How To Install Nest Doorbell Wired With No Existing Transformer or Doorbell

Поділитися
Вставка
  • Опубліковано 14 лип 2024
  • Google Nest Doorbell: amzn.to/3OwyFSd
    24v Transformer: amzn.to/3cMl5xb
    ↓Useful Links↓ My Favorite Tool: amzn.to/3NIFJuO
    Plug-In 24v Transformer:amzn.to/3z7yE1u
    Bell Wire: amzn.to/3J8rr67
    WAGO LEVER-NUTS: amzn.to/3OEXRGe
    Craftsman Portable Lights: amzn.to/3OBm8Nz
    Craftsman Cordless Drill: amzn.to/3S5C0us
    Craftsman Drill Bit Set:amzn.to/3S3FltZ
    Non-Contact Voltage Tester with Receptacle Tester: amzn.to/3RfB9XH
    Was this video helpful to you? Send a tip:www.paypal.me/bensahlstrom
    Become a Patron: / bensahlstrom
    In this video I show you how to install the Google Nest Doorbell (formerly known as Nest Hello). This is the wired version which requires 24 volt power, so I also show you how to install a transformer to supply that power to your doorbell.
    0:00 - Google Nest Doorbell Intro
    0:15 - Why Get The Wired Version
    1:24 - The Devices & Materials You Need
    2:58 - Placement Height
    4:35 - Running Wire To Power Source
    5:16 - How To Install 24v Power Transformer
    11:54 - How To Wire Google Nest Doorbell
    14:53 - Testing The Device
    16:40 - Correcting Our Wiring
    18:42 - Testing The Device Again
    19:48 - Installation Progress
    21:51 - Second Transformer Installation
    24:34 - Finishing Up The Installation
    25:13 - Conclusion
    26:02 - SUBSCRIBE!!!
    Thanks for watching and subscribing! As an Amazon affiliate I earn from qualifying purchases. Thank you for your support!

КОМЕНТАРІ • 85

  • @stefanennest7982
    @stefanennest7982 3 місяці тому

    This video rocks! Glad I found your channel because I started to watch the video on sub panels. You really explain this doorbell process way better than others. Some are very good but your video is the best! Thank you very much! 😎👍👍🙏🙏

  • @billk8780
    @billk8780 Рік тому +2

    My father was an industrial electrician and taught me to always scrape conductors first then twist them together tightly before adding the wire nut. BTW, it's a good idea to check tightness on all the screws and nuts when you're in a box.

  • @MrFitness94
    @MrFitness94 Рік тому +1

    Thanks for the vid. The route for a doorbell wire requires some decent knowledge on house construction; these are some good simple ways to tackle it!

  • @watermanone7567
    @watermanone7567 Рік тому +7

    I am surprised that you didn't use the shut off switch for the furnace instead of mounting the transformer inside of the AC blower housing. That could confuse the next HVAC guy that services the HVAC unit. Hope you tagged it well. Thanks for the video.

  • @annawulf4910
    @annawulf4910 11 місяців тому +17

    We ended up exchanging this model for the slimmer version ua-cam.com/users/postUgkx0jZ_lGlDVJhDnmagEU8gn47cmfPNlLQU because it was too wide for the only door trim area that made sense to mount it on. However, we should have just noted the dimensions prior to purchasing. Otherwise, we love the doorbell. It works perfectly, and the video is very clear, even at night.

  • @stanrosenblum4669
    @stanrosenblum4669 Рік тому +1

    Nice video. As DB said pretwist is better than hoping the wire nut will twist the wires together securely. The on going pretwist vs wire nut twist argument but you can always use wago 221 to securely join stranded and solid wires together.

  • @ziggiezaggie
    @ziggiezaggie Рік тому

    You got my thumbs up for the learning lesson you left in there..

  • @rccullis1134
    @rccullis1134 Рік тому

    Great demo Ben.

