400 Amps Service

Поділитися
Вставка
  • Опубліковано 7 вер 2024
  • Master Piece 👌🏽
    Mexican 🇲🇽 Power 💪🏽👷🏽‍♂️
    832-207-7158

КОМЕНТАРІ • 69

  • @rukadore
    @rukadore 5 років тому +2

    This video answered a few questions for me regarding the ground and common from the 320 meter base to the disconnect. Thank you for posting!

  • @alonzoacosta4263
    @alonzoacosta4263 2 роки тому +3

    why do you go to the Distribution Blocks instead of going straight to the Lug of the Primary side of the Can?

  • @jscivolette1180
    @jscivolette1180 Рік тому +2

    Why did you bug the leads in the wire way and no go directly into the disconnects?

  • @carlosalvarez-ek9ll
    @carlosalvarez-ek9ll 4 роки тому +3

    I just want to add one quick note. It looks like you are paralleling your main bonding in the gutter and disconnect. Also since your paralleling in the gutter, that equipment grounding ( green wire) going to the meter will have current.

  • @damianduarte5908
    @damianduarte5908 3 роки тому +1

    Damn thats some clean ass work bro. 👍💯

  • @spelunkerd
    @spelunkerd 5 років тому +3

    Grounding and neutral bonding has always been confusing for me, since I always thought bonding of the neutral and ground must to be at only one place. Here the two are tied together at both the meter and also in the gutter under the two identical panels, with conduit bonding bushings tying all panels together, too. No matter, the whole thing is continuous. Other references I found described isolating the frame of the meter (grounded to neutral back to transformer) from the frame of the first panel (neutral and ground bonded together only there). Maybe it depends on the local electrical codes?

    • @oscar27ization
      @oscar27ization 3 роки тому +1

      You can only main bond 1 time at either the meter or main panel

    • @joejoe6949
      @joejoe6949 2 роки тому

      Your right it’s not confusing just because the job look nice it is not right that bounding in the gutter look wrong. The neutral should be in Polaris taps and the ground should only be on the ground bar in the gutter. But in reality everything is mechanically bounded.

    • @thomasmarable6818
      @thomasmarable6818 2 роки тому

      @@joejoe6949 my local inspectors like to see it only in the wireway, its the first point of service and the neutral can be bare all the way to the main after that it has to be insulated.

  • @kontra
    @kontra 2 роки тому +1

    Not enough cowbell!! I need more cowbell!

  • @FINfinFINfinFINfin
    @FINfinFINfinFINfin 3 роки тому

    I wish Senor Vazquez would do instructional "how to" videos. This channel would blow up.

  • @oscar27ization
    @oscar27ization 3 роки тому +3

    I think you ground wire is set up for only 200 amp instead of 400 since you’re paralleling wires. In other words your ground wire should be for 400amps instead of 200

    • @joejoe6949
      @joejoe6949 2 роки тому

      Nice catch minimum 1/0 in parallel

    • @thomasmarable6818
      @thomasmarable6818 2 роки тому

      Thats going to building steel or metal waterline. Only need #6 to ground rods and #4 to ufer and only a single #3 for 400 amp service. In 45 years never had to run parallel grounding on a service.

  • @emilyyang7087
    @emilyyang7087 8 місяців тому +1

    Thanks for the video, very informative! What is the meter socket model you are using? And what about the disconnect box model? Thank you!

  • @LuisGomez-le4vk
    @LuisGomez-le4vk 5 років тому +2

    Lindo trabajo y al amigo de la pregunt de los cables es para evitar user un cable muy grande se hace el calculo y se pueden poner en paralelo

  • @jonathanvazquez5511
    @jonathanvazquez5511 3 роки тому +1

    Super 👌 trabajo saludos desde Zacatecas mx

  • @ALEXCHAVEZ-ix4yo
    @ALEXCHAVEZ-ix4yo 5 років тому +2

    Appreciate u man!

  • @josev6660
    @josev6660 5 років тому +4

    Wouldn't it be less work to just buy the panel with the 2 disconnects built in? Just curious

    • @MrLuismedina25
      @MrLuismedina25 4 роки тому +1

      Jose V. I agree!! It’s way cheaper to buy a combo right ? And 6 hours less🤦🏻‍♀️

  • @MrTico2506
    @MrTico2506 Рік тому

    Azul y negro me hace suponer que es sistema monofasico (singlephase) en Texas es black & Red ( left to Right)

  • @gerardotorres7904
    @gerardotorres7904 Рік тому

    Porque en la gutter box hizo splice los cables? Que no se pueden llegar del la salida del meter a cada panel?

  • @lnlange
    @lnlange 6 років тому +2

    Why did you use two wires out of the leads to connect to the power company hookup?

  • @SteveN-sy4bm
    @SteveN-sy4bm Рік тому +1

    Thanks for the video… Where did you get the ground bus in the trough? 6:16

  • @techtopics5782
    @techtopics5782 2 роки тому +1

    Pause at 1:50... Yikes

  • @Ed-uu9eo
    @Ed-uu9eo 3 роки тому

    1:51 nice going lol

  •  4 роки тому

    Cuales son los colores para trifasica y que tension utilizan y adonde se utliza..gracias

  • @oscar27ization
    @oscar27ization 3 роки тому +1

    I think you had to separate the ground and the neutrals from the trough

    • @thomasmarable6818
      @thomasmarable6818 2 роки тому

      You can leave them there and not have them in the panels or leave in panels, I leave in the trough because its the first accessible point of the service.

