How to Charge Refrigerant (Gas) in an AC unit?

Поділитися
Вставка
  • Опубліковано 20 гру 2024

КОМЕНТАРІ • 104

  • @zameenwala754
    @zameenwala754 11 місяців тому +11

    You tell everything about gas charging step by step . Now No question is remain .
    Full guide 👍💡

    • @zebralearnings
      @zebralearnings  11 місяців тому +2

      I am glad. But there are many things about refrigerant charging. I will explain everything in a video.

    • @zameenwala754
      @zameenwala754 11 місяців тому +2

      @@zebralearnings oka sir I will be wait 😊

    • @jollyscaria1922
      @jollyscaria1922 9 місяців тому

      Suchionline contened dis ..chergd lind contactinv yelow chwfgjnv cylinder valvropon cylindef R420 cylimdef up fosn anc cherhrinv ues fighte allthsnkyou gues wdlcome purgdaftef yes testing fixing checkinv znd oneby meghec ok

    • @ravijeeverma876
      @ravijeeverma876 5 місяців тому

      ​@@zebralearningscan I get ur number

  • @Balticblue93
    @Balticblue93 Рік тому +40

    410A needs to have the bottle inverted upside down to charge properly as a liquid. If you charge it upright, it will fractionate the near-azeotropic mixture. R22 is a single component and can be charged as a gas.

    • @gabrielphilips6980
      @gabrielphilips6980 Рік тому +1

      What is 410a? What is r22?

    • @zebralearnings
      @zebralearnings  Рік тому +4

      It's depends on the cylinder. Before charging the refrigerant we should check the instruction on the cylinder how to charge.

    • @zebralearnings
      @zebralearnings  Рік тому +9

      R410A and R22 is two different types of refrigerant (Gas).
      R22 is older type refrigerant and R410A is modern refrigerant.
      R410A is more environmental friendly than the R22 refrigerant.
      Because R22 has chlorine atoms which dangerous to ozone layer but R410A doesn't have any chlorine atoms.
      The modern AC systems are replacing the R22 refrigerant with R410A refrigerant.
      R22 Refrigerant will not be available in the future due to environmental concerns.

    • @DaveMavrik-ki7xb
      @DaveMavrik-ki7xb 9 місяців тому +1

      Does r22 and r32 also need to turn the cylinder upside down too?

    • @Balticblue93
      @Balticblue93 9 місяців тому +1

      @@DaveMavrik-ki7xb R22 and R32 are single refrigerant and their composition does not change. Thus both liquid charging and gas charging is possible. Liquid charging of R32 all at once from the low - pressure side may cause the compressor to malfunction.
      Working pressures for R32 are very similar to R410A and when charging, R32 is easier to handle as it can be charged in both a gas and a liquid state. This why R32 is classified as A2L “mildly flammable” while safety data sheets say it is extremely flammable but it really is very low flammability.

  • @anookgujjala4132
    @anookgujjala4132 9 місяців тому +4

    Nice explanation sir 👍thank you

  • @pranavprasannan0039
    @pranavprasannan0039 4 місяці тому +3

    The low-pressure line is typically used for charging refrigerant gas, whereas the high-pressure line is used for charging refrigerant liquid. Liquid charging generally takes less time compared to gas charging.

  • @elnursafaraliyev6618
    @elnursafaraliyev6618 6 місяців тому +7

    Hi. Why need to connect high pressure line if we are not use that during charge refrigerant?

  • @rajkumar.s1251
    @rajkumar.s1251 21 день тому

    What a man you are very grateful 💓

  • @НуроЗаринХан
    @НуроЗаринХан 6 місяців тому +2

    Thank you for this good animation! 👍🏼

    • @zebralearnings
      @zebralearnings  6 місяців тому +1

      Thank you

    • @Amandeepbawa18227
      @Amandeepbawa18227 5 місяців тому

      Brdr how can we connect valve in high pressure and low pressure units?

  • @ganeshgarai416
    @ganeshgarai416 6 місяців тому +5

    What is the need of connect high pressure guage????

    • @NasimKhan-m3q
      @NasimKhan-m3q 3 місяці тому

      To know High pressure

    • @LuigGz
      @LuigGz 2 місяці тому

      To get readings of sub cooling

  • @4cchansemicircle944
    @4cchansemicircle944 11 місяців тому +3

    ​​This is a very good video. Please my question is I added refrigerant to my 1hp Samsung spit AC when the power was turned off and I waited 10 hours to put the power on. Is it okay?

