @NinjaTenK
      @NinjaTenK 7 років тому

      mikeye9 Well they recently moved it so I think they thought it was on or didn't know how it worked

    • @paulschmidt7473
      @paulschmidt7473 6 років тому +12

      Usually those valves were previously opened or closed by an 800lb gorilla with wrench and a 12' cheater bar, and there ain't no way that thing is going to turn....

    • @shellyslioneyes
      @shellyslioneyes 6 років тому +3

      I'm a 5'3" women and I have no problem turning mine on and off. LOL

    • @BeatsWithTeeth
      @BeatsWithTeeth 6 років тому +2

      luckily you met the height requirement then

    • @Blox117
      @Blox117 6 років тому

      did you try turning it off and then on again?

  • @crumplezone1
    @crumplezone1 7 років тому +6

    Richard is so great to listen too, awesome show guys

  • @nickbailey202
    @nickbailey202 2 роки тому +2

    Hours of Googling to understand my system and Rich nails it for me in 7 minutes.

  • @DuncanCunningham
    @DuncanCunningham 7 років тому +3

    Like in computers, "have you turned it off and on again ". I liked learning how it worked though. Richard is a great teacher.

  • @luigib7311
    @luigib7311 2 роки тому +2

    Wow! Thank you for the simple explanation. I never knew how the water was forced into one side of the reladiator.

  • @Guillotines_For_Globalists
    @Guillotines_For_Globalists 7 років тому +375

    Her husband can build radiator covers but can't check to see if a valve is closed? Lame!

    • @KingMikeUK
      @KingMikeUK 6 років тому +26

      Maybe its a set up.

    • @dogan6070
      @dogan6070 6 років тому +8

      Blaine Bugaski be nice pls

    • @nigelfrancis1706
      @nigelfrancis1706 6 років тому +13

      This guy is awesome. He use Ike’s highways as a temporal analogy. I learn so much from him - he makes me wish i’d been a plumber like my grandpa.

    • @paulinedounia655
      @paulinedounia655 6 років тому +1

      GuvvaduHflgligli

    • @yesmychannelfamio
      @yesmychannelfamio 6 років тому

      New house they said, meaning he just built those covers.

  • @andrew.triggs
    @andrew.triggs 7 років тому +214

    In real life the HVAC guy would try to upsell the home owner to get a new boiler

    • @RiouInsuiko
      @RiouInsuiko 6 років тому +2

      I know I would; System 2000 is garbage. Unless you're a specialist and have inventory, good luck getting parts for it.

    • @ezq6664
      @ezq6664 5 років тому +5

      System 2000 is one of the best units you can buy....controls are more sophisticated but you get used to it like anything else....economy is great on them....

    • @cardo1111
      @cardo1111 5 років тому

      Well said. Sad but often true.

    • @saulgoodman2018
      @saulgoodman2018 5 років тому +6

      If it still works, why replace it?

    • @07slowbalt
      @07slowbalt 3 роки тому +2

      First of all an hvac guy wouldnt be trying to sell them a boiler he would be trying to sell them a furnace. Get your facts straight because that would be a completely different trade and equipment.

  • @MshAhmxiO1
    @MshAhmxiO1 6 років тому +3

    Thank you Richard, very helpful! I bled my system & my heat is working again, easy.

  • @philliphawkins3062
    @philliphawkins3062 6 місяців тому

    THANK YOU THANK YOU THANK YOU!!!! I was able to get my daughter's bedroom warm again! The valve was off on her radiator

  • @juanrf2122
    @juanrf2122 4 роки тому

    Great explanation of how the radiator heater works

  • @afghankodak7468
    @afghankodak7468 6 років тому +6

    Thanks and this was an amazing informative video.

  • @thebnbaldwin
    @thebnbaldwin Рік тому

    Good point. I chased an electrical problem for 30 minutes last week in an old house that has been remodeled and re-wired several times, only to reset a GFCI outlet in the kitchen to restore power in an adjacent room.

  • @jaxson3887
    @jaxson3887 4 роки тому

    Thanks for the clear explanation.

  • @Viggggggr
    @Viggggggr 6 років тому +16

    "My light switch is off but there is no light in my room!!!! I think it's time to call a repair man! "

    • @ninjastah
      @ninjastah 5 років тому +2

      *spends 8 minutes analysing light switch*
      "Yep... Looks like it's off... You gotta flick the switch... That should solve the problem".... 👍.
      "thanks sir"
      "No problem.... That'll be $322"

    • @walterbrunswick
      @walterbrunswick 5 років тому +1

      @@ninjastah "Sir, do you have a permit to turn that light switch on?"

