R-22 and R-410A Operating Pressures on Air Conditioners! Checking the Charge!

Поділитися
Вставка
  • Опубліковано 5 тра 2022
  • In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Temperatures When Checking the Refrigerant Charge of an Air Conditioner! Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our Related Videos
    • Charging R-410A Refrig...
    • Checking the Charge of...
    • Practice Checking the ...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
    All Our Educational Products on Our Site: www.acservicetech.com/store
    All Our Educational Products on Amazon: amzn.to/48pDd82
    Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
    Mini Split Paperback on Amazon- amzn.to/3ytHJSs
    Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
    Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
    Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Online Resources!
    Our HVAC Calculators: www.acservicetech.com/hvac-ca...
    Our Newest Articles: www.acservicetech.com/articles
    Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
    Our Other Resources: www.acservicetech.com/resources
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Tools Used in Our Videos!
    Tool Links on Our Site: www.acservicetech.com/tools
    Our Tool List on Amazon: www.amazon.com/shop/acservice...
    Support the Channel by purchasing tools through TruTech Tools!
    Use this link www.trutechtools.com/?aff=8
    Save 8% at checkout using code "acservicetech"
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Follow Us On Our Social Media & Podcasting Channels!
    Patreon: / acservicetech
    Facebook: / acservicetech
    Instagram: / acservicetech
    X: / acservicetech
    LinkedIn: / ac-service-tech-llc
    Tiktok: / acservicetech
    Spotify: open.spotify.com/show/74KXLz5...
    Apple Podcasts: podcasts.apple.com/us/podcast...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    ⚠️ Disclaimer:
    Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    #hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #operating #charge #airconditioner #pressure #checking #acunit
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

КОМЕНТАРІ • 155

  • @davidisaacs9469
    @davidisaacs9469 2 роки тому +89

    I have 38 years in residential construction. I'm currently in hvac night school. I get as much or maybe even a little more out of your videos and book. I just wanted to take a second to thank you.

    • @acservicetechchannel
      @acservicetechchannel  2 роки тому +5

      David, thank you for your encouraging note!

    • @ZeldaxLegacy
      @ZeldaxLegacy Рік тому +1

      Same, friend. Not as many years as you,but this channel is far more educational than my schooling is. GL on your new adventure!

    • @turboskywalker9108
      @turboskywalker9108 Рік тому +1

      Yeah going to class doesn't teach you the actual work that needs to be done it's all legality and policies and what NOT to do 😅

    • @jollyscaria1922
      @jollyscaria1922 11 місяців тому

      R22 suchion 65t70 dis.. 270 320... aR410 suc..110 to 125 . Dis 430t0450..

    • @Voyager23B
      @Voyager23B 7 місяців тому

      He is the best! I purchased his manual and it has been my go-to reference for HVAC for years! I always refresh myself by watching his videos.

  • @vernroach3413
    @vernroach3413 Рік тому +11

    Excellent videos...I use them as refreshers...Retired, but still working the trade occasionally...Keep moving guys, keep using your brain and learning...Keeps you younger than those who don't..My only wish is they'd land on one refrigerant for the AC.

  • @RaulGonzalez-lb1ok
    @RaulGonzalez-lb1ok 2 роки тому +5

    Very helpful! I’ll tell you this! The hvac company’s I’ve worked for before never taught me this. N they never checked Freon like this guy!! Wow!!!

  • @shawnpierce6785
    @shawnpierce6785 21 день тому +1

    Your video helped me understand pressures. I shared it with a buddy of mine. We both wanted to give you a big THANK YOU!

  • @jpbarista3253
    @jpbarista3253 Рік тому +7

    Best video out there explaining the pressures. Thanks 🙏🏻

  • @resurgensix
    @resurgensix 2 роки тому +14

    Thank you Mr Mig. These are basics an apprentice like myself NEEDS to know. Your content is the first I have ever seen to identify these targets. Thanks again. Loving your book!

    • @acservicetechchannel
      @acservicetechchannel  2 роки тому +1

      Robert, loved meeting you over at Bryan's place. You are a heck of a guy and the company where you are at is extremely fortunate to have someone like you! Well ballanced, intelligent, determined, sales experience, professional, respecful, the list goes on!

