How to set hot water boiler pressure

Поділитися
Вставка
  • Опубліковано 10 бер 2021
  • This video will describe the concepts and process involved in setting the water pressure in hot water boiler systems.
    Before you grab your free class, make sure to subscribe to my channel: bit.ly/SubscribeHVACTraining
    Sign up to get access to a free class “Using Digital Multimeters For HVAC” by going to my website and clicking on the "Subscribe" tab :
    hvactraining.squarespace.com/
    🔥🔥🔥 ACCESS USEFUL PLAYLIST 🔥🔥🔥
    Thermostat Mini Series bit.ly/howathermostatworks
    📍 FOLLOW HVAC Service Mentor 📍
    🔹 Official Site: hvactraining.squarespace.com/
    🔹 Facebook: / hvacservicementor
    🔹 Twitter: / hvacmentor
    🔹 LinkedIn: www.linkedin.com/in/ericshidell
    These training sessions are for qualified HVAC technicians or apprentices under proper supervision. None of these trainings are meant for DIYers or HVAC hobbyists.

КОМЕНТАРІ • 81

  • @Rein_Ciarfella
    @Rein_Ciarfella Рік тому +2

    More, MORE!!! :) I've watched dozens of boiler/burner/coil/overall familiarization videos over the past couple days and yours was by far among the best. Really great production values, volume, everything. Easy to comprehend and follow. Now, please do an entire series on residential boiler systems, theory of operation, parts, diagnosis, repair and servicing for the novice. I know that's a lot, but judging by the number of people commenting here and everywhere else I've been in 48+ hours, there's certainly a demand for articulate presenters doing a great job teaching. If I had the time and $ I'd choose you to teach me wherever you might be lecturing.
    Also, if you catch this comment, please try to take the time to respond to more comments. I know that's time-consuming and probably tedious at times, but it makes a huge difference to those of us out here who are trying to understand and deal with their home systems.
    Thanks for reading and keep up the great work!

  • @rdb8509
    @rdb8509 Рік тому +3

    Very nicely done. I am a mechanical engineer and have my PE license. Been doing this for +30yrs. I sent this video to my neighbor who has a HW hydronic heating system in his house which is not common here in GA. He was wondering what pressure to set his fill PRV at and this video had just the right mix of technical and layman language to be easily understood. Thanks!

  • @joepops5186
    @joepops5186 3 роки тому +3

    very good info, the hardest part i find in hvac is not always getting the field experience of different types of systems and these videos bring back some lost knowledge from school years ago.or just doing install you dont learn much about how they run,just thread pipe!

  • @jeffreysmith3704
    @jeffreysmith3704 9 місяців тому +2

    This is one of the best instructional videos I have watched. Very informative on boiler pressure settings and overall technical explanation in layman terms! Thanks for making this available, gave me just what i was looking for on doing some annual boiler maintenance in my home.

  • @jaybones614
    @jaybones614 Рік тому +1

    I'm trying to understand the hydronic system in my house and this video helped more than others. Thanks

  • @dl7279
    @dl7279 3 роки тому +2

    Great explanation! I learned quite a bit from this video.

  • @stephenzies8867
    @stephenzies8867 2 роки тому +3

    Wow You Are Awesome And A Fantastic Educator Thank You !

  • @pkelly8816
    @pkelly8816 Рік тому

    Best simple presentation I've seen. Thanks much.

  • @vyasconstruction4829
    @vyasconstruction4829 Рік тому

    You are a gifted teacher! 👍

  • @raymondburns6675
    @raymondburns6675 2 роки тому +1

    Thank you for your information I find it very very helpful to solve my problem

  • @BLAZE21000
    @BLAZE21000 Рік тому

    I had no idea what the psi really did within my system and where it should be set but now I absolutely get because of you.
    A big Fonz to you…
    👍 AAAAAAAAAAAAAA 👍

  • @user-vw6oe4zf6y
    @user-vw6oe4zf6y 14 днів тому

    Awesome very intuitive helped me understand it.

