Dryer Receptacle Wiring

Поділитися
Вставка
  • Опубліковано 4 жов 2024
  • If you want to help support Shannon to produce more videos like this, visit www.house-impr...
    Shannon from www.house-impr... shows you how an electric dryer receptacle is wired.
    If you have questions about your home improvement projects, stop by the forum on our website, where Shannon will answer your questions in detail for free.
    Website: www.house-impr...
    Facebook: / 180657245288627
    Twitter: / house_improve
    Video © 2017 SKS Media. Videos produced by SKS Media (House-Improvements.com) are provided for informational purposes only. The information contained in the videos is intended to give general guidance to simplify DIY (do it yourself) projects. Because tools, products, materials, equipment, techniques, building codes and local regulations are constantly changing, SKS Media cannot and does not assume any responsibility or liability for the accuracy of the information contained therein. Further, SKS Media will not accept any claim for liability related to, but not limited to, omissions, errors, injury, damage or the outcome of any project. It is the responsibility of the viewer to ensure compliance with all applicable laws, rules, codes and regulations for a project. The viewer must always take proper safety precautions and exercise caution when taking on any project. If there are any questions or doubt in regards to the element of a project, please consult with a licensed professional. SKS Media conducts all matters in accordance with the laws of Saskatchewan, Canada.

КОМЕНТАРІ • 135

  • @JHStretch
    @JHStretch 3 роки тому +12

    For all you homeowners going through so many trash videos by trash contractors, this guy is one of the best I've seen! No I'm not his buddy, but I am a pain in the ass contractor that is always trying to recommend videos for DIY homeowners, and I definitely recommend this guy. Not a hack!

    • @HouseImprovements
      @HouseImprovements  3 роки тому +1

      I appreciate your recommendations.

    • @ClaudiaIhl-r6m
      @ClaudiaIhl-r6m 4 місяці тому +1

      I agree. I've watched many of his vids and they have helped my greatly in my DIY adventures. Plus he has a very pleasant voice....

  • @ajx1994
    @ajx1994 2 роки тому +2

    This guy's voice is so soothing to me, for whatever reason. I feel like I can handle any job that he describes because he says it so calmly. lol

  • @graemeroth7438
    @graemeroth7438 8 місяців тому

    Thank you! Has lots of videos everytime I need UA-cam help. He's my guy to answer all my electric and plumbing problems

  • @alexpadilla1784
    @alexpadilla1784 Рік тому

    Wow this is the first on UA-cam videos for me. I looked at it, simple no confusion, right to the point. To me and everyone I say how awesome is that it's the best. Like hitting the home run ball, it goes outside the fence on the first pitch at your little league baseball game. On top of that the crowd roaring for you. As in reading your positive feedback in the comments. Thank you for your video helping DIY's, thank you for keeping people safe.

  • @brianpiper3188
    @brianpiper3188 7 років тому +18

    Typically you use: 12 AWG for 20 amp, 10 AWG for 30 amp, 8 AWG for 40 amp, and so on. If you're wiring for a shop or location where large tools and compressors are used, I would recommend using the next gauge thicker than your needs (ex. use 8 AWG for 30 amp). This benefits you in two ways: 1 adds another level of safety (thicker wire and insulation) and 2 allows for easy 10 amp increase (heavier wire already installed, just change receptacle and double pole breaker). Wiring all 120v outlets in a house with 12 AWG gives you the same safety and capability to upgrade from 15 amp to 20 amp receptacles.

  • @vladster264
    @vladster264 2 місяці тому

    Thank-you very much😊. This is the video I have finally found, and been looking for. As when I soaked my dryer plug in 💦 & bleach the colour markings have been erased. Also, I appreciate the thorough explanation as I now understand dryer wiring basics- thank-you, useful information. 🤙

  • @danieldelewis2448
    @danieldelewis2448 6 років тому +9

    This guy does some great videos, on apparently everything

  • @rickbradley5373
    @rickbradley5373 2 роки тому +1

    Thanks for your video. I’m wiring a dryer this weekend

  • @bradlloyd358
    @bradlloyd358 4 роки тому +1

    So here I am wondering where the heck the black and red wires go ..... off to UA-cam and who is the first video on the list .... thank you for your videos - saved the day again!

