F61 Vaillant ecoTEC Full Training Video

Поділитися
Вставка
  • Опубліковано 20 сер 2024

КОМЕНТАРІ • 46

  • @cmavuso6068
    @cmavuso6068 3 місяці тому +1

    Brilliantly done.

  • @ImHowardMoonsir1
    @ImHowardMoonsir1 Рік тому +1

    I'm nearing the end of my ACS and this video is very hjelpful.

    • @ARBoilers
      @ARBoilers  Рік тому

      Hi Danny check this out.
      The Boiler Repair Library - a fantastic tool for you to increase your technical knowledge in gas and electric boiler repairs - is now only £5.00 one off payment for Lifetime Access!
      That’s Lifetime Access to hundreds of How-To and Overview videos, updated every month.
      If you are currently paying £10.00 per month you can cancel your membership and rejoin for the £5.00 Lifetime Access membership instead.
      Click here to view screenshots of the Boiler Repair Library before you join:
      arboilers.kartra.com/page/BoilerRepairLibrarySpecialOffer

  • @sevesham
    @sevesham 2 роки тому +2

    Excellent training film.

  • @ozwellalford5015
    @ozwellalford5015 9 місяців тому +1

    Very Educational 😊

  • @ARBoilers
    @ARBoilers  4 місяці тому

    Thank you for your comments and can you please subscribe to our channel

  • @iftibashir
    @iftibashir Рік тому

    Does the new replacement PCB need setting up at all?
    I’ve read it could result in a F70 code which means it needs associating with the particular boiler model it’s installed into?

    • @ARBoilers
      @ARBoilers  Рік тому

      99% of the time you don't need to set anything up. Also could you subscribe to our channel

  • @HappyRareGrooveMan
    @HappyRareGrooveMan 4 місяці тому

    Boiler radiators won't go hot I've tried everything it's a valient eco

  • @ARBoilers
    @ARBoilers  4 місяці тому

    How long does the boiler fire for up for in heating mode ?

  • @traleyton8057
    @traleyton8057 7 місяців тому

    For good part did not see the mains cable stuck underneath the mother board.

  • @ARBoilers
    @ARBoilers  7 місяців тому

    Thank you for your comments and can you please subscribe to our channel please

  • @thomashaslam9901
    @thomashaslam9901 Рік тому

    Hi I have a reading of 62 ohms? Does this mean the gas valve needs replacing? Or is it still a PCB issue?

  • @MrMarkT84
    @MrMarkT84 2 роки тому

    Great video :) we have the same problem on our ecoTec pro 28, had f61 in the past but now seems to settle on f62, we can clear the code an resume normal operation but we also see temp fluctuations on the display (actual water temp is fine). Everything points to PCB as you video suggests, but as we don’t know the age of the boiler we are debating just getting a whole new unit (maybe different brand). Would your advice be to invest in a new boiler or just replace PCB? If PCB what’s would be a fair price for parts and instillation?
    Thanks for your video an time :)

    • @ARBoilers
      @ARBoilers  2 роки тому

      We have replaced many pcbs on your type boiler and it should run for many years. We would charge 150 labour plus 187.00 for pcb plus vat. The pcb covered for 12 months. What area are you in?

    • @ImranKhan-hz8jy
      @ImranKhan-hz8jy 10 місяців тому

      Do we not have to put any code into after replacment??

  • @pooroldpedro
    @pooroldpedro 4 місяці тому

    careful when two wires the same colour - label with a bit of tape before you take a photo

  • @StuHNomadBiker
    @StuHNomadBiker Рік тому

    He said it was the gas valve cos that what it says in the book .. lol... see so many lads do it, can't always trust the book.... experienced lads know that there are other reasons many times that throw out the same fault... its all about learning and experience.

    • @ARBoilers
      @ARBoilers  Рік тому

      Thank you for your comments and can you please subscribe to our channel 😊

  • @infiniteloopslawson5301
    @infiniteloopslawson5301 2 роки тому +1

    I just kept my finger on the reset button for few seconds and code went away and works fine now.???

    • @ARBoilers
      @ARBoilers  2 роки тому +1

      Ok that's great 👍

    • @infiniteloopslawson5301
      @infiniteloopslawson5301 2 роки тому

      @@ARBoilers it's done it before could it be a faulty sensor?

    • @ARBoilers
      @ARBoilers  2 роки тому +1

      @@infiniteloopslawson5301 it's normally a gas valve or PCB fault

    • @okafka5446
      @okafka5446 2 роки тому

      @@ARBoilers Got exactly the same problem (F61, with temperature jumping around when you reset) thanks for your clear video. Been told it's either the PCB OR a faulty gas valve, and that these boilers (we have the Vaillant ecoTEC plus 837 now 12 years old) have built in obsolescence, so we might as well replace the whole boiler. Not sure if this isn't upselling, but out of interest, once the pcb is replaced is the boiler good to go for a couple more years as long as regularly serviced?

    • @ARBoilers
      @ARBoilers  2 роки тому

      @@okafka5446 100% yeah

  • @waynehardiman5443
    @waynehardiman5443 Рік тому

    So you make sure the knobs hot water and heating are on full a on the pcb ?

    • @ARBoilers
      @ARBoilers  Рік тому

      Yeah 👍 Also can you subscribe to our channel 🙏

  • @sukisingh7268
    @sukisingh7268 Рік тому

    Gr8

  • @nanjones6947
    @nanjones6947 Рік тому

    What about the pressure?

  • @reghy2008
    @reghy2008 Рік тому

    How to measure inlet working pressure at appliance in this boiler? Is it by taking the side panel out???

    • @ARBoilers
      @ARBoilers  Рік тому

      No you need a small ratchet tool to get in gas valve inlet test point and you will need to remove the air pipe

    • @ARBoilers
      @ARBoilers  Рік тому

      Also check out this out
      www.onlineboilerrepairtraining.co.uk/

  • @sukisingh7268
    @sukisingh7268 Рік тому

    Mate i have same issue f.61 code but, its intermittent, i powered off and reignited boiler and it works fine but i may get this code again after couple of weeks so what is the issue?

    • @ARBoilers
      @ARBoilers  Рік тому +1

      It's normally the pcb or it could the gas value. Also could you subscribe to our channel 😊

    • @sukisingh7268
      @sukisingh7268 Рік тому

      Bur what if it continually works fine for months on end as it has so far by just pressing reset button?

    • @ARBoilers
      @ARBoilers  Рік тому

      @@sukisingh7268 just run with it and see how it goes

    • @sukisingh7268
      @sukisingh7268 Рік тому

      @@ARBoilers its getting worse esp. Night time it cuts out we keep resetting

    • @StuHNomadBiker
      @StuHNomadBiker Рік тому +1

      ​@@sukisingh7268 Get an engineer out to it !! Stop fishing for free advice so you can try and fix it yourself ... pay for somebody who knows what they're doing ..

  • @sukisingh7268
    @sukisingh7268 Рік тому

    F61, constant cutting out

    • @ARBoilers
      @ARBoilers  Рік тому

      Possible gas valve or PCB

    • @ARBoilers
      @ARBoilers  Рік тому

      Also could you subscribe to our channel 😊