  • @TheGines1979
    @TheGines1979 9 місяців тому +1

    Can you show other techniques? Please

  • @QuangLe-eg5si
    @QuangLe-eg5si 9 місяців тому +1

    Could you explain to me what happens if we open high-pressure on-off valve when we charge refrigerant ( GAS ) in an AC UNIT ?

    • @zebralearnings
      @zebralearnings  9 місяців тому +3

      If we open the High Pressure On/Off Valve, Refrigerant will start going from AC Unit to Refrigerant Cylinder. Because the pressure in the High Pressure Side of the AC Unit is more than the pressure in the Refrigerant Cylinder.

    • @Adam-eh2pg
      @Adam-eh2pg 23 дні тому

      @@zebralearnings I have always charged a AC system with high and low side

  • @densista1160
    @densista1160 9 місяців тому +1

    can you fill using the red hose to the low pressure side?

    • @zebralearnings
      @zebralearnings  9 місяців тому +2

      No you can't fill through the red hose. Because the red hose in connected the high pressure side. If you try to charge through the red hose. Instead of the refrigerant going into the unit, the refrigerant will return to cylinder from the unit because of the pressure difference.

  • @densista1160
    @densista1160 9 місяців тому +1

    one question, is the red hose to high pressure line, complete shut off all the process?

    • @zebralearnings
      @zebralearnings  9 місяців тому

      Yes, it will be completely shutoff through out the process.

    • @densista1160
      @densista1160 9 місяців тому

      why have it connected then? can't you just have the blue hose connected to fill ?@@zebralearnings

  • @ewomazinoabugo5829
    @ewomazinoabugo5829 5 місяців тому +1

    Please i want to know using my single guage, on the PSI scale, what number should be the jogjest I'll let the gas reach in a 1.5hp inverter AC

  • @tbone6354
    @tbone6354 9 місяців тому +1

    A very helpful tip is to add 50ml of purified water to the compressor before regassing. This reduces corrosion and no need to vacuum

  • @HunterRavin
    @HunterRavin Рік тому +1

    How to know when its time to close the blue vlv after letting air out

    • @zebralearnings
      @zebralearnings  Рік тому +1

      Nice question. You can see that easily when the refrigerant comes out. It will come out like spraying water.

  • @slobodanmilic1331
    @slobodanmilic1331 4 місяці тому

    Pls produce video about electrical connections.

  • @otrovx
    @otrovx 8 місяців тому +1

    Hi, thanks for the video. Is it necessary to attach the red hose to the air conditioner in order to fill it? I have simpler manifold gauge, with only blue and yellow hose (without red hose, and without red gauge).

  • @7starernhernh580
    @7starernhernh580 6 місяців тому

    Very good sir ji....exvelenttt

  • @abgzulkifli
    @abgzulkifli 6 місяців тому +1

    How do we know how much gas need to be refill

    • @zebralearnings
      @zebralearnings  6 місяців тому +1

      We can check that with the pressure gauge.

  • @HeraTaboro
    @HeraTaboro 5 місяців тому

    Please i need more information about Refrigeration and ac

  • @7starernhernh580
    @7starernhernh580 6 місяців тому

    I m instrctor r/ac..but your mathed very Excelent.......

  • @phyowin5288
    @phyowin5288 8 місяців тому +1

    very clear video🎉🎉

  • @82levy5
    @82levy5 5 місяців тому

    How i know that i charged enough gas? What is the right pressure i looking for?

  • @HarunTechnology
    @HarunTechnology 9 місяців тому +1

    Nice video

  • @sahamghaffarinader6149
    @sahamghaffarinader6149 5 місяців тому

    Thanks a lot very usefull ❤

  • @CATechTips
    @CATechTips 4 місяці тому

    How much refrigerant should charge

  • @samisiddique5000
    @samisiddique5000 6 місяців тому

    please tell us before charging gas required vacuum full machine required time and -psi value

  • @lukebarron308
    @lukebarron308 6 місяців тому

    Don’t you usually charge with the jug inverted ? Liquid not vapour

  • @jacobprem26
    @jacobprem26 7 місяців тому

    How much time will it take to transfer gas from cylinder to ac outdoor unit

  • @JerryDPaye
    @JerryDPaye 4 місяці тому

    How to use claim meter to recharge

  • @8m405
    @8m405 6 місяців тому

    Why discharge valve on guage was closed thought-out

  • @babaolowo35
    @babaolowo35 Рік тому +2

    THANK you

  • @babis8566
    @babis8566 2 місяці тому

    This is not discharge line,it is liquid line.Its after the condenser and before the expansion valve.

