All of these videos are so informative and detailed its like being in the classroom. Anybody else here in hvac school watching these to teach themselves?
Same here man started a year ago but ended up getting a different job but going for it again so these are good for reviewing and learning what you lost
Ive been wanting to join this industry for quite some time now. I recently graduated a HVAC/R Technology Diploma Program and due to covid I really didn't get the hands on training needed. So my company has me doing PMs to learn the equipment and finding issues. I hope this is a great way to learn. I've been told so many different things I don't know what to believe. So, With that, I Just ordered the quick reference cards and can't wait to use them. I am 34 and hoping I have a long career in this industry and get the hands on training that I need to be successful.
Kyle, depending on your state, it be might be possible for you to start your own HVAC business by getting your own insurance and getting a license from your state to be an HVAC Contractor. Different states have different requirements so if you really want to do HVAC and not fight the hassle of where you are at, then find a small town with no HVAC company nearby in a small business friendly state and put your knowledge to the test. It’s very freeing and there are plenty of distributors who will give you a dealership as well as online companies that will ship the products you need.
@@axeldread2979 the insurance is what will kill your profits, not saying it’s unnecessary but it is what prevents many from going into business for themselves
36 here and a 14 year plumber and have been doing HVAC for about 9 months now and honestly PM is where it’s at for guys our age, installs aren’t exactly what you want to be getting into unless you’re doing them for yourself, if your employer has a good set up for you to earn some commission then PM can definitely make you some good money if you work for a company that is doing commission for coil cleaning, system cleanings and selling new systems to customers you find with old systems that are shot, also some companies will pay you commission for good reviews on google and stuff like that, if you can find a place like that then you’ll make decent money and not kill yourself and honestly most installers just know how to lay duct work down and make everything look pretty if all they’ve ever done is install while with doing PM you’ll learn the ins and outs, good luck!
@@axeldread2979 I just started the trade myself I'm not really interested in license myself unless it was to do my own installs and make tons of money. Honestly I hate installing though lol I like servicing.
Great video, very instructive and clear. The locking service port caps are interesting. I'm a DIY hack who installed my own system 24 years ago and it's still running strong (knock wood). About 20 odd years ago I had a friend call me on a hot July 4th weekend. He had family over from out of town for the holiday, a house full of people and his A/C failed. He called me and told me he tried to get a repairman but none he could reach would come until after the holiday. So I went over there with my gauges, vacuum pump and a tank of R-22. When I put the gauges on it there was no refrigerant in it at all. So we went along the line set to look for a leak, and there was no evidence of damage to it. So I put the vacuum pump on it and and tested to see if it would hold vacuum and it did. So I ran the vacuum on it for and hour and recharged it with refrigerant. It ran fine and I was the hero of the day. I told him if the charge ran down again he'd need to call somebody to track down the leak, but it never did run down. I checked with him years later and he said the system was still working fine, no complaints. They sold and moved about 10 years after and never had any trouble with the A/C during the remaining time they lived there. The house was in a semi rural area with the condensing unit at the rear of the house, and no chance of random traffic thru the fenced backyard. However there were several kids there between his own and their cousins. The moral of the story is the locking service port caps are a good idea if you have kids.
I like how you cut off the yellow hose filled with liquid refrigerant early and allowed it to finish charging the system. What attention to detail! I love your clarity. You are a true friend! Thank you for all of your hard work!
Vacom and gaz chergd cylder opset puting liquied cherginv scushion pugering snd scushio chegd 120to 130cherge smerchecking systom totadlg checking good wofking no no gas purged good way leck checking fixe
You are a great A/C tech . If there was young apprentice wanting to learn the A/C biz you would be the guy I would want as an instructor ... Kudos to you and your expertise
This was a great video! Helped me out alot...my instructors from Institute of technology HVAC sucked....didn't have the patience to instruct accurately cutting corners is what I see from them. Thank you Sir for the lesson.
Best explanation I’ve seen on the internet with usage of tools,temps gauges and charts ty your a lifesaver! This is a field I’ve been interested in for a very long time. My son is also liking it!