    • @ninjastah
      @ninjastah 5 років тому +1

      @@walterbrunswick Permits are needed for clap 👏 👏 sensor lights not normal light switches. I have a level 6 in light switch theory! Please respect my credentials. Good day sir

  • @andrews6323
    @andrews6323 Рік тому

    This show is a national treasure

  • @Altenarian
    @Altenarian 7 років тому +13

    They do have beautiful floors though.

  • @otiscampbell2194
    @otiscampbell2194 4 роки тому

    I was right ! ! Check the valve ! ! Simple things first ! ! Thanks for showing the simple things too ! ! We can all learn from this ! !👍👍👍👍👍👍👍👍👍👍

  • @AFG647
    @AFG647 6 років тому +40

    If it was a NY plumber
    You would have to put a new boiler

    • @mikegee3991
      @mikegee3991 5 років тому +1

      You can say that again! just imagine he she wasn't following him around!!!

  • @steelcitytv
    @steelcitytv 7 років тому +4

    i love that their still at it i been watching since I was 10 I'm 25 now still love the show when i was in high school they had a awesome we built real house watching this always make me want to get back in to the field

    • @bremello5917
      @bremello5917 5 років тому

      What if the hydronic tank is bad and the valve and pipes and the meter goes bad does that raise your gas bill?

  • @hempcacaogoji831
    @hempcacaogoji831 Рік тому +1

    Reminds me of a plumbing job I was working on several months ago. The boiler wasn't firing and they had no idea why. I went and checked the oil tank, dead empty.

  • @ryans413
    @ryans413 3 роки тому +1

    This guy explained everything pretty well

  • @DOLRED
    @DOLRED 7 років тому +4

    Brings back memories as a kid. We had steam heat in the apartments we resided in--one pipe system. There was always a radiator which was weaker than the rest. No amount of valve turning or draining did much. Being on 3rd floors, we credited it to being far from the boiler. Some of the darn things would leak from the valve if not fully opened. We had metal radiator covers in one place which had water trays laid inside the top. You could fill them with water (Humidifier). Somewhat useless I recall. For 25 years now have had hot water heat. The biggest crisis in 2013 was discovering the pressure gauge was inaccurate, reading nearly 15#s high and the pressure reducing valve was plugged up (Calcified) and not working. So the boiler was low on water and not producing enough heat. After fixing those, all is well. Now I have 2 pressure gauges on it!

    • @wholeNwon
      @wholeNwon 4 роки тому

      I assume you tightened the packing nuts on the leaking valves to stop the leaking.

  • @TheHobbyShopFilms
    @TheHobbyShopFilms 7 років тому

    LOL, I watched this on Public TV on Saturday. I think that is the 1st thing I would have checked!

  • @marcosgoldin5623
    @marcosgoldin5623 3 роки тому

    Thank you for this great video. Greetings from Perú

  • @Blobjonblob
    @Blobjonblob 7 років тому +94

    So he explained all that and it was just turned off at the valve lol

    • @michaelfarm
      @michaelfarm 7 років тому +2

      I watched this today on tv and got a chuckle out of it.

    • @larrybe2900
      @larrybe2900 7 років тому

      +iShootBandits Wouldn't been much of a show otherwise.
      My thinking is the design of the covers. I understand the aesthetic idea of wanting to make the look different but the efficiency is reduced by covering the top of the radiator. Cutting slots in the top would allow the heat to raise naturally and freely. Probably not a big issue but worth noting. IMO

    • @QuadroNVS
      @QuadroNVS 7 років тому

      I thought something was up when Richard was educating that homeowner about how a boiler works and comparing her piping to a a highway....I learned a thing or two but I cannot say the same out the homeowner.

    • @shellyslioneyes
      @shellyslioneyes 6 років тому

      If you have kids, they will burn the crap out of them. Also, have you ever tried dusting those stupid things? Do you have any tips? I have these heaters. I hate them. Nothing fits between or behind them. The covers are MANDATORY. I have 4 in my apartment and only 2 covers. I wish her husband would come and build me 2 more covers. UGH! So nasty and my neighbor downstairs doesn't turn them on 1/2 the time. My heat is supposed to be included in rent and my electric is sky high trying to supplement the fact that neighbor is "too hot". (I live in OH btw.)

