Vaillant Boiler Service - Plumber

Поділитися
Вставка
  • Опубліковано 30 січ 2025

КОМЕНТАРІ • 125

  • @AllenHart999
    @AllenHart999  4 роки тому +5

    Candlelighters www.justgiving.com/fundraising/cchleeds
    WhatsApp 07725 692699

    • @jalalzaia.4121
      @jalalzaia.4121 3 роки тому

      Thank you very much Allen, I have learned more from you then my gas safe course, may you give a tip how prepare my self for a job interview? I’m recently qualified.

  • @justinjames1558
    @justinjames1558 11 місяців тому +1

    Appreciate this video is 3 years old but you have just helped me out massively, thanks very much.

  • @AllenHart999
    @AllenHart999  4 роки тому +7

    Thank you for all the comments. It’s really interesting to see different peoples opinions. It’s also great to see so many Gas Engineers and Plumbers getting involved and answering questions. Thank you all so much for that.

  • @rayc1503
    @rayc1503 4 роки тому +1

    I put an x with a sharpie on the bracket for the black air intake tube. Carry a small garden sprayer to clean out that heat exchanger and spray it with white wine vinegar. Ceramic grease works well below the threads on the combustion door and G10 seals are standard stock on my van. Great work there guys, always enjoying learning something new 🤗. Hope you have a excellent Christmas and great 2021 👍🏼

  • @bennethos
    @bennethos Місяць тому +1

    Very instructive

  • @BriaCroTex
    @BriaCroTex 4 роки тому +4

    Nice job, not many people will decide put extra money for new seal and checking heat exchanger. As a Vaillant technician for us this is must do when u are opening heat exchanger and i saw few videos where u are just checking if seal looks good and out it back in which is not smartest thing to do, especially on Viessmann where u have silicon one

    • @AllenHart999
      @AllenHart999  4 роки тому +2

      Hopefully these videos will make more and more people service the boilers correctly. If you get the chance please send me some videos in. Thanks.

    • @BriaCroTex
      @BriaCroTex 4 роки тому +3

      @@AllenHart999 i am taking pictures all the time so we can send them with Invoice. And videos when something is wrong so they can get clearer picture of what's happening.

    • @AllenHart999
      @AllenHart999  4 роки тому +2

      @@BriaCroTex If you have any pictures or videos you would be happy to share, Please send them on whatsapp 07725 692699 Thanks

  • @robertmoughtin6421
    @robertmoughtin6421 4 роки тому +8

    Iv cleaned a heat exchanger before with a soft brush it caused a pinhole leak the debris that builds on the heat exchanger is not just surface it’s also corroding in to the heat exchanger also have be called out to combi boilers losing pressure can be difficult to find at first as it looks like the are no leaks inside the boiler as the burner is drying up the water

    • @AllenHart999
      @AllenHart999  4 роки тому +1

      We all do things in different ways and I would always advise you to check with the boiler manufacturer. Thanks so much for the comment.

  • @julianhawker7672
    @julianhawker7672 4 роки тому +5

    Nice video Elliot, I like the water bottle. One thing too note though............ Like you I used to clean the Vaillant electrodes with something very abrasive, a couple of years ago as part of regular updating, I took myself off to Vaillant training, where I was told by the head trainer that you should NEVER use anything abrasive as it kills the special coating that they apply to make electrodes last longer. HTH

    • @BriaCroTex
      @BriaCroTex 4 роки тому +2

      First time hearing this, ignition electrodes are not the problem, flame detection ionisation electrode that's really important to clean, some boilers like Vaillant combine spark and ionisation electrode into 1 electrode so they have to be cleaned basically they have to be shiny after service. I don't want to tell u wrong information but i never heard about that special coat, electrode is basically piece of iron which conduct current.

    • @julianhawker7672
      @julianhawker7672 4 роки тому +1

      @@BriaCroTex Was news to me also...... Check with Vaillant Technical, as their chief trainer told us, I just use a nylon cleaning pad now. ;-)

    • @BriaCroTex
      @BriaCroTex 4 роки тому +2

      I was working for Vaillant 3y as apprentice and 4y as boiler technician. No one ever mentioned this ever.