I watched videos from several other 'folks', and read many articles. I have to say, your video is by far the best available, light years ahead of everyone else. You explained not only the how, but the why, in simple terms. If you were living in my area, I'd hire you in a heartbeat!!! I'll subscribe and buy the book to support your site. Keep up the great work!
New subscriber. I went to tech school back in '99 and worked for Sears and a couple of other companies until getting hurt and had to quit. These videos help keep me sharp because everyone knows that if you don't use it you lose it. Thanks so much!!! Well done.
On the older r22 systems I usually went for 8° super heat where most systems preferred 12°. Never had a single complaint. The differential between return and supply Temps were preferably 14-21°. Anything less usually indicated a blocked evaporator coil.
Really enjoyed it. Funny, plan on re educating myself and head back to school. I am retired, but what the heck? Called a tech and I knew more about charging the system than he did. But it cost me $350 due to the fact I am not EPA certified could not purchase the refrigerant. Well, thank you. Liked your teaching method.
For sure one of the best videos I have watched pertaining to filling with the why's and how's. This video has certainly left enough of an impression on me in regards to filling systems. I will admit that I have filled a little too fast in the past based on how low and slow you let the gas in. Thank you for your professionalism and explanation. I look forward to viewing more of your videos in the future.
Here in Utah if the inside heat load isn’t high enough, we will restrict airflow with bags on the outdoor condenser to manually create it. Great video 🤘
I was offered a job to learn hvac and the guy training me just plugs in low pressure gauge and fills it super fast then we're out lol. Usually 2 minutes or less we're out of there. Glad to know the correct way now. I'll remember so I don't look like a moron if I ever start at another company
Very informative video. My mini split is not blowing cool air and I watched some videos and it mislead me. I thought, my system is over charged. After watching your video I understand the whole system how it works. Thank you 🙏
Speak to yourself in Sweden there is probably Max 5% of people that does not do this. The rest of us has a cefirticate and needs to know all this in order to work with refrigirants.
This is a regular standard procedure if your not purging your lines you shouldn’t be doing HVAC/R leave it for the pros seems like a lot of old timers never practiced this method or using a micron gauge in a vacuum
Great video. Very clearly explained.I've serviced lots of cars but never a house. Just had an HVAC company come in yesterday. Guy quoted me $250 per pound to add about two pounds of R22. Insane...with the right license it can be purchased right at $34-36 per pound from Ability Refrigerants. A mark up of even $100 per pound I could accept but not $250. Told him to take a hike.
Excellent video very clear on how to calculate refrigerant based on super heat. You did not mention how big is the unit i mean the capacity on which you worked, if you please mention it on your answers, thank you.
Great training. I wish tech's made better pay, I might become one. Opening my own service company might be worthwhile. Can't have enough HVAC tech's during the summer in Arizona.
Absolutely excellent tutorial. Ordered your quick charts because of how happy I was with your explanations. I do have a question though, what’s the best way to determine if a system is using a fixed or Txv application? Thnx
Look on the manufacturer's plate on the condenser outside. If it says something like "TXV Subcooling 12," then it has a TXV. If you cannot find that stated anywhere on the plate, then you don't have a TXV.
This is great when yur house is at 71 degress and also outside. But I wish youd do this with temps like we have here with 113 outside and 79 inside. Im sure the numbers would be off the charts. we exect to get over 117 in a couple of days. Yes here in the phoenix area.
This is a very interesting scientific method of measuring the system performance and the actual charge required to obtain optimum. But I wonder if simply filling it to the manufacturer's pressure specifications is also close enough for as they say government work?
Refrigerants are charged by weight from the factory. Most manufacturers recommend replacing the refrigerant when a leak occurred on R410A because it's a 50/50 mixed R125 and R32 refrigerant. On a car, it's completely normal to be low in refrigerant after 15-20 years because of the hose but not on a window and split type AC that uses all metal pipes. Low in Refrigerant simply means there is a leak. Very difficult to find a leak on R410A because it only leaks when pressure is very high. That is why the pressure test is done at 500 psi. It's probably leaking on the flare connection because 410A requires wider flare. No wonder why AC techs are so incompetent. They made their own procedure instead of reading the instruction manual.
