Connecting a 3 phase motor with 1 phase Power with Diagram

Поділитися
Вставка
  • Опубліковано 3 лис 2019
  • If you only have single phase power at your house,you can still connect a three phase motor with this tutorial.
  • Навчання та стиль

КОМЕНТАРІ • 438

  • @bongky8641
    @bongky8641 2 роки тому +5

    Damn, I've been looking in yt for someone who can decode this process for a quiet long time. Im glad ive found this. Thanks jean, you're new sub here

  • @michelney2915
    @michelney2915 2 роки тому +13

    At last someone has finally told me how to do it and also the formula for the capacitor/power. I have been waiting for thgis all my 42 year working life. Very didactical and explicit like no one has explained before. Thank you.

    • @bongky8641
      @bongky8641 2 роки тому +1

      Same thoughts here Michel.

    • @samueladegun8427
      @samueladegun8427 2 роки тому +1

      What's the formula for capacitor selection

    • @TheGirdijalla
      @TheGirdijalla Рік тому +1

      @@samueladegun8427 70 pr kw

    • @deanrowles3665
      @deanrowles3665 Рік тому

      I have 4kw 3 phase motor, so looking at the calculation, tbat works out to be a 280uf capacitor, have I got that right?

    • @fellangphakola1811
      @fellangphakola1811 Рік тому

      Why did he divide 70 microfarads by 10?

  • @varadarajanrangasamy8577
    @varadarajanrangasamy8577 3 роки тому +2

    Excellent presentation with content. Simple language. Easy to understand.

  • @jaysteven9652
    @jaysteven9652 4 роки тому +32

    I Don't care how he spells as long as he is explaining the right thing and i understand him, thank you jean for loading this video better than not loading this video. and thank you tamas for extra information.

    • @nevillewright5505
      @nevillewright5505 3 роки тому +1

      Always wanted to know how to do that. Thanks for sharing

  • @philliproberts3180
    @philliproberts3180 3 роки тому +3

    Fantastic always wanted to do that. Brilliant my lad. From Phillip Roberts Zambia central Africa.

  • @alex336k
    @alex336k 4 роки тому +5

    Top video and top explanation! Thanks and all the best. 🇬🇷👍🇦🇺

  • @peterhlokwa6002
    @peterhlokwa6002 3 роки тому +7

    Thank you man, I appreciate the video. I'm sorted now

  • @CCPANHEAD
    @CCPANHEAD 3 роки тому +2

    Simulating, very well presented, and valuable solution.

  • @nicolascutti9570
    @nicolascutti9570 3 роки тому +1

    This is the best explained video I have ever seen many thanks 🙏

  • @valborchardt3596
    @valborchardt3596 4 роки тому

    Thank you so much, this has been most helpful

  • @noearias2006
    @noearias2006 3 роки тому +2

    ONE THOUSAND THANK YOU,FOR YOUR VIDEO ,MARVELOUS

  • @graemehill5550
    @graemehill5550 4 роки тому

    So helpful another subscriber to you channel...cheers mate

  • @jhonnygovender6723
    @jhonnygovender6723 3 роки тому +1

    THANK YOU. EASY TO FOLLOW.
    WELL explained

  • @thinusprinsloo2112
    @thinusprinsloo2112 2 роки тому +1

    Hi Jean ..can you do a video about converting an alternator to electric motor ..
    Ive watched alot of videos on the topic but you explain it so easy

  • @brentconnock2513
    @brentconnock2513 3 роки тому +2

    Thanks from SA, well explained, even a dummy like me can understand

  • @danielteyehuago1633
    @danielteyehuago1633 2 роки тому +2

    Thanks for your sharing it with us. This is a great tutorial and very informative.
    dl

  • @ammardaffa
    @ammardaffa 3 роки тому

    Thank you man for always giving me coin

  • @victoryfirst2878
    @victoryfirst2878 3 роки тому +1

    Thank for showing the wire connections to use three phase motors. Peace

  • @christianworthinton8000
    @christianworthinton8000 3 місяці тому

    Thanks! Much appreciated. Subbed.

  • @adamw.8579
    @adamw.8579 3 роки тому +27

    To reverse rotation is enough to connect supply to other side of capacitor.
    Delta config ports from left:
    1 - power (live), 2 - power (neut.)+ cap, 3 - cap = left rotation.
    1- power (live), 2 - cap, 3 - power (neutral) + cap = right rotation.
    If configuration was changed to star You weaken motor substantially because lower voltage on winding section.