  • @flatearthautopilot9892
    @flatearthautopilot9892 2 роки тому +2

    Dude, this is the best tutorial video I’ve seen. Thank you SO MUCH

  • @joshstuckey9977
    @joshstuckey9977 Місяць тому

    Did residential instal as a kid now I’m on a offshore platform as a electrican and one of my responsibilities is keeping the 30 year old AC running and lord it’s whooping me but I appreciate your help on this

  • @bayouflats5054
    @bayouflats5054 2 роки тому +8

    I’ve been relying on your info since learning HVAC at fast paced multi family apt complex maintenance dept. , as this particular industry doesn’t lend itself to exacting practices. Appreciate

    • @shawnpierce6785
      @shawnpierce6785 21 день тому +1

      Same. This video alone was a breath of fresh air for my brain.

  • @Danny-fs1hk
    @Danny-fs1hk Рік тому

    This guy is an excellent teacher

  • @johnpark7990
    @johnpark7990 3 місяці тому +1

    Thanks for ❤.
    That is the best explanation of the sub cooling and super heating in the air-conditioning system.

  • @Samir72
    @Samir72 2 роки тому

    Very well explained, Thanks Craig!

  • @realestateinfonet9041
    @realestateinfonet9041 9 днів тому

    Superb info! Thanks!

  • @jimmysegovia2688
    @jimmysegovia2688 2 роки тому +1

    thanks, Craig for sharing!!!!! you're the best man!!!!...

  • @user-kt2hb8xr3p
    @user-kt2hb8xr3p 2 роки тому

    Great job, thank you brother. You are so talented

  • @doorguru168888
    @doorguru168888 Рік тому

    Thanks! I'm starting to grasp it. Excellent video!

  • @user-gc1gj2hm9n
    @user-gc1gj2hm9n 7 місяців тому +1

    thanks for the sharing knowledge. very Helpful

  • @antoniolaracuente437
    @antoniolaracuente437 2 роки тому +1

    Great job Mister Rogers thank you for all that information

  • @maximustitan8171
    @maximustitan8171 2 роки тому +3

    This a very nice art and animations on how home AC works. Thank you.

  • @theninetwo7266
    @theninetwo7266 2 роки тому

    MAN thank you for taking your time to teach

  • @Bruce19
    @Bruce19 2 роки тому +2

    Great explanation!! Keep up the great work

  • @cesarbernal3648
    @cesarbernal3648 Рік тому

    Very informative! Thank u!!!

  • @chasdenver
    @chasdenver 2 роки тому +1

    Craig, I just purchased some of your troubleshooting guides, HOPE, they are as good as your video instructional video's!!

    • @acservicetechchannel
      @acservicetechchannel  2 роки тому

      Well, we put a lot of work and testing into those so hope you enjoy them. They presently have 4.7 stars out of 5 on amazon. Let me know what you think after using them for a bit!

  • @motactr8018
    @motactr8018 2 роки тому

    Great video! 👍🏽

  • @douglieberman6406
    @douglieberman6406 2 роки тому +2

    R 22 or R 410a can be checked with ONE gauge as though you are charging a WINDOW UNIT (package unit) whose copper tubes start having low pressure and build up frost on them. You tap into a small copper line with a tap and use one gauge and check the one pressure for a specific temperature.

  • @raysoucie489
    @raysoucie489 7 місяців тому

    VERY good Info.----- THANKS !!!!

  • @pizzle1011
    @pizzle1011 2 роки тому +2

    👌🏾👌🏾👏🏾👏🏾 always a good refresher watching your videos. Easy to understand and thorough. Thanks

  • @clemochoa6430
    @clemochoa6430 Рік тому

    Gracias Professor muy buen CONSEJO 🙏🙏🙏👍👍👍😍

  • @realestateservicessaleshea99
    @realestateservicessaleshea99 2 роки тому

    Thanks again for the videos, always appreciated!
    🍺🍺🍺🥃🥃⛳🎳
    Stay safe.
    Retired (werk'n)keyboard super tech. Wear your safety glasses!

  • @lamberto6405
    @lamberto6405 Рік тому +2

    Great content and I've been searching for a log time! Thanks!!! I had a tech check my A/C on an R410A Rheem unit. As soon as he saw the high side was 320 and touched the small line and said it was too hot (it was on the hot side vs warm) he said that the coil was not good. It was 95 degrees out. The coil seemed clean and it was clear and in good condition (no corrosion). We hosed down the coil and the temp went down but he re-confirmed the coil was bad. Can a coil be bad if it seems okay (air flows through is that the fins look great)? I trust the A/C rep but for my own learning.

