How To Install a 30 amp Dryer Circuit With Breaker and Outlet

Поділитися
Вставка
  • Опубліковано 21 сер 2024

КОМЕНТАРІ • 122

  • @botsman35
    @botsman35 3 дні тому

    Absolutely love your ability to turn any project into exiting show!

  • @davidparker2173
    @davidparker2173 Рік тому +24

    You make me feel like an apprentice on the job with a friendly pro who is not dedicated to ruining my day. You also detail fairly well. I would rather hear things again and again than for some guy to assume I already know this, and this, and that. I just hit the like, and subscribe. Thanks

  • @RBG-tr9ce
    @RBG-tr9ce 5 місяців тому +2

    I'm doing this exact job tomorrow AFTER I fish the wire down the walls. I had done this 50 years ago so this was a good refresher. "See one, do one , teach one".

  • @CasualRican
    @CasualRican Рік тому +3

    Thanks again for this video, I installed my dryer outlet by following your instructions. 👍

    • @Askmediy
      @Askmediy  Рік тому +1

      Hope it works lol. Good deal

  • @davesillik
    @davesillik 6 місяців тому +1

    Thank you. Haven't ever done 220 but it all worked out beautifully and safe.

    • @Askmediy
      @Askmediy  6 місяців тому

      Awesome glad to hear it

  • @jacknelson4212
    @jacknelson4212 Рік тому +2

    Great video. Only one I could find that hooked up the 4 wires and breaker in the breaker box. Also good explanation for the reason from going from 3 to 4 wire recepticle.

    • @jesserentas7425
      @jesserentas7425 Рік тому

      Bro you ain't kidding I'm looking at these other videos thinking where in the world do the other 2 wires go christ!😂

  • @FrankBocker
    @FrankBocker Рік тому +1

    I really like all the little side details and prerequisite information peppered in this tutorial. There's a lot of higher-budget stuff around that's not nearly as informative.

    • @Askmediy
      @Askmediy  Рік тому +1

      Thanks Frank. It’s what I try to show

  • @MarineMT-0312
    @MarineMT-0312 3 місяці тому

    Brother from the northeast best friggen video hands down no elaborate BS straight to the point, you are the man!!!

    • @Askmediy
      @Askmediy  3 місяці тому

      Thanks buddy, yeah who has time for BS

  • @insanechevy91
    @insanechevy91 Рік тому +2

    Guy reminds me of a old guy I worked with last summer wired aleast 4 boxes with him more then I can remember service calls for light fixtures and ceiling fans and outlet replacements lol cool guy 😂

  • @malindabrowning9240
    @malindabrowning9240 Рік тому +1

    I think you’re hilarious. I recently wired up my breaker and the outlet for a dryer, and I definitely was a little nervous about turning on the breaker. You made me laugh so hard when you were teasing us about it.

    • @Askmediy
      @Askmediy  Рік тому

      LOL But very true LOL.

    • @blizte3
      @blizte3 11 місяців тому

      @@Askmediy Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?

  • @VicToR_Rider
    @VicToR_Rider 2 місяці тому

    Lol u nailed it with hearing a pop and the wife yelling fire😅 I messed up changing dryer plug. Mixed the black and white.

  • @germangomez7097
    @germangomez7097 Рік тому +5

    Perfect explanation. Just what I was looking for. Thank you

    • @Askmediy
      @Askmediy  Рік тому +1

      Awesome, glad I could help you out.

    • @blizte3
      @blizte3 11 місяців тому

      @@Askmediy Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?

  • @davidgasperlin6807
    @davidgasperlin6807 Рік тому +3

    Great video im putting in a new line to my dryer so this really helps

  • @juanftuchezsandoval2031
    @juanftuchezsandoval2031 9 днів тому

    Thanks for the video you explain it perfectly exactly the way I want to hear thanks again

    • @Askmediy
      @Askmediy  8 днів тому

      Awesome, glad you liked it.

  • @happycamper137
    @happycamper137 Рік тому

    Thank you for this video, I agree with all the comments. It really helped me, every electrician I talk to say they'll do it and don't. I learned what the wires are for and the positions. Which now gives me knowledge and confidence. Again, thank you.

  • @IamMattW.
    @IamMattW. 11 місяців тому

    Perfect! Exactly what I’ve been looking for. Nobody explains the panel part. And you made this video very entertaining! Hopefully my wife doesn’t yell at me though 🤣

    • @Askmediy
      @Askmediy  11 місяців тому +1

      Good deal. Thank you so much

    • @blizte3
      @blizte3 11 місяців тому

      @@Askmediy Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?