  • @LukaFinnHarrison
    @LukaFinnHarrison Місяць тому

    So to confirm, if you’re not installing a physical chime, you can skip adding the white chime connecters that come in the box? It was my suspicion but all the info I found said you “can’t” so I wasn’t sure. I have 2 (front and side door) nest doorbell cams getting wired to one transformer (which I need to install into a pre-existing junction box) and it’ll save me so much time and wiring mess if I can just skip the chime connectors! We don’t mind no physical chime box anyways as we prefer silenced alert options (dogs barking, kids sleeping, etc) and we use the Google nest minis to alert us so I don’t feel like it’s worth it to install a chime if I can skip that.
    Super helpful video btw! Our house was built in 1948, the doorbells were wired to a BUS chime (like, actually designed for a public transit bus, 70s time frame from the research I did - not much info available on them at all) that are battery operated, but have the option to be hooked up to an 8v transformer.
    Took me embarrassingly too long to realize there was no transformer 🤦🏼‍♂️ everyone I asked looked at me like I was dumb bc “there has to be a transformer somewhere” but nope, traced the wires all the way through the attic right to the doorbell buttons and they were connected straight to the bus chime and only worked when the batteries were in it. Absolutely wild design 🤣 but I’ll take it over the last house we installed them on. Built in ‘52, horrid wiring. Shocked it hasn’t burned down. Over 20 (no, not exaggerating) unlabeled LOOSE wires were behind the chime box and it was a nightmare trying to figure out which ones had power, which ones ran to each door (front & back) and capping them all off safely lol

  • @GailsonPvPwtf
    @GailsonPvPwtf Рік тому +3

    17:30 what you should do: pretwist the solid conductors with some broad nose pliers like lineman pliers. take the stranded conductor, twist them together and then with your fingers, twist the stranded wires along with the other solid conductors, and then put the wire nut on. Imo, you should always pretwist wires when using wire nuts anyway so this is just an easy way to get solid connections every time without fail.

  • @cribbsprojects
    @cribbsprojects Рік тому

    Awesome video, great teacher. Super helpful tips. Earned a subscriber.

  • @petersonfamily6223
    @petersonfamily6223 Рік тому

    Very information and some great points. Thanks

  • @RandomNJ
    @RandomNJ 3 місяці тому

    As someone who fixes this kind of stuff. A lot of camera doorbells get replaced because they lose power when the homeowner turns off the furnace switch in the spring and fall. Because the homeowner doesn't know that their door bell is powered by the HVAC circuit.

  • @lilo2469
    @lilo2469 Рік тому

    Getting it Done ✅

  • @alnetsistemas
    @alnetsistemas Рік тому

    me parece el video execelente, porque le pasan lo que normalmente sucede al hacer un trabajo. Muy bueno tu video

  • @jenlf78
    @jenlf78 Рік тому

    Great instructions and video! You do a really great job walking through everything. I've been doing some minor electrical work at home and I'm preparing to install a Google Nest Doorbell and plan to tap into the light switch on the inside next to the door. I don't want to open up the wall more than just to feed the wire through. Can you put a transformer in a 2-gang light switch box? Or could I run the bell wire up to my exterior porch lights and tap in there? Thanks again!

  • @michaelmiller1109
    @michaelmiller1109 Рік тому

    I have doorbell wiring that I have abandoned for many reasons but never could find the transformer powering them anywhere, now I am thinking it might be in my A/C. I can finally de-energize those capped 24v wires in my wall.

  • @jdubya54
    @jdubya54 Рік тому +2

    Excellent video. And thanks for leaving the goof ups. I dont feel so bad for mine.

  • @FishFind3000
    @FishFind3000 Рік тому +2

    6:13 lights are off and so is every clock in that house…

  • @DJ_Driven
    @DJ_Driven Рік тому

    Unfortunately my low voltage wiring from the mechanical room that runs upstairs to the front doorbell is not working. Is there a tester I could use to verify if it's a low voltage wiring fault? I do have an backup AC to DC converter I could use, but would prefer to do the dedicated low voltage setup.

  • @iteesea
    @iteesea 2 місяці тому

    My transformer has a ground wire but I’m mounting it to a metal box, would it be fine to just cap off the ground?