I had yalls book and gave it to a helper whom it seemed was into it. Never saw that book again smh. May have to buy another n not give it away. Those cards are good for those who get overwhelmed and when you do your memory goes out the window like me. 👍 this channel is the sh*t
I can agree with everything except the part you said about the R-410a being released to the atmosphere cause damage to the ozone as R-410a has a 0 ozone depletion potential.
Please do some hack job videos. For example add moisture on purpose to a working system to show what happens. Add incorrect type of refrigerant to a system to show what happens. More learning from explosions. Thanks for all your valuable info.
Holy shit..my brain hurts.. I've watched 3 times. I'm used to R-22 beer can cold.😂 I just was handed a property of 400+ units all 410 A.. multiple units not cooling.. I'm trying my best and you definitely helped bro ty.. But with that said I'm still lost...
Unfortunately, in S.E. Texas, there are many who are working full-time in the a/c business who are pretty clueless but the a/c supply stores protect them anyway and won't sell to an unlicensed homeowner. If it was 72degrees F and low humidity, I would just open the windows!
Another great video from Craig👍. Is this is a new method of bleeding air out of the manifold hoses?? I recall the first method where after connecting hoses to the valves, you loosen each hose at the manifold end. Is this new method better ??
I actually started bleeding it the way he does a few years ago. To me, it’s the best way to do it. I was taught to bleed them at the manifold. I think that’s the worst way to do it. 1) oily manifold. 2) I always felt there was still air in the manifold that didn’t bleed out. Doing it his way (which he takes a long winded way of explaining) you get all the air out and stop oil from getting all over your gauges.
How I wish you mentioned PSI readings alongside-- against the temperature readings... for my understanding. I kinda relate better that way... I know you said using the temperature readings works better, that super-heat calculation seems to be messing with my head 😂
@@kitty9374 I am pretty sure the cylinders are the same colours. Pink for 410a and green for r22 for example. But I just meant we have dip tubes so you don’t have to invert the cylinder
I been working in a company for almost 2 years and I like this job but the ppl that I work with they don’t really want to teach me or they don’t want me to learn I already know some about this job but I should know more already since been doing it for almost 2 years all they ask me to do is ductwork and run flexes.
Great video . Booked on a course in the uk for this at the end of the month. Just a shame you guys use imperial as I’m trying to discard the measurements in my head whilst trying to remember the other bits . Very well informed though .
I have a new Rheem 3 ton unit, compressor, new line set, furnace, and evaporator coils, all new R8 ducting, and registers were sealed and a new thermostat. My question is when it is 100 degrees outside my new unit will not cool below 77 degrees. My home is 1408 sq. ft. They don't take outside temp with inside temp for a cooling target number what am I missing, just paid 14,000 for install. Hope you can answer they are coming today to check my charge, why should they have not done this from the beginning, beer can cold charge it seems like. Please answer desperate !!!! Also wanted to add my new unit has to run constantly to maintain 77 or 78 degrees !!
Why utilize a Manifold at all? The temperatures of the Suction/Liquid lines, ambient air, indoor air temps, against a manufacturers Charging Chart will give you an accurate charge indication of charge without losing any refrigerant.
I watch this video always telling degrees, what is the unit of measurement is it Celsius Fahrenheit or Kelvin? While charging the system you did not tell the side of compressor current? Your only on the temperature and pressure,, adding refrigerant is adding current. But your video is very useful
Thank you. I’m just a homeowner and was thinking I shouldn’t check my sytem often, perhaps only when I don't think it’s cooling as well as it should AND after I have checked my filters….would all that be correct? How much are you currently charging your customers for refridgerant 410A? Last question, I’m guessing it’s not a good idea to check my system pressures and temps in the winter…what outside temps should I check my system if I suspect it’s not cooling correctly. Thank you again for a very informative video!
i have one query as i come to know that R410 A need to be charged in liquid phase then why we are inserting it to vapour line. It could Damage compressor
Awesome video! Thanks for posting. BTW, your "Refrigerant Charging and Service Procedures for Air Conditioning" book is well worth the price and awesome also!
Question for you. Could you keep the 410 - A bottle upright and get only gas into the system instead of charging with the bottle upside down and getting liquid?