    • @xtesster
      @xtesster 3 роки тому

      hi, your answer catch my attention, however i don't understand by what is 1. 2. and 3. which one of the numbering represent U1 V1 W1 or U2 V2 W2? could you explain it in basic form?

    • @adamw.8579
      @adamw.8579 3 роки тому +1

      @@xtesster 1,2 and 3 are points of apply power: L1, L2 and L3 on typical motor terminal box description, it should be U1,V1,W1 row of terminals.

    • @easywaycircuit9233
      @easywaycircuit9233 3 роки тому

      what kind of capacitor use ( starting or running ) and how many uf for 3hp 3ph connect to 1ph 220

    • @adamw.8579
      @adamw.8579 3 роки тому +1

      @@easywaycircuit9233 For 3ph motor running capacitor only. 380/400V star configuration motor should be ran on 220/230V with delta configuration and 150uF capacitor (50uF/hp or 70uF/kW). Remember proper type of capacitor (motor run type and voltage ratings).

    • @easywaycircuit9233
      @easywaycircuit9233 3 роки тому +1

      @@adamw.8579 ok thanks so i need to use running capacitor @ 150uf for my ( 3ph , 3hp/2.3kw , 4 pole motor ) right ?

  • @GzzLuiz
    @GzzLuiz 4 роки тому +1

    I though I was hearing a whistle on my house, then I notice it was your video haha!

    • @oppored5947
      @oppored5947 3 роки тому

      pls what kind capastir n number you hv uesd runing or sitater?

  • @udehjosiahsnowwhite7761
    @udehjosiahsnowwhite7761 3 роки тому

    Wow great video. Thanks for the information.

  • @paulbester1595
    @paulbester1595 2 роки тому

    Thank you for the video. What is the biggest kW motor that this can be done on?

  • @h._assan
    @h._assan 3 роки тому +1

    That is amazing you are the best 👌🏻❤

  • @wynandels5801
    @wynandels5801 2 роки тому +2

    Lekka my bru... Dankie vir die video!

  • @Gallardo6669
    @Gallardo6669 4 роки тому +3

    Nice. Thx. Would have been nice to give values about amps and torque on 3phases vs 1 phase

  • @mohammadakram1530
    @mohammadakram1530 2 роки тому +4

    Thanks for rough estimate of capacitor. Can I get the calculation for the accurate value of capacitor from any source ?

  • @akpuhamnnabuike5644
    @akpuhamnnabuike5644 3 роки тому

    Good One there. Well Explained.

  • @goldfish5606
    @goldfish5606 3 роки тому +1

    Thank you for making another good video. Could you make a video on float switch connected to a pressure pump and motor.

  • @jpvdsandt8320
    @jpvdsandt8320 2 роки тому

    Thanks to show as
    That refreshing my mind and what i mist
    I know and learning from a pro and how do you explaining to me is so wonderful thanks
    Go on with this greatest to helps the rockies thanks

  • @enzoenxo5061
    @enzoenxo5061 3 роки тому

    Wow it's useful ☺️ thanks for upload.

  • @watahyahknow
    @watahyahknow 4 роки тому

    interesting and verry usefull , i have a drillpress that i need a new condensator for this makes it easy to find the right one
    a few things i wonder about , does the voltage in the country matter when it comes to the amount of micro fahrad needed ?
    and if i have a 16 amp fuse at 220 volts i can use about 2500 watt safely (70 percent) without the fuse blowing as soon as you get a peak current draw at startup , will the wattage of the three phase motor be the same with this setup as it would in 3 phase or increase ?

  • @chrisbellis4762
    @chrisbellis4762 7 місяців тому

    Most Useful Thank you Regards Chris

  • @stratcastor8988
    @stratcastor8988 3 роки тому

    Hi Jean B, Your Great Video are gratefully appreciated...hope I can ask your opinion on Dc motor. Thank You & keep it up with your Brilliant Video!

  • @dodznb238
    @dodznb238 2 роки тому +1

    Hello my dear friend, thank you for this sharing, very informative like big, fully watched from philippines👍🤝🙏🏼👏👇🏿👇🏿👇🏿👇🏿

  • @oscarvalenzuela262
    @oscarvalenzuela262 2 роки тому +1

    great!! thanks for sharing!!