  • @cavy95
    @cavy95 8 місяців тому +2

    My oil boiler is at 23psi, in a raised ranch, max height on boards is 11 feet. How do I reduce the pressure in the system? I just replaced the pressure relieve valve and back flow for $185, only to have the backflow leak 2 hours later. I bleed the line of air about a month ago, maybe I accidentally increased the pressure from 12psi?

  • @Glennhairston
    @Glennhairston Рік тому

    Excellent explanation thank you

  • @josephgarbowski2030
    @josephgarbowski2030 2 роки тому

    Fantastic video very educational

  • @piscis12
    @piscis12 Рік тому +1

    Excellent, very good.

  • @edvaioli7340
    @edvaioli7340 Рік тому

    Excellent! Thank you.

  • @anonymouslyominous3
    @anonymouslyominous3 Рік тому +1

    Thank you very helpful

  • @andrewthacker114
    @andrewthacker114 2 роки тому

    Great information thanks

  • @edpowell3077
    @edpowell3077 2 роки тому

    Great video thanks

  • @oq17
    @oq17 Рік тому +3

    This was the best - most clear explanation I’ve ever seen .
    To round this out a bit , can you do a tutorial on setting , checking and adjusting the expansion tank .
    I think the water inlet pressure you just explained and the expansion tank set point go hand in hand.
    I have a basic idea - but I’m still missing something on the expansion tank setup
    Thank you so much !

  • @soloch69
    @soloch69 2 роки тому

    Great video 👍🏻

  • @martincollins4008
    @martincollins4008 6 місяців тому

    Very Useful information.

  • @alimovahedian4860
    @alimovahedian4860 Рік тому

    Dear eng
    Your lecture on oiler pressure, thanks so much.
    If this technical information , combine by few pictures,
    It will be so usefull for technician to get ideas and use in his life.
    Best wishes

  • @warrenlange6106
    @warrenlange6106 2 роки тому

    Excellent video. Thanks so much.

  • @bobluby2962
    @bobluby2962 2 роки тому

    very good inf thk you

  • @fredsangster9327
    @fredsangster9327 4 місяці тому

    Very good makes it easy to understand thankd

  • @cjaquilino
    @cjaquilino Рік тому +1

    @7:05 It's Christmas Day. I had no heat after flushing water out of my system. There was air in my pipes. But when it came to refilling my boiler, I could not just open the valve to the water, because I have this backflow preventer.
    It did what you said and it did refill the boiler. I did it until 15psi. But in retightening the bolt, apparently I screwed it too tightly and broke the piece inside of there.
    Heat is back on. But obviously I'm gonna have to extract that part and replace it, or replace the whole backflow preventer. I shut off the valve feeding fresh water into the boiler/backflow preventer.
    So hopefully, I'm at least good for tonight. It's going down to 11F tonight.

  • @NathanThePrezPretlow
    @NathanThePrezPretlow Рік тому

    When I try to decrease the water pressure on my boiler it still goes pass 30 PSI for my two family house which I only need 13 to 15 psi.The reducer valve is about two year old so it's fairly still new.Is it possible the hot water temp.Or is my new circulating pump .What do you think ? Also what the recomemed H/W temperature for hydronic system for a two family house.

  • @rotorway133
    @rotorway133 Рік тому

    Replaced the Xtrol and pressure release valve. Pressure goes up to about 35-40 psi ans spills out. Bad regulator?

  • @NathanThePrezPretlow
    @NathanThePrezPretlow 2 роки тому

    What water pressure setting should I set for a two-family house.? and whats a good hot water temperature should I set the thermostat.?

  • @davidskific207
    @davidskific207 2 роки тому

    I have a 2 year old Slant Fin Sentinel SE-140 EDP Boiler. The PRV was releasing water so I changed PRV & Expansion Tank. Boiler is still releasing water while running and pressure gauge shows 30psi. I know it should be 12-15pdsi while running. How do I lower pressure from 30psi to 12psi.