  • @MenacingMoto321
    @MenacingMoto321 7 років тому +10

    Some of the best DIY videos on UA-cam, thanks.

  • @horrorman9
    @horrorman9 5 років тому +2

    Thanks. This video has been alot of help especially for those of us who live in older House's, and were never told that the wiring code was changed. Now you have to have that (L) shape receptacle in your laundry room.

  • @armandomenchaca4893
    @armandomenchaca4893 7 років тому +1

    you are better than this old house show, to me that is. i follow all your showe's, thanks

  • @Larry342516
    @Larry342516 7 років тому

    Great video Shannon. I do wish you would have shown how to hook it up to the receptacle box. I know how to do this, but thought it might be a big help for some of your viewers. Thanks again.

    • @MrBucidart
      @MrBucidart 7 років тому

      Good guys wear white hats, the white wire goes to the silver screw, the ground goes to the green screw and the black and red wires go to the copper colored screws. I always teach my men to attach the ground wire first on a install and the ground wire is the last wire to be disconnected on a replacement. Safety 1st.

  • @tintintintin232323
    @tintintintin232323 4 роки тому +1

    Thanks So Much! I couldn't figure the red wire black wire...machine is noiw werking…..a lifesaver!

  • @blubberywhale9247
    @blubberywhale9247 Рік тому

    god thankyou, finally someone explained it in a simple way i can understand, much appreciated

  • @jessemyers9858
    @jessemyers9858 4 роки тому +1

    this guy does the best videos on youtube

  • @tedlahm5740
    @tedlahm5740 2 роки тому

    10/3 with ground
    The orientation (pre thought) is obvious important. Thank you.

  • @dmp800
    @dmp800 4 роки тому +2

    I'm very thankful for your videos I'm getting ready to install a washer and dryer at home and i can definitely wire the recep for it thank you so much sir ,, keep making good videos!

  • @ajjmunoz
    @ajjmunoz 7 років тому +2

    So glad you're doing videos again. Thank you so much. LOVE your videos. Keep up the good work!

  • @keithsandercock1412
    @keithsandercock1412 3 роки тому

    Thank you. Thank you. Exactly what I needed to know about the X-Y connections!

  • @hayyanah1980
    @hayyanah1980 4 роки тому

    Thank you so much coz we moved our washer and dryer now we have to deal the wiring as well... thank you so much!

  • @luvkountry
    @luvkountry 3 роки тому +1

    The only real difference between the Stove Wiring and the Dryer Wiring is the wire gauges and the fuse amperage size. Is this correct? Thanks Shannon, Your videos are always very informative and I really enjoy watching them. Your professional advice is appreciated. thank you.

  • @albertramos6243
    @albertramos6243 2 роки тому +1

    I really like watching your vids, you know what your doing thank you!

  • @gregs7918
    @gregs7918 4 роки тому

    You always give the best answers. Thanks.

  • @getupandgo77
    @getupandgo77 7 місяців тому

    Thank you! very helpful

  • @tittyrino
    @tittyrino Рік тому +1

    You have helped me so much over the years Thank you and stay safe

  • @hernimnimeisa9776
    @hernimnimeisa9776 Рік тому

    Great information, thank you

  • @Kentucky-bz6pg
    @Kentucky-bz6pg Рік тому +1

    Can you run your 220 and your washer supply lines between the same studs? I’ve got a stacking unit and would like it all behind the washer/dryer tower.

  • @Riverside_Ranch
    @Riverside_Ranch 7 років тому +1

    Hey Shannon, first off thank you so much for posting your videos. I'm about to do a down to the stud renovation and your videos have been instrumental in giving me the confidence to take on this huge project.
    I want to drop a request to ya to make a video on painting vinyl siding. I need to move windows, make an addition, and replace some siding which will obviously not match and would like some tips on painting the siding to make it all one color. Thanks !