  • @benohsten9323
    @benohsten9323 Рік тому +6

    When the motor is running, use a meter to measure the voltages between the windings. Change the size of the capacitor to achieve similar values between windings.
    Incorrectly sized capacitors can cause high voltages and damaged windings. When you have balanced the voltage across windings, like Jean said, it may be necessary to switch in
    an additional capacitor to provide sufficient starting torque. Like Tamas said, motor will not achieve its rated power. I need to check how this modification will effect RPM.
    Leave the terminal links in delta as at the beginning of the video. Just move neutral to the other side of the capacitor to reverse rotation.
    As per A I Reid below - use an inverter for best results !

    • @chagaarbellal4983
      @chagaarbellal4983 4 місяці тому

      I bought 25ùF for 0.37 kw
      It's the right one ?
      And can i connect in star winding? Without losing power?

  • @elmultimediaschoolofartscu3924
    @elmultimediaschoolofartscu3924 8 місяців тому +1

    Thanks a lot, you are the best

  • @eriknelson5886
    @eriknelson5886 4 роки тому +5

    thank you for the knowledge. great video. only criticism i have is the capacitor wire you connected to U2 was wrapped on the post backwards. being an electrician you should always wrap the wire clockwaise so when you tighten the nut down, it will tighten on the wire and not try to push it out.

  • @lawrencedhimz6194
    @lawrencedhimz6194 3 роки тому

    Thanks for the video👍

  • @v.stechnicalwork950
    @v.stechnicalwork950 Рік тому +2

    Very nice video..,., excellent 👌

  • @bucky2292
    @bucky2292 4 роки тому

    good presentation !!

  • @jaibengalurubengaluru4671
    @jaibengalurubengaluru4671 4 роки тому +1

    wow...very simple explanation....

  • @AxolotlCreamLeaf
    @AxolotlCreamLeaf 4 роки тому +1

    I have a Cleveland steamer with three phase but I only have single phase, what kind of capacitor should I buy? It is 208v three phase

  • @FeetoyBros
    @FeetoyBros 3 роки тому

    nice video sir. helped me to answer my exam

  • @sparked6886
    @sparked6886 4 роки тому

    Thats cool, thank you.

  • @better_house_plan
    @better_house_plan 4 роки тому

    if i have a 3phase motor with a power of 7.5k.. my asks.. can run it over single-phase as the method you explained.. even this motor need more torque for starts because it works on a cement mixer.

  • @leviesterhuizen9861
    @leviesterhuizen9861 2 роки тому

    Don't know if I am using the wrong capacitors or what could be the problem and I'm plugging into my wall plug that's 30A should I run it from main box, the fan makes as if it wants to start then it just humz then when you put it of you can see it stops

  • @joyal1213
    @joyal1213 3 роки тому +3

    Can we get 120 degree phase difference between the terminals in this method?

  • @evrenforest2578
    @evrenforest2578 4 роки тому +5

    Hi, this trick works for shot term. If you run your motor for an hour or two you will definitely fry it. Use a frequency converter or disconnect the capacitor with a simple switch right after the full revolution of the motor.

    • @orastojames7468
      @orastojames7468 3 роки тому

      Probably the capacitor used there is for running, if it were for the starting it won't even start remember a this is a three phase motor.

  • @OKVanAutoUpholsteryBellGardens
    @OKVanAutoUpholsteryBellGardens 3 роки тому +1

    What type of resistor do I need if my motor spec sheet only gives the following : amps on lo voltage (220) 8.6 amp, cycles-60 , 3 phz motor.

  • @niharranjanpradhan8633
    @niharranjanpradhan8633 4 роки тому +1

    Very good useful data

  • @WangleLine
    @WangleLine Рік тому

    Thanks a lot!

  • @maxwang2537
    @maxwang2537 3 роки тому +1

    Thanks for sharing. One question, is there a kw range that this method can be used (not outside)?

    • @EV1L1369
      @EV1L1369 3 роки тому

      Or maybe HP ranges

  • @sly_fox8261
    @sly_fox8261 4 роки тому

    Good Job!

  • @charlesmwangi164
    @charlesmwangi164 3 роки тому

    His demonstration is good

  • @iareid8255
    @iareid8255 4 роки тому +19

    If you need to run a three phase motor on single phase, get an inverter drive. This is an effective way and you will not lose any power as running on just single phase does. You get the extra benefit of speed control and inherent overload protection.
    While the above will run it's not good practice.