  • @muhammadusamakhan5295
    @muhammadusamakhan5295 2 роки тому

    Very impressive sir

  • @KET1979
    @KET1979 2 роки тому

    very good tips

  • @johnhess2754
    @johnhess2754 Рік тому

    my friend, your a wealth of knowledge, thanks so much

  • @djkaneck1
    @djkaneck1 2 місяці тому

    Well done

  • @caryandgrace
    @caryandgrace 2 роки тому +3

    Thank you sir! These are essential viewing for new techs.

  • @catfish1161
    @catfish1161 17 днів тому +1

    Thank you

  • @khuongvtube
    @khuongvtube 2 роки тому +3

    I saw many articles about min. of 10 degrees superheat at evaporator suction line and 20 degrees at near condenser to avoid flooding back from compressor manufacturers. So my question is which one we should go by, In Texas, ambient temp can be 75f in the morning and 100f in the afternoon. My ac superheat taken at suction line on the outside unit can be 5 in the morning and 20-25 in the afternoon. I keep my thermostat setting at 77 degree throughout the summer. If I depend on the target superheat from my outdoor dry bulb and indoor wet bulb temp, it could be 0 superheat sometimes according to the chart.

  • @thesilentonevictor
    @thesilentonevictor 2 роки тому +1

    Great information 👌

  • @Garyganeu
    @Garyganeu 2 роки тому +2

    If you think that s a lot to think of, try charging a low ambient unit with a accumulator and a receiver when its o OA.

  • @batjiyasanthos5526
    @batjiyasanthos5526 7 місяців тому

    Very informative lesson. Thank you sir

  • @ronnyt9279
    @ronnyt9279 2 роки тому

    Thank great info

  • @abecontreras7940
    @abecontreras7940 Рік тому +1

    Great video.. I been running into problems like not being able to get my low side above 100 psi.. can you make a video explaining why and solutions

  • @morallyinsane7639
    @morallyinsane7639 2 роки тому +6

    Unfortunately in the field, it’s quite different then in a controlled classroom setting. Let’s assume the unit was installed correctly for the space, then this is a good lesson. However in the field we all know a lot of times that is not the case. High efficiency condensing units run cooler and CFMs can effect TXVs. So the easiest way is to use your suction gauge and check the charge under a high load condition.

    • @taiwanluthiers
      @taiwanluthiers 10 місяців тому

      I notice what looks like a capillary tube from the condenser before it leads to the liquid line. I'm not sure what it's there for but it really causes the liquid pipe to feel cold. I got a mini split and I guess things must operate differently in a mini split.

  • @douglieberman6406
    @douglieberman6406 2 роки тому

    Because R 22 and R410 a on the PT chart has pressures as though they are mixtures I would use them in such places like a window unit that is low on freon, like a small package unit as though as you only need to check one pressure for specific temperatures.

  • @ejohnfall
    @ejohnfall 2 роки тому +6

    Good information like always

  • @sivasagarvemula534
    @sivasagarvemula534 2 роки тому

    Hi nice video please make videos on r407c ,405 and 134a also about pressures

  • @farabirahmannaim181
    @farabirahmannaim181 2 роки тому +1

    Good informasirion

  • @anthonybarragan1687
    @anthonybarragan1687 Рік тому +1

    The pressure windows that you state for both high and low side pressures work for residential, commercial, and industrial units? Or only certain HVAC system settings?

  • @patbrock7460
    @patbrock7460 2 роки тому

    The reply was we only use sight glasses in refrigeration not AC.. When I started doing AC in the early 70's many Carrier units came with sight glasses, car AC came with sight glasses. If you have say 10 degree sub cooling you should have a solid flow of liquid in the liquid line.. I do realize units with multiple rows of small tubing are easy to overcharge.

  • @monteglover4133
    @monteglover4133 2 роки тому +2

    I am a 40+ year HVAC&R service tech, I usually use temperatures when working on space cooling systems I work on have 4 different refrigerants, in addition to refrigeration systems

    • @abulhobatte151
      @abulhobatte151 2 роки тому

      Question here man so is this R22 PSI values for all split type ACS whether 12000btu 18000btu or 24000btu etc or is he talking about HVACs here

  • @wasimedoo7994
    @wasimedoo7994 2 роки тому

    Very good information bro what is the replacement for r22 Freon and what would be the gage reading thanks

  • @joeneal21
    @joeneal21 Рік тому

    Working on a unit with a 4-5 degree subcool when I add refrigerant the liquid line temp increases with the head pressure still giving 4-5 degrees SC. I change Evan filters. I replaced condenser fan motor that was overheating. What am I missing here?