    • @tittyrino
      @tittyrino Рік тому

      What kind of siding ? Vinyl when painted will expand and contract showing the true colors when that happens. Best bet is to match the existing color best you can and go for it.

  • @donaldsaunders4736
    @donaldsaunders4736 Рік тому

    Great video well explained thank you

  • @richardbrown6087
    @richardbrown6087 2 місяці тому

    Well explained

  • @SomaElectricals
    @SomaElectricals Рік тому

    hi, i purchased LG dryer from USA, in USA there will be 120 volts 2 Phases and the dryer work in 240 volts, Now I'm in India, here we have 240 volts, 1 line and neutral, can you guide me how to connect the dryer in 240 volts.

  • @jeremyp245
    @jeremyp245 2 роки тому

    Mega helpful! Thanks for posting

  • @p165711
    @p165711 7 років тому +3

    If only you did this video 6 weeks ago. :-) Could have avoided the sparkies callout fee.

  • @greenearthblueskies8556
    @greenearthblueskies8556 3 роки тому

    I appreciate this...thanks

  • @wecharg
    @wecharg 2 роки тому

    After you put drywall over top, the screws for the clamp outside the box are no longer accessible, is this alright?

  • @jonienglish3231
    @jonienglish3231 4 роки тому

    VERY GOOD SHANNON

  • @BRICEN18
    @BRICEN18 2 роки тому

    Thank you!!

  • @dmp800
    @dmp800 4 роки тому +1

    Could you make another video on how to conect the other end to the braker box pls thank you!

    • @HouseImprovements
      @HouseImprovements  4 роки тому

      If you ask in our forum we can help you from there.www.house-improvements.com/forums/

  • @luvkountry
    @luvkountry 7 років тому

    I noticed a lot of or perhaps all newer air conditioner units have no provision for the condensation water to escape. I think they are depending on the heat from the unit to evaporate the water. Problem that we have found is : if you shut down the unit some of the condensation water remains on the bottom and does create mould so when you turn the unit back on it smells mouldy. The engineers of this type of unit weren't thinking too clearly when they designed these newer air conditioners.

  • @Geo35868
    @Geo35868 3 роки тому

    Thanks 🙂

  • @jamescc2010
    @jamescc2010 3 роки тому

    Do we need to go back and check dryer breakers on circuit breaker to see if it has ground wire coming out? We are buying 1987 condo and the dryer receptacle is 3-prong so we will have to replace it with 4-prong. Base on what electrician told me it should have ground for dryer breaker. This vid comes handy.

    • @HouseImprovements
      @HouseImprovements  3 роки тому

      My forum is the perfect place to get answers for questions like that and its totally free!www.house-improvements.com/forums/

    • @KevinCoop1
      @KevinCoop1 2 роки тому

      You probably have done what you needed. 1987 is iffy. That is about when the code change happened to install 4 wire. If you have a red wire in the box , then change the receptacle to 4 wire. If no red wire, then change the dryer cord and plug to 3 wire. Still allowed in NEC.

  • @dw4457
    @dw4457 4 роки тому +1

    Where u get that 2 Box Dryer Plug?

  • @ClaudiaIhl-r6m
    @ClaudiaIhl-r6m 4 місяці тому

    Question....if your house is generally wired for 110, can you have a new circuit installed for a 240 V dryer?

  • @kenmccarthyfishing
    @kenmccarthyfishing 4 роки тому

    The ground wire you you screwed into the box,is that also grounded in the breaker box also or just the metal box,I greatly could use your help 💪👊