    • @julianhawker7672
      @julianhawker7672 4 роки тому +1

      @@BriaCroTex I've been at it nearly 40 yrs and was news to me. Doug Mullinger chief man for boilers at Vaillant training Ctr, Bristol told the whole course this during a Q&A , so presume it's correct.

    • @rayc1503
      @rayc1503 4 роки тому

      Correct a few of the Mi's mention not to clean with anything abrasive I.e Viessman and baxi. Nylon brush should be ok imho. Problem with flame rectification electrodes is they rely on ionization to send current back to the board. With calcium deposits covering them they work ineffciantly. So they need a good clean right.

  • @steve45678
    @steve45678 4 роки тому +4

    Merry Xmas to you and your family. Really enjoy watching your channel

  • @user-te1le7ck6b
    @user-te1le7ck6b 4 роки тому

    Alan we really need to start a campaign as there’s no standard law that forces engineers to follow a protocol , I cancelled mine with a landlord company as they just don’t pull heat exchanger etc I’ll be booking a proper engineer for mine from here on.

  • @ek6868
    @ek6868 4 роки тому +3

    Good video big tanx to you and Elliot 👍

  • @fredjennings9268
    @fredjennings9268 4 роки тому +1

    Another informative vid, cracking, thanks guys.👏👍🔧🎄

  • @SalimKhan-gk1fh
    @SalimKhan-gk1fh 4 роки тому +10

    Nearly every time I have forgotten to put the bracket on for the snorkel ! Even though it’s right in front of me!
    Save an old toilet cleaner ‘duck’ bottle it’s brilliant for flushing out the Heat exchanger

  • @iheggis86
    @iheggis86 4 роки тому +4

    DIYer “Now I can service my Vaillant boiler *rolls up sleeves*💪 ... 🤣🤣🤣

    • @AllenHart999
      @AllenHart999  4 роки тому +3

      DIY need to stay away from gas boilers. Thanks for watching.

  • @michaelstott734
    @michaelstott734 4 роки тому +1

    You look smartAllen!

  • @luisangelrevillavallecillo7166

    Muy interesante tu vídeo me dedico al mantenimiento de calderas. Donde puedo comprar el cepillo que utilizas para la limpieza? Un saludo desde 🇪🇦

  • @ryanjones5224
    @ryanjones5224 4 роки тому +1

    Love the videos! Great tips

    • @AllenHart999
      @AllenHart999  4 роки тому +1

      Glad you like them!

    • @AllenHart999
      @AllenHart999  4 роки тому +1

      Thanks very much for your comment, please consider subscribing to support the channel 🙂

    • @ryanjones5224
      @ryanjones5224 4 роки тому

      @@AllenHart999 already have been for a while sir👍🏻

  • @CatholicAventures
    @CatholicAventures 4 роки тому +1

    Allan a good video might be a review of the flueshoe. Cheers for the videos

    • @AllenHart999
      @AllenHart999  4 роки тому +2

      Do you mean you are going to send me a video in of a review ? Thanks.

    • @CatholicAventures
      @CatholicAventures 4 роки тому +2

      @@AllenHart999 if I can get one soon I will bud but if I can't purchase it just yet I highly recommend you try it out when you can for everyone

    • @rayc1503
      @rayc1503 4 роки тому +1

      @@CatholicAventures Don't bother pal, it's a waste of money. I brought it and it was a bit of a fad. It sat in the garage for ages. I sold it to another engineer on gaschat. It really is much quicker to cut flues with a multi purpose blade on a cordless angle grinder. The flueshoe's big and bulky and it ends up being lobbed around in the back of the van.

  • @sydsyd
    @sydsyd 4 роки тому +1

    Excellent video!

  • @PaulDanciu
    @PaulDanciu Рік тому +1

    Do you have any video with pump maintenance and repair?

    • @AllenHart999
      @AllenHart999  Рік тому +2

      Thanks very much for your comment, please consider subscribing to support the channel 🙂

    • @PaulDanciu
      @PaulDanciu Рік тому

      @@AllenHart999 done

  • @indiawest2025
    @indiawest2025 4 роки тому

    Amazing example! how different ways of servicing a condensing boiler..Is this vaillant concealing a multi pass heatexchanger or singel pass? seam like it lasted longer than its sale-dy-date.