  • @FISHH00KS
    @FISHH00KS Рік тому

    HELP!!! I have 5 AFCI out of 9 that are instantly tripping after a power surge. The 4 that are still "good" (active) are divided between the two circuits. How can I test to see if I have defective/blown AFCIs?

  • @stephboeker7835
    @stephboeker7835 Рік тому +2

    Lovely video !!
    Question :
    I have a pair of 3 way switches (2 brass, 1 silver & 1 green) controlling 8 LED lights for my carport. One switch from the sub-panel hot in the carport, to the lights and also connected to the other 3 way switch at the front door to my mobile home. This switch at the front door is in a box holding the 3 way switch and a 110 v 20 amp duplex outlet. The electrician hooked it up where either switch controls the lights, but, the outlet is only hot when switch at the sub-panel (carport) is in the on position ? If I turn the switch off at the sub-panel, the switch at the front door can still turn the LED's on but there is no power to the outlet there , no matter that switch on or off.
    Again, when the switch in the carport is off, there will never be power to the outlet at the front door switch ??
    I guess the problem is between the front door switch and the duplex outlet in that box ?
    CAN YOU HELP ??
    Thanks for your generous consideration,
    Sincerely .................
    Steph

    • @claytonfite3197
      @claytonfite3197 Рік тому +1

      Three-way switching hookups require that one switch receives the power for the light circuit to go to only one switch attaching to the dark screw. The two silver screws have two wires called travelers that come from switch number one over to switch number two. They attach to the two silver screws on both one and number two switches. Switch number two the wire going to the lights is attached to the dark screw on switch number. If your outlet is hooked up on switch number two it can not receive constant power through the switching from switch number one where the power for the light circuit comes from. the remedy is getting constant power with a neutral from a different source. It can be confusing the trick is locating the constant power that's not being switched. I hope this helps you. I am not much of a teacher. I'm just a do-it-get-it-done guy. who must play by the rules. I had this person just learning electricity as a student in an apprentice class. Had no working experience removing a 4-way switch at one door that was bad and needed to be replaced. I tested and tagged the bad switch for replacement. There were 2 large bays and 6 doors in this commercial building. The owner didn't want to pay me to replace it. He said I'll let my niece who is learning to be an Electrician to replace it. Then he said to me. What could go wrong its just a switch? LOL, Well, she removed the switch put the new switch in, and mixed up the two sets of travelers. Then went and removed two other switches and did the same thing. They had a mess and I didn't have time to play clean-up Yes it was just a switch. Until Oh No Oh No what the heck happened LOL. Be safe be carefull

    • @claytonfite3197
      @claytonfite3197 Рік тому

      Go to Electrician U on youtube. He has tons of videos on a lot of things. He has a unique way of explaining things in great detail. Cool stuff

    • @genebrodeur772
      @genebrodeur772 Рік тому

      Three way switches can get pretty complicated really fast if wiring gets mixed up. If you disconnect all six wires (carefully noting where each one goes), then turn power back on, only one should be hot. There then remains a load wire that goes to the light and four travelers. Always easy to mess a 3 way or 4 way circuit up if you’re not careful. Good luck!

  • @Kevin8U2b
    @Kevin8U2b Рік тому +2

    What about the doorbells' chime? Those 3 you installed probably ring the owner's phone, but what about ringing the audible chime for the rest of the household?

    • @BenjaminSahlstrom
      @BenjaminSahlstrom  Рік тому

      Smart speakers are the easiest solution in my opinion and they are typically pretty cheap.

  • @AndrewHelgeCox
    @AndrewHelgeCox 4 дні тому

    Do they ring a bell somewhere?

  • @scottrothe5947
    @scottrothe5947 Рік тому +1

    Why not use sealant to water proof the hole in the wood to prevent water rot?? Otherwise nice job!

  • @GailsonPvPwtf
    @GailsonPvPwtf Рік тому

    I believe there is a code about height minimums and maximums for disabled access. Idk if this applies here.