    • @octymocty132
      @octymocty132 4 роки тому +1

      @KC JONES
      It's called a Vfd ( variable frequency drive on e-bay 80 quid in uk )or more common an inverter but proper inveters still use 3phz to supply
      Still need to be careful full as they Chinese and not all termination is correct you do need to understand electrical drawings if as if ya poke n hope you'll blow it and you up
      I had one was ok till got pinched had it running of a generator as well so full 3phz portable set up

    • @freddokuckelmann8502
      @freddokuckelmann8502 3 роки тому +1

      WE DON'T CARE GOOD PRACTICE OR NOT. IMAGINE YOU ARE IN A JUNGLE, YOU NEED TO RUN THIS MOTOR IN ORDER TO SAVE LIVES. HE DID A GOOD JOB, STOP CRITICISING TO SHOW OFF

    • @iareid8255
      @iareid8255 3 роки тому +2

      Freddo,
      we are not in a jungle.
      My advice was to give the best outcome and have a reliable machine that will work as designed. Bodging a three phase supply this way reduces power dramatically.

    • @fvrrljr
      @fvrrljr 10 місяців тому

      @@freddokuckelmann8502 *EXACT-A-MUNDO*
      reminds me when on a date my car's alternator gauge said zero volts. popped the hood no alternator belt, told girl "i need your panty hose" (they were stockings) long story short she was shocked, i ripped them off used as alternator belt... 3 years later became my wife for the next 20 yrs. point is when in *dire straits* we do what we got to do to get the job done. it's money for nothing and chicks for free plus my MTV

    • @fvrrljr
      @fvrrljr 10 місяців тому

      @@freddokuckelmann8502 *EXACT-A-MUNDO*
      reminds me when on a date my car's alternator gauge said zero volts. popped the hood no alternator belt, told girl "i need your panty hose" (they were stockings) long story short she was shocked, i ripped them off used as alternator belt... 3 years later became my wife for the next 20 yrs. point is when in *dire straits* we do what we got to do to get the job done. it's money for nothing and chicks for free plus my MTV

  • @parvezkhan5849
    @parvezkhan5849 4 роки тому +1

    Thank you sir..

  • @andrevdm6406
    @andrevdm6406 4 роки тому +7

    Hi... very informative.. i received a 3ph induction motor which was modded to run off 1ph but i see no cap and direction can be changed/chosen by hand spinning when startup... is it because of missing cap?

    • @p0we111
      @p0we111  4 роки тому

      Hi Andre.
      Yes I will say that it is because there is no cap.

    • @josedelfino3331
      @josedelfino3331 2 роки тому

      You are running in two phase. Cause your motor is 3phase. One phase is missing. Running this motor continuously, you will cause overheating and burn the motor winding. That is why you need this capacitor to compensate the missing phase in order to assist the missing phase voltage supply to the motor, and ease the torque rotation of the motor.

  • @edwinokello4690
    @edwinokello4690 2 роки тому

    Great ,but does the power and speed changes

  • @zubairyamin6044
    @zubairyamin6044 2 роки тому

    that is a useful video thanks sir

  • @TonyPret
    @TonyPret 4 роки тому +3

    Hi, thanks for the show. Question. Maybe you can show us how to run a three phase AC off 24v DC battery?

    • @salle6307
      @salle6307 4 роки тому +5

      Without inverter, its impossible.

  • @stuarth43
    @stuarth43 3 роки тому

    great, what would be max size motor one could change, very interesting

  • @harrytopia282
    @harrytopia282 2 роки тому +18

    He just wired it wrong for reversing that motor, it will work but half the power of the other direction because he wired as delta for one direction and star for the other, the wiring is the same before but swap the phase and capacitor connection, now you have reversed the motor with the same torque, the capacitor value is approximately 8uf for every 100 watt of motor power, eg 60uf 1hp or 750watt motor.

    • @thebigblackguy
      @thebigblackguy Рік тому +3

      Thank you. I thought the same, just swap contact points 👍🏾

  • @leviesterhuizen9861
    @leviesterhuizen9861 2 роки тому

    How is it Jean B I have a 3 phase fan that I connected according to your video but the fan is just humming but not running I don't have a lot of info on the fan because no specifications on the fan it's self wondering if you could help me

  • @jamalahmed4246
    @jamalahmed4246 2 роки тому +1

    Thank you for your help me👍👍

  • @deanrowles3665
    @deanrowles3665 Рік тому

    so I have a 4kw 3phase motor, as far as the calculation goes the capacitor I need is a 280uf, to run 240v, have I got this right?