  • @smalik695
    @smalik695 4 роки тому +2

    I hope you will show how to replace seal of heat exchanger

    • @AllenHart999
      @AllenHart999  4 роки тому +1

      Might be more here for you ua-cam.com/video/hscFcrn4Edo/v-deo.html

    • @AllenHart999
      @AllenHart999  4 роки тому +1

      Also this one ua-cam.com/video/2ko_JR-BthE/v-deo.html

  • @mariaordona1268
    @mariaordona1268 3 роки тому

    all annual service should be now be included with video report as well, to make sure all necessary service is done as it should be all considering the state of the boiler at the time.

  • @neilrutter
    @neilrutter 3 роки тому

    This a a fantastic video if anyone ( not a boiler engineer ) wants to know what is included in a boiler service. Is this the normal standard of service or do I need to get Elliot.

  • @smalik695
    @smalik695 4 роки тому +1

    Very nice 👍🏼

  • @boilers24-7
    @boilers24-7 4 роки тому +1

    Great video 👍🏽👍🏽👍🏽

  • @mazambeliqbal3487
    @mazambeliqbal3487 3 роки тому

    Hi we brought our vaillant ecoTECpro28 boiler in 2013 and it's been 8 years and I just want to say when the time do you have to service it ?

  • @steve1962
    @steve1962 Рік тому

    I have an issue with my ecotec 615plus boiler annually serviced and we have a contract through British Gas for call outs - vibrating noise when the heating comes on - gas valve and diverter valve have been replaced through the contract and the engineer said it that doesn't solve it, it can't be the boiler, and I've replaced the water tank ballcock and valve. Have been told that the fan speed needs adjusting but don't know how to do it - it's somewhere in the settings - any thoughts? Thanks

  • @jackhoskins722
    @jackhoskins722 4 роки тому +2

    Where do you get that heat exchanger brush please that looks like it will save a lot of time I use the vokera scraper o type one

    • @AllenHart999
      @AllenHart999  4 роки тому +1

      i will try and get a link. Thanks.

    • @jackhoskins722
      @jackhoskins722 4 роки тому +1

      Cheers Alan also where can I donate money to didn’t see it in description.

    • @AllenHart999
      @AllenHart999  4 роки тому

      @@jackhoskins722 www.justgiving.com/fundraising/cchleeds

    • @AllenHart999
      @AllenHart999  4 роки тому

      @@jackhoskins722 Thank You

    • @stevenwhyte4217
      @stevenwhyte4217 4 роки тому +1

      Toolstation do it, about a fiver

  • @andyfadian
    @andyfadian 4 роки тому

    Great video, thanks

  • @easternise
    @easternise 3 роки тому

    Allen. Please let me know your thoughts. Would really appreciate it. Which would you recommend, vaillant ecofit pure 830 vs Worcester 4000.

  • @bobbydogra8148
    @bobbydogra8148 2 роки тому

    Hi Allen,
    Do I need to drain the system before service the boiler.

  • @mohammedmudasar4982
    @mohammedmudasar4982 4 роки тому +1

    Hi mate any idea abut find out water leak heating side? Any equipment?

  • @darrenbastin1601
    @darrenbastin1601 3 роки тому

    Where do you get the wheel brushes from? Is it a dedicated heating engineer site? It looks like a nylon brush out if screwfix

  • @neo_265
    @neo_265 4 роки тому

    Hi Allen, thanks for all the great videos. I've got a Baxi Platinum Combi and out of curiosity, is it normal for the rear combustion chamber insulation to glow? It tells me part of the flame is hitting it.

  • @jugbirsingh6999
    @jugbirsingh6999 4 роки тому +1

    Thanks bro

  • @hamaadrana6191
    @hamaadrana6191 Рік тому

    Get the pro dec silicone carbide roll 5m for £6.50 can’t beat it cheaper than steel wool and 120 grit

  • @jonesypaddlearounddevon
    @jonesypaddlearounddevon 2 роки тому

    My British Gas engineer didn’t do this now for 4 years running

  • @AbdulShakoor-ri7rp
    @AbdulShakoor-ri7rp 4 роки тому +1

    My valiant combination boiler loses all the water in the system after my central heating is turned off I have to fill it up to 1.5 bars to get hot water. Any idea as to what it could be and the cost please thank you .abby

    • @AllenHart999
      @AllenHart999  4 роки тому +2

      When was the last time you had it serviced? Did they pump the expansion vessel up? Thanks.