  • @KTHKUHNKK
    @KTHKUHNKK Рік тому

    Hello my friend.
    I listen to you very closely as I worked on my system.
    I turned down the pressure relief valve just as you said at the most I believe I want half a turn. My whole system is on one floor ground floor.
    My pressure leaf valve has been blowing.
    Is it possible I don't have enough air in my expansion tank ?
    I have very bad eyesight so it's hard for me to see a tire gauge.
    But I believe that my expansion tank only had three to six pounds in it.
    Where is the manual calls for 12 PSI.
    Can you give me any further suggestions why I'm having a small problem here.
    I did subscribe and I hit the bell.
    Keith Kuhn

  • @justinlocke
    @justinlocke 2 роки тому

    fab info... i was looking for a "bleeding radiators for dummies" show :-) altho the bleeding part is sort of sort simple but what if the system does not have enough pressure to push water up to like 3rd floor? why does bleeding just a little water completely resuscitate a radiator? does a system re-pressurize by itself after bleeding? thanks- jl

    • @Rein_Ciarfella
      @Rein_Ciarfella Рік тому

      Guessing here, but I think they're talking about bleeding the air out of the system, not water!

  • @jaxmann4899
    @jaxmann4899 8 місяців тому

    Okay so I have a question. I have my oil/hot water furnace system, and I've been having this nagging problem about my highest point in the system which does not heat. It's about 25ft up and the boiler pressure is set to 23psi. I called my current HVAC company and they increased the pressure to almost 30psi which did work for a bit but now the pressure has gone back down to 23psi and it cannot heat the upstairs floor now. There are no leaks, blockages, air trapped, or any kind of a flow problem, and the circulator pump for the upstairs zone is new. I don't understand it because 23psi should be more than enought to cover this. Any ideas?

  • @pellechi1
    @pellechi1 7 місяців тому

    Very educational … thanks. Quick question about your very last statement … when the cold water fill pressure is within the 5 psi of the relief valve (30psi), what is the proper technique to reduce that cold water pressure back to 25psi without introducing air into the system?

    • @hvacservicementor
      @hvacservicementor  4 місяці тому

      Water under pressure, when released through a drain valve, will not allow air to enter as long as the pressure does not drop below zero at the top of the system or near any air vents.

  • @adamr8628
    @adamr8628 Рік тому

    I just had my boiler system worked on and the pressure was set at about 20 when they were here. Pressure got up to 35 today and I called them and they told me to close the supply line valve and turn out a bleed screw on one of my zones and let some water off. This screw is at the end of an approx 1/4 line that comes off the first elbow of the zone supply pipe going up. Is this the proper way to bleed off some pressure? Will this introduce any air?

    • @cavy95
      @cavy95 8 місяців тому

      Did this work? No response from the host.

  • @topherdean1024
    @topherdean1024 6 місяців тому

    I'm restoring an old home with a Burnam Hydronic system. I removed one of the radiators to work in that area and bypassed the radiator with a piece of pipe. This winter I noticed that the pressure relief valve was venting. I surmised that the pressure increased because of the removal of a radiator. I don't know how long the boiler was venting, possibly a few months, but everything seems OK. I'm gradually lowering the pressure until the max pressure is less than 30. I did notice that when the boiler was off, the pressure read about 12 PSI, but I observed it was over 30 when actively heating. I guess there's no way to do the math when the system is on, so I'll just keep going down there and checking when the system comes on.

    • @hvacservicementor
      @hvacservicementor  4 місяці тому

      this is why my channel is not for DIYers. You need to call a professional to fix this. Removing the rad did not cause these symptoms.

  • @rl4889
    @rl4889 Рік тому +1

    6:35 adjust the valve

  • @stephenalibozek1058
    @stephenalibozek1058 2 роки тому +1

    I understand when it’s cold what the pressure would be but once it heats up what would the pressure be

  • @ranger178
    @ranger178 6 місяців тому

    might want to mention the expansion tank in this video talking about system pressures when cold and such.
    would also be interesting to actually take a fill valve and take the top off and show the rod and adjustment rather than just describing it with a picture of a valve on the screen.