No, apparently 410a is made of two different refrigerants and in the liquid form, they will remain mixed correctly. The gas above can be more of one refrigerant than the other.
I have a question. When you connect the blue and red hose to the compressor there were hexbolts... do you not need to open them? Just wondering if you need to open them or don't touch them. Thanks for great video.
Hi, sir. I like all your videos, and they are very informative. I have a question about refrigerant R410A. If there is a leak on the low side, can we pump down the remaining refrigerant, fix the leak, vacuum the low side, and then top up, or do we need to recover and fill it with new refrigerant?
You can pump it all into the outside condenser unit, close the low side valve, then break the line on the building side, fix it, pump down the building lines, then open the valves and run again. Look for pump- down videos…
So you must add 401a as a liquid? Because it is actually a mix of two different refrigerants that of course have different expansion temperatures, so if you boil off directly from the bottle one of the refrigerants will boil off first causing a concentration of that refrigerant in the released gas/vapor.??? Kind of like a distillation tower.
All of these videos are so informative and detailed its like being in the classroom. Anybody else here in hvac school watching these to teach themselves?
Me
What's is the size of the compressor
Soon to be.
Yes
Yep online school so being able to see something other than pictures is super helpful.
I've been doing hvac for over 40 yrs you doing a great job on your videos.
Great video! Im a 1st yr 2nd semester refrigeration student starting from scratch....this video is priceless....👍🏾 THANK YOU!
Glad it was helpful!
Same here man started a year ago but ended up getting a different job but going for it again so these are good for reviewing and learning what you lost
Ive been wanting to join this industry for quite some time now. I recently graduated a HVAC/R Technology Diploma Program and due to covid I really didn't get the hands on training needed. So my company has me doing PMs to learn the equipment and finding issues. I hope this is a great way to learn. I've been told so many different things I don't know what to believe. So, With that, I Just ordered the quick reference cards and can't wait to use them. I am 34 and hoping I have a long career in this industry and get the hands on training that I need to be successful.
Kyle, depending on your state, it be might be possible for you to start your own HVAC business by getting your own insurance and getting a license from your state to be an HVAC Contractor. Different states have different requirements so if you really want to do HVAC and not fight the hassle of where you are at, then find a small town with no HVAC company nearby in a small business friendly state and put your knowledge to the test. It’s very freeing and there are plenty of distributors who will give you a dealership as well as online companies that will ship the products you need.
@@axeldread2979 the insurance is what will kill your profits, not saying it’s unnecessary but it is what prevents many from going into business for themselves
36 here and a 14 year plumber and have been doing HVAC for about 9 months now and honestly PM is where it’s at for guys our age, installs aren’t exactly what you want to be getting into unless you’re doing them for yourself, if your employer has a good set up for you to earn some commission then PM can definitely make you some good money if you work for a company that is doing commission for coil cleaning, system cleanings and selling new systems to customers you find with old systems that are shot, also some companies will pay you commission for good reviews on google and stuff like that, if you can find a place like that then you’ll make decent money and not kill yourself and honestly most installers just know how to lay duct work down and make everything look pretty if all they’ve ever done is install while with doing PM you’ll learn the ins and outs, good luck!
@@FalloutGenius1 the insurance isn’t that bad for a small HVAC company. It’s also a must if you want to be licensed in most states.
@@axeldread2979 I just started the trade myself I'm not really interested in license myself unless it was to do my own installs and make tons of money. Honestly I hate installing though lol I like servicing.
Great video, very instructive and clear. The locking service port caps are interesting. I'm a DIY hack who installed my own system 24 years ago and it's still running strong (knock wood). About 20 odd years ago I had a friend call me on a hot July 4th weekend. He had family over from out of town for the holiday, a house full of people and his A/C failed. He called me and told me he tried to get a repairman but none he could reach would come until after the holiday. So I went over there with my gauges, vacuum pump and a tank of R-22.
When I put the gauges on it there was no refrigerant in it at all. So we went along the line set to look for a leak, and there was no evidence of damage to it. So I put the vacuum pump on it and and tested to see if it would hold vacuum and it did. So I ran the vacuum on it for and hour and recharged it with refrigerant. It ran fine and I was the hero of the day.
