How to find the column size | How to calculate the load on column | Initial size of column | Column

Поділитися
Вставка
  • Опубліковано 1 гру 2024

КОМЕНТАРІ • 100

  • @CivilEngineeringMastery
    @CivilEngineeringMastery  5 місяців тому +1

    It will be 0.008Ag instead of 0.08Ag @ 12.16.
    Only to find out the gross area we use the formula 0.008Ag. So the gross area will become 23809.52mm^2 and d=23809.52/240 = 99.206 mm instead of 34.04 mm. This is to check the depth of the column. It was an error by mistake. Sorry for the inconvenience.

  • @ErsriyaVikash
    @ErsriyaVikash 9 місяців тому

    This is a very beautiful video which clearly shows the load on the column and has a lot of information related to the building.

  • @ibrahimansari9966
    @ibrahimansari9966 6 місяців тому +1

    Very clear ❤ all concepts are define very well

  • @vigneshvicky8239
    @vigneshvicky8239 4 місяці тому +1

    Thank you so much for giving detail explanation

  • @joshuvabanjar7887
    @joshuvabanjar7887 11 місяців тому +1

    very nicely explained ma'am thankyou

  • @rajanv.m.8136
    @rajanv.m.8136 2 роки тому +1

    It will be better to consider 3 bays along X axis and 2 bays along Y axis with G plus 3 floors will be good to explain to arrive size of column.In addition to this thumb rule followed in practice also useful to assume size of column initially.
    Thank you for explaining neatly with sketch with detailed calculation.

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  2 роки тому

      Thank you.
      Please refer to the below link for load calculation of G+2 building part-1
      ua-cam.com/video/q8-puhJThI4/v-deo.html
      Part-2
      www.youtube.com/watch?v=XSptm...
      Part-3
      ua-cam.com/video/7cpyZ8S666E/v-deo.html
      Part-4
      ua-cam.com/video/0RXEcu5URYo/v-deo.html
      Part-5
      ua-cam.com/video/vjSE1W3tgvE/v-deo.html

  • @SutharAnil07
    @SutharAnil07 7 місяців тому

    Superb 👌👌 And useful video for structural designing👍

  • @robbiecrawford4345
    @robbiecrawford4345 9 місяців тому +1

    This is an amazing ppreseentation

  • @russmancherose6946
    @russmancherose6946 Рік тому

    Thank you.. Good explanation for new student as l am.

  • @sofroniocarranza6064
    @sofroniocarranza6064 Місяць тому

    Hi morning this is useful to everyone who seen it

  • @ibnadam9964
    @ibnadam9964 7 місяців тому

    Short ,brief, very nicely explained❤

  • @PankajSingh-me4th
    @PankajSingh-me4th Рік тому +3

    This video is too good

  • @xaviourxaviour6626
    @xaviourxaviour6626 Рік тому +2

    Very good

  • @surajprajapati6009
    @surajprajapati6009 2 роки тому

    Thank You Very Much maam for so detailed explanation 🙏🙏🙏

  • @SherazAkram-bp9dq
    @SherazAkram-bp9dq 8 місяців тому

    so much help full video thanks

  • @sulaikhakh8219
    @sulaikhakh8219 2 роки тому +3

    In roof beam load calculation, self weight of beam is not added to self weight of parapet. Considered 6 kn /m only.
    . Please correct me if iam wrong

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  2 роки тому +3

      Yes, you are right. self-weight of the beam needs to be added with the self-weight of the parapet wall which is 2.81 + 6.0 = 8.81 kN/m.
      It was an error. Kindly ignore and thanks for the notification.

  • @kafoodvlog174
    @kafoodvlog174 2 роки тому +2

    Slab load will act on beam like triangular motion only..but you consider like square motion, can clarify regarding this??

  • @GautamRout-mz1mj
    @GautamRout-mz1mj 6 місяців тому

    Very well explained. What if mam it is a uniaxially or biaxially loaded ?

  • @rajanv.m.8136
    @rajanv.m.8136 2 роки тому

    Similar to explain by madam you can calculate load on column for vertical load (DL+LL) for typical 2 or 3 columns by using tributary area method.
    Multiplying factors
    1. For beam spans up to 6.0m multiply by 1.2 and for beam spans greater than 6.0m multiply by 1.30 to arrive gravity loads.
    2. Multiply 1.3, 1.4 and 1.5 for EQ zones 3, 4 and 5 respectively for including seismic loads.
    By considering first floor steel as 2.50% determine size of column for assumed concrete grade and steel grade from formula Pu=0.4fck Ac+0.67 fy Asc. MInimum size of column as per IS13920-2016 will be 300mm or 20x beam dia bars assumed.This will be followed by Architect for arriving preliminary size of rcc column in building design.
    This is suggestion. Thank you

  • @hinaajannabum3871
    @hinaajannabum3871 25 днів тому +1

    Pl upload for beam design also

  • @dinushakarunaratne4344
    @dinushakarunaratne4344 Рік тому +1

    Can explain about is this a one way or two way slab?