    • @Guillotines_For_Globalists
      @Guillotines_For_Globalists 4 роки тому

      @@shellyslioneyes Your downstairs neighbor controls your heat? That might be illegal, actually. Speak with your landlord about it.

  • @johnspanos3862
    @johnspanos3862 2 роки тому

    Best part about this video is that system 2000! Just got mine done last week in our 1980s colonial with baseboard heating (we got the system 2000 Resolute RT). I'd love to rip the baseboards out and put radiators in like this woman has... Is that something that can easily be done? Love your videos!!!

  • @sultandamani9069
    @sultandamani9069 5 років тому +1

    Thanks for sharing knoledge

  • @cjpcle
    @cjpcle 3 роки тому

    I'm sure you knew right away. Thanks for the wealth of information though!

  • @Arieeeee
    @Arieeeee 7 років тому +1

    Lol this is the equivalent of an electrician going to a house, troubleshooting an issue and finding out a breaker was tripped.

  • @hubert-williams3379
    @hubert-williams3379 3 роки тому

    Hey there I am a huge fan of your show.. I am a diyer..I am currently diagnosing why my relief valve tripped the other day.. I understand more about the expansion tank and how it work.. Ok I have a fairly new system.... LOGANO/Budreus GC 124 II installed 2013 two days before Sandy Hit. The problem I'm having is not sure how to drain my system so that I can replace the expansion tank, I can see all the shut off valves and drain valve..I'm just not confident in executing this proceedure. The expansion tank is 7yrs old the pressure was calibrated about 4yrs ago to 12psi that's what it's rated for. I just need some reassurance and direction going forward. I have two circulation pumps directly under the drain spouts ..This is a two zone 3 zone system but only set up for two.

  • @metalfoxssmallenginerepair3181
    @metalfoxssmallenginerepair3181 2 роки тому

    Great diag. Very very nice of you

  • @TheGalacticWest
    @TheGalacticWest 2 роки тому +1

    Husband: creates masterpiece radiator cover.
    Husband: what is a valve?

  • @l.crossjr
    @l.crossjr 7 років тому +1

    Richard my hero

  • @verystablegenius8316
    @verystablegenius8316 6 років тому

    Outstanding video

  • @Progrocker70
    @Progrocker70 9 місяців тому

    Unusual to see a '50s era home with cast iron radiators but nice that they chose those instead of the cheap sheet metal fin tube.

  • @tedlahm5740
    @tedlahm5740 4 роки тому +3

    Mono flow system. First time hearing about that.

  • @tomekc1113
    @tomekc1113 3 роки тому +1

    great job!

  • @razikhan8079
    @razikhan8079 4 роки тому +7

    Husband out of town and "SHE" needed a plumber👨🏻‍🔧 😜😜🤣🤣🥰

  • @19flamingo92
    @19flamingo92 6 років тому +11

    Sling blade: Ain’t no gas in it.

  • @benjaminfeltz
    @benjaminfeltz 4 роки тому

    I love this story.

  • @MechanicalMikesRoadsideRepair
    @MechanicalMikesRoadsideRepair 7 років тому +14

    I wish I could get a job I liked like these guys...They get paid good and look happy doing it.

    • @BlueFlyer21
      @BlueFlyer21 7 років тому +2

      get paid good ? lol

    • @michaelfarm
      @michaelfarm 7 років тому +1

      Damn! Criticize much asshole?

    • @Arieeeee
      @Arieeeee 7 років тому +6

      All these guys have paid their dues crawling in attics and crawl spaces.

    • @saulgoodman2018
      @saulgoodman2018 7 років тому +1

      I don't think they make that much. But they all have their own business. I don't know if Kevin does.

    • @MechanicalMikesRoadsideRepair
      @MechanicalMikesRoadsideRepair 7 років тому

      I know Tom and his brother I believe have a general contracting business out in the boston area so they must make some decent money

  • @kyleking284
    @kyleking284 2 роки тому

    WOW!! That was an extremely helpful video! 👍 I know nothing about heating plumbing systems, but after watching this I can now diagnose my problem!😊 Thank you so much for this video🙏❤

  • @joshua-pu2os
    @joshua-pu2os 4 роки тому

    very helpful

  • @goldenogregames
    @goldenogregames 3 роки тому +1

    Her house is beautiful. She's probably waiting the normal 8-10 weeks for furniture delivery. I ordered a couch and they're like, yea should see it be November. As for the valve, she seems like a nice lady who doesn't have a clue on how things work. But also, it doesn't mean that they didn't purposely do that since he had an elaborate explanation and a copper T just to illustrate it.