I told him if the charge ran down again he'd need to call somebody to track down the leak, but it never did run down. I checked with him years later and he said the system was still working fine, no complaints. They sold and moved about 10 years after and never had any trouble with the A/C during the remaining time they lived there.
The house was in a semi rural area with the condensing unit at the rear of the house, and no chance of random traffic thru the fenced backyard. However there were several kids there between his own and their cousins. The moral of the story is the locking service port caps are a good idea if you have kids.
I like how you cut off the yellow hose filled with liquid refrigerant early and allowed it to finish charging the system. What attention to detail! I love your clarity. You are a true friend! Thank you for all of your hard work!
Use virtual hug subliminal for your ac
Could you advise on how to check and add refrigerant to room air conditioners?
Seriously life changing for me you learn new things everyday 🙏🏼‼️
@@michaelkucher6346 do you mean the widow shakers??
Vacom and gaz chergd cylder opset puting liquied cherginv scushion pugering snd scushio chegd 120to 130cherge smerchecking systom totadlg checking good wofking no no gas purged good way leck checking fixe
You are a great A/C tech . If there was young apprentice wanting to learn the A/C biz you would be the guy I would want as an instructor ... Kudos to you and your expertise
I'm currently looking for an hvac job, fresh out of community college hvac program, and I wish he was my instructor
don't be nervous, keep studying 24 hours... eat, sleep, and live in the book and in the field...@@andrewkuebler4335
This man knows what he’s talking about! Respect!
This was a great video! Helped me out alot...my instructors from Institute of technology HVAC sucked....didn't have the patience to instruct accurately cutting corners is what I see from them. Thank you Sir for the lesson.
Best explanation I’ve seen on the internet with usage of tools,temps gauges and charts ty your a lifesaver! This is a field I’ve been interested in for a very long time. My son is also liking it!
Super job showing the correct use of sub cooling and super heat application. Thanks
I watched videos from several other 'folks', and read many articles. I have to say, your video is by far the best available, light years ahead of everyone else. You explained not only the how, but the why, in simple terms. If you were living in my area, I'd hire you in a heartbeat!!! I'll subscribe and buy the book to support your site. Keep up the great work!
Great video ! I'm a retired HVACR tech and it's nice to view your vids to keep me in the loop of HVAC
Sir your higher than a pioneer!! Superb job!!
New subscriber. I went to tech school back in '99 and worked for Sears and a couple of other companies until getting hurt and had to quit. These videos help keep me sharp because everyone knows that if you don't use it you lose it. Thanks so much!!! Well done.
Your a great teacher and a hellofa expert at explaining how it is done at your level. Thank you and right on brother.
Thanks for uploading this video. For the community.
On the older r22 systems I usually went for 8° super heat where most systems preferred 12°. Never had a single complaint. The differential between return and supply Temps were preferably 14-21°. Anything less usually indicated a blocked evaporator coil.
I thought it was funny he "forgot" his gloves, probably didn't though. :P
My Canadian Tire DIY min split that I installed 12 years ago is still working good. Going to put you guys out of business lol. Paid a thousand for it.
Got 2 watch several MORE times in order 2 FULLY grasp or understand! Ths 4 uploading VERY helpful n knowledgeable video indeed!
Really enjoyed it. Funny, plan on re educating myself and head back to school. I am retired, but what the heck? Called a tech and I knew more about charging the system than he did. But it cost me $350 due to the fact I am not EPA certified could not purchase the refrigerant. Well, thank you. Liked your teaching method.
Compressor - pressure raiser
Condenser - heat rejector
Metering device - pressure dropper
Evaporator - heat absorber
For sure one of the best videos I have watched pertaining to filling with the why's and how's. This video has certainly left enough of an impression on me in regards to filling systems. I will admit that I have filled a little too fast in the past based on how low and slow you let the gas in.
Thank you for your professionalism and explanation. I look forward to viewing more of your videos in the future.
Here in Utah if the inside heat load isn’t high enough, we will restrict airflow with bags on the outdoor condenser to manually create it. Great video 🤘
Watching and learning from Papua New Guinea...