  • @MrPeterpanpeter
    @MrPeterpanpeter 4 роки тому

    Great video👍

  • @jenraider72
    @jenraider72 6 років тому

    Thinking of doing this myself; seems that since my husband died and I've needed to hire pros for electrical, gutter repair and 3 days ago sidewalk patching- that I keep getting screwed over because I'm laid back and not clingy & let people work and seem an easy mark with no one at all giving me advice or help prior to hiring. I'm really shocked how those people had no problem doing sub par or less work than agreed upon and not caring or feeling any responsibility doing this to a widow with 2 kids & no help. Last guys were the worst; one of them told me before leaving how I was a "pleasure to work for...really" & his partner just wanted his cash after spending maybe half an hour just throwing mud down with a trowel before sun set since they spent most time working across strreet on stair job they picked up. Next day I see big sections never patched at all and one that he said was tougher because they had to "burn" the grass fist and use a diff mud that was left still unfixed as a triangular missing section of dirt with some sand laid down that was never finished. They were there and called me over since they were replacing neighbor's last sidewalk square that was broken up. Then my sidewalk begins and my late husband who was a very in demand mason foreman and fixed/ remodeled/did any & everything around the house meticulously & never used rock salt, told me to just lay out salt after shoveling and of course, it further damaged conglomerate. I think he just was so sick by then and on heavy meds and wasn't worrying about the damage it'd cause later- and who can blame him for that. So these guys said $500 for one square or they'd "do a nice job" just resurfacing it so people won't trip for $250. I took the $250 deal. Wasn't pretty but so what. There were large sections and smaller sections of my front walk and the guy offered to fix it the next day when he came back to do the other guy's steps. They talked and he said "we'll do it for $250 also, down to the end and if there's any extras we'll throw that in too for you". Cash only again. I agreed. Next day he arrives at 10 am and now tells me that they would need a better mud for some areas and pointed out one of the grassy missing sections saying that was more work to "burn" the grass first then patch it and so he'll "do everything to the end for $150". I thought that was great, he's lowering price and did say for the whole length so I thanked him and agreed to have them do the work- again. Then 2 minutes later he recaps the offer and says the total will now be $400. The $150 was actually on top of the original price we agreed on the day before. So suddenly my price jumps from $250 to $400. I'm in and out during the day and they're always across street. I see at some point that they swept the smaller rocks and loose bits off the pavement. Mainly I notice this because my narrow curb section of grass is littered with all the white/black chunks and rocks that came from the sidewalk. Sometime after 6 I came home again and sat in my car for 45 minutes changing out some fuses and messing with wiring for rear dashcam. Just before I finish, I finally hear the trowel sounds as the main guy is hastily going over a section, as it will soon be getting dark. The guy tries to tell me my garage roof needs work- my husband had just redid it. He wants to buy my husband's truck that I keep but no one drives, then he wants the gas leaf blower he sees. Then other guy says wife/kids car died so he has to drive them so why don't I sell him my other just sitting there car- a 01 Malibu with only 50+K miles on it. Said my daughter may use it or I'd sell it for comparable cars' pricing. He pleads, "come on...sell me the car. I'll give you a couple hundred bucks for it". I say no way, not selling it that cheap since it was well maintained, one owner and low mileage. Other guy still wants blower, I ask how much & he doesn't say. Then I'm getting ready to pay them & he says," well then just throw us each a good tip" (I guess because he wasn't getting the truck or blower and other guy my car, hence I now owe a nice tip). Then I pay the other guy and of course I throw in an extra $40 tip. Other guy back and says or forget tip and just give me the blower, said something on it was blown too. I said just take it & said I had already given the extra tip. That's when guy tells me I was a pleasure to work for and call him if I will sell the car & think about it. Fine. I was stupid I guess, so be it. However, next day in am I can really see how little was actually done and how many bare chunks of broken off sidewalk are still unfixed, including the "special" section that caused price to jump $150. I'm hoping I can see which number was his on my phone and text photos asking if they'll do what they said they would when I accepted their price- twice. They were also supposed to leave a receipt in mailbox if I was not home, but I was & forgot to ask after all the car/truck/blower/nice tip pressure shit. Is this just how it is, or am I allowed to be upset and feel like I was screwed over for being too nice and naieve? Sorry so long, but I have no one to talk to so I guess I had to vent and tell someone. Thanks for taking the time...

