How to Change MPC of ME- C Man B&W ships MAIN ENGINE

Поділитися
Вставка
  • Опубліковано 13 бер 2024

КОМЕНТАРІ • 4

  • @singhraju4000
    @singhraju4000 4 місяці тому +1

    Good day brother, In future do not switched OFF the power supply breaker of the any MPC while replacing with new MPC . Be careful about the power supply of the Angel Encoder TSA A and TSA B. If you switched OFF the power supply of the Angel Encoder than Main Engine will not start even though it can not blow through also.( It's happened with me 🤣🤣 .The vessel was in port and I was tracing the electrical noise means 24 volts low insulation. I alternate switched Off the power supply breaker of UPS A and UPS B breaker off the MPC. After switch ON power supply all MPC working very nice but Main Engine can not below through also. It's take me about 2 hrs than I found that TSA A and TSA B indication light was missing. Than I engaged the turnning gear and I rotate the fly wheel up to 360 dgeree and after that I left the fly wheel at TDC position where the TSA A angle Encorder light was ON. After that we try to below through the Main Engine and got the success) Thanks for sharing the your knowledge👍👍.

    • @etomehra
      @etomehra  4 місяці тому

      Thank you so much will take this feedback as a Note

  • @igortabulynsky2253
    @igortabulynsky2253 4 місяці тому +1

    it would be informative to see a list of alarms on the MOP panel... until the MPC board is changed. Brgds

    • @etomehra
      @etomehra  4 місяці тому +2

      Thanks for watching ,Appreciate you comment, will take care in my next video