  • @AngelerFils
    @AngelerFils Рік тому +2

    00:43 The counting made me burst out laughing 🤣🤣

  • @DelmaRaySmithJr
    @DelmaRaySmithJr Рік тому

    Funny way of sharing what you know, in a humorous manner, thx

    • @Askmediy
      @Askmediy  Рік тому

      Can't be a stiff right.

  • @mikebartoli4755
    @mikebartoli4755 Рік тому

    That was just like standing next to my uncle while he's teaching me something! Well done sir, thank you making this tutorial.

    • @Askmediy
      @Askmediy  Рік тому

      Very nice to hear. Thank you very much

    • @blizte3
      @blizte3 11 місяців тому

      Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?

  • @youngjimmystro8176
    @youngjimmystro8176 4 місяці тому +1

    Lmao I love the ending man thanks for this video. Very helpful. I think I mis connected my outlet thanks for this!

    • @Askmediy
      @Askmediy  4 місяці тому

      Thanks buddy, glad you liked it.

  • @ricodinero4926
    @ricodinero4926 7 місяців тому

    come on askmediy , you make it look easy.

    • @Askmediy
      @Askmediy  7 місяців тому

      Because it is. You can do it

  • @briankeithhamilton4216
    @briankeithhamilton4216 9 місяців тому

    Loved the Ending! Thank you🤗

  • @hamsbyyams
    @hamsbyyams 6 місяців тому

    “Let’s just say this is being inspected. WhiCh iT’s sUppOSed tO Be 🤪.” Had me cracking up lol

  • @robmorse5239
    @robmorse5239 Рік тому

    Thanks... I really like you teaching style

  • @juancruz4179
    @juancruz4179 19 днів тому

    Thanks for this good video.

  • @UploadsbySK
    @UploadsbySK Рік тому +1

    Glad your uploading again!!! 💪🇮🇹

  • @alsemi-back-up579
    @alsemi-back-up579 Рік тому

    Great Video & Explanation of Wiring The RightWay!
    Thanks ForThe Upload
    Keep up The Great Work That You Do
    From Canada.

  • @alangloria939
    @alangloria939 6 місяців тому

    I was convinced until the end 😅 adrenaline just shocked my body

  • @joshcapecod6098
    @joshcapecod6098 Рік тому

    Good video. Except the breaker is required to be GFCI...since 2020. And best to check the dryer cord hookup as well....kind of big things.

  • @melquemcleash6607
    @melquemcleash6607 10 місяців тому

    This guy is a good teacher!

  • @majinkakashi20
    @majinkakashi20 Місяць тому

    Awesome video, thanks man

    • @Askmediy
      @Askmediy  Місяць тому

      Thank you so mush

  • @SAWA-nx5co
    @SAWA-nx5co Рік тому

    I spent few hours to find this. Thanks. You explain all from A to Z)))

  • @whoisradu
    @whoisradu Рік тому

    You make me feel like I can actually do this, even though I am extremely terrified, L O L

  • @paulholloway5458
    @paulholloway5458 Рік тому

    Brilliant Work, Thanks.Just needed a fresh reminder.

  • @jsville2023
    @jsville2023 Рік тому +1

    This guy is great. Subscribed.

  • @skippy493
    @skippy493 Рік тому +2

    Hey man when are you going to post some new videos I really like your videos

  • @mattkelley7890
    @mattkelley7890 10 місяців тому

    Never showed a close up inside the box. THE MOST IMPORTANT PART

  • @sickntired2059
    @sickntired2059 9 днів тому

    You're good.

  • @marchaney
    @marchaney 5 місяців тому

    Thank you!

  • @bryanlipscomb8918
    @bryanlipscomb8918 Рік тому +1

    You funny dude. Great tutorial

  • @user-ym3nk2ww4c
    @user-ym3nk2ww4c 10 місяців тому

    Excellent explanation... should I use 10/3 romex to the panel from a 30 amp inlet plug for a generator (7500 running watts)? Or can I use 10/2 romex?

  • @fuqui035
    @fuqui035 5 місяців тому

    The plate cover had Togo first behind the plug

  • @user-je3jo1kn8x
    @user-je3jo1kn8x 8 місяців тому

    Excellent video

  • @LetsGo6009
    @LetsGo6009 7 місяців тому

    Thanks!

  • @josefcalderonromero8452
    @josefcalderonromero8452 Рік тому

    Beautiful 🤩 exactly what I was looking for . Question. I want to install about 5-8 240 baseboard heaters in my basement. You think 2 30 amp circuits would be enough?