  • @Abdullah-hc1cz
    @Abdullah-hc1cz Рік тому

    If it capillary tube is using for the metering device,what methode should it use for charging? Is it superheat or subcooling?

  • @mahmuedsalah
    @mahmuedsalah 10 місяців тому

    If the temperature allows, pour cool and super heat in the air conditioner, freon r22 and r410

  • @davidnunez7889
    @davidnunez7889 2 роки тому

    Awesome video Craig great information

  • @neutrodyne
    @neutrodyne 2 роки тому

    If a system is properly charged should the low line coming into the compressor be sweating on a hot day while the system is running?

  • @lucdumouchel3864
    @lucdumouchel3864 Рік тому

    Hi. I was working on a commercial A/C 12 1/2 tons.
    I checked the CFM. I'm close to 5000 CFM.
    Lines are about 60 feet. It's a un
    it with 2 compressors
    2 Things
    1: When I try to get 10 subcooling, it may play between 3 degree
    to 12 degree.
    2: I can't get a superheat between 10 to 15 degree.
    it stay between 22 to 25 superheat.
    The suction line outside is about 20 feet.
    My questions are: The fact that the subcooling is changing that much, should I change it?
    Also: if the superheat is that hi, is it another reason to change it?

  • @Californicate1
    @Californicate1 11 місяців тому

    If the low pressure sensor is open due to low charge , how do you allow it to run prior to checking charge ?

  • @markgallagher1376
    @markgallagher1376 Місяць тому

    What if I have TXV metering, but my condenser nameplate doesn’t have sub cooling target? The manual doesn’t show it either.

  • @manna5610
    @manna5610 6 місяців тому

    What the low ands high ranges for heating. Inside temp, 70 and outside temp 30. AC works fine but the heating does not. Duct temp gets up 90 and then gets cold. EH temps n after a few min. Just had the R22 topped of. the HVAC tech said, pressures are fine, did not resolve the problem. this is 2 x now on the same problem. Not defrosting, OD fan is still running. It might be a bad DF board? I'll check it later today. Or the pressures are still low? That is why I'm asking. thanks!

  • @bobbyyoung2831
    @bobbyyoung2831 Рік тому

    How do you charge the unit when it start cycling because it doesn't have enough freon in it won't stay running so how do you charge it

  • @joshuaramos9676
    @joshuaramos9676 Рік тому

    Hey man I’m new to all this and I wanted to know what my low side and high side PSI should be at my temperature outside are between 80-100f

  • @yatskie1632
    @yatskie1632 Місяць тому

    does these value applies to 1.5HP split type ac that is running R410A?

  • @Jason-qe4tp
    @Jason-qe4tp 2 роки тому

    On your quick reference cards the troubleshooting ac systems card, what do you mean by capacity on the chart? Btw these are awesome...like my own cheat codes

  • @LubaLuba1
    @LubaLuba1 6 годин тому

    @1:13 you say a range from 58 to 85 PSI, is that off or on? And 1:23 how long will it take to freeze because I think it froze while adding refrigerant.

  • @joselicop872
    @joselicop872 Рік тому

    Should we charge R410a using liquid or gas vapor to the suction line?

  • @Jason-qe4tp
    @Jason-qe4tp 2 роки тому

    Oh yeah also are you making a furnace and a boiler quick cards in the near future....like b4 heating season cause ill buy them

  • @artojokinen1700
    @artojokinen1700 2 роки тому

    Would you have similair info on R32? R410A is getting uncommon. New installations tend to be R32.

  • @devotedanaheim1575
    @devotedanaheim1575 13 днів тому

    What if my unit doest have the sub cooled rating chart ?

  • @pryanikfromrf4459
    @pryanikfromrf4459 2 роки тому

    Да я с тобой согласен. Минеральное масло не дружит с синтетикой..... у меня была проблема: агрегат 64года на фреоне 12, вот я вспотел ( запчасти нет в продаже уже очень давно)

  • @Jpriatna
    @Jpriatna 2 роки тому

    How to determine super heat besides reading

  • @piezomotor
    @piezomotor Рік тому

    Hello, thank you for this video. I have a question - my R22 bottle has the red and the blue valves but my R22 manifold has the yellow input house. Do you know by any chance where I connect yellow house? To the red or the blue valves?