    • @hvacservicementor
      @hvacservicementor  4 місяці тому

      My first boss in the business would have said, "So I'm hearing that you're volunteering to create that video for us?"

  • @robertmcdonnell6548
    @robertmcdonnell6548 9 місяців тому

    So when the set point is 15 psi is that with the pump running or off?

    • @hvacservicementor
      @hvacservicementor  9 місяців тому

      Pressure should be set when the system is not operating. I often refer to this as cold fill pressure or standing pressure. Ideally, for a system that has correct near boiler piping, the operation of the circulator will not affect the fill valve.

  • @woodrowcarter5367
    @woodrowcarter5367 2 роки тому

    You didn’t say to how to adjust the valve itself so that it didn’t slowly creep the pressure back up that it is set properly at the pri at the proper pressure, I have had him had them slowly leak into a higher pressure setting.

  • @donaldkain5132
    @donaldkain5132 7 місяців тому

    whre is the expansion tank? why is there not one to push back at the fill pressure valve to preveng overfilling a cold water fill pressure setting ?

    • @hvacservicementor
      @hvacservicementor  6 місяців тому +1

      Expansion tanks can be located anywhere near the boiler. Those that are mounted at the fill valve and "push back" as you say are called a "Filltrol" system where the pressure in the tank sets the cold fill pressure.

  • @garysmith9772
    @garysmith9772 3 роки тому +2

    A very important point is never leave the water turned on to a boiler make up valve if you read the B&G instructions it’ll tell you to shut that makeup water supply off. That’s only used to initially fill the system it’s not meant to maintain system water pressure.

    • @davelazarick9899
      @davelazarick9899 Рік тому

      Isn't this contrary to what this gentleman states in his tutorial as he says that the function of this valve is to introduce water into the system when the valve senses to little pressure and shuts down at the preset pressure?

    • @garysmith9772
      @garysmith9772 Рік тому +1

      @@davelazarick9899 Say for instance you had a leak in a copper line under a concrete floor and the fill valve just kept feeding water you would lime up the boiler up and ruin the boiler in no time. Every boiler system should have a low-water cut off so if the boiler did lose water it would shut the burner off as a safety which is required in most states. A pressure reducing valve is just a convenience to give you 12 psi on initially filling the system.

    • @Mike-rm7vf
      @Mike-rm7vf 11 місяців тому

      Great idea. Turn the water off that feeds the boiler.
      Turn the gas off to the burner also. If it leaks you might explode.
      Turn the electricity off as well because it just might electrocute your ass.
      Keep being a maintenance man. 😂

    • @garysmith9772
      @garysmith9772 10 місяців тому +1

      Why doesn’t Eric Seidel chime in on the correct answer will see what he has to say

    • @garysmith9772
      @garysmith9772 10 місяців тому +1

      Like it states in my first comment, the manufacture B&G actually tells you to shut off the water supply. Just read the instructions that came with the valve. You always go by the manufacturers recommendations.

  • @marcisaacs9407
    @marcisaacs9407 2 роки тому

    What about hot temperature pressure on the gauge? If it’s 12 lb cold then ………. Hot?

  • @bysykler4959
    @bysykler4959 6 місяців тому

    My boiler pressure gauge shows a reading of about zero when cold. However, when heating, it jumps up to about 25 (which is fortunate since my pressure relief valve is 30psi). All radiators in my 2 story house work fine and have been air bled yearly. Is it normal for a gauge to operate in this manner?

    • @hvacservicementor
      @hvacservicementor  6 місяців тому

      NO. This is common, but not normal. This can happen when the expansion tank fails or becomes waterlogged, the pressure increases to the relief point, water is relieved, and then the water cools and shrinks and the pressure decreases. Simultaneously, the water makeup valve fails to admit more water to make up for what was lost. I call this a malfunctioning system that is working in spite of the defects.

    • @bysykler4959
      @bysykler4959 6 місяців тому

      Ok, thanks! Makes sense. On my system, there is no automatic water makeup valve. I add water manually with a ballcock valve as needed. Im assuming this isn't kosher either?