  • @naeemtahir3406
    @naeemtahir3406 7 місяців тому

    I was charging 410a while charging compressor and fan shut down itself, I checked breaker and thermostat both were on , what could have gone wrong

  • @Marian-RXZ
    @Marian-RXZ 22 дні тому

    Thanks !

  • @tilvalhalla9343
    @tilvalhalla9343 6 місяців тому

    Why does nobody ever show you what you do if you have a recovery cylinder I don’t know whether to hook it through the red or the blue

  • @sabudjed1135
    @sabudjed1135 4 місяці тому

    Very good

  • @Afhvac
    @Afhvac 2 місяці тому

    And unit offff what is prociger

  • @CornelStefan-b9l
    @CornelStefan-b9l 8 днів тому

    Sub presiune manometre control valve

  • @SanayaKhan-x9t
    @SanayaKhan-x9t Рік тому

    Brother it's totally half knowledge about gas charging it's not the way we have to first leakage check and fill leakage than vaccum after all process gas charging 😊😊

    • @zebralearnings
      @zebralearnings  Рік тому +1

      It's just a basic concept of gas charging method. I'll make a detailed process of gas charging video and will upload it.

  • @patakotisrinivas1918
    @patakotisrinivas1918 11 місяців тому +1

    Nice

  • @pradeepkumar-bd1wc
    @pradeepkumar-bd1wc Рік тому +1

    Gas charging ka Hindi me animation

  • @mohammedegyptian2527
    @mohammedegyptian2527 7 місяців тому +1

    bravo

  • @InspiringlyPositive12
    @InspiringlyPositive12 Рік тому +1

    👍👍👍

  • @davewindt1506
    @davewindt1506 9 місяців тому

    Should shut down the unit en perform a vacuum test 24 hours prior charging the system to be sure the system is leak free and all the air is out.

  • @mohammedmuneer2390
    @mohammedmuneer2390 8 місяців тому +1

    In hindi translation plz

    • @zebralearnings
      @zebralearnings  8 місяців тому

      I am making in Hindi also. I will upload soon.

  • @muhammadalifblogs
    @muhammadalifblogs 9 місяців тому +1

    রিদয় নাড়া দেওয়ার মতো একটি নাটক।

  • @nagatejachandaka13
    @nagatejachandaka13 4 місяці тому +1

    My name is teja

  • @mansurshah9015
    @mansurshah9015 6 місяців тому +1

    THis is for Brampton boys not the proper way thanks but no thanks

  • @NestorLaureano
    @NestorLaureano 3 місяці тому

    WRONG NEED SCALE,AFTER VACUUMING R410 OR R32 IN LIQUID STATE BEFORE RUNNING THE SYSTEM WITH EXACT WEIGHT.NOT OLD SYSTEM YOU ARE TUTORING.

  • @JerryDPaye
    @JerryDPaye 4 місяці тому

    Hi

  • @petergombos3012
    @petergombos3012 4 місяці тому +1

    No vacuum pump, no scales, not even a drop of environmental protection. We do not flush with refrigerant!!! The other is that it is not possible to connect to the discharge line. Sorry, but this is how don't do that.

  • @ACTECHNICIANBR09
    @ACTECHNICIANBR09 Рік тому +1

    Hindi video

    • @zebralearnings
      @zebralearnings  Рік тому +1

      main hindi video bana raha hoon aur jald hee upload karoonga.

    • @ujjawalkamboj2965
      @ujjawalkamboj2965 Рік тому +1

      Please continue in english

    • @zebralearnings
      @zebralearnings  Рік тому

      @@ujjawalkamboj2965 Yeah sure, in this channel I will upload only English video. I have opened a separate channel for Hindi. In that channel I will start to upload videos in Hindi.

  • @mechanicalengineeringpract140
    @mechanicalengineeringpract140 Місяць тому

    Very good