I had to watch 4 times to fully understand, but it worth it, thank you
This guy Def knows what he's upta. Gunna show all this to the trainees
I was offered a job to learn hvac and the guy training me just plugs in low pressure gauge and fills it super fast then we're out lol. Usually 2 minutes or less we're out of there. Glad to know the correct way now. I'll remember so I don't look like a moron if I ever start at another company
All pro. Common sense and doing this right the first time.Thank you
Very informative video. My mini split is not blowing cool air and I watched some videos and it mislead me. I thought, my system is over charged. After watching your video I understand the whole system how it works. Thank you 🙏
Very nice, now I understand the importance of temperature. Great video and thanks!
Very comprehensive and easy to understand even for a DYI homeowner such as myself. Thank you!
You can’t handle refrigerant without EPA
@@thedesire3225😂😂😂
You’re excellent! I’m a student and your videos are amazing. I bought your book as well and it’s so thorough!
Thats so encouraging, thank you!!!
Great video that gives real insight of charging the ac system
Good demonstration for someone that's still in school👍
Very helpful!! Thank you for this educational video! 👍
Great videos props to you man details on point I’m taking notes re writing my notes
The best tutorial which I have seen yet. Geery
Glad it was helpful!
I just bought all cards and your book on Amazon. Great work.
Gerry
This was my lab this week in school 😎 I did okay could’ve done better but I’m learning
😂 real world ac guys do not do this. Great video explaining how it's supposed to be done.
It’s unfortunate a lot of real world tradesmen take no pride in their work. People are paying for work to be done the way it is supposed to be done.
Speak to yourself in Sweden there is probably Max 5% of people that does not do this. The rest of us has a cefirticate and needs to know all this in order to work with refrigirants.
@@martinpettersson5254 your definitely right but the saying goes "speak for yourself"
This is a regular standard procedure if your not purging your lines you shouldn’t be doing HVAC/R leave it for the pros seems like a lot of old timers never practiced this method or using a micron gauge in a vacuum
@@sbjetski1853 I’ve ran into 3 old timers so far that been doing it 30+ years and they don’t know shit running these systems into the ground
Great video. Very clearly explained.I've serviced lots of cars but never a house. Just had an HVAC company come in yesterday. Guy quoted me $250 per pound to add about two pounds of R22.
Insane...with the right license it can be purchased right at $34-36 per pound from Ability Refrigerants. A mark up of even $100 per pound I could accept but not $250.
Told him to take a hike.
Excellent video very clear on how to calculate refrigerant based on super heat. You did not mention how big is the unit i mean the capacity on which you worked, if you please mention it on your answers, thank you.
i think he mentioned its a 2 ton system?
He did mention it!
yeah, he is the best!!!! hands down! thanks, Craig for sharing have a nice 4th of July weekend.
Great training. I wish tech's made better pay, I might become one. Opening my own service company might be worthwhile. Can't have enough HVAC tech's during the summer in Arizona.
Absolutely excellent tutorial. Ordered your quick charts because of how happy I was with your explanations. I do have a question though, what’s the best way to determine if a system is using a fixed or Txv application? Thnx
Look on the manufacturer's plate on the condenser outside. If it says something like "TXV Subcooling 12," then it has a TXV. If you cannot find that stated anywhere on the plate, then you don't have a TXV.
The old-timers that taught me the business purged the air at the service hose manifold fitting, same but different. Very little refrigerant loss.
This is great when yur house is at 71 degress and also outside. But I wish youd do this with temps like we have here with 113 outside and 79 inside. Im sure the numbers would be off the charts. we exect to get over 117 in a couple of days. Yes here in the phoenix area.
This is a very interesting scientific method of measuring the system performance and the actual charge required to obtain optimum. But I wonder if simply filling it to the manufacturer's pressure specifications is also close enough for as they say government work?
