How to setup EG4 6000XP Indoor Wallmount battery and conduit box kit off grid system

Поділитися
Вставка
  • Опубліковано 28 січ 2025

КОМЕНТАРІ • 12

  • @MatthewYBarbo
    @MatthewYBarbo Місяць тому

    Beautiful install and wonderful instructions. Love your testing area!

  • @davidmaugrion5442
    @davidmaugrion5442 2 місяці тому +3

    Hi, can you make a video on how to connect to a sub panel?

  • @mikemartin-vt4to
    @mikemartin-vt4to 7 місяців тому +3

    Your content is great man. I’m building a house in a couple months and want to put my own system in. 2 6000 Xp and 3 indoor batteries. Love all the detail. Making me feel more comfortable putting the system in on my own!

    • @tgbatg
      @tgbatg  7 місяців тому

      Go for it!

  • @jimverh1868
    @jimverh1868 18 днів тому

    In one of you videos I was watching you had this 6000xp the 280ah wall mount battery with extra server rack battery’s hooked up wanted to know how it worked and how you connected them together please and thanks in advance

  • @tjmooney4181
    @tjmooney4181 7 місяців тому +1

    Correct battery to inverter lugs for the newer 6000xp are 2/0 5/16" the 2023 models were 2/0 1/4"
    Also the protocol settings on master battery need to be set for the communications to work correctly. (Turn off battery, all dip switches up, turn on battery button not breaker, hold enter or return button for 5 seconds to enter protocol settings, change can settings to lux, turn off battery button, set dip switch 1 down for master, turn on battery, done )

  • @fullyelectric
    @fullyelectric 7 місяців тому +1

    @TGB are you going to get the 12Kpv ? I’ll like to see the zero export setup ..

  • @CloudWalker33
    @CloudWalker33 5 місяців тому +1

    What's the largest gauge wire you can connect from the load panel?

  • @quickquote1568
    @quickquote1568 5 місяців тому

    High frequency, output transformerless inverters like these offer shorter life expectancies and poorer surge capacities than low frequency, transformer based inverters. And without an output transformer to provide galvanic isolation between this inverter's DC boost stage and its AC output, you can damage your AC appliances or onboard EV charger during a catastrophic failure of this inverter's H-Bridge circuit. So no thanks.

    • @tgbatg
      @tgbatg  5 місяців тому +1

      hopefully it won't become a reality, but only time will tell

    • @jonvanwyk2026
      @jonvanwyk2026 5 місяців тому

      Overgeneralize much?