CONCEALED BEAM எப்படி தவறாக பயன்படுத்தப்படுகிறது?

Поділитися
Вставка
  • Опубліковано 3 тра 2019
  • CONCEALED BEAM எப்படி தவறாக பயன்படுத்தப்படுகிறது?
    தமிழகத்தில் எங்கும் வீடு கட்ட அழைக்கவும்
    HONEY BUILDERS - ER. M. செந்தில்குமார் - 9940650400
    Office at:
    D3, Third Floor, AA Asirvad Apartment,
    SBO Colony, Cantonment,
    Trichy 620001
    honeybuilders.in
    senthil@honeybuilders.in
    #HoneyBuilders
    #HoneySenthil
    #ConcealedBeam

КОМЕНТАРІ • 115

  • @TamilTestDrive
    @TamilTestDrive 5 років тому +6

    Sir thanks for your reply on my question. This is very important video.

  • @rajavarmancv9600
    @rajavarmancv9600 5 років тому +1

    Very intresting, eventhough i am not belong to this proffession. Your speech shows your passion towards your proffession. And also your dedication towards it

  • @MS-wq8kr
    @MS-wq8kr 5 років тому +2

    Sir your explanation are too good...... i am waiting regularly....As well as i am applying your advice into my new constructing building by the builder.very thank you to....Bcz earlier you gave the suggestion about with out beam slab method.

  • @lenins9552
    @lenins9552 3 роки тому +4

    Sir enaku oru dout hall size 20'×16' ...athula centre concealer beam podalamaa

  • @AnandRaj-qe7jm
    @AnandRaj-qe7jm 4 місяці тому

    Sir neenga soldradhu nalla eruku... But diagram kamichi Sona inum nalla puriyum

  • @arisvijayponraj808
    @arisvijayponraj808 5 років тому +1

    Hello Sir,, in case u posted this video before four months.. It will useful for me... Bcoz we do that same mistake in concealed beam in roof top....but not in proper framed.. We framed in lindel level only..

  • @TheKskarthik76
    @TheKskarthik76 5 років тому

    Hi Sir, I am watching all your videos continuously, all are very useful. Thanks. CAN YOU EXPLAIN ABOUT ROOF TERRACE FILLING, CAN USE COOLING TILES? OR TRADITIONAL METHODS GOOD?

  • @balachandar7779
    @balachandar7779 5 років тому +5

    Sir Ella Intha mestri pandra vela , Avanunga Paatuku kuththu mathipa podranunga,

  • @senthilkumarmj9106
    @senthilkumarmj9106 5 років тому +1

    Hi sir,
    Kindly give some inputs about interlocking brick construction..

  • @syedmohamedkasim3990
    @syedmohamedkasim3990 4 роки тому

    Very useful timely info for me, thanks bro

  • @k.saravanaraj3270
    @k.saravanaraj3270 2 роки тому

    Load bearing.
    Hall size 16×14'9
    Roof ku concealed பீம் or open பீம் எது better...?

  • @kelvinraj8743
    @kelvinraj8743 5 років тому

    Hi sir
    Load bearing structure la gaadi edukurathu eantha alavuku defect aagum
    Veara eathum nalla practice eruka ??
    I'm waiting for your reply sir 🙄🙄

  • @hajimohamed7890
    @hajimohamed7890 5 років тому

    Good.infarmation.thank.you.sir

  • @meerasanjeevi5997
    @meerasanjeevi5997 3 роки тому

    கன்சீல்ட்.பீம்.நல்ல.விளக்கம்.நன்றி

  • @shanmugasundaram7068
    @shanmugasundaram7068 5 років тому

    Sir , SOAK PIT pathi sollunga , kitchen waste water and bathroom kulikira thanniya , soak pit la mulumaiyaaka drain panniralama

  • @revathiayyappan3847
    @revathiayyappan3847 3 роки тому

    Useful information thanks

  • @sudharsudharsan9079
    @sudharsudharsan9079 2 роки тому

    Hi Sir,
    i have 20*20 portion. in that all the 4 side i have roof beam(6-20mm(2 crank bar) and 4-12mm), i have splitted the 20*20 portion into 9 equal segments by using 4 concealed beam with (4 -16mm and 4-12mm)(2 East west and 2 North south) then 8mm and 10mm for roof with 5 inch spacing with one way slab. So is it fine to construct the wall anywhere on the roof.?

  • @jeevalavanya1
    @jeevalavanya1 5 років тому

    Sir can you explain how to rectify wrongly constructed columns or tapered columns

  • @thilojagan126
    @thilojagan126 3 роки тому +1

    Thanks for reading our msg sir 🙏

  • @gopinathpsg
    @gopinathpsg 5 років тому

    Thank u for ur video sir

  • @sankarasubramaniansundaraa8615
    @sankarasubramaniansundaraa8615 3 роки тому +1

    For load bearing structure all around beam at roof level is necessary.