  • @honeybadgerdevelopments26
    @honeybadgerdevelopments26 2 роки тому

    thanks so much for this, please also consider doing a video on connecting a 3 phase inverter welder with single phase power

  • @chotuusian4127
    @chotuusian4127 10 місяців тому

    Good work👍

  • @davidreynolds3733
    @davidreynolds3733 2 роки тому +1

    Yes, to reverse simply move Live wire from U1 to W1 and move the wire of the capacitor from V2 to W2 and the motor torque is maintained. working from his diagram at 4 Mins. 16 sec, in.

  • @vincentstephen7821
    @vincentstephen7821 Рік тому +1

    Thank you for the expa

  • @ryansardjoemissier5430
    @ryansardjoemissier5430 3 роки тому

    Yesssss. Tanking youu

  • @naufalghani1383
    @naufalghani1383 4 роки тому +3

    Hi,
    Thank you for the video. It is very informative.
    I did follow your step and it worked. But later the motor wont start anymore.
    Is it because the capacitor or what?
    Does the capacitor needs to be recharged or not?
    Please reply me.
    Thanks!

    • @p0we111
      @p0we111  4 роки тому

      Hi Naufal
      If the motor is making a noise as if it wants to start then it might be the capacitor that is faulty.
      It does not need to be charged. It either works or fails.
      It might be the motor as well. A coil that fails can cause a motor to stop working completely.
      If you're lucky it could just be a loose wire...

    • @naufalghani1383
      @naufalghani1383 4 роки тому

      @@p0we111 Ok, thank you for your reply!
      Much appreciated

    • @galihtanu
      @galihtanu 4 роки тому

      Test capasitor pakai multi meter. Jika short atau putus ganti. Gunakan kapsitor non polar dgn teh kerja diatas tegangan jala2.

  • @glennlopez6772
    @glennlopez6772 2 роки тому +3

    It would be nice if the diagram was a circuit diagram, also showing the alphabetic letters as they appear on the terminal box!
    Thanks for the video well done!

    • @p0we111
      @p0we111  2 роки тому

      Thanks Glenn Lopez for the comment! The crude diagram with the numbers as they appear on the terminal box start from 2:00.

    • @armandovanas4198
      @armandovanas4198 Рік тому

      @@p0we111 an how do you wire it up if you have a 6core wire

  • @hassansaeed8903
    @hassansaeed8903 3 роки тому

    Outstanding video

  • @basicmegs1967
    @basicmegs1967 4 роки тому

    thank you sir for this vidio..

  • @wallaceburjins6841
    @wallaceburjins6841 4 роки тому +6

    Good old south african booytjie. Thanx from PE

  • @CountryHouseIncubators
    @CountryHouseIncubators 2 роки тому

    I did this on a larger motor but the capacitor started blowing out a white smoke. Do you know why this might happen and also do i always need a capacitor?

  • @danielteyehuago1633
    @danielteyehuago1633 Рік тому

    Please when you look at the speed, will it be the same as compared to connecting it to a 3phase supply.
    Thanks

  • @hazzspecchannel
    @hazzspecchannel 3 роки тому +1

    Thank you boss

  • @saijuakshaya1983
    @saijuakshaya1983 3 роки тому +1

    Good information thanku

  • @noelchetcuti8207
    @noelchetcuti8207 2 роки тому

    I have a 1.8 kw pump three phase. Can l run it on single phase or its too big? And how big the capacitor?

  • @kapepalasunnie7850
    @kapepalasunnie7850 4 роки тому +1

    Hi Jean
    Can you upload a video about on a centrifugal switch of a motor

  • @McchesterMphande
    @McchesterMphande 5 місяців тому

    Well explained

  • @ottocoetzee1018
    @ottocoetzee1018 3 роки тому +1

    Can you swap the Capasitor wire from neutral to live teminal in the delta format to change te rotation?

    • @pipermania8732
      @pipermania8732 3 роки тому

      You are correct . It's that easy but he isn't aware so he changed the connection to star, which also changes the motor to a higher voltage thus causing it to loose considerable power though it's reversing . The last part of his video is wrong .