  • @evarsonazevedo5321
    @evarsonazevedo5321 3 роки тому

    That's a great video!

  • @raymondlee8351
    @raymondlee8351 3 роки тому

    Hi Richard. My house have same monoflow system or called one pipe system. The "T" fittings from the main pipe go up to upper floors. My question is I have two more floor above this Ts fittings and radiators almost on same location to two floors, and how they connect together? Are they in series? Can anyone help please?

  • @jimwamboltsoutdoorworld6795

    My viessman 100-w propane boiler shuts off. I turn the power switch off wait 30 seconds or so. Turn it back on and it may be good for a couple of days before it does it again. It does have an outside temperature monitor. I wondered if it could be that?

  • @josephnorcalusa1710
    @josephnorcalusa1710 6 років тому +1

    that's a old house but is good to know 👍👍👍 !!!

  • @fvc524
    @fvc524 4 роки тому

    I have a steel convector element that's hammering when the steam is going up to the second floor.
    I've level it and chance the air valve & still it's hammering.what can I do?

  • @TrainFlood
    @TrainFlood 10 місяців тому

    Nice Kinetics boiler system!

  • @WannaBeDj100
    @WannaBeDj100 7 років тому +2

    Always check the simple things.

  • @juddbrady1825
    @juddbrady1825 3 роки тому

    0.49 magic !
    Shoes back on!

  • @0v110
    @0v110 8 місяців тому

    I have the similar heating system. There is a water dropping sound come out of the wall further most from the heating system, whenever the heat is on.
    Could be an issue with plumbing?

  • @jamedlock83
    @jamedlock83 3 роки тому

    4:54 "you with me"?
    Me: "No, I lost you on the ramp"

  • @briansounalath
    @briansounalath 2 роки тому

    I trust this guy with my life

  • @howardwhite9773
    @howardwhite9773 7 років тому +1

    check the fuse before disassembling the air conditioning compressor.

  • @oilman614
    @oilman614 Рік тому

    Nice boiler 👍

  • @zekenzy6486
    @zekenzy6486 7 років тому

    awesome

  • @felixfernandez442
    @felixfernandez442 5 років тому

    How to conect 6 ft long cast iron baseboard radiator using the same existing coopers pipe of regular radiator.

  • @casperaudi7476
    @casperaudi7476 7 років тому +3

    Thank you for the history lesson great job is it worth buying a house with those old radiators.

    • @shellyslioneyes
      @shellyslioneyes 6 років тому

      No NO NO. Get a furnace

    • @jenniferbyrne8334
      @jenniferbyrne8334 6 років тому +3

      Radiators are not obsolete! I never understand people who rip out hydronic systems and change to forced air or rip out cast Iron radiators and put in copper - aluminum fin baseboard. A properly designed hydronic system with a modern boiler such as the one in this video provides great comfort. Radiators provide even lasting warmth and are efficient with modern properly sized boilers. Just stay away from gravity hydronic systems with no circulators and massive boilers / huge water volume.

    • @lizcademy4809
      @lizcademy4809 4 роки тому +1

      The only thing a radiator system doesn't do better than a furnace is keep your house cool in summer. For some of us, this is not an issue. For others, it's a deal-breaker.

    • @wholeNwon
      @wholeNwon 4 роки тому

      Unless you find radiators unsightly, if the system is in good condition, hydronic systems are great. But, if natural gas were available, I would want a gas boiler to supply them instead of oil.

  • @lostintime8651
    @lostintime8651 7 років тому +3

    I had one zone not working. Pulled motor on zone valve. Tested continuity on end switch. Good there. Motor not turning. Pulled wire off in control box. Installed jumper. Powered up. Motor turning.
    Pulled thermostat. Connected wires. Tested wire near boiler. Had continuity. Hooked it all back. Still not calling for heat.
    Hmmm....
    Cut and stripped wires at control box. Hooked up again. WORKING!! Hooked up thermostat again. Still working.
    Conclusion. Corroded thermostat wire at the control box.