  • @jerinashok9905
    @jerinashok9905 3 роки тому

    Good information thank u sir

  • @SaravanaKumar-xc5fz
    @SaravanaKumar-xc5fz 3 роки тому

    Super sir..... congratulations

  • @krish-id9wb
    @krish-id9wb 2 роки тому

    Sir, load bearing structure house ..ipo 1st floor katurom 4 inch wall 2 place la change agi varudhu, adhuku beam edhachu podanuma? Mastery pblm ila load thaangum solranga...pls suggest

  • @jaggpaddy
    @jaggpaddy 5 років тому +2

    Sir, our hall size is 18x16 ft. Lintel beams 8"×8" runs around. Also 8"×8" beam runs around at the roof level (framed structure). Roof slab is 2 way with 4.5" thickness. A concealed beam is made connecting two columns at the mid way of 18ft length of the roof slab. Is this correct? Pls advice.

  • @essakiraja9084
    @essakiraja9084 5 років тому

    Sir,please explain interlock brick construction...

  • @nasreenhaniya1997
    @nasreenhaniya1997 4 роки тому

    Shop ku lintel beam(belt) podanuma? Mastree thevai illa nu solraru bcoz of regular beam below roof. Please clarify sir

  • @syedahamed7377
    @syedahamed7377 5 років тому +1

    Sir interlock brick use pannala.,then use panna earth quake la thanguma

  • @kovaidoors5163
    @kovaidoors5163 3 місяці тому

    Super explanation sir.. worth it...

  • @kuwaitmalik4720
    @kuwaitmalik4720 4 роки тому

    Hi sir in first floor slab if we need to do partition in a room if i want to construct wall in between can we do with out beam is it possible .isit advisable with out beam can we built wall without beam pleade advicecsir thankyou

  • @tamilselvankamalanathan352
    @tamilselvankamalanathan352 3 роки тому

    Minimum and maximum span distance of concealed beam...

  • @azhagappapillaisubramaniya9305
    @azhagappapillaisubramaniya9305 4 роки тому +1

    Respected sir, A building night is 20feet ( ie Ground floor and first floor) in this building plinth beam has provided for a height of 6i inches and continuous window sill level concrete has provided for a height of 4“ In this building ROOF LEVEL BEAM is required THIS IS A FRAMED STRUCTURE BUILDING Pl clarify the doubt sir
    Azhagappan. Chenna

  • @mathavanv4711
    @mathavanv4711 4 роки тому

    Good evening sir I am mathavan from thiruvannamalai water proofing pathi oru video podunga sir bcz water proof yenna use pannalam yenga use pannanum oru awareness kodunga sir plz thank you

  • @jinujins007
    @jinujins007 5 років тому

    Hi sir I am from kanniyakumari district, I want to know about flyash interlock bricks and where I can buy in tamilnadu or Kerala..

  • @enjoysingloryofthelordtech2914
    @enjoysingloryofthelordtech2914 3 роки тому

    What about Inverted beam sir if u can explain please sir

  • @arjun2698
    @arjun2698 5 років тому

    Sir budget home swimming pool pathi peasuga sir, swimming pool build Panna vaara pros and cons pathi solluga

  • @k.sountharrajan3895
    @k.sountharrajan3895 5 років тому

    hi brother i am from trichy lalgudi dalmiapuram, please brief about GFRG panel house and THERMOCOL house

  • @shanmugasundaram7068
    @shanmugasundaram7068 5 років тому

    Sir , kitchen and bathroom waste watera epdi manage panrathu , PLS PUT VIDEO SIR

  • @gameingtamil8519
    @gameingtamil8519 5 років тому

    super sar

  • @sankargs6499
    @sankargs6499 3 роки тому

    Super sir

  • @harikrishnan2520
    @harikrishnan2520 4 роки тому

    Sir Ground floor slab beam podavillai. First floor slab beam podalama

  • @SelvaKumar-yq9yk
    @SelvaKumar-yq9yk 3 роки тому

    super sir

  • @babug3106
    @babug3106 3 роки тому

    வணக்கம்
    என்னுடைய மனை அளவு 20*60
    தெற்கு பார்த்த வாசல் மற்ற மூன்று
    திசைகளும் வீடு அமைந்துள்ளது
    நான் வெளிச்சம் காற்று நிறைந்த விடு கட்ட ப்ளேரர் பிளன் Floor Plan
    வீடியோ போடுங்க சார்

  • @selvarajm9832
    @selvarajm9832 3 роки тому

    Sir. Concealed beam mela nine inch wall podalama ? Pl reply

  • @aravinthmechanical9013
    @aravinthmechanical9013 3 роки тому

    Sir roof column fulla connect panni concealed beam podalama

  • @manomanoj1035
    @manomanoj1035 3 роки тому

    Super 👍 sir

  • @garivalagan590
    @garivalagan590 4 роки тому

    wat is tarson mate sir ?