    • @Askmediy
      @Askmediy  Рік тому

      Most baseboard heaters are 20 amp. Please follow the instructions for sure.

  • @nickdiamond7595
    @nickdiamond7595 Рік тому +1

    0:45 He's giving us the neutral finger

  • @theadventuresofchris1409
    @theadventuresofchris1409 Рік тому

    thank you for making this video

  • @Douglaskyle9191
    @Douglaskyle9191 9 місяців тому +1

    If my wire to the black dryer outlet box is damaged by a dog I feel like I could cut it shorter and move the outlet higher instead of running all wire for my outlet. I have exposed silver wires that wrap around the core that are severed but dryer still works.

    • @Askmediy
      @Askmediy  9 місяців тому

      Seems like it would be better to just replace the dryer cord.

    • @Douglaskyle9191
      @Douglaskyle9191 9 місяців тому

      The outlet it plugs into is damage but not the actual cord to the dryer. A dog ripped open the sheet rock and began to tear open the wire leading to the outlet. I found this when getting my house ready to sell. The old owners left me this surprise and I have been living with it for 6 years lol Also the outlet is against the floor which I think I saw is not code anyways. 1987 home

    • @Askmediy
      @Askmediy  9 місяців тому

      @@Douglaskyle9191 There is no code on the height of the outlet. If the wire is coming above it, you should be able to just raise it up to good wire.

  • @lionwolf5768
    @lionwolf5768 10 місяців тому

    Great video thank you!

  • @djreag8614
    @djreag8614 Рік тому

    HEY DOMINIC ,YOU DA MAN ,COME UP TO NOVA SCOTIA AND DO SOME ELECTRICAL ,,

  • @jasonmacdonald27
    @jasonmacdonald27 11 місяців тому

    GREAT VIDEO

  • @oliverlu3259
    @oliverlu3259 Рік тому

    make it very clear to me. good job. thank you1

    • @Askmediy
      @Askmediy  Рік тому

      Awesome. thank you so much.

  • @Shadi2
    @Shadi2 Рік тому +1

    By any chance, is your brother a botanist?

  • @christianahava
    @christianahava 11 місяців тому

    Top notch info

  • @stevenramsar456
    @stevenramsar456 Рік тому

    Very helpful thanks😂😊

  • @be4fourty
    @be4fourty Рік тому

    Thanks for the video

  • @troyandeviegray9736
    @troyandeviegray9736 Рік тому

    It looks like the wiring on the hot water tank are 12 ga is 10ga okay for the run of about 10 ft and 10ga 3 wire outfit a dryer that’s even closer to the power panel, also I have a Meg welder the plug has a ground and a small and large knife blade the the outlet shows 120/240 at 50amp, how big should the wire be and what size breaker do I need

  • @ReyesCTR0025
    @ReyesCTR0025 Рік тому

    Nice video!!!

  • @lionelbutnotrichie7703
    @lionelbutnotrichie7703 3 місяці тому

    Is there code for how far or close an outlet can be to the circuit box. I have to move my dryer to the opposite wall and the opposite wall contains the breaker box

    • @Askmediy
      @Askmediy  3 місяці тому

      No not at all. Distance, yes. But nothing you need to worry about.

  • @jenniferowen-ep2gp
    @jenniferowen-ep2gp Рік тому +1

    Tbis is a dumb question, but, you said 30 Amp breaker. And it's a double breaker... does that mean 15 and 15? Or 30 and 30

    • @Askmediy
      @Askmediy  Рік тому +1

      Not dumb at all. This means the total protected circuit is 30 amp

  • @whoisradu
    @whoisradu Рік тому

    Hey guys what if the new 30A breaker doesn’t fit in the old box? Do you just get two 30 breaker that are the same type as the old breakers and run the two hots to each? Thanks for any advice

  • @Ojeramup12
    @Ojeramup12 4 місяці тому

    Can the green ground wire be connected to the white ground port? On 10;00 the wire is not connected.

    • @surferdude642
      @surferdude642 Місяць тому

      No. Only to the green ground screw and never connect a ground wire to a neutral intended location. The neutral and ground are bonded at first disconnect means (usually the main panel) and nowhere else.

  • @geyser3445
    @geyser3445 Рік тому

    I have a 220 volt electric hot water heater in my basement and want to add a switch at the top of my basement steps to turn it on and off. Can you show us how to do that and what switch to use? Thanks.

    • @Askmediy
      @Askmediy  Рік тому

      Just like any other switch. But it's a two-pole switch. Meaning that each side of the switch is for each hot. With 240 volts it's essential to switch both hots.