    • @BriaCroTex
      @BriaCroTex 4 роки тому +2

      Check safety valve see if it's leaking, check expansion vessel pressure, check around radiators if u can find any drips or anything wet. If all that is good and u are still loosing pressure solution is Tec 7 leak sealer.

    • @BriaCroTex
      @BriaCroTex 4 роки тому +2

      Worst case scenario main heat exchanger could be leaking i have seen that few times best way to check that unplug condens bottle and see if water is still coming out of the heat exchanger.

    • @AbdulShakoor-ri7rp
      @AbdulShakoor-ri7rp 4 роки тому

      It was fitted brand new about 5 years ago there is no leak anywhere around the radiators the boiler runs fine on hot water only don’t need to top up at all.it’s only when we use central heating while the central heating is on everything is fine it’s when the heating is turned off that’s when all the water in the system is empty’s and I have to refill the boiler to 1.5 bars. There is no visible leaks that I can see it maybe the water is being released through the safety valve outside in the gutter. Just to repeat the water is completely empty only when central heating is turned off.refill the boiler to 1.5 and it will stay at 1.5bars for as long as the central heating is not used that could be six months. Hope this will give more ideas as to what could the problem be thanks for getting back to me so quickly the first time

    • @BriaCroTex
      @BriaCroTex 4 роки тому

      U can check pressure when heating is ON i
      And all radiators are nice and hot if pressure is close to 3 that means expansion vessel is empty or low pressure. It's really hard to fix the boiler without seeing it. Sometimes a single noise or little detail can tell u everything best thing would be contact Vaillant and do proper boiler service and if after service u still have issue with pressure then u have leak probably in the wall or floor compression fitting is pretty bad or shark bite is leaking when pressure is increased. U need proper central heating engineer, not a plumber a proper heat engineer,which is really hard to find. Call Alan

  • @ianmuirhead5643
    @ianmuirhead5643 3 роки тому

    Can anyone advise where I can get the O ring for the Vaillant eco 28 condenser trap , Vaillant want to supply the complete housing , I only need the o ring , thanks .

  • @smalik695
    @smalik695 4 роки тому +1

    Did you have water in white bottle pl

    • @AllenHart999
      @AllenHart999  4 роки тому

      I believe he said water but i am sure he will correct me if i am wrong. Thanks.

  • @gaslink6785
    @gaslink6785 4 роки тому +1

    Where's that water bottle with the bent tip from?

    • @AllenHart999
      @AllenHart999  4 роки тому

      I will try and find out. Thanks.

    • @gaslink6785
      @gaslink6785 4 роки тому

      @@AllenHart999 ok let us know when you do, could do with one like that

    • @charlie12358
      @charlie12358 4 роки тому +1

      @@gaslink6785 Typed 'squirt bottle' into ebay and about 100 of them came up

  • @mattmackenzie1111
    @mattmackenzie1111 4 роки тому +2

    The condition of the sound deadening worries me could so easily be drawn in air intake, surely its no longer sealing boiler case.

    • @paulmartin1095
      @paulmartin1095 4 роки тому

      according to Vaillant, the sides are sound deadening only, the front door is a com seal

  • @hakksovutcu7507
    @hakksovutcu7507 4 роки тому +2

    Merhaba paylaşımlarınız çok güzel türkiyede çok takibiniz var lütfen Türkçe çeviri rica ediyoruz ✋

    • @AllenHart999
      @AllenHart999  4 роки тому +1

      İzlediğiniz için çok teşekkür ederim. Lütfen beğen ve paylaş.

