Tektronix TDS 784A power supply and channel 4 repair

Поділитися
Вставка
  • Опубліковано 2 тра 2020

КОМЕНТАРІ • 9

  • @joelkist6493
    @joelkist6493 2 місяці тому +1

    Nice work!

  • @thetechgenie7374
    @thetechgenie7374 5 місяців тому

    Higher ESR means DC leakage as the component tester give higher ESR as takes longer to charge.

  • @t1d100
    @t1d100 2 роки тому +1

    Excellent repair. Thank you for sharing.

  • @rollinhand4750
    @rollinhand4750 4 роки тому

    Fantastic video keep it up

  • @alexarif2835
    @alexarif2835 2 роки тому +1

    My scope (TDS-784c) has a strange issue, any advice where to look ?When I connect the scope to the Mains or use the back plate power button it allows me to switch it ON from the push-button in front. However if I switch if off and leave it off for a day then the push button in front doesn’t work anymore and I have to disconnect the mains first before I am able to switch it on again.
    I re-capped the Power Supply but the issue remains the same.

    • @mymessylab
      @mymessylab  2 роки тому

      Apologies for the delayed reply. The problem seems to be related to power supply however there’s a small push button onto the processor board that have the same function of on/off switch on the front panel. If also that doesn’t work seems that the PSU standby circuit is defective. There is a PSU schematic on the Web somewhere that will be of great help.

  • @TheHoss4145
    @TheHoss4145 4 роки тому +2

    inductor