    • @thereddstormproject1954
      @thereddstormproject1954 5 років тому

      jenraider72 damn that's alot

    • @anonymousbyproxy8250
      @anonymousbyproxy8250 5 років тому

      Jen, hopefully u're doing better. No need to hire anybody anymore. U tube has instructions on everything pertaining to house/home building and maintenance.

  • @patrickwilson4902
    @patrickwilson4902 3 роки тому

    I need to know what that Orange wire is is it at 10/3 or 10/4???
    What should I put

  • @rennyvangrieken2159
    @rennyvangrieken2159 4 роки тому

    Thanks Sir, but my house is an older house with only 3 wires, black white and ground. Does this mean that i must get wiring redone?

    • @HouseImprovements
      @HouseImprovements  4 роки тому

      Yes your dryer will need 240v so three wires is not enough. The wire and the receptacle need to be the proper size/type for a clothes dryer.

  • @fuqui035
    @fuqui035 7 місяців тому

    How did you attached the p,ug plug to the metal plate

  • @KenNYC212
    @KenNYC212 6 місяців тому

    Hi Shannon @HouseImprovments, I've watched a lot of your videos and hoping you can help!
    All I'm trying to do is hookup a dryer in an older building (1976 condo) and I've added a ground and converted from 3-prong to 4-prong, standard US 30AMP circuit. I've watched like 30 videos and everyone seems to claim 240V is either RED or ORANGE, and showing a FLAT wire. I have a single Romex BLACK, ROUND 10/3 wire (2 white/black hot, 1 ground, and 1 neutral bare wire) coming into a 1-gang old metal box (is this legal?). I am in the US/North American (NJ state). I simply want to move the receptable down lower on the wall out of sight, i.e. extend the Romex a foot or two inside the existing drywall, using up-to-date code and the correct type of cable, connector, and junction box(es). Please explain:
    1) Why is my 10/3 a BLACK cable, and round not flat RED or ORANGE? Is this just common in older construction, or was the wrong type of cable used all the way back to the circuit breaker?
    2) What is the difference between Romex 10/3 300V vs. Romex 10/3 600V, which are currently the only ones still being sold at Home Depot. No sign of any red or orange 10/3. Are these ROUND BLACK cables still current and OK to use inside drywall (like what appears to be there now), or is that the older style, for outdoor use, or some application? When did they switch from red or orange to black, and flat to round, or vice versa?
    3) Does it matter whether I use 300V or 600V? What is the typical application for each? (I've googled till I'm blue in the face...can't find ANY videos talking about this anywhere!!) Is 600V just overkill? What is that typically used for? Would it hurt anything to use 600V in a 300V application (ie either fine for an electric dryer 240 30AMP circuit), or is it bad to use a higher rated voltage wire for any reason?
    4) What is the proper size ELECTRICAL / JUNCTION box for a 30AMP Dryer 240V circuit with a METAL BOX (ground screw in box)? Except for yours, 90% of the 4-prong dryer outlets stocked at Home Depot and almost every video on UA-cam seem to show people installing these newer 4-prong dryer outlets into 1-gang boxes. Even the receptable instructions itself claim "Do not install in 1-gang" yet the plate itself is sized for 1 gang (only two screws top and bottom, like on a normal light switch)! What is the code for 240A? 1-gang or 2-gang? Why are the majority of outlets sold with a 1-gang plate if the box is supposed to be 2-gang?
    5) What is the code and safety requirements to SPLICE and EXTEND the cable inside existing drywall? I read somewhere code says you can't have a junction box behind drywall. So do I need to actually REMOVE the existing junction box, splice all 4 wires including ground using push-fit or butt connectors to extend the cable inside the drywall, then leave that cable there loose in the wall outside of a junction box, just to relocate a new metal outlet box 2 feet lower with an outlet on it? Is it OK to drywall over the existing spliced section? (This seems a lot more unsafe to me than just leaving the spliced section inside the existing metal junction box, and then extending on down to the next one.)
    Thanks if you can help. Will vote up the video...because I can't find these basic answers anywhere! Thanks

    • @HouseImprovements
      @HouseImprovements  6 місяців тому

      Hi Ken, This is not the easiest place to discuss things like this , please join my forum and we can get you all answered and discuss some other ideas.www.house-improvements.com/forums/

  • @stringzmegood
    @stringzmegood 6 років тому +1

    Fun game...count how many times he says typical or typically. Lol

  • @montazmeahii6029
    @montazmeahii6029 2 роки тому

    at 1:44 "You'll want to check in your own personal codes for your local area what you'll need..." How does a person do this?

