How to run three phase motor with single phase Supply | Easy Explanation with Animation

Поділитися
Вставка
  • Опубліковано 27 січ 2025

КОМЕНТАРІ • 60

  • @jorgedaza4799
    @jorgedaza4799 2 роки тому +2

    What a beautiful video!!! thanks sir!!

  • @samuelramesh8621
    @samuelramesh8621 2 роки тому +1

    @IT and Automation Academy
    Good Job, great Animation

  • @akbarmahmood7587
    @akbarmahmood7587 7 місяців тому

    Beautiful explanation, good work

  • @geoffgeoff143
    @geoffgeoff143 Рік тому +5

    There is a very good reason why this is never done other than in a classroom demonstration.

    • @cvjeevan
      @cvjeevan Рік тому

      What is the best approach to get this done?

    • @rangerswing
      @rangerswing 7 місяців тому +1

      Care to mention why? Would be helpful to others

  • @ridingvenus
    @ridingvenus 5 місяців тому

    Basic not as indepth on how vfd as capacitor but seems accurate information.
    Thanks

  • @kiddiescorner0101
    @kiddiescorner0101 2 роки тому

    Good Model and Animation

  • @MyungYounElectronicsCoLtdDPS
    @MyungYounElectronicsCoLtdDPS 2 роки тому +2

    Thank you for your nice video. Additionally, DPS is very good item for running 3 phase motor from single phase. DPS is Digital Phase Converter.

  • @naileldarov1451
    @naileldarov1451 Рік тому

    Well explained, many thanks 👍😊

  • @bnee4313
    @bnee4313 Рік тому

    do we connect capacitor in series or parallel if two 70uf capacitor is used?

  • @Warrf
    @Warrf Рік тому

    I use a Rotary converter.
    My first one was made by Phoenix.
    It was very noisy and could barely start my direct drive machine.
    I now use a converter made by Kay industry.
    Not only does it start my machine in 2 seconds or less it’s incredibly quiet.
    Phase master check it out.

  • @allawanmusa4873
    @allawanmusa4873 2 роки тому

    Thank you!

  • @allchinamachinery770
    @allchinamachinery770 11 місяців тому

    nice video

  • @khani-marwat8835
    @khani-marwat8835 2 роки тому

    Great

  • @mdkaisarahmad3924
    @mdkaisarahmad3924 2 роки тому

    Wonderful

  • @sambathbunkh
    @sambathbunkh 11 місяців тому

    Very useful video but how to calculate the capacitor size that's enough to use with 3phase motor? Thanks

    • @shadowwalker4633
      @shadowwalker4633 Місяць тому

      Dont even bother this method ll just kill your motor better just run a long cable to any other phase lol, this shifts phases to 90 degrees so not 120 , you would need a single phase with a voltage of 162.6 Volts to reach the 230V line to line

  • @hughleyton693
    @hughleyton693 Рік тому +1

    Yes, correct, you can drive a 3-phase motor using a Capacitor like that. . . . BUT the value of the Capacitor will only be correct for one size of motor and also for only one specific speed or Power output on that motor.. . . These days, it would be better to get a VFD drive unit, which can change single-phase to 3-phase.

    • @ITandAutomationAcademy
      @ITandAutomationAcademy  Рік тому

      True thats best way totally agree

    • @Flordelino-hf1nu
      @Flordelino-hf1nu Рік тому

      I wonder what would be the power rating of this kinda motor.
      Is it 5hp or what...? 🤔

    • @hughleyton693
      @hughleyton693 Рік тому

      @@Flordelino-hf1nu I am really not sure, at a guess, if the capacitor is sized correctly, you might get 3HP, probably less.

    • @Ratridez
      @Ratridez 9 місяців тому

      VFD are no good for a milling machine with multiple motors , rotary is the only way to go .

    • @hughleyton693
      @hughleyton693 9 місяців тому

      @@Ratridez VFD is good for any and all motors. . it just comes down to best cost consideration, balanced against the advantages of VFD. . . In fact, I suspect VFD would be very good for milling machines. . . Better starting with higher torque, and better coordinated control of speed.. . . What do you think VFD is. ?. . . It is much better control of rotary motors, than DOL.

  • @prabhakaran3324
    @prabhakaran3324 2 роки тому

    👍👍👍 thanks sir

  • @azzddine1033
    @azzddine1033 Рік тому

    hello, I have a qst , can i connect a single phase with a 3-phase machine (the machine contains stepper and servo motors and other devices) using the VFD technic. thank you.

    • @Ratridez
      @Ratridez 9 місяців тому

      No you can't , they're hp rated and no good for a mill , can't handle power spikes , rotary converter is the way to go . I've been doing this for years . I've built my own 10 hp converter and can run a 5 hp mill and a 3 hp lathe at same time no problem .

  • @martinho53
    @martinho53 3 місяці тому

    👍❤

  • @romeomarcelo6649
    @romeomarcelo6649 2 роки тому

    What is the capacitor value of 3 phase 7.5 HP motor plug into single

  • @pankajwarkade7321
    @pankajwarkade7321 2 роки тому

    Sir please make video on scada to plc interface?

  • @fahimginnah52
    @fahimginnah52 2 роки тому

    Please make for servo drive setting

  • @hilarydegale446
    @hilarydegale446 Рік тому

    Can i Buy one

  • @fidelcarlos9526
    @fidelcarlos9526 2 роки тому

    17uf/kw?

  • @mihaiciurdea4182
    @mihaiciurdea4182 6 місяців тому

    Doream o traducere Romana.

  • @SolarHarvestSolutions
    @SolarHarvestSolutions 11 місяців тому

    It wasn’t designed for this, I see motor failure under normal conditions sooner than later. One set of windings are doing more work…just like dropping a phase….not good

  • @shadowwalker4633
    @shadowwalker4633 Місяць тому

    Easier to just run a long cable to your main board lol

  • @ASHENTMAZABUKA
    @ASHENTMAZABUKA 3 місяці тому

    Where is neutral supply

    • @scottjobin7121
      @scottjobin7121 Місяць тому

      If it's a balanced load like a motor a neutral is not always needed.

  • @allawanmusa4873
    @allawanmusa4873 2 роки тому

    Hi

  • @Ratridez
    @Ratridez 9 місяців тому

    Rotary converters are cheap to build .

  • @KorisnikBr1
    @KorisnikBr1 Рік тому

    That's DC capacitor but it says vac...

  • @bigbothoee8617
    @bigbothoee8617 Рік тому +1

    Not a good explanation on rotary converter

  • @mrmaggiore817
    @mrmaggiore817 2 роки тому +2

    Not recommended