  • @SanjayKR-ie8wo
    @SanjayKR-ie8wo Рік тому +1

    Why you take Asc as 0.08ag ?

  • @PankajSingh-me4th
    @PankajSingh-me4th 2 роки тому +1

    Love this

  • @dawon7750
    @dawon7750 Рік тому

    I think you have to explain how did tou arrive the load of floor finish to 1.5 kN/m2 , the live load, and the 25 that you multiply to the thickness of the slab. We have to know it by your explaination. Whare did you get them, and or how did you determine it? Its not just enough to introduce it, but how come?

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  Рік тому +2

      Floor finish thickness 75mm, unit weight of floor finish 20 kN/m3.
      0.075 x 20 = 1.5 kN/m2.
      Unit weight of RCC is 25 kN/m3. This has to be multiplied with the thickness of the slab to get the self weight of the slab.
      Live load need to be considered as per IS-875-Part-2.

    • @dawon7750
      @dawon7750 Рік тому

      @@CivilEngineeringMastery Thanks a lot my dear Sir. Now i know it.

  • @BestWayMotors2004
    @BestWayMotors2004 Рік тому

    thank you so much mam

  • @elliotfamutimi9776
    @elliotfamutimi9776 Рік тому +1

    I will like you to make a video of design of a primary with a secondary beam attached to the primary beam making the primary beam to have an additional point load from the secondary beam to the UDL of the secondary beam

  • @anuanas1582
    @anuanas1582 Рік тому +1

    Madam vedio is good, please vedio few slowly is better

  • @SanjayKR-ie8wo
    @SanjayKR-ie8wo Рік тому

    How you taken area of steel as 804 mm^2 when finding load bearing capacity of column.

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  Рік тому +1

      The required steel area was 720 mm^2, whereas the provided steel is 4T16, so the provided area is 804 mm^2. The area of one 16mm bar is 201mm^2.

  • @vijayashalini3700
    @vijayashalini3700 2 роки тому

    Thank you so much madam 🙏🙏🙏

  • @duncanwasike9549
    @duncanwasike9549 7 місяців тому

    How did you get the 804mm² area of steel?

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  7 місяців тому

      804mm^2 is the area of steel provided. 4 nos of 16mm (4T16) dia bar provided, if you calculate the area that will come to around 804mm^2.

  • @sumanbaroi38
    @sumanbaroi38 2 роки тому

    How will I find the foundation depth? Please Make a video.

  • @leonardofetalvero6942
    @leonardofetalvero6942 Рік тому +1

    nice topic

  • @Tear_12
    @Tear_12 2 роки тому

    Thanks

  • @pete_surgeon
    @pete_surgeon 8 місяців тому +1

    Discuss beams.

  • @SanjayKR-ie8wo
    @SanjayKR-ie8wo Рік тому

    What is ( 4 T 12 ) or ( 4 T 16 )
    How you taken area of steel as 452mm^2 or 804mm^2
    Please explain.

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  Рік тому +2

      4 T 12 - 4 nos of 12mm dia bar. 4 T 16 - 4 nos of 16mm dia bar.
      The area of one 12mm bar is 113 mm^2, Area of 4 T 12 is 452 mm^2.
      The area of one 16mm bar is 201 mm^2, Area of 4 T 16 is 804 mm^2.

  • @muranoaydnlatma1395
    @muranoaydnlatma1395 5 місяців тому

    Dear Ms. Architect, you explained it very well, thank you very much for your valuable lesson video.
    Are there earthquake and wind loads in the calculations explained in this video?
    Thank you very much.
    Hakan

  • @solomonbayisa2138
    @solomonbayisa2138 2 роки тому

    good

  • @bharathrambabu
    @bharathrambabu Рік тому

    Madam you forgot to say about how to calculate the lateral ties dia

  • @apurbasulekhaconstruction1519
    @apurbasulekhaconstruction1519 2 роки тому

    Mam I have column to column distance 12.10 feet span for g+1 building i have use 4 T12 for column .Can it be safe

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  2 роки тому

      Please check what is the load coming on that column and adequate size is provided or not and then check this reinforcement is suffice.