    • @user-te1le7ck6b
      @user-te1le7ck6b 4 роки тому

      Vaillant tukiyede cok kucuk bir pazar usta 👍 bizimkiler hep demir dokum

  • @cliveramsbotty6077
    @cliveramsbotty6077 4 роки тому

    i don't want to know what else it is that eliot does with that squirty bottle

  • @reusinkinstallatietechniek6256
    @reusinkinstallatietechniek6256 4 роки тому +1

    Hello this is Mike from Amsterdam Holland him a registered Gas ingerieer I didn't see him change the balls for the burner tube and the isolation played why

  • @figogaati1064
    @figogaati1064 4 роки тому +2

    Hi Allen.
    Do you run any training courses for anyone wanting go into plumbing ?
    Thanks
    Marcus

    • @AllenHart999
      @AllenHart999  4 роки тому +2

      Yes i am working with Viva Training Academy ua-cam.com/video/wCHJdewZPtA/v-deo.html

  • @enochpowelghost
    @enochpowelghost 4 роки тому +4

    Horrified at the use of abrasive drill attachment on very thin stainless steel., then they wonder why you have leak in exchanger later on.

    • @AllenHart999
      @AllenHart999  4 роки тому +1

      Thanks for the comment. What would you use to clean the heat exchanger? Thanks.

    • @effervescence5664
      @effervescence5664 4 роки тому +3

      Strange, that's how many of us are told/shown to do it by the manufacturer. It's a stiff brush, not abrasive btw.

    • @AllenHart999
      @AllenHart999  4 роки тому

      @@effervescence5664 We all do things in different ways and I would always advise you to check with the boiler manufacturer. Thanks so much for the comment.

    • @effervescence5664
      @effervescence5664 4 роки тому +1

      @@AllenHart999 Yes we all do, but if you go to the Vailant training day that's one of the methods they show. Viessmann also had it on their course way back when as well.

    • @kevincranfield5235
      @kevincranfield5235 4 роки тому +2

      I too would highly recommend that you stop using that kind of method to clean the heat exchanger, as infact you are removing the heat treated coating and are excelerating the intergranular corrosion to occur on the heat exchanger, use a very soft brush with the water from the condensate trap or white wine vinegar, that it. 👍

  • @veronicahart450
    @veronicahart450 4 роки тому +1

    👍👍👍👍👍

  • @billybobhouse9559
    @billybobhouse9559 4 роки тому +1

    Would this be considered as a standard service at let's say the usual price or would you do this maybe every few years or so and charge slightly extra for the service? I'm interested in how to fairly charge for jobs like this which obviously take more time time to do.

  • @reusinkinstallatietechniek6256
    @reusinkinstallatietechniek6256 4 роки тому

    I mean I did not Changed The Isolation plate and new bolds fore The burner Tube

  • @Ali-co3xp
    @Ali-co3xp 3 роки тому +1

    Watched

  • @farscapeapes
    @farscapeapes 3 роки тому +1

    Vaillant Boiler i have has been serviced the lat 8 years , never seen any of this done, how do fuck can you trust these days

  • @wolfgangmueller1529
    @wolfgangmueller1529 10 місяців тому

    Übersetzung in Deutsch bitte, danke.👍🙋

  • @frenchfrench4514
    @frenchfrench4514 4 роки тому +3

    You really shouldn't clean the main heat exchanger like that, the MIs state that it needs a light clean. ("MIs Remove any loose deposits from the heating spirals
    (3) using a soft brush and jet of water")
    Cleaning it like this is essentially taking off a very small layer of the metal, as soon as you see shiny metal it means that you have taken off a layer. If you do that on every service you're going to half the life of your heat exchanger and its going to pin hole. Its common sense really.
    Just lightly clean it and get any major debri off it, you think you're doing good scrubbing it but you're not.

  • @domiensoors9492
    @domiensoors9492 4 роки тому

    You need to do the grease on the screw thread not there greetings engie technician .

  • @SuperWayneyb
    @SuperWayneyb 4 роки тому

    👍🤓👍

  • @bashirzaman3737
    @bashirzaman3737 4 роки тому

    HOW MUCH..BOILER SERVICE

  • @hawhay2745
    @hawhay2745 2 роки тому +1

    G10 Should be replaced each time the burner is removed.

  • @yoya4766
    @yoya4766 3 роки тому

    It's mostly those who fail at school who go on to these jobs. They mostly do a bad job, and are paid alot of money. This makes them arrogant and even shoddier. Sorry if this is not a popular comment among engineers but if anyone was honest that's the public perception.

  • @alcazarfreddy
    @alcazarfreddy Рік тому

    great video man! how often do you need to service one of these heaters?