  • @WA-hornet007
    @WA-hornet007 4 роки тому

    Awesome video , I have water and gas heating baseboard system though we are getting heat but it looks like our system is using gas to provide heat , I don’t hear water going through baseboard pipe , what could be wrong with it ?

    • @wholeNwon
      @wholeNwon 4 роки тому +1

      There's no reason to hear water moving through the pipes unless there's some air in the system. Getting good heat? Then don't worry about it.

  • @opasgarage4423
    @opasgarage4423 Рік тому +1

    That was a easy fix. But what would the MOST LIKELY problem have been if it wasn't the shut off valve? We've been in our house for several years, the warmest radiator in the house has always been in the dining room. It is December in Indiana and we've been running the boiler for over a month with no issues. Today we noticed the dining room was cold and when I checked the radiator it was COLD AS ICE! the radiator before and after that radiator were working fine. I opened the bleed valve I was able to bleed 2 gallons of COLD water out with NO air and good, steady water pressure.
    What could my problem be?

  • @mikegee3991
    @mikegee3991 5 років тому +19

    That'll be 200 bucks please!

    • @ninjastah
      @ninjastah 5 років тому

      Bahahahahha

    • @thejpkotor
      @thejpkotor 4 роки тому

      Fro real though

    • @Southpaw07
      @Southpaw07 3 роки тому

      300 on weekends. thanks to plumbers but some of them are real rip-offs

  • @cielbleue100
    @cielbleue100 2 роки тому

    Initially my oil boiler was providing hot water to the house but now that I installed an electric water heater how can I stop the boiler from providing hot water and only use it to just heat the house please

  • @bobbelsekwol
    @bobbelsekwol 6 років тому +25

    My electric light won't work. Should I move house? Ffs.

    • @wholeNwon
      @wholeNwon 4 роки тому +2

      First let's discuss how a hydroelectric dam works.

  • @k.b.392
    @k.b.392 5 місяців тому

    I have a leak at the boiler base; left, front corner with a faucet. What can be causing this leak???

  • @craigtaylor3139
    @craigtaylor3139 2 роки тому

    Here is my problem with hot hot water heating I have a 1915 two story house with cast iron radiators AND baseboard fin heaters in the kitchen. The kitchen heaters and the boiler a just a few years old. The kitchen base board heatersdo not even get warm.
    So I turned off every radiator in the house the copper pipe in the kitchen got so hot it burned my hand. I have then valved off now.

  • @matthewv4086
    @matthewv4086 4 роки тому +1

    Hi,
    I want to remove end cap from a 1 1/2 copper pipe. I have drained all the water from the pipes. No matter how much i tourch the pipe the solder doesn't soften. I am using mac pro. Under the exact condition, i have removed end cap from the second pipe 1 1/4 inch. The solder melted in 5 minutes.
    What seems to be the issue here? Do i need a hotter torch or a different technique? Help me if you can. Thank you.

    • @OkayAhhgain
      @OkayAhhgain 4 роки тому

      Matthew V old solder joints have lead in them so you have to really heat them up. Just be careful when you wrench on them to pull the cap off. The copper pipe will get soft and if you warp the pipe and cap then you will never get it off

  • @mr.dahliaking.202
    @mr.dahliaking.202 7 років тому

    my cast iron radiators burst in my kitchen and above sleeping room, cause the main branch clogged with sludge, and four cast iron rads didn't work, and froze, and burst some sections in the rads. I was on holiday. Question for Richard - can I disassemble the radiator and take out the damaged sections and then rebuild it again with only good sections? Or is it going to leak? Maybe the frozen water weakend the integrity of cast iron? I don't know, help please. Changing the whole rads are expensive. They are each 20 sections, and only about 2 to 5 sections broke per radiator.

    • @pcno2832
      @pcno2832 5 років тому

      Maybe you could combine the leftover fins from 4 bad ones to make 2 good ones, then get 2 new ones to complete the system. One thing I can say about the cheap fin-tube baseboard radiators we have in the USA is that they never clog and almost never leak; they last forever as long as you don't kick them.

  • @christopherdekonstrukt444
    @christopherdekonstrukt444 Рік тому

    I have the exact opposite problem most people come to this channel. I bought a house 18 months ago, and always had hot water available. So I assumed the water heater in the garage was electric and working. Come to find out it solely uses natural gas and never has been on since I moved in. Kind of embarrassing to find that out now, however since I had hot water I assumed it was working. There's no breaker for an electric heater and I haven't been able to find an inline heater anywhere in the house. So, how am I getting hot water?