    • @Mzk-mf1fx
      @Mzk-mf1fx 11 місяців тому

      Just increase the no. Of stirrups rings along to suffice column strengthen

  • @CORNERSTONE-CONSTRUCTION
    @CORNERSTONE-CONSTRUCTION Рік тому

    IS THE LOAD CALCULATION OF SLAB IS CORRECT?

    • @krishnakumar-vi6wj
      @krishnakumar-vi6wj 11 місяців тому

      Only the calculation of slab is wrong and you identified that

  • @himanshusonone494
    @himanshusonone494 Рік тому

    In load for second floor why self weight of beam and parapet wall weight is not add.

  • @RambhajanGupta-n5q
    @RambhajanGupta-n5q 5 місяців тому

    .008g ki jagah .08g likha hai formule mein , isliye 34.04mm column ki one arm ki length aayi hai.weight mein kn kya hai?

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  5 місяців тому

      Thank you for the notification. It was an error. Sorry for the inconvenience. It will be 0.008Ag instead of 0.08Ag @ 12.16.
      Only to find out the gross area we use the formula 0.008Ag. So the gross area will become 23809.52mm^2 and d=23809.52/240 = 99.206 mm instead of 34.04 mm. Other than this everything will be ok. This is to check the depth of the column. Hope this helps.

  • @SanjayKR-ie8wo
    @SanjayKR-ie8wo Рік тому

    While calculating Pu you take equation 300X10^3.
    Why you take like that pl kindly tell us.

  • @syedmuzammilhussain9505
    @syedmuzammilhussain9505 2 роки тому

    At last moments while calculating the area of column
    I.e, Pu...
    Why you added 10^3 in the equation?
    300×10^3.....!!!???
    I didnt understand that

  • @arunkumargupta5890
    @arunkumargupta5890 2 роки тому +1

    Excellent

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  2 роки тому

      I have created a course, structural design of buildings using Etabs software which includes structural analysis and design of a five-sorey RCC building(Real project) and is now available on udemy.
      Kindly use the below link to avail the full course.
      www.udemy.com/course/structural-design-of-buildings-using-etabs-software/?referralCode=14883FDBBD95A1ADAC02

  • @sachinpal-gs9cs
    @sachinpal-gs9cs Рік тому +1

    Area of Steel kase aaya mam

    • @sachinpal-gs9cs
      @sachinpal-gs9cs Рік тому

      Please reply

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  Рік тому

      The area of steel has to be calculated as per the % of steel which is given in IS-456:2000.
      For columns % steel is 0.8 to 6.0%.

  • @naruto____haikyuu4678
    @naruto____haikyuu4678 Рік тому

    How did u derived Ac =0.992

  • @yunus-YA
    @yunus-YA Рік тому +1

    Sis 0.8% in calcuion is 0.08which is 8 %insted of .8 pls explain

  • @emmanueladeniji9096
    @emmanueladeniji9096 Рік тому

    I feel like subscribing thrice after watching this. Can someone help me out?

  • @piyushsharma7933
    @piyushsharma7933 2 роки тому

    Niceeeeeee explain mam

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  2 роки тому

      Thank you.

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  2 роки тому

      I have created a course, structural design of buildings using Etabs software which includes structural analysis and design of a five-sorey RCC building(Real project) and is now available on udemy.
      Kindly use the below link to avail the full course.
      www.udemy.com/course/structural-design-of-buildings-using-etabs-software/?referralCode=14883FDBBD95A1ADAC02

    • @anuanas1582
      @anuanas1582 Рік тому

      Madam please contact number

    • @anuanas1582
      @anuanas1582 Рік тому

      I am a diploma in civil engineering. Me any helpful this course

  • @arijitdutta2102
    @arijitdutta2102 9 місяців тому

    YOU FORGOT TO ADD THE SELF WEIGHT OF 2ND FLOOR BEAM AND SELF WEIGHT OF PARAPET WALL COMING ON COLUMN C1. AFTER ADDING THOSE TWO THE TOTAL LOAD WILL BE {(2.81+6)X3.35}/2 = 14.75KN

  • @INDIAmeansBHARAT1950
    @INDIAmeansBHARAT1950 Рік тому

    How we can contact u...

  • @eringufrancis3128
    @eringufrancis3128 2 роки тому

    Load on column

  • @surajprajapati6009
    @surajprajapati6009 2 роки тому +1

    I have a doubt maam that 0.8% should been written at 0.008 na

  • @KManas-mh7hy
    @KManas-mh7hy Рік тому

    Madar there are 2 mistakes