Розмір відео: 1280 X 720853 X 480640 X 360
Показувати елементи керування програвачем
Автоматичне відтворення
Автоповтор
thank you for this great work
Thanks you sir, that's video helpful for us
Man A & B i have good abillity in this system
I worked in the construction of two-stroke ships
i had the same problem on seatrial
the system that are you in charge is AT 3000 ?
thanks
So as far as I understood ( because I'm not electrical engineer), this level sensor has input signal from MPC - 24 volts and output signal from sensor -4.8, correct?
@@MaxKharevsky yes, you got it
The best !
Thank you
Good day sir! What’s the normal dc voltage measurement during cylinder injection test must be?
as per our observation, Input voltage is 23- 24vdc, output is 4.3-4.8vdc the sensor will be in normal condition.
@@DinhSonVu-uz4zb thank you!!!
Thank you sir!!
the vedia came late to me
thank you for this great work
Thanks you sir, that's video helpful for us
Man A & B i have good abillity in this system
I worked in the construction of two-stroke ships
i had the same problem on seatrial
the system that are you in charge is AT 3000 ?
thanks
So as far as I understood ( because I'm not electrical engineer), this level sensor has input signal from MPC - 24 volts and output signal from sensor -4.8, correct?
@@MaxKharevsky yes, you got it
The best !
Thank you
Good day sir! What’s the normal dc voltage measurement during cylinder injection test must be?
as per our observation, Input voltage is 23- 24vdc, output is 4.3-4.8vdc the sensor will be in normal condition.