    • @sawdust85222
      @sawdust85222 Рік тому +1

      I would suggest not connecting them to anything!

  • @timdestasiohvac
    @timdestasiohvac 2 роки тому +2

    Great vid. I think we should STOP thinking and learning and talking refrigerant pressures, and just use saturation, line and air temperatures.

  • @stephwaylonwells3218
    @stephwaylonwells3218 2 роки тому +1

    👍

  • @abdalqadr1
    @abdalqadr1 Рік тому

    ❤❤❤❤

  • @spartan5106
    @spartan5106 7 місяців тому

    great video! Thank you

  • @derekprreira3214
    @derekprreira3214 24 дні тому

    I have a LG split unit, it was cooling the previous night , but today morning it wasnt cooling at all, so i checked the suction line is warm and the liquid line is hot at the outdoor unit. What could be the problem. Kindly advice

    • @xiangqian6688
      @xiangqian6688 23 дні тому

      具体要现场看一下,不制冷有很多原因

  • @kariesistansteckend2196
    @kariesistansteckend2196 2 роки тому

    a mini Split only for heating.
    should i mount it on the floor or on the ceiling ? or in the middle ?
    Can someon answer the question ?

  • @brianosegueda3622
    @brianosegueda3622 2 роки тому +10

    Great stuff as usual Craig!
    Lately, we been using R 427 and R 407 as replacements for R22. However, our gages only have the common readings: 410, 404, 22. How similar or different are the temperatures for 427 and 407 to R22?

    • @TheDave5619
      @TheDave5619 2 роки тому +5

      You can download a PT chart app on your phone and input the psi on your low gauge and set it with the r427 or many others and it should show the temperature of the that refrigerant. And you can compare

    • @tttota5421
      @tttota5421 2 роки тому

      Can you use 407 to any brand and do you usually clean the line set
      Bc this guy wants to charge 200$ per pound on R22 🤣 witch is not worthy

    • @brianosegueda3622
      @brianosegueda3622 2 роки тому

      We use 407 as replacement for R22, however, we do NOT use it on heat pumps because R407 is a blend.

    • @juntang72
      @juntang72 Рік тому +1

      @@brianosegueda3622 why can’t blended refrigerant be used in heat pumps? R410 is being used widespread in heat pump ,it’s blend too

    • @sawdust85222
      @sawdust85222 Рік тому +1

      @@brianosegueda3622 410a is also a blend. Will you elaborate on why you don't use 407 on heat pumps?

  • @carbondioxide9940
    @carbondioxide9940 2 роки тому

    Is this with the system running ?

  • @TheEmoLab
    @TheEmoLab 4 місяці тому

    Is it possible to know how many pounds are in the unit

  • @nsahar4214
    @nsahar4214 2 роки тому

    If you have a 3 ton blower and 3.5ton AC is that system going to freeze up? Thanks

  • @patbrock7460
    @patbrock7460 2 роки тому +1

    Question some people love sight glasses, some people say they don't work well with 410a ??

    • @acservicetechchannel
      @acservicetechchannel  2 роки тому

      We don't use sight glasses for air conditioning, only refrigeration. In ac, we measure subcooling to see not only if the refrigerant is in the fully liquid state but how many degrees of subcooling are present, thanks!

  • @douglieberman6406
    @douglieberman6406 6 місяців тому

    I know that putting switches in parallel in electricity is actually a short circuit when closed! Just to add a point somewhere!

  • @Ojeramup12
    @Ojeramup12 10 місяців тому

    Clear as mud.

    • @acservicetechchannel
      @acservicetechchannel  10 місяців тому

      It takes a while to understand. Its not as simple as just pressures, thats for sure!

    • @Ojeramup12
      @Ojeramup12 10 місяців тому

      Totally agree.@@acservicetechchannel

  • @PhilipAlonzo
    @PhilipAlonzo Рік тому

    How many years should freon last my unit is like 4years old maybe 3 and its blowing a lil cold and warm could it be freon or capacitor?

    • @PhillipCooperNCState
      @PhillipCooperNCState Рік тому

      Refrigerant (aka freon) will out live the equipment... If a leak develops within the system, the refrigerant will leak out at a rate determined by the size of the puncture. A slow leak can take many months before the comfort level is noticeable. And most likely, the capacitor has nothing to do with your situation.