    • @hvacservicementor
      @hvacservicementor  6 місяців тому

      @@bysykler4959 The only systems I've seen like that were well over 50 years old. There are a lot of excellent reasons to invest in a new boiler if that's the case!

    • @bysykler4959
      @bysykler4959 6 місяців тому

      Well, you know what they say.... if the racehorse keeps winning, keep feeding it hay! 😅

  • @andreduvall2904
    @andreduvall2904 7 місяців тому

    I’m having similar problems to other people in this comment section. I have a 10-year-old Bryant cast-iron boiler. My house is just like the one in your description 4 stories, including the basement, boiler is at the bottom. My temperature is 104F and 25psi at rest. Before shutting off the temperature reaches 120F and 30 psi enough to make the new pressure relief valve drip.
    A month ago. I had a radiator on the third floor leak, I removed that radiator and capped off the pipes. I later noticed the original pressure relief valve leaking and replaced it. Now the new one drips occasionally.
    Does anybody know if by removing one radiator out of the system would it increase the water pressure? Expansion tank sounds hollow/empty all the way around.
    I did not drain the system when I changed the pressure relief valve. I only drained the third floor to cap off the leaking radiator. All radiators have been bled since then.
    Basically, I’m trying to figure out why my water pressure changed after doing those two repairs.
    Thanks in advance

    • @hvacservicementor
      @hvacservicementor  4 місяці тому

      You have an expansion tank probelm. That is outside the scope of this video. Stop diying boilers. Call a pro and be done with it. If you knew how dangerous this can be, you wouldn't sleep at night.

  • @boomer1049
    @boomer1049 8 місяців тому

    I need some answers. I change my tank and it still blowing the relief valve 😢 So I went back and bought a new relief valve and it's still blowing the relief valve 😢 So I went back and bought and input regulator valve and its still blowing the relief valve 😢 So now I want the truth what the heck is going on??? My pressure is hitting 30psi which is to high because that's what the relief valve is set to blow off. Please help me it's the weekend and I have been fighting this the last few days 😮

    • @DobraLLC
      @DobraLLC 7 місяців тому +1

      Did you figure out what’s wrong? I’m facing the same situation right now. I replaced my pressure relief valve which is 30psi. Today I added a new Bell & Gossett pressure reducing valve which is set at 12psi and my expand tank is only 6 yrs old and it sounds like it’s good (thumps on pipe side and dings on the air side). My pressure when it’s fully hot and the burners turn off is about 33psi and it’s at about 192 F.

    • @boomer1049
      @boomer1049 7 місяців тому +2

      @@DobraLLC Yes. Mine turned out to be the internal coil leaking. I was kinda disappointed with people on here didn't get too much help. One guy even wanted to shame me for working on my own furnace. It sounds like you may be facing the same problem. I guess I would unscrew the tank just to make sure before blaming the coil. It's mainly 3 things externally, the pressure tank the input regulator or the relief valve. Good luck and let me know what it was. It's how we learn. 😊

    • @DobraLLC
      @DobraLLC 7 місяців тому +1

      @@boomer1049 I believe I found the problem. I replaced the expansion tank a few yrs ago and upon reading the directions I guess I thought the pressure was supposed to be equal to the house water pressure and I had it pumped up. After watching a few videos of people installing the tank, one guy said to leave it at the precharge of 12psi. I figured it was probably supposed to be equal to the reducing valve pressure (12psi), so I let some air out. I got the boiler down to about 25psi at its hottest when the burner turns off. It’s not leaking and I feel much better about it.
      Thanks for your reply.

    • @boomer1049
      @boomer1049 7 місяців тому

      @@DobraLLC Yes I checked my old and my new tank they were both 12psi. Thanks for letting me know what the problem was! 👍

  • @jbrookes701
    @jbrookes701 2 роки тому +1

    How about a video on how to bleed the air out of a hot water system

    • @pelicant
      @pelicant 2 роки тому

      check out steven lavimoniere, his channel has a bunch of detailed videos.

  • @triumphmanful
    @triumphmanful 2 роки тому +1

    smilin jack, no need to see your mug !