Refrigerants are charged by weight from the factory. Most manufacturers recommend replacing the refrigerant when a leak occurred on R410A because it's a 50/50 mixed R125 and R32 refrigerant. On a car, it's completely normal to be low in refrigerant after 15-20 years because of the hose but not on a window and split type AC that uses all metal pipes. Low in Refrigerant simply means there is a leak. Very difficult to find a leak on R410A because it only leaks when pressure is very high. That is why the pressure test is done at 500 psi. It's probably leaking on the flare connection because 410A requires wider flare.
No wonder why AC techs are so incompetent. They made their own procedure instead of reading the instruction manual.
Very informative. Beginner HVAC
great video and very detailed that's the most important thing!!! good job!!
Thanks Craig. Very good and clean explanation of vac procedures. Thanks for sharing.
Thanks! Just saved me a whole lot of money.
I had yalls book and gave it to a helper whom it seemed was into it. Never saw that book again smh. May have to buy another n not give it away. Those cards are good for those who get overwhelmed and when you do your memory goes out the window like me. 👍 this channel is the sh*t
I can agree with everything except the part you said about the R-410a being released to the atmosphere cause damage to the ozone as R-410a has a 0 ozone depletion potential.
Like to use these videos for my employees,again great job.
Really worth the time spent,
Thanks teacher, for such as excellent videos.
Thanks for sharing an in depth view on this!
Another excellent tech vid..really clear & easy to understand the procedures 👍🏻
Cheers
Wish I had half this guy knowledge I need to go work for this guy for fee.
* Free
Yeah,I'll join you,not hard but it is all about the sequencing & timing ,patience as well 😅
Please do some hack job videos. For example add moisture on purpose to a working system to show what happens. Add incorrect type of refrigerant to a system to show what happens. More learning from explosions. Thanks for all your valuable info.
Yes, learning from explosions is always a good thing! I just need 1 explosion to remember for something for life.
Holy shit..my brain hurts.. I've watched 3 times. I'm used to R-22 beer can cold.😂 I just was handed a property of 400+ units all 410 A.. multiple units not cooling.. I'm trying my best and you definitely helped bro ty.. But with that said I'm still lost...
Thank you for teaching. Need videos like these!!
Unfortunately, in S.E. Texas, there are many who are working full-time in the a/c business who are pretty clueless but the a/c supply stores protect them anyway and won't sell to an unlicensed homeowner.
If it was 72degrees F and low humidity, I would just open the windows!
Thank you for a very informative lectures.
What Instrument are you using to check the indoor wet bulb temperature? I don't see it listed in Your tools list above. Well done video's!
He mentioned a psychrometer
Another great video from Craig👍. Is this is a new method of bleeding air out of the manifold hoses?? I recall the first method where after connecting hoses to the valves, you loosen each hose at the manifold end. Is this new method better ??
The worst air bleeding technique I've ever seen .
I actually started bleeding it the way he does a few years ago. To me, it’s the best way to do it.
I was taught to bleed them at the manifold. I think that’s the worst way to do it. 1) oily manifold. 2) I always felt there was still air in the manifold that didn’t bleed out.
Doing it his way (which he takes a long winded way of explaining) you get all the air out and stop oil from getting all over your gauges.
How I wish you mentioned PSI readings alongside-- against the temperature readings... for my understanding. I kinda relate better that way... I know you said using the temperature readings works better, that super-heat calculation seems to be messing with my head 😂
Learn something new every day
Always charge 410a bottle upside down to get liquid. This gives a good mix of the refrigerants used in 410a.
In Canada we have different cylinders with dip tubes
@@kristinavee1012 what color are yours?
@@kitty9374 I am pretty sure the cylinders are the same colours. Pink for 410a and green for r22 for example. But I just meant we have dip tubes so you don’t have to invert the cylinder
Thank you for great video. Kind regards from Slovenia
Thanks for watching!
I been working in a company for almost 2 years and I like this job but the ppl that I work with they don’t really want to teach me or they don’t want me to learn I already know some about this job but I should know more already since been doing it for almost 2 years all they ask me to do is ductwork and run flexes.
So, weight of charge is not as important as superheat is my absorption.
i wish i have your patient
i"ll be finish three calls by now very nice job thank you for posting
Great video . Booked on a course in the uk for this at the end of the month. Just a shame you guys use imperial as I’m trying to discard the measurements in my head whilst trying to remember the other bits . Very well informed though .