    • @twotone3426
      @twotone3426 2 роки тому

      Go online and look for your local code, speak to your Municipality, try asking a local Electrician and see if they're nice enough to answer and help.

  • @karlagarza6614
    @karlagarza6614 5 років тому

    If I have a 4 prong dryer wire cord, but my wall only has 3 wires coming out (no ground wire),
    Can I attach a short ground wire in the outlet box with just a screw, would that be fine, would that work? or MUST THE GROUND WIRE come directly from the main electric box?
    My washer is newer and has a 3 prong wire cord, but I am planning on changing that to a 4 prong cord.

  • @geoffparmenter7006
    @geoffparmenter7006 4 роки тому

    Add how to connect to the breaker box when all you have is an existing 3 wire outlet being replaced.

  • @jeffthewhiff
    @jeffthewhiff 3 роки тому

    Another great video, Shannon! Have a question for you, I recently bought a new washer and dryer and had to purchase a new 3-prong 30 amp. dryer cord as well, but the new cord doesn't fit into my receptacle because of the "L" shaped opening. Will I have to purchase a new receptacle, so that it will fit the new cord? It kind of sounds like I would have to do that.

    • @HouseImprovements
      @HouseImprovements  3 роки тому

      Please start a discussion in the forum and I can help from there . sounds like your existing plug is maybe 50Amp but the new cord is 30? Make sure you have the proper cord for the new dryer . We can chat in the forum easier. www.house-improvements.com/forums/

  • @janeyochotsky9501
    @janeyochotsky9501 4 роки тому

    Is there a minimum code height off the ground, or a maximum for a 220 electrical box in a basement utility room?

    • @HouseImprovements
      @HouseImprovements  4 роки тому

      Not as far as I can remember, as long as the cord can reach it without being extended. usually around 36" is a nice height because it is easier to access.

  • @jonienglish3231
    @jonienglish3231 4 роки тому

    KOOL
    Another GOOD VIDEO !
    Question Shannon - Does it have to Be a ORANGE WIRE ?
    Currently mine looks like a BROWN CLOTH WIRE - just Going to Move the Dryer to another Location and Replace the Recepticle

    • @HouseImprovements
      @HouseImprovements  4 роки тому

      That is an older wire and it will work if it is the correct wire gauge size and correct # of wires. If you are just moving an existing dryer you had already been using you should be fine. The information will be stamped on the outer cover of the wire as to size and wire #

    • @jonienglish3231
      @jonienglish3231 4 роки тому

      @@HouseImprovements Thanks - Currently i n use no issues

  • @tomtran4431
    @tomtran4431 6 років тому

    thanks

  • @Djm9393
    @Djm9393 7 років тому

    can u please do a video on how to use a multimeter im planning on getting a fluke 323

  • @TtvDrakyll
    @TtvDrakyll 3 роки тому

    Rewiring house, thought dryer was 50 amp so bought 6/2 wire, seen the dryer is actually 30 amp, can I still use the 6/2 wire with 30 amp breaker or does it have to be 10/2

    • @HouseImprovements
      @HouseImprovements  3 роки тому

      You can use it as long as you can fit the conductors under the screws on the breaker.

    • @TtvDrakyll
      @TtvDrakyll 3 роки тому

      @@HouseImprovements ty

    • @KevinCoop1
      @KevinCoop1 2 роки тому

      Needs to be 3 conductor with ground, not 2.