  • @sisandandoni5769
    @sisandandoni5769 3 роки тому +1

    Hi.
    How to model a single phase motor? Why it doesn't self excite?

  • @brianoneill350
    @brianoneill350 3 роки тому

    Thanks a lot for knowledhe

  • @mickeydee1410
    @mickeydee1410 3 роки тому

    Good info.

  • @user-cv1so5nd1t
    @user-cv1so5nd1t Рік тому

    What permanent capacitor should i get for 3kw motor

  • @aubreydebliquy8051
    @aubreydebliquy8051 2 роки тому +3

    @Jean B - Nice presentation style but you could simply move the neutral to the other size of the capacitor to reverse direction.
    Why conflate Star/Delta with direction change unless you are confused?

    • @CrapInHell
      @CrapInHell Рік тому +1

      Hi
      In the US we have 2 hots to make 220v. I have a neutral and 2 hots, where would I connect the 3rd wire (perhaps Delta with live, neutral, live, and then start capacitor between neutral and live?)? Thanks

    • @aubreydebliquy8051
      @aubreydebliquy8051 Рік тому +2

      ​@@CrapInHell (1) Connect the 3 links for delta configuration like in the video.
      (2) Connect the 2 hot wires to any two of the motor inputs. (3) Connect one side of the Capacitor to the third motor input. (4) Connect the other side of the capacitor to one of the hot terminals for one direction or the other hot terminal for the other direction.

    • @CrapInHell
      @CrapInHell Рік тому

      Thanks for the quick response!
      Do I not need to connect the Neutral line?
      Will it have enough power to just run with the start capacitor?
      Thanks again!

    • @aubreydebliquy8051
      @aubreydebliquy8051 Рік тому +2

      @@CrapInHell Leave the neutral open. I am assuming the motor is rated 220/400V, you have two hot phases 120 degree apart. We have single phase 220V hot and neutral 0V so its the same here except using the two hot phases instead of hot and neutral. The main thing is the voltage between the two wires is 220V

    • @CrapInHell
      @CrapInHell Рік тому +1

      Awesome. Thank you so much for your help, very much appreciated!!!

  • @cosmo-deceverlastingcoatings
    @cosmo-deceverlastingcoatings 9 місяців тому

    Thank you.

  • @danielteyehuago1633
    @danielteyehuago1633 2 роки тому

    Please how do you select your capacitor for such work.

  • @koktelici
    @koktelici 4 роки тому +10

    Keep in mind that this will always heat your motor up, no matter how good you size your capacitor.

    • @tuttebelleke
      @tuttebelleke 4 роки тому +3

      The cooling (most-times a fan) on nearly all motors is calculated for that (little) extra heat.

    • @pilot505
      @pilot505 3 роки тому +1

      thanks for the additional tip you good man

  • @Grimster8587
    @Grimster8587 3 роки тому

    Hi master, i have 220v, 1Hp, 60Hz, 3.65A. 10mfd is okay to use?

  • @mogandassutayakumar1198
    @mogandassutayakumar1198 14 днів тому

    For 4kw 5.5hp 50 hz 3 phase motor what size of capacitor should i use? Can you please advise 😊

  • @etiennedejager5821
    @etiennedejager5821 3 роки тому

    I got a 3phase motor, but there is only 3 wires and not 6. I wish to run it on a VFD with supply in single phase, but I wish to test the quality of motor before buying a VFD. How do you test it on single phase with only 3 wires?

  • @Blenbkuqi
    @Blenbkuqi 3 роки тому

    Nice video. How much power do they lose when you connect single phases? What about rpm?

    • @RayThackeray
      @RayThackeray 2 роки тому +1

      I would like to know this too please!

  • @AxolotlCreamLeaf
    @AxolotlCreamLeaf 4 роки тому

    I have Cleveland Steamer 208v three phase 16.3 kilowatts but I have single phase output. What kind of capacitor should I buy?

  • @Ragnar.Lothbrok.3.14
    @Ragnar.Lothbrok.3.14 3 роки тому

    Would it be possible to run really big motors, say 20-30hp like this? Is this connection hard on the motor over time?

    • @burnerjack01
      @burnerjack01 3 роки тому +2

      If it were the correct way to achieve this solution, nobody would ever spend money on phase converters.
      The "easy way" is *ALWAYS* the wrong way. In motors, as well as in life.

  • @nareshmutyala
    @nareshmutyala 3 роки тому

    nice work