  • @user-ms5vq9zu9c
    @user-ms5vq9zu9c 10 місяців тому

    Me puedes mandar el diagrama completo de la instalación del timbre con camara

  • @echenduconfidence4998
    @echenduconfidence4998 Рік тому

    How do you pair the with monitor

  • @alonsobrito3926
    @alonsobrito3926 Рік тому +1

    What if I want to add a chime?

  • @dankelley9361
    @dankelley9361 Рік тому +1

    So, where’s the bell portion that rings in the house?

  • @tanker242
    @tanker242 Рік тому

    Was that a zinc coated wire or aluminum wire I saw? If it's aluminum shouldn't it be replaced, that looks dangerous.

  • @averageguy1261
    @averageguy1261 Рік тому

    I have existing wiring but no electricity. Suggestions?

  • @firepilot17
    @firepilot17 Рік тому

    Should have used a white wire, but, it’s an Airbnb!

  • @mrindependent1
    @mrindependent1 4 місяці тому

    Chime?

  • @ricknewman3373
    @ricknewman3373 9 місяців тому

    Did i see a doorbell on the stairs behind you?

  • @kittsdiy
    @kittsdiy Рік тому

    17:36 wirenut for solid & stranded conductors never a good choice ... 30 years ago when i learned in school always pretwist soldid copper wire and then wire nut . In the last 20 years not 1 electrician is using them anymore .. WAGO 221 lever style is the way to go if you want to connect solid conductors with fine stranded conductors .

  • @donl1410
    @donl1410 Рік тому +4

    Code violation- 422.12 Central Heating Equipment. Central heating equipment other than fixed electric space-heating equip-
    ment shall be supplied by an individual branch circuit.
    Exception No. 1: Auxiliary equipment, such as a pump,
    valve, humidifier, or electrostatic air cleaner directly asso-
    ciated with the heating equipment, shall be permitted to be
    connected to the same branch circuit.
    Exception No. 2: Permanently connected air-conditioning
    equipment shall be permitted to be connected to the same
    branch circuit.

    • @MAGAMAN
      @MAGAMAN Рік тому +1

      Yeah, that seemed a little sketchy to me even without knowing the codes.

    • @BenjaminSahlstrom
      @BenjaminSahlstrom  Рік тому +2

      So you're saying that since we added a transformer that supplies the doorbells inside of the HVAC equipment it technically is in violation?
      Thanks for pointing this out. Maybe I'll make a follow up video explaining this.

    • @donl1410
      @donl1410 Рік тому +3

      @@BenjaminSahlstrom Correct. The exceptions do not list equipment other than related to HVAC. If the equipment were shut down for an extended repair the security cam would be useless.

  • @tedlahm5740
    @tedlahm5740 Рік тому +2

    Fortunately a neutral was in that box?

    • @BenjaminSahlstrom
      @BenjaminSahlstrom  Рік тому +1

      True! Although it is technically required now to have a neutral at each switch location but that's a fairly recent development.

  • @ilikeelectronics100
    @ilikeelectronics100 7 місяців тому

    Hi

  • @mrindependent1
    @mrindependent1 4 місяці тому

    I wouldn’t feel comfortable leaving the transformer exposed next to a switch like that
    When people enter and reach for the switch they might touch the connections
    It’s low voltage but still can shock you

  • @JBK63
    @JBK63 Рік тому

    Wago

  • @zabizeyaee8002
    @zabizeyaee8002 Рік тому

    I noticed NM cable in tubing. yikes

  • @jragadio
    @jragadio Рік тому +1

    No actual chime installed?

    • @FishFind3000
      @FishFind3000 Рік тому +1

      Ikr, a doorbell with NO BELL!!! What’s the point it doesn’t ring!

    • @BenjaminSahlstrom
      @BenjaminSahlstrom  Рік тому

      Nope!

    • @BenjaminSahlstrom
      @BenjaminSahlstrom  Рік тому

      It can ring every device and Google home speaker you have so in reality it works just as well or better if you have a phone or smart speakers.

  • @madhounddog04
    @madhounddog04 Рік тому +2

    Do not get anything like this! The police can gain access to this without your permission! Even all the recordings from it. And then use it against you. And it's legal for them to do it!!