  • @fly3209
    @fly3209 7 років тому

    That thermo-graphic camera attached to the smart phone, what model is it and from where did you get it?

    • @alexp191
      @alexp191 7 років тому

      it's a Flir thermal imaging camera

  • @thomasceo
    @thomasceo 6 років тому +1

    I have a loud high pitched ringing noise coming from only one of my steam radiators, any ideas on how to fix this?

    • @squirrelfish8200
      @squirrelfish8200 5 років тому +3

      Sounds like a partially closed valve is causing pressure to build before it reaches that radiator (think: tea kettle) make sure all the valves are entirely opened or entirely closed (if you want the radiator off- no halfsies, it's hard on the system when you bottle neck pressure on a valve)
      If that doesn't work make sure the radiator is not perfectly flat- though non-draining condensation usually causes a knocking it could be spray dropletts screaming through as they evaporate (should tilt about 5 degrees towards the exit to drain)
      If it's not the easy stuff get a bubble-blowing mixture (even a water-dish soap mix) apply it liberally around all the valves and crevices. See any bubbles or any places where the mixture is drying quickly or being pushed away while it's whistling? You have a leak and the kettle noise is explained. Replace it, call a pro or if time are tough and you have to have a band aid for now: form-a-gasket used in engine repairs (a tube of goop like j b weld) holds out well enough for a couple of seasons but it takes 24 hours to set 48 if you get the good stuff so the radiator has to be off for that time. If you can, place a tiny, form fit, piece of tin foil over the leak and make-a-gasket over the foil so none gets into the radiator itself.
      NOTE: if the leak is at the bleeder valve do NOT MAKE A GASKET over it. Call a pro, it has to be replaced.
      Still no?
      The last cause I know of (but don't know a trick for) is sometimes the inlet/outlet valves are mixed up and you need to pull down the radiator and switch them back.

  • @rud
    @rud 7 років тому

    I think I have too many episodes when I just sit here and wait for Richard to lift his hands slowly and say something like "it goes up through here"?(or something like that) :D And now that was replaced by an animation. :)

  • @blackbox6841
    @blackbox6841 4 роки тому

    👋 hello,
    How to work sterilizing machines please explain

  • @russellmoore8187
    @russellmoore8187 5 років тому +3

    This lady and I were both like “why tf are we talking about ww2” but then Richard brought it home 👍

  • @stanleykeith6969
    @stanleykeith6969 4 роки тому

    Hi Richard, if you read this do you have a video that tells me if a radiator can be plug up and how to unclog it and if I drain the system how do I flush it out. Its up on the second floor. 9 room house and sometimes I hear water dripping on the burners. I need your Help.

    • @wholeNwon
      @wholeNwon 4 роки тому

      What do you mean "water dripping on the burners"?

  • @wandrak
    @wandrak 5 років тому

    Great plumber :D :D Checks everything in the house, from radiator to boiler, but LAST thing whitch he checks if there is air in radiator or closed valve? LOL :D

    • @squirrelfish8200
      @squirrelfish8200 5 років тому +1

      Man has to make a show for the camera. Can't travel all the way there just to have 10 seconds of him saying "it's switched off, honey dew."

  • @normanboyes4983
    @normanboyes4983 7 років тому

    Nice one BUT what would have been your next steps in the diagnosis IF the valve had been open?

    • @willdogsdroid
      @willdogsdroid 7 років тому

      Simple, bad valve. Replace the valve that she had turned off.

    • @jacksonbennett6151
      @jacksonbennett6151 7 років тому

      I was thinking it could have been sediment on top of the venturi restricting the flow.

  • @Guitarmanjhc1
    @Guitarmanjhc1 4 роки тому

    I live in an very old mansion turned into apartments. I live upstairs in #4 , It was built in 1865, I have no idea how old the water radiators are, but my bedroom radiator valve has a wooden knob on the valve and its not moving cant get it to open or close, been stuck like this for many years, Ive lived here 25 years. Im not the owner I just rent. My bedroom often is not very warm and gets pretty cold in fall and spring because I don't think the radiator is getting enough water, when the maintenance guy bled it there was a lot of air in the radiator before any water came out. Any suggestions o could tell him?