Congrats, great video! Fully detailed and straightforward theory, cheers from Brazil!
Thank you very much!
Thank you for sharing your knowledge.
You're welcome, glad it was helpful!
great explanation superheat and subcooling.
Great video, thanks for sharing
Thanks for watching!
I'm learning this trade thank you so much for free instruction. Where can I buy your charts books etc...?
www.acservicetech.com and www.amazon.com/shop/acservicetech
@@acservicetechchannel
Thank you just bought!!!
I have a new Rheem 3 ton unit, compressor, new line set, furnace, and evaporator coils, all new R8 ducting, and registers were sealed and a new thermostat. My question is when it is 100 degrees outside my new unit will not cool below 77 degrees. My home is 1408 sq. ft. They don't take outside temp with inside temp for a cooling target number what am I missing, just paid 14,000 for install. Hope you can answer they are coming today to check my charge, why should they have not done this from the beginning, beer can cold charge it seems like. Please answer desperate !!!! Also wanted to add my new unit has to run constantly to maintain 77 or 78 degrees !!
Why utilize a Manifold at all? The temperatures of the Suction/Liquid lines, ambient air, indoor air temps, against a manufacturers Charging Chart will give you an accurate charge indication of charge without losing any refrigerant.
Tampa Florida check in thanks for the content
I watch this video always telling degrees, what is the unit of measurement is it Celsius Fahrenheit or Kelvin? While charging the system you did not tell the side of compressor current? Your only on the temperature and pressure,, adding refrigerant is adding current. But your video is very useful
Should upload same tutorials with the field piece digital manifold. It's hard to see the numbers through the video with regular gauges
Great video. Very much detailed and very helpful. I am not in the USA and I would like to ask where can I get those gears you are using.
Thank you. I’m just a homeowner and was thinking I shouldn’t check my sytem often, perhaps only when I don't think it’s cooling as well as it should AND after I have checked my filters….would all that be correct?
How much are you currently charging your customers for refridgerant 410A?
Last question, I’m guessing it’s not a good idea to check my system pressures and temps in the winter…what outside temps should I check my system if I suspect it’s not cooling correctly. Thank you again for a very informative video!
Great video man. Your the man. Love the way you describe every necessary step🗣👌✌👍
Great work professor thank you so much
You are very welcome
Thanks Craig! this is a Cool Video!
You should add refrigerant to the factory charge amount
Excellent work clear video thank you!
Glad it was helpful!
Great video. I view everyday and enjoy it each time. Very informative. I bought the book.
VERY WELL MADE VIDEO AND WILL WATCH MORE NOT TO GIG YA BUT TO SEE YOUR WAY YOUR ARE THE WAY LIKE MANDO :)
i have one query as i come to know that R410 A need to be charged in liquid phase then why we are inserting it to vapour line. It could Damage compressor
Awesome video! Thanks for posting. BTW, your "Refrigerant Charging and Service Procedures for Air Conditioning" book is well worth the price and awesome also!
Question for you. Could you keep the 410 - A bottle upright and get only gas into the system instead of charging with the bottle upside down and getting liquid?
No, apparently 410a is made of two different refrigerants and in the liquid form, they will remain mixed correctly. The gas above can be more of one refrigerant than the other.
I have a question. When you connect the blue and red hose to the compressor there were hexbolts... do you not need to open them? Just wondering if you need to open them or don't touch them. Thanks for great video.
Hi, sir. I like all your videos, and they are very informative. I have a question about refrigerant R410A. If there is a leak on the low side, can we pump down the remaining refrigerant, fix the leak, vacuum the low side, and then top up, or do we need to recover and fill it with new refrigerant?
You can pump it all into the outside condenser unit, close the low side valve, then break the line on the building side, fix it, pump down the building lines, then open the valves and run again. Look for pump- down videos…
Wow so much information thank you
So you must add 401a as a liquid?
Because it is actually a mix of two different refrigerants that of course have different expansion temperatures, so if you boil off directly from the bottle one of the refrigerants will boil off first causing a concentration of that refrigerant in the released gas/vapor.??? Kind of like a distillation tower.