  • @bsiah9073
    @bsiah9073 5 місяців тому +2

    still have no idea what all means. sounds alien to me lol

  • @IndependenceCityMotoring
    @IndependenceCityMotoring 2 роки тому +1

    What if my my label doesn't specify the TXV rating? Has other pieces of info but not a TXV rating.

    • @acservicetechchannel
      @acservicetechchannel  2 роки тому

      It should say subcoolin grating on the outdoor rating plate or on the under side of that shroud. If it doesn't and it is a single speed unit, 11 degrees of subcooling can be used, thanks!

    • @MaMa-qh4dy
      @MaMa-qh4dy 2 роки тому

      @@acservicetechchannel My older Trane heat pumps don't give a target subcooling. Instead, the service facts include a graph chart plotting liquid line temp (horizontal X axis) vs liquid line pressure (vertical Y axis). Within the graph is a slight arc line that indicates the proper charge. At the intersection point of your X and Y values on the arc line, is below the arch line, then add refrigerant. If your intersection dot is above the arch line, then recover refrigerant. I don't know why Trane does this method. Seems like a little extra work.

  • @robcerda4602
    @robcerda4602 Рік тому +1

    Had a question do you have a book on electric heat

    • @acservicetechchannel
      @acservicetechchannel  Рік тому

      Not at the moment, just the new Inverter mini split book and the air conditioning/refrigerant book at www.acservicetech.com thanks!

  • @Houssem0880
    @Houssem0880 2 роки тому

    Thank you appreciate it can you please ad Arabic caption it will be good

  • @douglieberman6406
    @douglieberman6406 6 місяців тому

    Putting switches from negative to positive is a short circuit when closed!

  • @nickledimez4012
    @nickledimez4012 2 роки тому +1

    Thank you! Do you have a link to the tools you are using in regards to the digital meters? Thanks again!

  • @impossiblemans
    @impossiblemans Рік тому

    I hope in the future there will be an Indonesian translation

  • @sachinchawla1368
    @sachinchawla1368 2 роки тому +1

    नमस्कार सर जो वीडियो में जो टूल्स दिखाते हो वह ऑनलाइन अमेजॉन पर उपलब्ध तो होता है पर इंडिया में नहीं मिल पाता। इससे बहुत तकलीफ होती है न्यू ट्रलस नहीं मिल पाता है और काम करने में काफी दिक्कतें होती है Hello sir The tools shown in the video are available online on Amazon but are not available in India. This causes a lot of trouble, the new trullus is not available and there is a lot of difficulty in working.

  • @dennisqwertyuiop
    @dennisqwertyuiop 2 роки тому +1

    A coil with capillary tube,,is that the same as a piston ?

    • @practicemakesbetter7132
      @practicemakesbetter7132 2 роки тому +1

      A capillary tube or a piston controls the amount of liquid entering the A coil by restricting liquid flow, if you overcharge a system the low side gauge pressure will be above normal and the low side gauge pressure will be above normal. A TX valve controls the flow of liquid with a temperature sensing bulb, the TX valve maintains a steady A coil temperature, as a result the low side pressure remains relatively stable, even if the system is overcharged.

    • @dennisqwertyuiop
      @dennisqwertyuiop 2 роки тому +1

      Yes I know that they only talk about piston and txv valve,, so is cap tube same as piston?

    • @acservicetechchannel
      @acservicetechchannel  2 роки тому +1

      Yes cap tube and piston both fall under the term "fixed orifice" but the piston chamber can bypass refrigerant through and around the piston itself when the refrigerant flows in the other direction where the cap tube needs an external bypass, thanks!

  • @amealnet2495
    @amealnet2495 2 роки тому +1

    I’m not going to live long enough to understand the hvac technology

  • @liudxdx
    @liudxdx 21 день тому

    4:44 what’s the yellow device?

    • @BillyJackIII
      @BillyJackIII 5 днів тому

      Any form of Temperature Reading

  • @survivaldavid9802
    @survivaldavid9802 Рік тому

    Am looking for a job plz in any HVAC companies

  • @Zawo254
    @Zawo254 2 роки тому

    My 410-A Says 200 Blue and 400 Red😬😬😬

  • @Brokefootchuck
    @Brokefootchuck 2 роки тому

    My boss says mix 22 with 407c. I hate it. According to the maker you can add up to 25% of total charge without adding oil but the saturation temps are too different for my liking. There is no good replacement imo.