    • @wholeNwon
      @wholeNwon 4 роки тому +1

      Bleed it again to be sure that air hasn't gotten in there once more. It's common not to be able to move those old valves. They are usually stuck in the open position as evidenced by his ability to bleed them. When the boiler shuts off because the room thermostat has been satisfied, check the temp. of the boiler gauge and the pressure. They should meet the necessary specs. Take a thermometer and measure the temp at your radiator and that of some others on the same floor.
      If yours is too low, you may have a case for inadequate water flow from a blocked valve or poor flow from the boiler as Richard showed.

  • @frank5angels308
    @frank5angels308 2 роки тому

    I have a Bryant Gas Fired Water Boiler (1973) model 234 (nat Gas) that has always worked but today its not. I turn up the Thermostat for Call to heat and I see Pilot light go on and then the burners got on (Orange flame mostly) for a few seconds and then go out but Pilot reignites relighting the main burners etc.. This cycles 5 or 6 times and then it all shuts down Until I shut down the unit and restart the call for heat> I looked for some type of flame sensor but dont see one so I am not sure what to do. Any Ideas ?

  • @thethinbluelineZ06
    @thethinbluelineZ06 4 роки тому +2

    Her husband was so skillful enough to make that elaborate cover, but not smart enough to check the valve?? Maybe his wife turned it off purposely so she could see the Plumber 😉

  • @55jigme
    @55jigme 5 років тому

    here you guys located ? or your main office?

  • @AandWProductions
    @AandWProductions 5 років тому

    I have the same issue. One radiator that doesn't get heat (in the master bed to boot). No air trapped, no valves that could be off. Only thought is a clog. Any other ideas?

    • @wholeNwon
      @wholeNwon 4 роки тому

      That radiator has no valve? All other radiators on the same floor get hot? When you bleed that radiator you get a GOOD flow of water.

  • @SteelCityJW
    @SteelCityJW 5 років тому +4

    Now i know how to turn on a valve! Look out America!

  • @CliffTooth
    @CliffTooth 2 роки тому

    Thermographic camera. Amazing

  • @brianmaier7529
    @brianmaier7529 5 років тому

    Why wasn't the valve the first thing that was checked?

  • @kennyplay5982
    @kennyplay5982 6 років тому +1

    question. i have the same type system. 1 zone. monoflow valve. At some point, previous owners changed from poor mans cast iron radiators to single finned copper baseboard radiators. I have a baseboard radiator that doesnt get completely hot. It only has 1 bleed valve. And Ive bled that often but still only hot at the end bleed valve. Any suggestions?? thanks

    • @sparkzbarca
      @sparkzbarca 6 років тому +1

      It's either blockage or pressure. To test them both you swap two radiators, you move that to another radiators position and move the other one to it. If after swapping the ROOM now has the same problem with the changed radiator, you know it's pipe/pressure. If the problem follows the radiator and not the room, and in the new location that radiator still has the problem you know you've got a blockage in the radiator. This if I had to guess would be some kind of lime etc build up, hard deposits and such. You may be able to clear such a blockage by trying to flush the radiator with CLR (calcium, lime, rust remover) or another such product.

    • @kennyplay5982
      @kennyplay5982 6 років тому

      thank you!

    • @michaeldillabough8744
      @michaeldillabough8744 6 років тому

      kenny play finned tube baseboard rads are desighned to have direct flow thru them,not mono flow like explained in video,you will have to find your intake line coming off the main and the return tieing back into the main and install a isolation valve on the main line between the two ,once installed between the two shut it off,this will force all of the heating water through your finned tube rad and then back into the main and on its way to the rest of the home and back to the boiler

    • @kennyplay5982
      @kennyplay5982 6 років тому

      i see, let me go over this, and share with a plumber heater person, thanks

    • @pcno2832
      @pcno2832 5 років тому

      @@michaeldillabough8744 Fin-tube radiators are also used with monoflow systems; mine are plumbed like this, and each one has a bleeder valve. One thing to watch for is whether the radiator is level; if it's not, the bleeder won't work unless it's on the high end.

  • @ericschexnayder1196
    @ericschexnayder1196 Рік тому

    I once paid and electrician to come out and troubleshoot a set of outlets that weren't getting power. Turned out that a hidden GFCI had tripped. So I ended up paying the electrician to reset a GFCI. Can't judge too harshly here.

  • @manu93ize
    @manu93ize 6 років тому +2

    this guy is construction professor