  • @aravindlourthusamy5164
    @aravindlourthusamy5164 4 роки тому

    Clear sir

  • @farmandtech
    @farmandtech 2 роки тому

    Sir, nenga sonna madri fully concealed beam slab potrukanga ..... wall la hair cracks vara madri iruku......roof la reinforcement pana vaipu irukungala like adding inverted beam?

    • @HONEYBUILDERS
      @HONEYBUILDERS  2 роки тому +1

      That should be embedded with the slab. Check with a structural engineer for better solutions.

  • @k.sountharrajan3895
    @k.sountharrajan3895 5 років тому

    Its have good future or not?

  • @GUNAMRAJA
    @GUNAMRAJA 2 роки тому

    Sir wall top roof beem centring meserment calculate

  • @kumaran2510
    @kumaran2510 5 років тому +1

    Please Anyone suggest , for 16×16 hall concealed beam is enough. My house was constructed without structural engineer. Please advice. No other side beams were done.

  • @pjai8759
    @pjai8759 5 років тому +1

    Cutout area fulla varum

  • @dhandapanisai1834
    @dhandapanisai1834 Рік тому

    11/17க்கு கன்சீல்ட் பீம்தேவையா சொல்லுங்க சார்

  • @prabhakaweramagi1886
    @prabhakaweramagi1886 5 років тому +1

    Sir I need to interior design video Pl

  • @maheshwaran7176
    @maheshwaran7176 3 роки тому

    sir how to construct the framed structure in without room , some contractor are build in with out roof beam in framed structure ,how is possible and their type of building and also tell about disadvantages of the this type of building pls replay as soon

    • @HONEYBUILDERS
      @HONEYBUILDERS  3 роки тому

      For framed structure, kindly use structural drawings designed by a structural consultant.

  • @3D_Infograph
    @3D_Infograph 4 роки тому +2

    Nice video, I have a doubt, if a 9 inch wall comes between roof, what type of beam is used to take the load.

    • @HONEYBUILDERS
      @HONEYBUILDERS  4 роки тому +2

      concealed beam is not advisable. Either upstand or downstand is recommended

    • @3D_Infograph
      @3D_Infograph 4 роки тому

      HONEY BUILDERS, thank you for quick response.. 😇

  • @eanrumsmk4894
    @eanrumsmk4894 5 років тому

    Sir eanga v2 ipo kattitu irukoom. One side already loadbering la oru suvar irukku, inoru side ipo beam pooturukoom,. Andha beam la irundhu ground level la rendaum connect panni oru beam pootu, addhumeala building katroom. Andha maari seilaamaa

    • @balachandar7779
      @balachandar7779 5 років тому

      Neenga Structural engineer ta Ketu Athuku thaguntha maari beam columns provided panunga

  • @vishalakshijayankondan4164
    @vishalakshijayankondan4164 2 роки тому

    Sir cantilever beam na ena sir

  • @harikrishnan2520
    @harikrishnan2520 4 роки тому

    Pls sir i need ur advice

  • @rolandpromotersbuilders2975
    @rolandpromotersbuilders2975 3 роки тому

    🤗🤗🤗

  • @mk.maiappan1608
    @mk.maiappan1608 Рік тому

    🙏👌🙏

  • @gnanaprakash7013
    @gnanaprakash7013 3 роки тому +1

    Sir hall size 20*20, 2 consulting beam potto 2 way slab potalama

  • @Naanum-Maanavan-Bala-tnpsc
    @Naanum-Maanavan-Bala-tnpsc 3 роки тому

    Load bearing structure roofla concealed beam use pannalama sir???

  • @3D_Infograph
    @3D_Infograph 4 роки тому

    Can we build a 4inch wall on 16*16 room crank reinforcement roof slab without concealed beam?