  • @morocCaNhmed
    @morocCaNhmed 6 років тому

    In the wall there is just here wires. One bare wire, one black and a white one that has red tape. Can you tell me how I can wire it? My washer/dryer is a stackable and comes with a 4 prongs cable. Where should do I put the wires? Does it matter if the bare (assuming it is the ground) goes into green hole or white hole of the receptacle?

    • @HouseImprovements
      @HouseImprovements  6 років тому +1

      You need to rewire right back to the panel/breaker box. If you come to my forum with your question we can help from there. www.house-improvements.com/forums/

  • @davegt27
    @davegt27 6 років тому

    does the ground wire have to have the ground wire attached ? I see some metal boxes that don't have a screw in the back??

    • @HouseImprovements
      @HouseImprovements  6 років тому +1

      In the US I believe your boxes come without the screw for some reason. You buy them separate.

    • @robsoult3523
      @robsoult3523 6 років тому

      And a lot of applications you do not need to ground the metal box. The actual metal on the outlet is grounded so when you screw the outlet into the metal box it grounds the box for you.

  • @rubix2007
    @rubix2007 3 роки тому

    thx

  • @ickisandoblina
    @ickisandoblina 6 років тому

    I've never installed 30 AMP breaker before. This is for a PTAC (large wall unit AC/Heater, like you see in hotel rooms); I'm replacing the whole run because the old unit was 20 AMP. The single outlet accepts three prongs with ground and two flat prongs that are in line ("- -" as opposed to "="). The concept that both black and white are hot confuses me - it's a 10 gauge 3 wire (black/white/bare ground), so I wire both black and white into the 30 AMP breaker (and ground to ground, of course). is that right? Does order matter?

    • @ickisandoblina
      @ickisandoblina 6 років тому

      Yes... It didn't make sense because it doesn't make sense for a 3 prong outlet.

    • @anonymousbyproxy8250
      @anonymousbyproxy8250 5 років тому

      icki, probably u did it already, but u cannot have two hots on the prong u describe. Only the black one is for hot and goes into the breacker and the white wire is the neutral and gets connected to the neutral bar on the panel (where all the neutrals go to).

    • @anonymousbyproxy8250
      @anonymousbyproxy8250 5 років тому

      Misspelled by mistake breaker, sorry.

  • @HeartOfHippie
    @HeartOfHippie 7 років тому +4

    Can you put a regular window air conditioner into a wall?

    • @EM-fi2qg
      @EM-fi2qg 7 років тому

      Melony Smith You sure can. Frame it first and put supports outside and make sure the condensation that drips from the back. doesn't drip on any thing that shouldn't get wet. There are instructions on line all over the place.

    • @brianpiper3188
      @brianpiper3188 7 років тому +1

      Yes, I helped do it at my brother's house. Just remember, if you move any appliance/air unit containing gases like Freon R-22 refrigerant, let the appliance sit stationary before turning on. A common issue is laying down an upright fridge/freezer while moving and not waiting a few hours after upright (some instructions suggest 24 hours).

  • @chadwilson4114
    @chadwilson4114 4 роки тому

    I dont have a red. What do I do?

    • @HouseImprovements
      @HouseImprovements  4 роки тому

      please join our forum and ask there, we can help you from there.www.house-improvements.com/forums/

  • @ahmonbryant3446
    @ahmonbryant3446 6 років тому

    hey do you recommend join a union?

  • @Maskawanian
    @Maskawanian 7 років тому

    Dryer receptacles have to be secured on two sides as per code.

  • @MySpace662
    @MySpace662 6 років тому

    Isn't this wiring for a 120V/240V Dryer ?

    • @Wowzersdude-k5c
      @Wowzersdude-k5c 5 років тому

      All dryers are 240V. Two hot legs of 120V each, at !east in North America. In Europe, everything is 240V from lights to heavy appliances. In NA we use 120V for everything except ranges, dryers and the like (where we hook up that second 120V hot leg).

  • @padinjose3990
    @padinjose3990 6 років тому

    I have a 30 A breaker that is not been use, can I put a 20 A breaker and use it for something else. I'm doing a garage conversion.