    • @FishFind3000
      @FishFind3000 Рік тому +1

      That’s why’s you make your own system and don’t use someone else’s. Same goes for email. If you own the servers you get all the rights over it.

    • @BenjaminSahlstrom
      @BenjaminSahlstrom  Рік тому

      Yeah honestly I'm with you there... What do you do to avoid the big name security companies? I've heard some good stuff about Ubiquiti.

    • @backupaddict1356
      @backupaddict1356 Рік тому +1

      @@BenjaminSahlstrom Unfi works well and frankly would have been a better choice.

    • @joephillips6634
      @joephillips6634 Рік тому

      @@backupaddict1356 Some of t he unifi doorbells are known to fail in cold weather. Not great for minnesota

  • @claytonfite3197
    @claytonfite3197 Рік тому +1

    Yes, a code violation. alteration of UL-listed equipment is not permitted. This is why all equipment is tested before receiving its certification and UL- listing. As to ensure it is safe as to its original engineering and use. something bad happens. it all comes back on you. Sorry just because it worked does not mean it's right.

    • @BenjaminSahlstrom
      @BenjaminSahlstrom  Рік тому +2

      Are you talking about adding the additional transformer in the HVAC equipment?

    • @Jon-hx7pe
      @Jon-hx7pe Рік тому

      @@BenjaminSahlstrom it's done all the time for humidifiers anyway

    • @donl1410
      @donl1410 Рік тому

      @@Jon-hx7pe Read the code and exceptions. 422.12

    • @claytonfite3197
      @claytonfite3197 Рік тому +1

      @@BenjaminSahlstrom The doorbell and cameras are not an accessory for the HVAC equipment and should not be tapping into its dedicated circuit. Humidifiers are an accessory for furnaces and are listed for that use. and can use that dedicated circuit. External equipment non-HVAC can not tap into that dedicated circuit. I would use a convenient power source such as a Duplex receptacle or light circuit that is not a Signage circuit or an emergency light circuit for EM lights and exit signs.. A+ grade. > finding the path to run your low voltage wire

    • @BenjaminSahlstrom
      @BenjaminSahlstrom  Рік тому +1

      @@claytonfite3197 Makes sense I suppose. I wasn't aware that the rule also applied to low voltage so for some reason I thought it really didn't matter. Isn't the NEC primarily focused on main line voltage? Thanks for taking the time to explain this.

  • @arthurleslie9669
    @arthurleslie9669 Рік тому

    I personally wouldn’t use their doorbell. Give me a stand-alone system of my own design instead.

  • @brucesimpson8579
    @brucesimpson8579 Рік тому +3

    Seems like having a dog might be better for handling nefarious people coming up to your door.

  • @ajescomiendo-kd3ks
    @ajescomiendo-kd3ks Рік тому

    You didn’t show the connection to a chime!

    • @BenjaminSahlstrom
      @BenjaminSahlstrom  Рік тому

      True, no chime used in this instance. Your phone acts as the chime.

  • @onlywenilaugh6589
    @onlywenilaugh6589 Рік тому

    Seems easy to steal. Thief could just carry a paper clip.

  • @DutchStar
    @DutchStar Рік тому +2

    100% surveillance by big tech.

  • @MAGAMAN
    @MAGAMAN Рік тому +1

    Another person saying acrosst. There is no T in across.

    • @BenjaminSahlstrom
      @BenjaminSahlstrom  Рік тому +2

      Shoot! I've been trying to correct that. Guess I'm just not there yet.

  • @cozzbp
    @cozzbp Рік тому +1

    Please please please do not get the Nest Doorbell. Mine no longer works when the button is pressed, it resets, rendering it useless. It's a very common problem, and Google refuses to remedy. GET A RING DOORBELL.

  • @Jon-hx7pe
    @Jon-hx7pe Рік тому +6

    better yet don't install the nest doorbell or any nest product. 💩💩

    • @MAGAMAN
      @MAGAMAN Рік тому +2

      Or any internet connected products with a mic and a camera.

  • @rmoutzen
    @rmoutzen Рік тому

    Where are the actual doorbells?
    How did you get wires to those?