  • @contenidouniversal2251
    @contenidouniversal2251 2 роки тому

    I need ine of those disconnects, where can I find one?

  • @jhernan40
    @jhernan40 3 роки тому +1

    Hola Giovanni gracias por tus professionales videos muy limpio tu trabajo me podrias decir el nombre de este meter box que ocupas o como lo puedo encargar gracias

  • @leandrovillalta1285
    @leandrovillalta1285 3 роки тому +1

    Hola como estás? Como se llaman en ingles las cajas que son más pequeñas y a donde van conectados los cables que dejaste en el gutter largo que está abajo ? Y por que solo llevas azul y negro ? Ese disconnect que llevas allí es 400a 3p?

  • @filsoficonerd
    @filsoficonerd 4 роки тому +1

    Hola buen trabajo tengo una pregunta que numero debe ser el cable para el tierra en 320 amp y 400 amp

    • @giovannyvazquez3652
      @giovannyvazquez3652  4 роки тому

      FILOSOFICONERD 1 Muchas gracias 🙏🏽 Debe de ser número 2 para la tierra

    • @oscar27ization
      @oscar27ization 3 роки тому

      Que
      Cable le pusisteis? Para 200 o 400? Creo que sería para 400 ya es el alambrado es paralelo?

  • @leniesparza8616
    @leniesparza8616 6 років тому +1

    hola jovani una pregunta cuantas ground rods necesito en un servicio de 400 amp con 2 disconnects uno De 100 y el otro De 200.?

    • @giovannyvazquez3652
      @giovannyvazquez3652  6 років тому

      leni esparza
      Hola leni esparza nesesitas 2 ground rods

    • @danserrano2251
      @danserrano2251 5 років тому

      Or one 3/4 by 10ft ground rod
      Using #1 THHN for your ground wire

  • @arrowelectricservicetx
    @arrowelectricservicetx 2 роки тому +2

    Your bonding and grounding practices are incorrect.

  • @adanmeza3275
    @adanmeza3275 5 років тому +1

    Whay blue when is 120/240. ?

    • @wizard3z868
      @wizard3z868 3 роки тому

      Didn't have any red or white tape been there myself lol

    • @joejoe6949
      @joejoe6949 2 роки тому

      At least put the blue on B phase.

  • @robc54
    @robc54 Рік тому +1

    annoying music

  • @eurielcarmona4850
    @eurielcarmona4850 4 роки тому

    Yovany ablas español podrias explicar Como se pone una mas panel para una casa

    • @giovannyvazquez3652
      @giovannyvazquez3652  4 роки тому

      Euriel Carmona Si claro en cuanto pueda yo ago un vídeo sobre cómo poner un panel
      En donde Radicas.?

    • @eurielcarmona4850
      @eurielcarmona4850 4 роки тому +1

      @@giovannyvazquez3652 kise decir un main panel para una casa o cambiar la caja vieja x una nueva radico en Washington

    • @eurielcarmona4850
      @eurielcarmona4850 4 роки тому +1

      @@giovannyvazquez3652 gracias x enseñar

    • @giovannyvazquez3652
      @giovannyvazquez3652  4 роки тому +1

      De nada no te preocupes
      Gracias por Observar los vídeos
      De estado a estado los códigos de electricidad cambian pero por lo regular no mucho
      Además cuando haces las cosas bien raramente tienes problemas a la hora de inspección
      Ya tengo vídeos acerca de como cambiar un Main panel de una casa 🏠 pero sin duda puedo hacer otro con más especificación y lujo de detalles para que tengas/n una mejor idea o

    • @eurielcarmona4850
      @eurielcarmona4850 4 роки тому

      @@giovannyvazquez3652 Gracias te lo agradeseria

  • @adanmeza3275
    @adanmeza3275 5 років тому

    Is nat correct

    • @viniciusfranco6027
      @viniciusfranco6027 4 роки тому +2

      You not supposed to use impact screw gun to tide dos log ...you have to use a torque wrench

  • @kristianqaqi2084
    @kristianqaqi2084 6 років тому

    How much does it cost for upgrade 400 amps?

    • @giovannyvazquez3652
      @giovannyvazquez3652  6 років тому

      Kristian Q
      It depends

    • @giovannyvazquez3652
      @giovannyvazquez3652  6 років тому

      Kristian Q
      I have to see the job so I can give you price

    • @rcfleischman750
      @rcfleischman750 6 років тому

      $5000.00

    • @danserrano2251
      @danserrano2251 5 років тому

      $5,000-$5,800

    • @wizard3z868
      @wizard3z868 3 роки тому

      Go to HD or Lowe's less than $1000 and a taco dinner especially if your close to the border lol just don't use the toaster and lights at the same time lmao rofl

  • @terrymitchell7714
    @terrymitchell7714 2 роки тому +1

    The music sucked