    • @HouseImprovements
      @HouseImprovements  6 років тому

      Glad to see you came to the forum after this, that is the best place for question, thanks

    • @anonymousbyproxy8250
      @anonymousbyproxy8250 5 років тому

      If it matches the size on the panel, yes, u can

  • @Djm9393
    @Djm9393 6 років тому

    what's the difference between 14/2 wire romex vs 12/2 romex wire

    • @robsoult3523
      @robsoult3523 6 років тому

      djm93 the differences thickness of the copper wiring. 12/2 Romex is thicker than 14 2 Romex. There for 12-2 Romex is rated for 20 amps whereas 14/2 Romex is only rated for 15

    • @anonymousbyproxy8250
      @anonymousbyproxy8250 5 років тому

      And of course, having less copper is cheaper.

  • @kyzenlanx
    @kyzenlanx 7 років тому

    That's better mate, keep that head covered! ;)

  • @coltle8300
    @coltle8300 Рік тому

    Pull all permission slips from the masters you need.

  • @nocturnblizzard
    @nocturnblizzard 6 місяців тому

    Thanks for this video and getting straight to the point. Most how to videos are a lengthy mental masturbation seminar.

  • @quedogkualum
    @quedogkualum 4 роки тому

    I need to change the location of my dryer, can I relocate the wire by adding junction box and extend the wire to new location

    • @HouseImprovements
      @HouseImprovements  4 роки тому +1

      Yes you could as long as the wire is the right gauge and the distance is not crazy. If you need more assistance please go to the forum with questions.www.house-improvements.com/forums/

  • @mycats7321
    @mycats7321 6 років тому

    I plan to change the location of my laundry room and when I move things over, I want to upgrade to a 4-prong outlet from a 3-prong (I will be using the same wires since it is in an adjacent room just on the other side of the wall of where the existing outlet is). If there is not currently a ground wire, can I just add one in and tether it to a screw inside the outlet box? and does a bare wire have to be used for ground or could I wrap it in electrical tape except for where it connects to things to the outlet and screw?

  • @toddkratzer7953
    @toddkratzer7953 Рік тому

    You are wrong with the direction of the chord, the chord will go to the right the way you have it installed.

    • @jlew6803
      @jlew6803 6 місяців тому

      Thanks for pointing that out assho 🙄 everyone always has something to say.

  • @Jeff_Lee66
    @Jeff_Lee66 4 роки тому

    Be careful with that

  • @williamfinch7753
    @williamfinch7753 6 років тому

    4 pronged dryer outlets are 50 amp! Not 30 amp

    • @arthurfuentes970
      @arthurfuentes970 6 років тому

      U maybe talkin bout a range

    • @robsoult3523
      @robsoult3523 6 років тому +1

      William Finch there are different 4 prong Outlets you can have a 50 amp 4 prong outlet or a 30 amp. They will configure the prongs so that you cannot plug in a cord that is not rated for that receptacle. But there are multiple 4-prong receptacles that are different amperage ratings. For example a range has a 4 prong as well as this dryer. So it is most welder receptacles

  • @adamalford5650
    @adamalford5650 3 роки тому

    TYPICALLY

  • @geoffparmenter7006
    @geoffparmenter7006 4 роки тому

    Typically

  • @jeffreylabarrett2871
    @jeffreylabarrett2871 Рік тому

    Horrible vague descriptions.

  • @eljbarr
    @eljbarr 3 роки тому

    Thank you for this video

  • @dogtown128
    @dogtown128 6 років тому

    I have a older dryier outlet with 3 prong in my garage that I don't use,question is I want to install a wall ac unit but can I use a 220 v ac unit with that outlet ?basically can a 220 ac work with a 220 to 240 v outlets?or does it have to be exactly 220v?

    • @HouseImprovements
      @HouseImprovements  6 років тому +1

      Same thing.If the plugs are the same then it will plug right in, otherwise you may need to change the receptacle to match the AC unit. Be sure the breaker is also the correct size for the A/c unit and wiring in the wall. please use my forum if you have further questions. www.house-improvements.com/forums/