  • @bobbydbuilder2873
    @bobbydbuilder2873 Рік тому

    I have old air compressor with a 10.20 nema. The only outlet I could find does not have a ground screw. Just 2 gold hot and silver neutral. I need some advice or a quick how to. Does it need to have a ground or just wire as is?

    • @Askmediy
      @Askmediy  Рік тому

      Are you sure it's 220 volt?

  • @tomassoyweyvon4902
    @tomassoyweyvon4902 Рік тому

    Hey, Piasan...you mentioned Old vs New dryers with electronics, the question now is, the home dryers are wired with two wire 10, i had a new washer dryer installed with electronics, should i convert the two wire to three 10 ???? access is no problem

    • @Askmediy
      @Askmediy  Рік тому

      Funny you say “piasan” I’m in Italy right now lol. Yes, you should if you can. Because you’ll need the two hots and the neutral. Ground of course

    • @tomassoyweyvon4902
      @tomassoyweyvon4902 Рік тому

      @@Askmediy Hey, grazie per la reposta..I will do that...Godere!!!

    • @tomassoyweyvon4902
      @tomassoyweyvon4902 Рік тому

      in addition i found out 1996 was the cutoff for three prong vs 4 per N.E.C., again Thanks

  • @djreag8614
    @djreag8614 Рік тому

    Hey Dom, can I put neutral and ground wire on the same side in the panel box?

    • @DominickAmorosso
      @DominickAmorosso Рік тому +1

      Sure, as long as it’s not a sub-panel

    • @djreag8614
      @djreag8614 Рік тому

      @@DominickAmorosso THANKS DOM, TOO EXPENSIVE TO HIRE ELECT. SENIOR YA KNOW ,,, NOW ONE MORE QUESTION THE COPPER GROUND THATS BARE ,CAN I JUST ATTACH IT TO THE SCREW AT THE BACK OF THE BOX THEN CONNECT IT TO THE GROUND PLUG OPENNING ?.. PLUS THERE ARE STILL LIVE WIRES EVEN THOUGH THE PANEL IS SHUT OFF RIGHT?

  • @hwl6969
    @hwl6969 Рік тому

    Does it matter if you use a blue plastic box or a metal one?

    • @DominickAmorosso
      @DominickAmorosso Рік тому

      No, not at all but if you use a metal box, you will have to ground it

  • @marineguy4eva
    @marineguy4eva Рік тому +1

    That neutral wire doesn't give a.....!

  • @seanrobbins1916
    @seanrobbins1916 Рік тому

    I would apprentice with you

  • @Hayden-sp1ol
    @Hayden-sp1ol 9 місяців тому

    Extra grond wire via pig tail...? ?? I lost

    • @Askmediy
      @Askmediy  9 місяців тому

      Ground outlet to metal box via the ground wire coming in

  • @blizte3
    @blizte3 11 місяців тому

    Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?

    • @DominickAmorosso
      @DominickAmorosso 11 місяців тому

      That’s a big question, what did you test?

    • @blizte3
      @blizte3 11 місяців тому

      power on but dryer will not heat up@@DominickAmorosso

    • @blizte3
      @blizte3 11 місяців тому

      also it has power spin tumbler without heat
      of any kind, on any heat setting, no sparks nor signs electric discharging beyond normal@@DominickAmorosso

  • @susancasavant5227
    @susancasavant5227 8 місяців тому

    what a goober

  • @TonyyFlow
    @TonyyFlow Рік тому +1

    FIRST!

  • @woodstream6137
    @woodstream6137 3 місяці тому

    Probably calling an electrician. I need to run a ground to old 3 prong dryer outlet, thankfully its like a foot away from the breaker. My 30yr old speed queen finally finally died and I'm loathing having to buy a new budget machine.

  • @kavya1638
    @kavya1638 3 місяці тому

    gonna leak something here... your dryer doesn't need to be using 30 amps, in fact, just a few pico amps. the reason it draws so much is because it was designed this way (on purpose), ie, the electric company needs to make money somehow. all your electronics, really, are designed to operate in the high amp range. 15amp vacuum cleaner, blender motor, etc.. turns out, a little project that draws energy out of the air feeds a heating element in the "pico amp range" and gets just as hot as your dryer's heating element. thanks to a few advancements in this field, the electric company is guaranteed to go out of business. give it a few years..

  • @valery9958
    @valery9958 Рік тому

    ρяσмσѕм

  • @davidcase4600
    @davidcase4600 3 місяці тому +1

    Unsat, unsafe. If you use a metal box, ground it