  • @kuppusamyn8149
    @kuppusamyn8149 3 роки тому

    சார் நான் பல முறை கேட்டிருக்கேன் அண்டர்கிரவுண்ட் கார் பார்க்கிங் பற்றி வீடியோ கேட்டேன் இன்னும் போடவில்லை

  • @sugithpersonalizedphotosan6214
    @sugithpersonalizedphotosan6214 2 роки тому

    Hello sir
    We have completed roof concrete and after howmany days we can start brick works

  • @yoganathanbalachandran9663
    @yoganathanbalachandran9663 5 років тому

    Nice explanation!! As usual in your style. Thanks for it !!👍

  • @srmbuild-tech142
    @srmbuild-tech142 4 роки тому

    sir Concealed beam I have seen in my friend house the contractor give the Concealed beam in living area to avoid the visible of beam which the connect the two columns in centra of the living area he use Concealed beam for (roof top beam) its right r wrong sir

    • @HONEYBUILDERS
      @HONEYBUILDERS  4 роки тому

      It is fine. It should be suggested by the structural engineer.

    • @srmbuild-tech142
      @srmbuild-tech142 4 роки тому

      Sir but span is more then 17 ft.and please give your opinion sir
      I have and idea sir we can do like a (sunken slab) in living area to avoid the visible of beam

  • @mohanbe58
    @mohanbe58 5 років тому +1

    Which software using for structural design of building?

    • @kelvinraj8743
      @kelvinraj8743 5 років тому

      Mohan Be staad pro

    • @mohanbe58
      @mohanbe58 5 років тому

      @@kelvinraj8743
      Staad pro reinforcement design is shown more steel qty, thats only i ask

  • @gopinathpsg
    @gopinathpsg 5 років тому

    Sir contractor katra veetla roof concrete 1:3:4 than use panranga, but oru video la m20 (1:1.5:3 or 1:2:3) use pannanum nu sonneenga. Appo 1:3:4 podalama?

    • @HONEYBUILDERS
      @HONEYBUILDERS  5 років тому

      not advisable. It wont get you M20 grade

    • @gopinathpsg
      @gopinathpsg 5 років тому

      @@HONEYBUILDERS Sir I understood but contractor(ie maistry not engg. Contractor) r using this mix for client which is less than m15 mix

    • @manimozhiyanmanimozhiyan4630
      @manimozhiyanmanimozhiyan4630 5 років тому +1

      @@gopinathpsg It's not gud. Tell him to do correct mix proportion. Otherwise load can be not suitable for certain places.

    • @gopinathpsg
      @gopinathpsg 5 років тому

      Thank u definitely

  • @krajm3204
    @krajm3204 5 років тому

    மத்திய தமிழகத்தின் காட்டுமான துறையின் செயல்பாட்டு வினையே !,வாழ்க!!

  • @velmurugans8076
    @velmurugans8076 4 роки тому

    டை பீம் என்றால் என்ன? அது அவசியமானதா ?

    • @kannappangopalan8160
      @kannappangopalan8160 4 роки тому

      YES I ALSO HAVE THE SAME DOUBT. ON GOOLE I FOUND THAT IS USED TO REINFORCE 4.5 INCH PARTITION WALL

  • @sjayamurugan9255
    @sjayamurugan9255 Рік тому

    Sir, roof beam evlo size podanum

  • @elangovan.a7211
    @elangovan.a7211 5 років тому

    Rice shop 3000 sq fit give me Questions sir

  • @kumaravelkuppusamy3176
    @kumaravelkuppusamy3176 5 років тому

    டைல்ஸ் தரை கீழ் இறங்குவதை தவிர்க்க என்ன செய்வது

  • @vigneshrajan9953
    @vigneshrajan9953 5 років тому

    Sir...one bigg request sir...Foundation mark panra video with plan paper and pen .paper la detail solli video podunga sir

    • @vigneshrajan9953
      @vigneshrajan9953 5 років тому

      Sir..please sir ...indho oru video unga subscriber kaga

    • @vigneshrajan9953
      @vigneshrajan9953 5 років тому

      paper pen ahla....Oru plan la foundation footing work Epdi mark panradhy nuh detail solli kudunga sir

    • @vigneshrajan9953
      @vigneshrajan9953 5 років тому

      2 years work full concrete work dhan sir,Foundation marking kathukannum nuh romba interest iruku but site la ellarum ego la edhuvum learn panna vida maatukiranga sir...Marking mattum solli kudunga sir...mathabadi site la nalla xperience la dhan irukren

    • @mohanbe58
      @mohanbe58 5 років тому

      @@vigneshrajan9953
      Avar business pandraru, unakku teaching pannala, if u want details go to training centre.
      This is not my answer, Mr.senthil sir answer.

    • @vigneshrajan9953
      @vigneshrajan9953 5 років тому

      @@mohanbe58 Ok sir

  • @donjohn..768
    @donjohn..768 Рік тому

    Conceald beam Indian standard il engu kuruppida pattullathu endru vilakkavum...engineer pondru pathivu podavum ...ithai pondra pathivai thavirkkavum..athu beam kidayaathu athai muthalil purinthu kolla vaendum